MAURY USCG vessel records
← All vessels

REELISTIC

Built
1985
Last inspected
20 April 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 April 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM9620
248632
Flag
UNITED STATES
Maury page id
psix-248632

Documentation record

Registered dimensions (L × B × D)60.0 ft × 19.0 ft × 7.0 ft
Registered tonnagegross 55 / net 44
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBONNER YACHTS · WETUMPKA, AL, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPANAMA CITY, FL
Endorsements, as the file codes themcw_un, fi, rec, reg
DocumentationValid · issued 17 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Net Ton
55 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 29 inspections, each with its date, unit and type; 46 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 29

20 April 2026 Internal Structural Exam · Vessel Attendance · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8352513
7 January 2026 Administrative Inspection · Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8291578
3 September 2025 Special Consideration · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8226486
15 April 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8112126
26 March 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7885028
11 January 2024 Administrative Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7844290
31 October 2023 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7818221
19 October 2023 Special · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7811249
4 May 2023 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7681100
10 March 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7649095
3 May 2022 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7442520
24 June 2021 Administrative Inspection · Damage Survey · Internal Structural Exam · Drydock Exam · Construction Oversight
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7246931
15 January 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7125247
14 October 2020 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7076939
5 October 2020 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7071668
10 September 2020 Type not recorded
No type recorded · USCGC GANNET (WPB 87334) · USCG Southeast District (CGD-SE) · Activity 7056267
24 August 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7042166
5 November 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6849464
17 September 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814348
26 April 2019 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6671140
15 April 2019 Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6662819
14 September 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6540585
22 May 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6420741
31 January 2018 Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6347141
12 December 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6329085
20 March 2017 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6108096
18 April 2016 Administrative Inspection · Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5858316
8 March 2016 COI Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5863423
27 January 2016 Administrative Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5804802

