MAURY USCG vessel records Sign in
← All vessels

LADY EM

LADY EM is a 1985 passenger vessel (inspected). The Coast Guard has recorded 78 inspections since 1985, most recently in January 2026, along with 73 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 30 January 2026.

Built
1985
Last inspected
30 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE8162
248607
Flag
UNITED STATES
367402270
Maury page id
psix-248607

Inspections, by type

…with no type recorded10
Years with a record 39 calendar years (1985–2026)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)59.0 ft × 18.4 ft × 12.0 ft
Registered tonnagegross 91 / net 72
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderG & S BOATS INC · DESTIN, FL, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 16 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it72 - Simplified, Net Ton
91 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE8162MMSI 367402270 · active · compulsorily equipped · granted 5 March 2019, expires 1 April 2029
WSK8602MMSI 367342870 · expired · compulsorily equipped · granted 14 March 2008, cancelled 21 July 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 78

30 January 2026 Administrative Inspection · Vessel Attendance · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8303887
10 December 2025 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8276194
7 April 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8106694
13 March 2024 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7879105
6 February 2024 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7862037
12 December 2023 Administrative Inspection · Special
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7838142
8 December 2023 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7836574
27 July 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7754100
16 March 2023 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7651782
22 February 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7640661
17 August 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7537173
6 August 2022 Type not recorded
No type recorded · USCGC JACOB POROO (WPC 1125) · USCG Heartland District (CGD-H) · Activity 7541891
22 February 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7400220
14 December 2021 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7369006
30 September 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7323670
16 February 2021 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7141125
3 March 2020 DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6919130
1 March 2020 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6918528
3 December 2019 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6874661
24 September 2019 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6823032
28 March 2019 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6651776
21 February 2019 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6630421
24 September 2018 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6547363
15 February 2018 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6350606
7 December 2017 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6315008
11 April 2017 DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6117591
3 October 2016 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6015797
14 January 2016 Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5797206
23 October 2015 Hull Examination · Administrative Inspection · Internal Structural Exam · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5749399
17 May 2012 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4302036
1 February 2012 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4236300
16 December 2010 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3910681
11 February 2010 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3678215
2 April 2009 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3440867
15 December 2008 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3378715
1 April 2008 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3173225
5 April 2007 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2989620
13 April 2006 Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2623761
16 May 2005 Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 3717933
15 February 2005 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2292726
14 December 2004 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2258406
12 April 2004 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2042782
15 December 2003 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1964372
14 May 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1794037
15 April 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1773315
12 November 2002 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1704070
30 April 2002 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1611297
24 April 2002 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1608571
23 May 2001 Type not recorded
No type recorded · CGC POINT LOBOS · USCG Heartland District (CGD-H) · Activity 1521151
17 April 2001 Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1473447
17 February 2000 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 818175
26 October 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 794114
11 April 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1450281
17 February 1999 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1346482
1 December 1998 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1440058
12 May 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446654
11 March 1997 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1454437
5 September 1996 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1409562
25 April 1996 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1398448
16 March 1995 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1405669
18 October 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1401957
27 September 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1444889
14 March 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1168840
19 May 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1140687
17 March 1993 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 837896
8 March 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1145001
1 October 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 951152
25 March 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 949710
20 March 1991 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 927782
7 March 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 907178
13 September 1989 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1350818
9 March 1989 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1202598
23 March 1988 Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1349961
21 May 1987 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1337746
2 October 1986 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1321098
31 March 1986 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1000053
27 December 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 989761
28 March 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1289441

