← All vessels
DIVERS DELIGHT
DIVERS DELIGHT is a 1984 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 1984, most recently in June 2026, along with 29 deficiencies and 1 operational control.
Records from 1984 to 2026. Most recent: inspection, 23 June 2026.
- Built
- 1984
- Last inspected
- 23 June 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 29 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
WBZ7612
248666
Flag
UNITED STATES
—
Maury page id
psix-248666
Inspections, by type
…with no type recorded2
Years with a record
37 calendar years (1984–2026)
The 43 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it3 - Regulatory (Subpart C or D), Net Ton
3 - Regulatory (Subpart C or D), Gross Ton
3 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 43
23 June 2026
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8413204
19 November 2024
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8037107
14 September 2023
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7812791
17 June 2022
COI Inspection · Drydock Exam
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7479673
27 August 2021
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7322972
14 September 2020
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7063875
31 July 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6768958
30 July 2018
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6495976
21 June 2017
Drydock Exam · COI Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6155321
13 July 2016
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5980691
22 June 2012
COI Inspection · Hull Examination
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4350807
27 August 2011
Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4128468
27 August 2011
Damage Survey
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4128529
3 June 2008
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3227905
18 June 2007
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2961554
28 June 2006
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2694016
13 June 2005
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2384933
24 June 2004
Re-Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2106672
29 July 2003
Annual Inspection · Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1859228
28 October 2002
Administrative Inspection
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1697417
19 June 2002
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1670116
6 August 2001
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1406992
26 June 2000
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1051560
12 August 1999
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1111951
14 June 1999
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 883459
2 July 1998
Hull Examination · Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 793805
18 July 1997
Deficiency Check · Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 779973
7 June 1996
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1186602
14 June 1995
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 880680
25 May 1994
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 862850
8 December 1993
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 849327
31 August 1993
Administrative
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1141726
30 July 1993
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 844572
8 July 1993
COI Inspection · Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 844244
14 May 1992
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1267356
7 June 1991
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 926347
13 June 1990
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 905730
16 August 1989
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1196177
30 August 1988
Hull Examination · Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1039610
14 July 1987
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1325488
14 August 1986
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1000119
9 September 1985
Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 988175
20 June 1984
Initial Certification
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 988174
Deficiency record · 29
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 November 2024
Resolved
Inspected vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel did not complete annual inspection within 3 months before or after.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 June 2022
Resolved
Flares expired. Provide 12 approved distress signals.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2022
Resolved
PFDs require lights for route in accordance with 46 CFR 180.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 July 2019
Resolved
A vessel on a Great Lakes Route must carry six hand red and six hand orange distress signals i.a.w. 46 CFR 180.68.
Vessel had adequate number but two orange flares expired.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 31 July 2019
Resolved
First aid kit contained expired items: aspirin, ammonia inhalants.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 July 2019
Resolved
Each life jacket carried on a Vessel on a Great Lakes Route must have a lifejacket light. Two lifejackets were not equipped with lights
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 21 June 2017
Resolved
Prove proper operation of GPS receiver
Engineering › Bilge Water Management System › Not Installed
Issued 21 June 2017
Resolved
Bilge pump was removed due to miscommunication from previous inspection. Pump should remain installed and operational.
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 June 2017
Resolved
12V battery installation was in vicinity of fuel (gasoline) lines where remote shut-off valve connections posed potential hazard if spark occured. Reposition batteries to avoid proximity to fuel line.
Lifesaving
Issued 14 June 1999
Resolved
OBTAIN CAT 1 406 MHZ FLOAT FREE EPIRB.
Accommodation/Occupational Safety
Issued 14 June 1999
Resolved
MAKE REPAIRS TO AFT RUB RAIL.
Unknown
Issued 14 June 1999
Resolved
MAKE REPAIRS TO FIRE EXTINGUISHER BRACKET IN FRONT OF HELM.
Engineering
Issued 14 June 1999
Resolved
LABLE OFF DIRECTION ON EMERGENCY FUEL SHUT OFF VALVE IN 1 INCH BLOCK LETTERS.
Fire Fighting
Issued 14 June 1999
Resolved
PROVIDE NOZZLE FOR FIRE HOSE.
Fire Fighting
Issued 18 July 1997
Resolved
SUPPLY A GOOD QUALITY GARDEN HOSE AND BRASS NOZZEL FOR THE HAND FIRE PUMP.