Deficiency record · 46

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 March 2023 Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46CFR181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 4 May 2023
Resolution: Interconnected fire detection provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 March 2023 Resolved
Vessel was found with dual bilge pumps discharging into single overboard through-hull fitting with a check valve installed. IAW manufactures recommended installation pump are not allow check valves and need independent discharge port. Vessel allow to operate until next dry-dock to have items corrected.
Action required: 705 - Other - as specified
Resolved 26 March 2024
Resolution: Completed an Annual Inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 March 2023 Resolved
Vessels life-float was found with wasted SOLAS reflective. Replace tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2023
Resolved 4 May 2023
Resolution: Solas Tape renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 March 2023 Resolved
Vessel bowmar hatch covers over Fuel oil compartment were missing lanyard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2023
Resolved 4 May 2023
Resolution: Lanyards replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 March 2023 Resolved
Vessel electrical panels were missing breaker identification.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2023
Resolved 4 May 2023
Resolution: Breakers labeled.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 March 2023 Resolved
Vessel was found with numerous openings in aft bulkhead of fuel/oil compartment. Fill opening to satisfaction of attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2023
Resolved 4 May 2023
Resolution: Bulkhead openings sealed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 October 2020 Resolved
no repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requirements in this chapter are met. The procedures to be followed in notifying the Coast Guard about vessel repairs vary according to the type of vessel and service in which engaged. Vessel owner/operator notified CG that the vessel suffered damage due to Hurricane Sally in accordance with applicable regulatory cite. Vessel must make permanent repair/alteration to the satisfaction of the OCMI in accordance with 46 CFR 176.700(a).
Action required: 705 - Other - as specified
Resolved 25 February 2022
Resolution: Repairs completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2019 Resolved
Outlets show open ground when tested. Provide groudning for outlets. Noted open grounds on all outlets and reverse polarity on forward engine room outlet. Must be completed by 10/21/2019.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2019
Resolved 5 November 2019
Resolution: Outlets Tested for open grounds/faulty electrical. No issues observed, ALL SAT
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 May 2019 Resolved
Navigation Publications: Coast Pilot [name withheld], Tide Tables, Current Tables are not up-to-date. Replace with updated publications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2019
Resolved 4 June 2019
Resolution: Owner and deckhand demonstrated that the up to date navigation publications had been properly downloaded onto their phones for use while underway
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 May 2019 Resolved
STBD running light has 02 of 03 bulbs burnt out. Replace bulbs so STBD light functions as designed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2019
Resolved 4 June 2019
Resolution: Observed starboard running light with all bulbs illuminated
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 23 May 2019 Resolved
Bilge pumps and aft high water alarm are inoperable. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2019
Resolution: Observed 02 fully functional high water alarms and tested all bilge pumps satisfactorily
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2019 Resolved
Port and STBD exhaust pipes have leaks at hose clamp seams. Repair exhaust to prevent leaks.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2019
Resolved 4 June 2019
Resolution: Observed both main engines running at the dock and underway with no exhaust leak. Both main exhausts had new flexible boots installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 May 2019 Resolved
Generator heat exchanger has a leak at the FWD nipple. Repair or replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2019
Resolved 4 June 2019
Resolution: Observed generator while holding the house load with no leaks around the heat exchanger. Generator heat exchanger had been replaced in entirety
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 April 2019 Resolved
Life float water light lanyard is attached to grab line. Lanyard must wrap around body of life float.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2019
Resolved 4 June 2019
Resolution: Observed life float water light lanyard properly spliced around the body of the life float
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 November 2017 Resolved
Forward mast light inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2017
Resolved 22 December 2017
Resolution: Repaired Mast light
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 2 November 2017 Resolved
MMSI number not entered into radio or GPS IAW 47 CFR 80.905.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 22 December 2017
Resolution: Entered MMSI numbers
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 2 November 2017 Resolved
All fuel oil hose in tank room are excessively corroded and need renewal.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2017
Resolved 22 December 2017
Resolution: Replaced hoses
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 2 November 2017 Resolved
Stbd engine outboard exhaust and stbd exhaust pipe in rudder room has minor water leaks.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 29 January 2018
Deck/Cargo › Holds/Tanks › Ventilation Air Intake
Issued 2 November 2017 Resolved
Port and stbd engine room ventilation areas needs sealed better for fire fighting purpose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 22 December 2017
Resolution: Sealed holes in bulkhead
Engineering › Bilge Water Management System › Not Installed
Issued 2 November 2017 Resolved
Manually remove excess water from fwd void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 22 December 2017
Resolution: Removed water
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 2 November 2017 Resolved
Emergency lighting inoperable in berthing areas.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2017
Resolved 29 January 2018
Resolution: Lighting operable in berthing areas.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 2 November 2017 Resolved
Alco test strips are expired IAW 46 CFR 16.401
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 22 December 2017
Resolution: Replaced with new ALCO strips
Communications › Public Address System › Loudspeaker
Issued 2 November 2017 Resolved
Loudhailer inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 29 January 2018
Resolution: Loudhailer operable.
Communications › Radio Communications › VHF Radiotelephone