Deficiency record · 73

01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 12 December 2023 Resolved
Fixed ballast was discovered in the stern of the vessel. There is no history/documentation of this ballast being allowed.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2024
Resolution: Received objective evidence that fixed ballast was removed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 March 2020 Resolved
Penetrations in bulkhead are not vapor-tight between machinery space and lazarrette. Penetrations must be made vapor-tight to allow pre-engineered extinguishing system to be adequately effective in machinery space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 March 2020 Resolved
Ring life buoy has deteriorated significantly. Repair or replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2020
Resolution: Replaced
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 March 2020 Resolved
Safety Radiotelephony Certificate expired 17APR19. Vessel must have a valid Safety Radiotelephony Certificate. Acquire a valid Safety Radiotelephony Certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2020
Resolution: Acquired
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 March 2020 Resolved
Bonding wire connecting to zinc plate on transom was broken off. Repair to make bonding wire intact as per original design.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2020
Resolved 10 March 2020
Resolution: Repaired terminal end
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 March 2020 Resolved
One of the three fire buckets is missing the attached lanyard. All fire buckets must have an attached lanyard long enough to allow the bucket to reach the water. Attach an appropriate length lanyard to the fire bucket
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2020
Resolved 10 March 2020
Resolution: Attached
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 March 2020 Resolved
The ring life buoy waterlight corrosion resistant clip does not stay closed, posing a retention risk. Repair or replace so that the clip remains normally closed and can be quickly disconnected.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2020
Resolution: Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 September 2019 Resolved
Vessel is required to have waterlight secured to ring buoy body with a corrosive resistant quick release clip. Vessel had clip attached directly to the waterlight which prevents a quick rlease. Vessel to resplice line to allow clip to be used with line around the body of the life buoy. 46 CFR 180.70 (c)(2)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2019
Resolved 24 September 2019
Resolution: Crew properly attached waterlight to ring buoy using appropriate line and a corrosion resistant quick release clip.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 September 2019 Resolved
Vessel is required to mark emergency eit on both sides in letters 1" high EMERGENCY EXIT - KEEP CLEAR. Vessel did not include keep clear. Vessel to add additional wording. 46 CFR 177.15
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2019
Resolved 24 September 2019
Resolution: Crew marked emergency escape on both sides as required.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 September 2019 Resolved
Vessel is required to have one class 10 B-C fire extinguisher in the wheel house. Extinguisher onboard has not been serviced. Vessel to provide one class 10 B-C extinguisher in wheelhouse. 46 CFR 181.30
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2019
Resolved 24 September 2019
Resolution: Captain purchased new 10 B-C fire extinguisher and mounted it in the wheelhouse as required.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 September 2019 Resolved
Vessel has many pieces of equipment in wheelhouse powered by portable electric cords. Vessel shall install permanent outlets in the number needed to power equipment and or applicances deemed necessary for shipboard operations. 46 CFR 183.01-5
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2019
Resolved 3 December 2019
Resolution: Deficiency verified rectified during drydock/ISE
Lifesaving › Lifebuoys › Stowage
Issued 11 April 2017 Resolved
Replace ring buoy waterlight bracket
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 24 April 2017
Resolution: Vessel replaced bracket
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 11 April 2017 Resolved
Provide alcohol test equipment
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 24 April 2017
Resolution: Vessel provided alcohol test equipment
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 April 2017 Resolved
Provide manufacture information on masthead light to ensure it meets requirement
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 24 April 2017
Resolution: Vessel provided information
Engineering › Bilge Water Management System › Interface Detector
Issued 26 January 2016 Resolved
Repair/replace fwd high water alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2016
Resolved 23 February 2016
Resolution: Vessel repaired alarm
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 January 2016 Resolved
Replace anchor light
Action required: 705 - Other - as specified
Due 23 February 2016
Resolved 23 February 2016
Resolution: Vessel replaced light
Engineering › Fuel Oil Service System › Valve
Issued 26 January 2016 Resolved
Reinstall fuel shut off valves and label
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2016
Resolved 23 February 2016
Resolution: Vessel reinstalled valves and labeled
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 January 2016 Resolved
Provide first aid kit
Action required: 705 - Other - as specified
Due 23 February 2016
Resolved 23 February 2016
Resolution: Vessel provided kit
Lifesaving › Lifefloat › Not on Board
Issued 26 January 2016 Resolved
Provide lifefloat
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2016
