RE#5 is a 1985 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2016, most recently in September 2025, along with 5 deficiencies.
Records from 2016 to 2025. Most recent: inspection, 10 September 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it3 - Simplified, Net Ton 4 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 11
10 September 2025COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8179123
11 September 2024Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7997378
7 September 2023Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7789849
7 September 2023Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7789851
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 September 2019Resolved
Replace corroded fire extinguisher aft.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2019
Resolved 26 September 2019
Resolution: Picture received.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 12 September 2019Resolved
Properly cover J-box openings above operator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2019
Resolved 30 September 2019
Resolution: Picture received.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 12 September 2019Resolved
Replace covers on both accom lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2019
Resolved 30 September 2019
Resolution: Picture received.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 12 September 2019Resolved
Mouse shackle pins on both anchors.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2019
Resolved 26 September 2019
Resolution: Picture received.
Construction/Loadline › Hull › Transverse Frame
Issued 8 September 2016Resolved
Noted a crack in transom during inspection
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2016
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.