Issued 2 November 2017 Resolved
Emergency broadcast placard needs to be updated with correct vessel information.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 22 December 2017
Resolution: Corrected placard with current info.
Communications › Radio Communications › EPIRB
Issued 2 November 2017 Resolved
Incorrect safety pin used on EPIRB housing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 22 December 2017
Resolution: Replaced pin.
Communications › Radio Communications › Satellite Communications Capability
Issued 2 November 2017 Resolved
No emergency numbers posted near satelite phone as required on exemption letter.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 22 December 2017
Resolution: Posted emergency numbers.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 19 April 2016 Resolved
Vessel's fire boy did not shut down engines when wire was removed. Vessel could not override the fire boy and restart. Wiring was in question. Have fire boy serviced by a licensed fire service technician and provide a detailed servicing report.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 7 June 2016
Resolution: Fire boy was tested satisfactorily. Vessel was able to override the fire boy and restart and a detailed servicing report was provided.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 19 April 2016 Resolved
Vessel did not have a valid Radiotelephony certificate onboard. Provide valid certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 31 May 2016
Resolution: Vessel had valid cert.
Documentation › Certificates/Documents › FCC SSL
Issued 19 April 2016 Resolved
Vessel did not have valid Vessel Radio Station license and could only provide a printout from FCC website. Provide valid station license.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 31 May 2016
Resolution: Vessel had valid cert.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 19 April 2016 Resolved
Vessel had improper fuel lines leading from fuel filter to generator. Installed lines were not J1942. Replace fuel lines and fittings as per 46 CFR 182.730, or provide paper work that line meets J1942.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 31 May 2016
Resolution: Vessel replaced with approved fuel line.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 19 April 2016 Resolved
Equipment in engine room not properly secured for sea. Properly secure all loose equipment.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 7 June 2016
Resolution: Equipment in engine room was made secure.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 19 April 2016 Resolved
Emergency lighting inoperable. Repair lighting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 31 May 2016
Resolution: Owner replaced emergency lighting.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 April 2016 Resolved
Stowage compartments for PFDs not properly labeled. Properly label life jacket stowage to reflect correct number of life jackets on board.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 31 May 2016
Resolution: Stowage locations properly labeled.
Lifesaving › Rescue Boat › Boarding Ladder
Issued 19 April 2016 Resolved
No proper means to deploy/use MOB ladder on board, as it did not have a place to be attached and it was too short to reach the water. Provide a proper means of operating MOB ladder.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 31 May 2016
Resolution: Moved MOB ladder to convenient place by engine room.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 19 April 2016 Resolved
No updated/appropriate charts for vessels area of operation. Obtain and make available updated charts.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 31 May 2016
Resolution: Vessel had updated charts.
Stability › Watertight Integrity › General
Issued 19 April 2016 Resolved
Lazarette and 2 void spaces forward had bulkhead penetrations that were not watertight make all penetrations to lazarette watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 31 May 2016
Resolution: Owner sealed penetrations.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 19 April 2016 Resolved
Smoke detector in accommodation not of an approved type. Install CG approved detector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 31 May 2016
Resolution: Owner installed approved detectors.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 19 April 2016 Resolved
Drug testing program documentation was outdated. Provide updated information on program.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 31 May 2016
Resolution: Owner provided updated information.
Stability › Watertight Integrity › General
Issued 19 April 2016 Resolved
4 hatches on deck could not be made watertight. Ensure all required hatches are watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 31 May 2016
Resolution: Owner tightened all hatches and made watertight.
Documentation › Certificates/Documents › Exemption Letter (CFIV)
Issued 19 April 2016 Resolved
FCC exemption for satellite phone not available. Make information available.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 31 May 2016
Resolution: Owner provided valid exemption letter.
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 April 2016 Resolved
Underway drills not conducted due to vessel inability to get underway. Conduct drills before completing annual inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 7 June 2016
Resolution: Underway drills were conducted.
Lifesaving › Lifefloat › Painter
Issued 19 April 2016 Resolved
Life float light inoperable, has incorrect type of painter line, and is missing required name plate. Ensure life float meets required criterion.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 7 June 2016
Resolution: Life float light was operable. The proper painter line was installed, and the proper nameplate was added.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 March 2016 Resolved
Vessel's fireboy did not shut down the engines. Vessel could not override the fireboy and restart the engines. Safety pin was still in place with tag reading must be removed after installation or manual release will not work. Wiring was in question. Have system serviced and provide servicing report.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Resolution: Cleared and re-issued.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 8 March 2016 Resolved
Vessel did not have a valid safety Radiotelephony certificate. Provide certificate
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Resolution: Cleared and re-issued.
Documentation › Certificates/Documents › FCC SSL
Issued 8 March 2016 Resolved
Vessel did not have a valid ship station license. Vessel owner could only provide a printout from the FCC website. Provide valid certificate
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Resolution: Cleared and re-issued.
Engineering › Fuel Oil Service System › Piping
Issued 8 March 2016 Resolved
Vessel had improper fuel lines and improper installation from fuel filter to generator. Replace fuel lines and fittings as per CFR.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Resolution: Cleared and re-issued.

Recorded names · 1

BIG ADVENTURE (2020). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.