Resolved 23 February 2016
Resolution: Vessel provided lifefloat
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 26 January 2016 Resolved
Hook up generator and test
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2016
Resolved 23 February 2016
Resolution: Vessel hooked up and tested
Electrical › Electrical Distribution System (service) › Junction Box
Issued 26 January 2016 Resolved
Repair junction box in steering compartment.
Action required: 705 - Other - as specified
Due 23 February 2016
Resolved 23 February 2016
Resolution: Vessel repaired box
Stability › Watertight Integrity › General
Issued 11 February 2010 Resolved
Repair and prove tightness of aft deck hatch by means of a hose test of at least 30 psi to the satisfaction of the attending marine inspector.
Due 18 February 2010
Resolved 18 February 2010
Resolution: Witnessed satisfactory hose test of aft deck hatch after gasket was renewed and securing mechanism was properly adjusted.
Electrical › Electric Generation Source (service) › Generator
Issued 11 February 2010 Resolved
Repair and prove operation of forward ship service generator under a loaded condition to the satisfaction of the attending marine inspector.
Due 18 February 2010
Resolved 18 February 2010
Resolution: Witnessed satisfactory operation of ship service generator under a fully loaded condition once the battery power source was renewed.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 11 February 2010 Resolved
Provide evidence that the vessels user fees have been paid.
Due 18 February 2010
Resolved 18 February 2010
Resolution: Owner/operator provided a copy of the check and postage receipt to satisfy user fee obligation.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 11 February 2010 Resolved
Install 20 man inflatable liferaft with hydrostatic release on bow of vessel to the satisfaction of the attending marine inspector.
Due 18 February 2010
Resolved 18 February 2010
Resolution: Examined and found satisfactory the installation of inflatable liferaft and hydrostatic release installation.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 11 February 2010 Resolved
Provide lights to two adult life jackets to the satisfaction of the attending marine inspector.
Due 18 February 2010
Resolved 18 February 2010
Resolution: Examined the two operational lights on the adult life jackets.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 February 2010 Resolved
Renew securing clasp to one adult life jacket to the satisfaction of the attending marine inspector.
Due 18 February 2010
Resolved 18 February 2010
Resolution: New securing clasp was installed and found satisfactory.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 11 February 2010 Resolved
Provide two additional adult life jackets on board vessel for total of 26 adult life jackets.
Due 18 February 2010
Resolved 18 February 2010
Resolution: Examined and found satisfactory two additional USCG Approved Type I life jackets.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 February 2010 Resolved
Remark life jacket storage locker to indicate the aggregate amount of life jackets contained within for a total of twenty-six adult life jackets.
Due 18 February 2010
Resolved 18 February 2010
Communications › Radio Communications › EPIRB
Issued 11 February 2010 Resolved
Renew expired hydrostatic release to EPIRB.
Due 18 February 2010
Resolved 18 February 2010
Resolution: Examined and found satisfactory newly installed hydrostatic release.
Navigation › Piloting/Steering › Marine Charts
Issued 11 February 2010 Resolved
Update all nautical publications and charts to the most current notice to mariners.
Due 18 February 2010
Resolved 18 February 2010
Resolution: All charts and publications were updated and found satisfactory.
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 February 2010 Resolved
Clean battery terminals to starboard battery bank in engune room compartment to the satisfaction of the attending marine inspector.
Due 18 February 2010
Resolved 18 February 2010
Accommodation/Occupational Safety › Ventilation › General
Issued 11 February 2010 Resolved
Provide a means to secure ventilation closure/louver to machinery space protected by a fixed fire suppression system to ensure vapor tightness.
Due 18 February 2010
Resolved 18 February 2010
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 April 2009 Resolved
Provide current certificate of documentation.
Due 2 May 2009
Resolved 8 April 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 April 2009 Resolved
Repair starboard running light.
Due 2 May 2009
Resolved 8 April 2009
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 2 April 2009 Resolved
Repair forward high water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Fire Fighting › Ventilation Systems › Ducts
Issued 2 April 2009 Resolved
Provide ventilation shut downs for engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Construction/Loadline › Hull › Side Shell
Issued 15 December 2008 Resolved
Repair two blisters marked on starboard side of hull.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2009
Construction/Loadline › Hull › Bracket
Issued 15 December 2008 Resolved
Refasten transducer for depth sounder on starboard side of hull.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2009
Construction/Loadline › Hull › Keel
Issued 15 December 2008 Resolved
Remove bad fiberglass, and relaminate new fiberglass onto keel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 15 December 2008 Resolved
Replace starboard main diesel engine thru-hull valve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2009
Communications › Radio Communications › EPIRB
Issued 5 April 2007 Resolved
Replace cracked EPIRB antennae. 46CFR180.64
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2007
Communications › Audible Communications › Horn/Whistle
Issued 5 April 2007 Resolved
