Records from 2016 to 2023. Most recent: inspection, 23 May 2023.
Inspection history · 8
23 May 2023
Drydock Exam · Deficiency Check · COI Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7694974
15 June 2022
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7558765
7 June 2021
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7219023
24 June 2020
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7121371
22 May 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6712152
30 May 2018
DAPI Audit · Deficiency Check · COI Inspection · Drydock Exam
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6429329
8 June 2017
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6173449
16 June 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5933299
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 22 May 2019
Resolved
Stern boarding ladder had a broken step.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Vessel replaced the broken step ladder with a non-broken step.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 22 May 2019
Resolved
Vessel did not have oil discharge prohibited pollution placard posted
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Vessel posted oil discharge prohibited plaque.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 22 May 2019
Resolved
Vessel did not have life jacket donning instructions posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Vessel posted lifejacket donning instructions.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 May 2019
Resolved
Battery did not have protective cover over the terminals i.a.w. 46 CFR 183.200 & 183.354(b).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Vessel added a cover to the battery, eliminating the fire hazard to the terminals.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 22 May 2019
Resolved
Scupper discharge tube was dry rotted away.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Vessel replaced the dry dotted hose with a new hose.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 May 2019
Resolved
The Wiring for the port running light is spliced together with a wire nit. Needs to be properly connected.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Vessel replaced wire nuts with crimped connection.
Engineering › Fuel Oil Service System › Hose
Issued 30 May 2018
Resolved
Flexible fuel supply (hose) line to engine not approved type (SAE J1942 or CG A1)
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 28 June 2018
Resolution: Reneweed with proper hose.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 30 May 2018
Resolved
Lower attached step of rescue/boarding ladder on transom is damaged. Renew same.
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 28 June 2018
Resolution: Step repaired (no renewal part available).
Lifesaving › Lifebuoys › Serviceable
Issued 8 June 2017
Resolved
Ring Lifebouy was missing the reflective material.
Due 30 June 2017
Resolved 30 May 2018
Resolution: Renewed ring buoy