02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 June 2020
Resolved
Prove depth of identified cracks to the satisfaction of
the attending marine inspector/provide repair proposal.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2021
Resolution: Cracks were ground and repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 June 2020
Resolved
Clean bilge area under engine room decking in order to
facilitate inspection of internal structure. Properly
dispose of any oil and wash water.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2021
Resolution: Oil removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 June 2020
Resolved
Remove grating to facilitate inspection of through hull
valves. Install valve handles on valves that do not have
handles.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2021
Resolution: All through hull valves were inspected satisfactorily.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 June 2020
No resolution recorded
Install positive shutoff valves at the overboard hull
penetration of submersible pumps.
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 26 June 2020
No resolution recorded
Present area forward of collision bulkhead that was
previously inaccessible for inspection.
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 26 June 2020
No resolution recorded
Test new collision bulkhead to a head of water to the
top of the bulkhead.
Action required: 17 - Rectify deficiencies prior to departure
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 26 June 2020
Resolved
Port side fuel tank vent is wasted in tank space. Make
repairs to the satisfaction of attending inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2021
Resolution: Fuel venting has been replaced satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 26 June 2020
No resolution recorded
There are non metallic pipes and conduits that penetrate
watertight bulkheads. Non metallic piping penetrating
watertight bulkhead requires a metallic bulkhead fitting
and a valve on both sides of the bulkhead or a single
valve if operable from above the bulkhead deck. Provide
proposal to modify.
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 June 2020
Resolved
Make areas under wasted battery trays available for
inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2021
Resolution: Wasted battery storage arrangements were removed and satisfactorily replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 26 February 2019
No resolution recorded
FWD Main deck over anchor compartment has damage due to sampson post being ripped out of the vessel along with sections of the deck.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 26 February 2019
No resolution recorded
Fwd deck over fwd compartment has unapproved repair and rot due to failed deck sealant. Repair decking.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 26 February 2019
No resolution recorded
Collision bulkhead has rot that was hidden by fiberglass and transverse deck beams. Bulkhead must be repaired.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2019
Resolved
Multiple exhaust leaks on both main diesel engines make the engine room and the main cabin unsafe during operations. Repair all exhaust leaks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: Both main diesel engines have been completely overhauled and all exhaust leaves repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2019
Resolved
Port engine aft engine mounts are missing hardware. Renew mounts and/or hardware.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: All hardware was renewed.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 26 February 2019
Resolved
Fire pump is frozen and inoperable. Repair/renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: New Fire pump was installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 February 2019
Resolved
All bilge high level alarms are required to have an audible and visual indicator at the operating station. all alarms are inoperable. Repair/renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: High level alarms were renewed and tested all sat.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 26 February 2019
Resolved
Bilge pump in the vessel's tank space is inoperable. Repair/renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: All bilge pumps have been renewed and tested all sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 February 2019
Resolved
EPIRB hydrostatic release is expired and must be renewed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: New hydrostatic release was installed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 February 2019
Resolved
Fire extinguisher must be visually inspected monthy, and have annual maintenance conducted. Inspection and maintenance have not been conducted. Prove inspections have been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: All fire equipment was inspected and is all sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 February 2019
Resolved
All drill, survival craft maintenance, and chemical testing logs are missing. Provide new logs and maintain them per the CFR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2021
Resolution: Cleared deficiency as the vessel has transferred ownership, has been out of service and will have to prove the same when the vessel is presented for inspection prior to operation.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 November 2017
Resolved
PROVIDE SERVICING REPORTS FOR FIXED FIRE SYSTEM. 46 CFR 181.410.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2017
Resolved 21 November 2017
Resolution: PROVIDED SERVICING REPORTS FOR FIXED FIRE SYSTEM.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 November 2017
Resolved
LABEL HIGH LEVEL ALARMS FOR EACH COMPARTMENT. 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: LABELED HIGH LEVEL ALARMS FOR EACH COMPARTMENT.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 14 November 2017
Resolved
PROVIDE TIDE TABLES FOR AREA OF OPERATION. 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: PROVIDED TIDE TABLES FOR AREA OF OPERATION.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 November 2017
Resolved
LABEL EACH SWITCH ON DISTRIBUTION PANEL. 46 CFR 183.330.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: LABELED EACH SWITCH ON DISTRIBUTION PANEL.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 14 November 2017
Resolved
PROVIDE FIRST AID KIT. 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: PROVIDED FIRST AID KIT.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 November 2017
Resolved
PROVIDE LANYARD FOR RING BUOY WATERLIGHT. 46 CFR 180.70(d)(2).
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: PROVIDED LANYARD FOR RING BUOY WATERLIGHT.
