Behind this panel: 15 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 15
1 July 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8172386
20 February 2025
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8082130
20 May 2024
Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7912954
29 September 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7793976
10 January 2023
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7619417
16 August 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7536351
10 August 2021
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7282229
19 January 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7126536
24 August 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7041871
13 August 2019
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6775885
31 January 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6617981
2 August 2018
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6498723
3 August 2017
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6229445
5 December 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6053389
1 August 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5959678
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 July 2025
Resolved
Vessel operator must provide evidence of the required servicing for fixed-gas fire extinguishing systems. The fireboy was replaced last year but has not had its annual servicing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2025
Resolved 5 August 2025
Resolution: Fireboy has been serviced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 July 2025
Resolved
A submersible electric bilge pump may be used as a power bilge pump. The bilge pump in the forward space is inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2025
Resolved 5 August 2025
Resolution: Bilge is now operational.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 July 2025
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. The high water bilge alarm is inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2025
Resolved 5 August 2025
Resolution: Alarm is operable.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 1 July 2025
Resolved
Sufficient drills shall be conducted to ensure all crew members are familiar with their duties during emergencies. MOB and fire drill has not been conducted since last year.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2025
Resolved 5 August 2025
Resolution: Drills were conducted with all operators.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 1 July 2025
Resolved
Vessel must carry a first aid kit. Medication in first aid kit was expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2025
Resolved 5 August 2025
Resolution: First aid kit has been updated.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 May 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must: automatically shut down all engines that draw intake air from within the protected space. The engine did not shutdown when testing the fireboy.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2024
Resolved 29 May 2024
Resolution: Operator submitted video of satisfactory fireboy shutdown and override test.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 September 2023
Resolved
The following spaces must be equipped with a fixed gas extinguishing system: a space containing propulsion machinery and a space containing an internal combustion engine of more than 50 hp. The vessel's fixed extinguishing system was completely missing. Reinstall system and have serviced prior to the carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2024
Resolution: Operator provided photos of newly installed fireboy.
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 16 August 2022
Resolved
Employers must maintain records of chemical tests and must make these records available to Coast Guard officials upon request. Employer was unable to retrieve pre-employment chemical test for licensed mariner. Provide pre-employment chemical testing record.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2022
Resolved 23 August 2022
Resolution: Validated Pre-Employment screening of licensed mariner.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 August 2022
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in a machinery space bilge. Bilge alarm did not make an audible or visual indication during testing. Witness satisfactory test of high level bilge alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2022
Resolved 23 August 2022
Resolution: Witnessed satisfactory testing of high level bilge alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 August 2022
Resolved
A ring life buoy must contain a grab line having a minimum breaking strength of 1,350 pounds. Grab line was found to be frayed and worn. Replace grab line around ring life buoy.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2022
Resolved 23 August 2022
Resolution: Witnessed new grab line around ring buoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 August 2022
Resolved
Vessels not required to have a power driven fire pump must have at least three 2.5 gallon buckets with an attached lanyard. Vessel only had one fire bucket. Provided two additional fire buckets.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2022
Resolved 23 August 2022
Resolution: Witnessed (3) Fire Buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 August 2020
Resolved
Vessel life buoy is not in serviceable condition. Life line around the life buoy is deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 25 August 2020
Resolution: Vessel rep acquired and installed a new life buoy with new life line fixed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 August 2019
Resolved
Fixed fire fighting system needs an annual inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2019
Resolved 15 August 2019
Resolution: Vessel rep provided documentation of fixed firefighting service.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 1 August 2016
Resolved
Replace T-handle from engine compartment Fire-boy manual pull.
Due 1 September 2016
Resolved 8 August 2016
Resolution: T-handle replaced.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 1 August 2016
Resolved
Provide tamper seal for Fire-boy manual pull.
Due 1 September 2016
Resolved 8 August 2016
Resolution: Tamper seal installed.