Navigation
Issued 18 July 1997
Resolved
REPLACE MISSING ALL AROUND NAVIGATION LIGHT LENS ON VESSEL'S STERN.
Lifesaving
Issued 18 July 1997
Resolved
SUPPLY A PORTABLE WATERTIGHT CONTAINER FOR DISTRESS FLARES. CONTAINER SHALL BE OF A BRIGHT COLOR AND CLEARLY MARKED IN LEGIBLE CONTRASTING LETTERS AT LEAST 1/2" HIGH: "DISTRESS SIGNALS".
Lifesaving
Issued 18 July 1997
Resolved
SUPPLY US COAST GUARD APPROVED TYPE II RETROREFLECTIVE TAPE TO VESSEL'S RING BUOY. TAPE SHALL BE APPLIED WITH FOUR PIECES ON THE FRONT AND FOUR PIECES ON THE REAR. EACH SQUARE SHALL BE APPROXIMATELY 2" SQUARE.
Lifesaving
Issued 18 July 1997
Resolved
SINCE NO SUITABLE MOUNTING SURFACE IS AVAILABLE INSTRUCTIONS NEED NOT BE POSTED BUT MUST BE CARRIED ABOARD THE VESSEL AND BE AVAILABLE TO THE CREW FOR FAMILIARIZATION.
Engineering
Issued 18 July 1997
Resolved
REPLACE SHORT FLEX FUEL HOSES AT THE EMERGENCY FUEL VALVE WITH USCG TYPE A1, A2 OR B1, B2 FUEL HOSE. ENSURE TWO HOSE CLAMPS ARE SUPPLIED AT EACH HOSE END TO PREVENT LEAKAGE OF GASOLINE.
Lifesaving
Issued 7 June 1996
Resolved
PROVIDE 2 ADDITIONAL ADULT PERSONAL FLOATATION DEVICES (PFD) WITH PFD LIGHTS. TOTAL ADULT PASSENGERS SHALL BE REDUCED TO 17 PASSENGERS. _x001C_
Fire Fighting
Issued 7 June 1996
Resolved
PROVIDE CURRENT SERVICE REPORT ON VESSEL'S PORTABLE FIRE EXTINGUISHERS.
Navigation
Issued 7 June 1996
Resolved
VESSEL TO COMPLY WITH NAV RULE 27(e)(i). "PROVIDE THREE ALL-ROUND LIGHTS IN A VERTICAL LINE WHERE THEY CAN BEST BE SEEN". THE HIGHEST AND LOWEST OFTHESE LIGHTS SHALL BE RED AND THE MIDDLE LIGHT SHALL BE WHITE.
Construction/Loadline
Issued 8 July 1993
Resolved
PROVIDE DOCUMENTATION ATTESTING TO VESSEL WAS BUILT OF FIRE RETARDENT MATERIAL.
Engineering
Issued 8 July 1993
Resolved
INSTALL REMOTE FUEL SHUT OFF VALVES IN WAY OF VESSEL'S 50 GALLON GASOLINE FUEL TANK SUPPLY LINE TO EACH ENGINE.
Fire Fighting
Issued 8 July 1993
Resolved
REPLACE VESSEL'S CURRENT B-I FIRE EXTINGUISHERS WITH TWO U.S.C.G APPROVED TYPE B-II EXTINGUISHES.
Construction/Loadline
Issued 8 July 1993
Resolved
REPAIR OR REPLACE VESSEL'S HAND OPERATED BILGE/FIRE PUMP DUE TO WORN DIAPHRAGM.
Accommodation/Occupational Safety
Issued 8 July 1993
Resolved
COMPLY WITH 46CFR177.30.5 WHERE AS VESSEL IS TO BE PROVIDED WITH A U.S.C.G APPROVED TYPE II OR III MARINE SANITATION DEVICE FOR VOYAGES GREATER THAN 30 MINUTES IN DURATION.
Engineering
Issued 8 July 1993
Resolved
INSTALL TWO HOSE CLAMPS ON THE TOP AND BOTTOM OF THE FUEL TANK FILL AND IN ADDITION INSTALL A STATIC JUMPER, BONDING THE NON-METALLIC SECTIONS.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.