Lifesaving › Lifefloat › Paddle
Issued 14 November 2017
Resolved
LASH PADDLES ON 02 LIFE FLOATS. 46 CFR 180.137.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: LASHED PADDLES ON 02 LIFE FLOATS.
Lifesaving › Lifefloat › Serviceable
Issued 14 November 2017
Resolved
REPLACE LINES CONNECTING LIFE FLOATS TO WATERLIGHTS. 46 CFR 180.130.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: REPLACED LINES CONNECTING LIFE FLOATS TO WATERLIGHTS.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 14 November 2017
Resolved
REPLACE LIGHT IN 01 FLOAT LIGHT. 46 CFR 180.200.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: REPLACED LIGHT IN 01 FLOAT LIGHT.
Documentation › Markings/Placards › Lifejacket Placard
Issued 14 November 2017
Resolved
PROVIDE LIFEJACKET DONNING PLACARD. 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: PROVIDED LIFEJACKET DONNING PLACARD.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 November 2017
Resolved
INSTALL ENGINE GUARDS ON BOTH ENGINES. 46 CFR 183.220.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: INSTALLED ENGINE GUARDS ON BOTH ENGINES.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 14 November 2017
Resolved
PROVIDE PROOF OF CPR TRAINING FOR ALL CREW.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: PROVIDED PROOF OF CPR TRAINING FOR ALL CREW.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 November 2017
Resolved
RE-FASTEN NAV LIGHT (MAST HEAD) MOUNT.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: RE-FASTENED NAV LIGHT (MAST HEAD) MOUNT.
Operations/Management › Drills/Instruction › Fire
Issued 14 November 2017
Resolved
COMPLETE SATISFACTORY FIRE DRILL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2017
Resolved 21 November 2017
Resolution: COMPLETED SATISFACTORY FIRE DRILL.
Lifesaving › Lifebuoys › Serviceable
Issued 31 August 2017
Resolved
Life ring is no longer serviceable. Renew ring.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: RENEWED LIFE RING.
Navigation › Collision/Grounding Avoidance › Radar
Issued 31 August 2017
Resolved
Vessel's radar is inoperable. Install new radar and prove proper operation, prior to operating with more than 49 passengers.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: INSTALLED NEW RADAR AND PROVED OPERATION.
Navigation › Piloting/Steering › Magnetic Compass
Issued 31 August 2017
Resolved
Vessel compass is not lit. Repair/renew.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: COMPASS LIGHT OPERABLE.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 31 August 2017
Resolved
Sink drain is broken and all water drains directlyinto the bilge. Re-plumb system.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: RE-PLUMBED THE SINK DRAIN FOR PROPER DISCHARGE.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 31 August 2017
Resolved
Both main engine turbo V bands are missing. Provide new V bands.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: PROVIDED NEW V BANDS FOR BOTH MAIN ENGINE TURBOS.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 31 August 2017
Resolved
Shore tie connection on vessel is missing the back cover. Renew connection to provide a completely enclosed connection.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: INSTALL NEW COVER FOR SHORE TIE CONNECTION.
Electrical › Electric Generation Source (service) › Panelboard
Issued 31 August 2017
Resolved
Generator distribution panel is missing one side. Close entire panel to provide shock protection.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: CLOSED ENTIRE DISTRIBUTION PANEL.
Electrical › Electric Generation Source (service) › Panelboard
Issued 31 August 2017
Resolved
Generator control panel is missing the AMP meter. Provide new AMP meter, and prove proper operation.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: PROVIDED AMP METER.
Documentation › Logs/Records › Logbook (official)
Issued 31 August 2017
Resolved
VEssel does not have a log for life saving maintenance or for monthly EPIRB testing. Provide log.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 November 2017
Resolution: PROVIDED LOGBOOK FOR LIFE SAVING MAINTENANCE FOR MONTHLY EPIRB TESTING.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 August 2016
Resolved
Life float lights were extinguished. Replace or repair.
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 23 August 2016
Resolution: new float lights were installed and tested all sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 August 2016
Resolved
Stern light is extinguished, Replace or repair.
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 23 August 2016
Resolution: New light was installed, and tested all sat.
Navigation › Collision/Grounding Avoidance › Radar
Issued 22 August 2016
Resolved
Vessel radar is inop. Prove proper operation.
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 23 August 2016
Resolution: Vessel was able to install updates and radar operates correctly. all sat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 August 2016
Resolved
PFD stowage does not match markings.
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 23 August 2016
Resolution: Stowage was remarked to reflect actual storage numbers.
Operations/Management › Drug and Alcohol Testing › Testing, Substances
Issued 22 August 2016
Resolved
Vessel does not have alcohol swabs onboard.
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 23 August 2016
Resolution: Alcohol swabs were purchased and kept onboard.