MAURY USCG vessel records
← All vessels

FANTASY VII

Built
1985
Last inspected
15 September 2021
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 September 2021
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG3117
248155
Flag
UNITED STATES
Maury page id
psix-248155

Documentation record

Registered dimensions (L × B × D)64.8 ft × 21.0 ft × 9.7 ft
Registered tonnagegross 88 / net 70
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDMR YACHTS INC · ARUNDEL, ME, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 30 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it88 - Simplified, Gross Ton
70 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 12 inspections, each with its date, unit and type; 48 deficiencies with the resolution recorded against each, 7 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

15 September 2021 Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7311358
14 June 2021 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7225254
26 June 2020 Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6994363
16 August 2019 Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6797867
28 June 2019 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6813227
26 February 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6755135
22 May 2018 Internal Structural Exam · In-Service Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6436319
11 April 2018 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6389748
14 November 2017 Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6306815
31 August 2017 DAPI Audit · Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6256779
22 August 2016 Annual Inspection · Administrative Inspection · DAPI Audit · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5981936
12 May 2016 Damage Survey · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5875229

Deficiency record · 48

02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 June 2020 Resolved
Prove depth of identified cracks to the satisfaction of the attending marine inspector/provide repair proposal.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2021
Resolution: Cracks were ground and repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 June 2020 Resolved
Clean bilge area under engine room decking in order to facilitate inspection of internal structure. Properly dispose of any oil and wash water.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2021
Resolution: Oil removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 June 2020 Resolved
Remove grating to facilitate inspection of through hull valves. Install valve handles on valves that do not have handles.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2021
Resolution: All through hull valves were inspected satisfactorily.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 June 2020 No resolution recorded
Install positive shutoff valves at the overboard hull penetration of submersible pumps.
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 26 June 2020 No resolution recorded
Present area forward of collision bulkhead that was previously inaccessible for inspection.
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 26 June 2020 No resolution recorded
Test new collision bulkhead to a head of water to the top of the bulkhead.
Action required: 17 - Rectify deficiencies prior to departure
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 26 June 2020 Resolved
Port side fuel tank vent is wasted in tank space. Make repairs to the satisfaction of attending inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2021
Resolution: Fuel venting has been replaced satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 26 June 2020 No resolution recorded
There are non metallic pipes and conduits that penetrate watertight bulkheads. Non metallic piping penetrating watertight bulkhead requires a metallic bulkhead fitting and a valve on both sides of the bulkhead or a single valve if operable from above the bulkhead deck. Provide proposal to modify.
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 June 2020 Resolved
Make areas under wasted battery trays available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2021
Resolution: Wasted battery storage arrangements were removed and satisfactorily replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 26 February 2019 No resolution recorded
FWD Main deck over anchor compartment has damage due to sampson post being ripped out of the vessel along with sections of the deck.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 26 February 2019 No resolution recorded
Fwd deck over fwd compartment has unapproved repair and rot due to failed deck sealant. Repair decking.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 26 February 2019 No resolution recorded
Collision bulkhead has rot that was hidden by fiberglass and transverse deck beams. Bulkhead must be repaired.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2019 Resolved
Multiple exhaust leaks on both main diesel engines make the engine room and the main cabin unsafe during operations. Repair all exhaust leaks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: Both main diesel engines have been completely overhauled and all exhaust leaves repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2019 Resolved
Port engine aft engine mounts are missing hardware. Renew mounts and/or hardware.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: All hardware was renewed.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 26 February 2019 Resolved
Fire pump is frozen and inoperable. Repair/renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: New Fire pump was installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 February 2019 Resolved
All bilge high level alarms are required to have an audible and visual indicator at the operating station. all alarms are inoperable. Repair/renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: High level alarms were renewed and tested all sat.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 26 February 2019 Resolved
Bilge pump in the vessel's tank space is inoperable. Repair/renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: All bilge pumps have been renewed and tested all sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 February 2019 Resolved
EPIRB hydrostatic release is expired and must be renewed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: New hydrostatic release was installed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 February 2019 Resolved
Fire extinguisher must be visually inspected monthy, and have annual maintenance conducted. Inspection and maintenance have not been conducted. Prove inspections have been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: All fire equipment was inspected and is all sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 February 2019 Resolved
All drill, survival craft maintenance, and chemical testing logs are missing. Provide new logs and maintain them per the CFR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2021
