Records from 2016 to 2026. Most recent: inspection, 13 April 2026.
Inspection history · 17
13 April 2026
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8302953
17 July 2025
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8124166
28 October 2024
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8024779
14 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7859249
10 April 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7859235
15 May 2023
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7629686
16 May 2022
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7412180
7 April 2022
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7412188
10 May 2021
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7200062
21 May 2020
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6960977
21 April 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6949589
21 May 2019
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6684946
15 May 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6416779
17 April 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6393848
9 May 2017
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6141453
10 May 2016
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5878673
19 April 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5859084
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 17 July 2025
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Master did not have a valid medical certificate present.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 18 July 2025
Resolution: Provided proof of Medical Certificate.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 17 July 2025
Resolved
Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel's normal berthing location or with a representative of the owner or managing operator of the vessel. The passenger count shall be available to the Coast Guard upon request. Vessel was not keeping real time passenger count ashore.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2025
Resolved 22 July 2025
Resolution: Sector Boston updated passenger count policy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 July 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Donning placard posted was for the wrong type of lifejacket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 25 July 2025
Resolution: Provided proof of proper donning placard.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 17 July 2025
Resolved
At a minimum, each placard must notify the reader of the operating requirements contained in §§ 151.67 through 151.73 as they apply to that ship. No garbage placard present.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 25 July 2025
Resolution: Provided proof of posted Garbage placard.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 17 July 2025
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Flame screens were not 30 x 30 mesh or greater.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 25 July 2025
Resolution: Operator installed new fuel vent with approved flame screen.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 May 2024
Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Vessel is outfitted with a 20" life buoy.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 30 May 2024
Resolution: Vessel installed 24" life ring to replace the 20" life ring discovered during Annual Inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 May 2018
Resolved
TJT01 Replace expired items in first aid kit (expired on 8/2017) by 22MAY18; 46CFR160.041/184.710.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2018
Resolved 17 May 2018