Records from 1985 to 1998. Most recent: inspection, 19 March 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
19 March 1998
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 774297
20 May 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 773451
16 April 1997
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1464028
16 May 1996
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1367746
10 April 1995
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1168868
4 April 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1168061
28 May 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1148470
21 April 1993
Hull Examination · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 835704
14 April 1992
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 962470
4 June 1991
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1311837
19 April 1991
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 923826
24 May 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1224422
24 April 1990
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 921256
30 June 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1202858
15 June 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1339031
9 May 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 894773
29 March 1989
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1040327
1 August 1988
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1345997
10 May 1988
Deficiency Check · Hull Examination · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1352145
14 April 1987
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1004982
30 April 1986
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1307810
17 April 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 979795
Fire Fighting
Issued 16 April 1997
Resolved
Prove proper hydrostatic test of fixed flooding system's 20 lb CO2 bottle.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Engineering
Issued 16 April 1997
Resolved
Properly mark emergency fuel shut off valve.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Lifesaving
Issued 21 April 1993
Resolved
PUT VESSEL MISSOURI NUMBERS ON RING LIFE BOUY.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Lifesaving
Issued 21 April 1993
Resolved
PUT VESSEL MISSOURI NAME/NUMBERS ON LIFE JACKETS.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Construction/Loadline
Issued 21 April 1993
Resolved
PUT ONBOARD HAND BILGE/FIRE PUMP.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Construction/Loadline
Issued 19 April 1991
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE INSTALL; FLOOR BOARDS, FIXED SEATING,FIXED FIRE FIGHTING SYSTEMS, RING BOUY WITH 60 FEET OF LINE, LIFE PRESERVERS, AND HAND BILGE PUMP.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Lifesaving
Issued 19 April 1991
Resolved
RESTENCIL VESSEL NAME ON RING BOUY AND VESSEL STERN.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Fire Fighting
Issued 24 April 1990
Resolved
SERVICE ALL FIXED CO2 SYSTEMS.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Documentation
Issued 24 April 1990
Resolved
MOUNT CERTIFICATE OF INSPECTION WITH BOTH PAGES VISIBLE TO PASSENGERS.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Engineering
Issued 24 April 1990
Resolved
REPAIR BILGE PUMP PORT SIDE AFT.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Engineering
Issued 24 April 1990
Resolved
PROVIDE DOUBLE HOSE CLAMPS ON FUEL LINES.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Lifesaving
Issued 24 April 1990
Resolved
RE-STENCIL LIFE PRESERVERS WITH PROPER VESSEL NAME.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Lifesaving
Issued 24 April 1990
Resolved
STOW ALL LIFE PRESERVERS.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Accommodation/Occupational Safety
Issued 24 April 1990
Resolved
INSTALL FIXED SEATING.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Electrical
Issued 24 April 1990
Resolved
INSTALL BATTERY HOLD DOWN CLAMP.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Fire Fighting
Issued 9 May 1989
Resolved
PROVIDE THE FOLLOWING INFORMATION FOR EACH CO2 SYSTEM INSTALLED: CYLINDER SER. NO., CYLINDER WEIGHT - EMPTY AND FULL, AND DATE OF HYDRO TEST.
Condition: Unknown
Due 9 May 1989
Resolved 9 May 1989
Fire Fighting
Issued 9 May 1989
Resolved
PROVIDE COMPLETE BUT SIMPLE INSTRUCTIONS FOR THE OPERATION OF EACH FIXED CO2 SYSTEM AND POST AT THE BOTTLE.
Condition: Unknown
Due 9 May 1989
Resolved 9 May 1989
Fire Fighting
Issued 29 March 1989
Resolved
PROVIDE HAND BILGE PUMP.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Documentation
Issued 29 March 1989
Resolved
POST EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Engineering
Issued 29 March 1989
Resolved
INSTALL AND LABEL FUEL SHUT OFF VALVE.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Documentation
Issued 29 March 1989
Resolved
INSTALL RED WARNING SIGN FOR BLOWER SWITCH.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Documentation
Issued 29 March 1989
Resolved
POST POLLUTION PLACARD.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Engineering
Issued 29 March 1989
Resolved
REPAIR/REMOUNT ENGINE COMPARTMENT VENT BLOWER.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Engineering
Issued 29 March 1989
Resolved
PROPERLY MOUNT BACKFIRE FLAME ARRESTOR.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Construction/Loadline
Issued 29 March 1989
Resolved
INSTALL GASKET ON FORWARD HATCH.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Fire Fighting
Issued 29 March 1989
Resolved
PROVIDE PLANS AND LIST OF MATERIAL FOR CHANGES TO FIXED CO2 SYSTEM.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Construction/Loadline
Issued 10 May 1988
Resolved
REPLACE PACKING TO RUDDER TUBE AND CONDUCT OPERATIONAL TEST.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Construction/Loadline
Issued 10 May 1988
Resolved
REPLACE PACKING TO STERN TUBE AND CONDUCT OPERATIONAL TEST.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Construction/Loadline
Issued 10 May 1988
Resolved
RENEW GASKETS AND DOGS TO FWD HATCH COVERS
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988