Resolution: Cleared deficiency as the vessel has transferred ownership, has been out of service and will have to prove the same when the vessel is presented for inspection prior to operation.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 November 2017 Resolved
PROVIDE SERVICING REPORTS FOR FIXED FIRE SYSTEM. 46 CFR 181.410.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2017
Resolved 21 November 2017
Resolution: PROVIDED SERVICING REPORTS FOR FIXED FIRE SYSTEM.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 November 2017 Resolved
LABEL HIGH LEVEL ALARMS FOR EACH COMPARTMENT. 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: LABELED HIGH LEVEL ALARMS FOR EACH COMPARTMENT.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 14 November 2017 Resolved
PROVIDE TIDE TABLES FOR AREA OF OPERATION. 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: PROVIDED TIDE TABLES FOR AREA OF OPERATION.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 November 2017 Resolved
LABEL EACH SWITCH ON DISTRIBUTION PANEL. 46 CFR 183.330.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: LABELED EACH SWITCH ON DISTRIBUTION PANEL.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 14 November 2017 Resolved
PROVIDE FIRST AID KIT. 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: PROVIDED FIRST AID KIT.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 November 2017 Resolved
PROVIDE LANYARD FOR RING BUOY WATERLIGHT. 46 CFR 180.70(d)(2).
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: PROVIDED LANYARD FOR RING BUOY WATERLIGHT.
Lifesaving › Lifefloat › Paddle
Issued 14 November 2017 Resolved
LASH PADDLES ON 02 LIFE FLOATS. 46 CFR 180.137.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: LASHED PADDLES ON 02 LIFE FLOATS.
Lifesaving › Lifefloat › Serviceable
Issued 14 November 2017 Resolved
REPLACE LINES CONNECTING LIFE FLOATS TO WATERLIGHTS. 46 CFR 180.130.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: REPLACED LINES CONNECTING LIFE FLOATS TO WATERLIGHTS.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 14 November 2017 Resolved
REPLACE LIGHT IN 01 FLOAT LIGHT. 46 CFR 180.200.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: REPLACED LIGHT IN 01 FLOAT LIGHT.
Documentation › Markings/Placards › Lifejacket Placard
Issued 14 November 2017 Resolved
PROVIDE LIFEJACKET DONNING PLACARD. 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: PROVIDED LIFEJACKET DONNING PLACARD.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 November 2017 Resolved
INSTALL ENGINE GUARDS ON BOTH ENGINES. 46 CFR 183.220.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: INSTALLED ENGINE GUARDS ON BOTH ENGINES.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 14 November 2017 Resolved
PROVIDE PROOF OF CPR TRAINING FOR ALL CREW.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: PROVIDED PROOF OF CPR TRAINING FOR ALL CREW.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 November 2017 Resolved
RE-FASTEN NAV LIGHT (MAST HEAD) MOUNT.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: RE-FASTENED NAV LIGHT (MAST HEAD) MOUNT.
Operations/Management › Drills/Instruction › Fire
Issued 14 November 2017 Resolved
COMPLETE SATISFACTORY FIRE DRILL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2017
Resolved 21 November 2017
Resolution: COMPLETED SATISFACTORY FIRE DRILL.
Lifesaving › Lifebuoys › Serviceable
Issued 31 August 2017 Resolved
Life ring is no longer serviceable. Renew ring.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: RENEWED LIFE RING.
Navigation › Collision/Grounding Avoidance › Radar
Issued 31 August 2017 Resolved
Vessel's radar is inoperable. Install new radar and prove proper operation, prior to operating with more than 49 passengers.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: INSTALLED NEW RADAR AND PROVED OPERATION.
Navigation › Piloting/Steering › Magnetic Compass
Issued 31 August 2017 Resolved
Vessel compass is not lit. Repair/renew.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: COMPASS LIGHT OPERABLE.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 31 August 2017 Resolved
Sink drain is broken and all water drains directlyinto the bilge. Re-plumb system.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: RE-PLUMBED THE SINK DRAIN FOR PROPER DISCHARGE.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 31 August 2017 Resolved
Both main engine turbo V bands are missing. Provide new V bands.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: PROVIDED NEW V BANDS FOR BOTH MAIN ENGINE TURBOS.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 31 August 2017 Resolved
Shore tie connection on vessel is missing the back cover. Renew connection to provide a completely enclosed connection.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: INSTALL NEW COVER FOR SHORE TIE CONNECTION.
Electrical › Electric Generation Source (service) › Panelboard
Issued 31 August 2017 Resolved
Generator distribution panel is missing one side. Close entire panel to provide shock protection.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: CLOSED ENTIRE DISTRIBUTION PANEL.
Electrical › Electric Generation Source (service) › Panelboard
Issued 31 August 2017 Resolved
Generator control panel is missing the AMP meter. Provide new AMP meter, and prove proper operation.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: PROVIDED AMP METER.
Documentation › Logs/Records › Logbook (official)
Issued 31 August 2017 Resolved
VEssel does not have a log for life saving maintenance or for monthly EPIRB testing. Provide log.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: PROVIDED LOGBOOK FOR LIFE SAVING MAINTENANCE FOR MONTHLY EPIRB TESTING.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 August 2016 Resolved
Life float lights were extinguished. Replace or repair.
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 23 August 2016
Resolution: new float lights were installed and tested all sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 August 2016 Resolved
Stern light is extinguished, Replace or repair.
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 23 August 2016
Resolution: New light was installed, and tested all sat.
Navigation › Collision/Grounding Avoidance › Radar
Issued 22 August 2016 Resolved
Vessel radar is inop. Prove proper operation.
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 23 August 2016
Resolution: Vessel was able to install updates and radar operates correctly. all sat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 August 2016 Resolved
PFD stowage does not match markings.
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 23 August 2016
Resolution: Stowage was remarked to reflect actual storage numbers.
Operations/Management › Drug and Alcohol Testing › Testing, Substances
Issued 22 August 2016 Resolved
Vessel does not have alcohol swabs onboard.
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 23 August 2016
Resolution: Alcohol swabs were purchased and kept onboard.

Recorded names · 1

ADVENTURER (2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record