Records from 1990 to 2012. Most recent: inspection, 10 February 2012.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 25
10 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4241953
4 February 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3412574
6 January 2009
Re-Inspection · Ballast Water Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3389660
18 September 2007
Internal Structural Exam · Annual Inspection · Ballast Water Examination · Examination of Repairs · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3059799
13 February 2007
Examination of Repairs · Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2871269
23 November 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539941
27 October 2005
COI Inspection · Ballast Water Examination · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2523277
23 July 2004
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2142700
17 December 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1721267
19 December 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1474991
7 September 2000
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399434
24 August 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427709
23 June 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409880
19 June 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431809
9 April 1996
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383205
27 September 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 27102
12 April 1995
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358759
24 May 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1169850
30 March 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414279
4 June 1993
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354357
17 March 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1263188
19 February 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 911524
12 December 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 925426
20 March 1990
Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 924093
20 March 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 930892
Construction/Loadline › Hull › Keel
Issued 18 September 2007
Resolved
Provide professional engineer analysis of hull structure to include a section modulas and address hull deformation to the satisfaction aft attending Marine Inspector, to be completed prior to issuance of credit dry
Action required: 705 - Other - as specified
Due 18 October 2007
Resolved 23 January 2008
Resolution: Provided letter form PE/builder, hull sat for continued service, "as is".
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 18 September 2007
Resolved
Provide updated Liftboat operations manual
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 28 January 2008
Resolution: Provided cover letter with current name/owner for ops manual.
Lifesaving › Buoyant Apparatus
Issued 2 January 2002
Resolved
Float free links not connected. LEGACY COMPONENT DESC: weak links
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2002
Resolved 2 January 2002
Resolution: Links connected.
Operations/Management › Drills/Instruction
Issued 2 January 2002
Resolved
No man overboard or fire drills recorded on official log. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2002
Resolved 2 January 2002
Construction/Loadline
Issued 24 August 1999
Resolved
PROVIDE BILGE ALARMS AND INDICATORS FOR PORT/ STBD RUDDER COMPARTMENTS AS PER 46CFR 182.530. TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Lifesaving
Issued 24 August 1999
Resolved
DEMONSTRATE COMPLIANCE WITH D8 POLICY LETTER DATED 12NOV98 "RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS" TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Documentation
Issued 20 March 1990
Resolved
SUBMIT AN OPERATING MANUAL FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C., VESSEL IS PERMITTED TO OPERATE ON ITS EXISTING OPERATING MANUAL UNTIL THE U.S. COAST GUARD APPROVED MANUAL ISRECEIVED.
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990
Documentation
Issued 20 March 1990
Resolved
SUBMIT THE FOLLOWING PLANS FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C.: INBOARD AND OUTBOARD PROFILES, LEG STRUCTURAL SUPPORT AND LEG STRENGTH CRITERIA, HYDRAULIC JACKING SYSTEM DETAILS INCLUDING ALARMS AND CONTROLS.
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990
Documentation
Issued 20 March 1990
Resolved
PROVIDE PLANS AS REQUIRED BY ITEM 1 TO THE COGNIZANT OCMI.
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990
Documentation
Issued 20 March 1990
Resolved
SUBMIT STABILITY CALCULATIONS TO THE U.S. COAST GUARD MARINE SAFETY CENTER FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990
Documentation
Issued 20 March 1990
Resolved
RE-ADMEASURE VESSEL AND PROVIDE DOCUMENTATION THAT VESSEL IS 100 GROSS TONSOR LESS. SEE 46 CFR 69.01-15.
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990
Construction/Loadline
Issued 20 March 1990
Resolved
SUBMIT DOCUMENTATION TO THE U.S. COAST GUARD MARINE SAFETY CENTER WASHINGTON, D.C. THAT PROVE WATERTIGHT DOORS INSTALLED IN LONGITUDINAL AND TRANSVERSE BULKHEADS COMPLY WITH 46 CFR 170.270 (B).
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990
Construction/Loadline
Issued 20 March 1990
Resolved
INSTALL VENTILATION FOR BOTH FUEL OIL COMPARTMENTS. SEE 46 CFR 182.20-50.
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990
Navigation
Issued 20 March 1990
Resolved
CALIBRATE MAGNETIC COMPASS AND SUBMIT DEVIATION TABLE TO [name withheld].
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990