Demonstrate an audible sound producing device. COLREGS
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 5 April 2007 Resolved
Post "Emergency Broadcast Placard". 46CFR184.506
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 April 2007 Resolved
Deckhand "[name withheld]" to enroll in a program prior to carrying passengers. 46CFR16
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 April 2006 Resolved
Demonstrate proper operation of engine shutdowns connected to the fixed fire extinguishing system as required by 46 CFR 182.465(h).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 April 2006
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 12 April 2004 Resolved
Provide hydrostatic release for life raft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2004
Resolved 13 April 2004
Resolution: Corrected during course of inspection.
Documentation › Certificates/Documents
Issued 15 April 2003 Resolved
Post the Certificate of Inspection with all pages visible. LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 14 May 2003
Resolution: Owner posted COI with all pages visible.
Navigation › Piloting/Steering
Issued 15 April 2003 Resolved
Provide current charts and publications, i.e., light list, tide tables, current tables. LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 14 May 2003
Resolution: Owner provided current charts and publications.
Communications › Audible Communications
Issued 15 April 2003 Resolved
Provide Bell as required by 33 CFR part 86 and 72 COLREGS. LEGACY COMPONENT DESC: Bell
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 14 May 2003
Resolution: Owner provided bell as required.
Documentation › Logs/Records
Issued 15 April 2003 Resolved
Provide Log Book and up to date monthly inspections of EPIRB test. LEGACY COMPONENT DESC: Transfer Equipment Test/Inspection Records
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 14 May 2003
Resolution: Owner provided Log Book and up to date inspections.
Communications › Radio Communications
Issued 15 April 2003 Resolved
Provide Emergency Broadcast placard. LEGACY COMPONENT DESC: VHF Radiotelephone
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 14 May 2003
Resolution: Owner provided Emergency Broadcast Placard.
Communications › Visual Communication
Issued 15 April 2003 Resolved
Provide visual high level alarm indicator for lazarette.
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 14 May 2003
Resolution: Owner provided visual high level alarm for lazarette.
Communications › Radio Communications
Issued 15 April 2003 Resolved
Provide Hydrostatic release for EPIRB no later than 30 APR 03. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 14 May 2003
Resolution: Owner provided Hydro release for EPIRB.
Construction/Loadline
Issued 17 April 2001 Resolved
INSTALL BILGE HIGH LEVEL ALARM IN FOREWARD PORT V-BERTH IAW 46CFR182.530 PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 24 April 2001
Resolved 7 June 2001
Accommodation/Occupational Safety
Issued 17 April 2001 Resolved
PROVIDE DECK RAILS IN WAY OF ANCHOR HANDLING AREA IAW 46CFR177.900.
Condition: Unknown
Due 24 April 2001
Resolved 6 June 2001
Lifesaving
Issued 17 April 2001 Resolved
RENEW HYDROSTATIC RELEASE FOR EPIRB IAW 46CFR180.728 PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 24 April 2001
Resolved 6 June 2001
Lifesaving
Issued 17 April 2001 Resolved
RENEW HYDROSTATIC RELEASE FOR LIFERAFT PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 24 April 2001
Resolved 6 June 2001
Documentation
Issued 16 March 1995 Resolved
PROVIDE A WRITTEN STATEMENT DESIGNATING THE SENIOR DECKHAND AS REQUIRED BY NVIC 1-91.
Condition: Unknown
Due 16 April 1995
Resolved 7 April 1995
Navigation
Issued 16 March 1995 Resolved
PROVIDE A DEVIATION TABLE FOR THE MAGNETIC COMPASS.
Condition: Unknown
Due 16 April 1995
Resolved 7 April 1995
Construction/Loadline
Issued 27 September 1994 Resolved
REPLACE HOSE CLAMPS ON FISHBOX OVERFLOW DRAIN AND BILGE PIPING SYSTEM.
Condition: Unknown
Due 18 October 1994
Resolved 17 November 1994
Electrical
Issued 27 September 1994 Resolved
REPLACE BOTH PORT/STBD BATTERY BOXS DUE TO WASTAGE.
Condition: Unknown
Due 18 October 1994
Resolved 17 November 1994
Electrical
Issued 27 September 1994 Resolved
REPLACE MISSING SCREWS ON 110AC ELECTRICAL PANEL BOX.
Condition: Unknown
Due 18 October 1994
Resolved 17 November 1994
Accommodation/Occupational Safety
Issued 27 September 1994 Resolved
PROVIDE A 3/4 LEVEL INDICATOR ON MSD TANK
Condition: Unknown
Due 18 October 1994
Resolved 17 November 1994
Engineering
Issued 14 March 1994 Resolved
REPAIR EXHAUST WATER LEAK TO FWD SHIP SERVICE GENERATOR.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Electrical
Issued 14 March 1994 Resolved
INSTALL AND PROVE OPERATION OF A/C GENERATOR FREQUENCY METER.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Electrical
Issued 14 March 1994 Resolved
PROVE OPERATION OF AFT SHIP SERVICE GENERATOR._x001C_
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Navigation
Issued 14 March 1994 Resolved
PROVE OPERATION OF PORT RUNNING LIGHT.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Engineering
Issued 14 March 1994 Resolved
CLEAN AND REATTACH BONDING STRAP TO BOTH PORT/STBD FUEL OIL TANK FILL PIPING.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Electrical
Issued 17 March 1993 Resolved
VESSELS ALTERNATING CURRENT GENERATOR SHALL BE PROVIDED WITH A MEANS FOR MEASURING FREQUENCY. SEE 46 CFR 183.10-5
Condition: Unknown
Due 17 March 1993
Resolved 17 March 1993
Lifesaving
Issued 20 March 1991 Resolved
RENEW AND PROVE OPERATION OF EPIRB
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Unknown
Issued 23 March 1988 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Documentation
Issued 2 October 1986 Resolved
IAW 46CFR171.030 VESSEL IS TO UNDERGO A SIMPLIFIED STABILITY TEST IN THE PRESENCE OF AN ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986

Ownership record