← All vessels
SILVERFJORD
Freight Ship · General Dry Cargo Ship class · Built 1970s · USCG Heartland District (CGD-H) · Other hulls named SILVERFJORD
SILVERFJORD is a 1972 freight ship. The Coast Guard has recorded 36 inspections since 1986, most recently in October 2008, along with 9 deficiencies and 10 operational controls.
Records from 1986 to 2008. Most recent: inspection, 1 October 2008.
- Built
- 1972
- Last inspected
- 1 October 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7115048 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9VYL
248374
Flag
LIBERIA
—
Maury page id
psix-248374
Inspections, by type
…with no type recorded20
Years with a record
12 calendar years (1986–2008)
The 36 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it9003 - Convention (Subpart B), Net Ton
31507 - Dead Weight, Ton
41400 - Displacement, Ton
20578 - Convention (Subpart B), Gross Ton
31507 - Dead Weight, Ton
41400 - Displacement, Ton
20578 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 36
1 October 2008
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3336604
1 July 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3253711
2 June 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3225325
13 May 2008
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3205654
5 March 2008
MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3158359
18 February 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3149417
8 February 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3144312
10 October 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3077519
14 September 2007
Random ISPS/MTSA/PSC · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3057371
26 February 2007
Random ISPS/MTSA/PSC
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2877593
19 February 2007
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2874066
31 January 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2865041
20 October 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2804777
12 July 2006
ISPS III Exam · MARPOL Annex I Examination · NPV Safety Exam · MARPOL Annex V Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2710038
11 July 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2709089
10 July 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2707908
26 June 2006
PII Safety Exam · ISPS III Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2690961
29 September 2005
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2507346
8 June 2005
Ballast Water Examination · NPV Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2384113
18 November 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2246981
16 July 2004
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2135464
18 December 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1966388
29 November 2003
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1956286
14 May 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1794876
3 April 2002
In-Service Inspection · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1600673
2 December 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1486744
8 May 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 289684
26 January 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 286703
5 June 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 771868
26 May 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 278336
9 May 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 277773
1 May 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 191542
4 February 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 274415
31 March 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 427138
26 December 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 423811
9 January 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 306353
Deficiency record · 9
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 2 June 2008
Resolved
Vessel reported emergency fire pump was inoperable on NOA. Temporary portable pump was installed on the vessel and tested to the satisfaction of class. Permanent repairs to be affected NLT 30JUN08.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 5 March 2008
Resolved
The Deck Line Mark is not painted in a contrasting color to the ship. The mark is currently black which is the same color as the hull.
Lifesaving › Launching Appliances › Davit
Issued 5 March 2008
Resolved
Forward limit switch on the port side lifeboat assembly is corroded. During the evolution of raising the lifeboat from the embarkation deck, the limit switch assembly fell off. Vessel temporarily repaired the assembly. Have GL verify to proper permanent repairs. SOLAS 60 III/36(k)
Engineering › Sea-water System (primary cooling) › Pump
Issued 5 March 2008
Resolved
The bracket for the cooling water supply pump for the main generators is wasted/corroded.
Operations/Management › Pollution › Control of Garbage
Issued 5 March 2008
Resolved
Entries in the garbage record book are not in accordance with the garbage management plan. Specifically the entries for discharges to reception facilities. Rectify to the satisfaction of the Administration. MARPOL 2006 Annex V/9
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 5 March 2008
Resolved
Vessel does not have current copies of the applicable United States' Code of Federal Regulations (CFRs). Copies on board date from 2002. To the satisfaction of the Coast Guard.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 12 July 2006
Resolved
Machinery space not free from excess oil: Tank tops and bilges not free of excessive oil or other fire hazards (oil waste & residue and oil soaked lagging). Puddled oil located IVO purifiers. Excessive oily residue on surfaces of generators and main. Repair to the satisfaction of the ADMINISTRATION.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 29 November 2003
Resolved
Vessel suffered reduction in power due to #1 cylinder not firing. Detained vessel under COTP order. Class report attesting to satisfactory repairs required prior to departure.
Fire Fighting
Issued 26 December 1998
Resolved
Fire plans should be ammended to show locations of international shore connection._x001C_ Solas 74(A) II-2/19
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.