← All vessels
SEA WOLF II
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southwest District (CGD-SW) · Other hulls named SEA WOLF II
SEA WOLF II is a 1985 passenger vessel (inspected). The Coast Guard has recorded 96 inspections since 1985, most recently in February 2026, along with 242 deficiencies, 3 operational controls, 1 with no removal date recorded and 2 casualty investigations between 2007 and 2024.
Records from 1985 to 2026. Most recent: inspection, 24 February 2026.
- Built
- 1985
- Last inspected
- 24 February 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 242 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
- Casualties
- 2 investigations · 2007–2024
Identity
681251
WDL4915
248688
Flag
UNITED STATES
368136090
Maury page id
psix-248688
Inspections, by type
…with no type recorded13
Years with a record
41 calendar years (1985–2026)
The 96 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)59.8 ft × 19.0 ft × 8.4 ft
Registered tonnagegross 82 / net 72
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBONNER YACHTS · WETUMPKA AL, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMONTEREY, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it72 - Regulatory (Subpart C or D), Net Ton
82 - Regulatory (Subpart C or D), Gross Ton
82 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDL4915MMSI 368136090 · active · compulsorily equipped · granted 6 March 2020, expires 6 March 2030
WDF3386MMSI 367439280 · terminated · compulsorily equipped · granted 10 February 2010, cancelled 9 March 2020 · licensed under a name not among this hull’s recorded names (not shown)
WCZ7855MMSI not assigned · expired · compulsorily equipped · granted 28 April 2000, cancelled 3 July 2010
WSL6119MMSI not assigned · expired · compulsorily equipped · granted 1 May 1995, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 96
24 February 2026
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8313518
10 February 2025
Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8077641
20 November 2024
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8037866
17 June 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7933631
22 April 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7902082
30 October 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7816383
5 April 2023
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7663588
12 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608095
6 October 2022
Simplified Stability Test · Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7572859
29 March 2022
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7421133
4 May 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7189363
9 February 2021
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7137108
21 October 2020
Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7080894
12 March 2020
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6925221
6 March 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6637650
15 October 2018
Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6561884
16 February 2018
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6356572
2 March 2017
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6098566
1 November 2016
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6033995
24 June 2016
Examination of Repairs · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5917887
24 August 2015
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5224975
18 March 2014
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4816418
12 June 2012
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4337681
8 July 2011
Type not recorded
No type recorded · Station Monterey · USCG Southwest District (CGD-SW) · Activity 4074529
7 December 2010
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3905448
22 March 2010
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3684771
15 December 2009
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3651451
15 January 2009
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3394981
11 December 2008
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3373718
4 June 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3213720
16 November 2007
Administrative Inspection · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3099919
18 June 2007
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2966373
13 June 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2959913
27 February 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2891607
6 September 2006
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2770476
12 June 2006
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2677911
19 March 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2815619
13 October 2005
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2509881
19 May 2005
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2362317
17 April 2005
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2815539
23 March 2005
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2288246
18 March 2005
Simplified Stability Test
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2313787
22 February 2005
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2296945
18 November 2004
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2229405
8 November 2004
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2236861
14 July 2004
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2132920
30 June 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2113736
11 June 2004
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2095613
1 June 2004
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2084873
26 April 2004
In-Service Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2053811
25 March 2004
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2031070
17 February 2004
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1934065
16 May 2003
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1759713
18 February 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1744242
5 February 2003
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1740092
12 December 2002
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1716868
24 May 2002
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1620581
10 April 2002
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1603225
26 March 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1603373
19 November 2001
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1366668
30 October 2001
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1387188
22 October 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1076029
1 October 2001
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 772982
6 June 2001
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1065957
9 May 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1413929
14 February 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1459680
14 June 2000
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 819255
31 March 2000
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1376098
31 March 2000
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1376099
28 February 2000
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 815673
18 March 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1413518
7 January 1999
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1350905
4 November 1998
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1034495
19 March 1998
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1468842
6 March 1997
COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1454436
25 March 1996
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1409478
16 March 1995
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1409257
10 March 1994
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 856239
1 March 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1167320
28 July 1993
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1154275
21 April 1993
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 840568
10 August 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 952372
30 June 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 124902
15 April 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 958155
8 April 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 954040
13 March 1991
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1237389
12 December 1990
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 906157
21 March 1990
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1225192
3 May 1989
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1035243
12 April 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 888502
22 March 1989
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1199972
30 March 1988
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1033946
27 January 1987
Hull Examination · Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1017842
31 March 1986
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1307805
18 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290117
5 April 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 986041
Deficiency record · 242
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2026
Resolved
On a nonmetallic vessel, the enclosures and frames of electrical equipment must be bonded together to a common ground by a normally non-current carrying conductor. Inverter in bunk space was not grounded.
46 CFR 183.372
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical socket in fwd bunk room had broken faceplate.
46 CFR 183.200(b)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 February 2026
Resolved
All vesseks except non-self-propelled vessels shall be provided with suitable steering apparatus. Cotter pin on steering ram is undersized and causing the welling out of pin space.
46 CFR 182.30-1
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 February 2026
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Missing burn gel.
46 CFR 184.710
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 24 February 2026
Resolved
At each initial and subsequent inspection for certification...the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected Port and STBD sliding windows in Pilot House are cracked.
46 CFR 176.25-50
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 February 2026
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Smoke alarms not interconnected. Master reprogrammed detectors to be interconnected.
46 CFR 181.405(c)
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 17 June 2024
Resolved
At each subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. Discovered fuel leak on inboard side of port fuel tank. Identify source of leak and repair to satisfaction of MI.
46 CFR 176.804
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 June 2024
Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times of the bilge pipe. The bilge suctions in the lazarette and sewage pump compartment did not have strainers.
46 CFR 182.25-5 (OLD T)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2024
Resolved
At each subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. Discovered wet exhaust leaking at penetration on port side forward bulkhead of fuel tank compartment. Repair to satisfaction of the Marine Inspector.
46 CFR 176.804
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2024
Resolved
At each subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. Starboard engine wet exhaust spool piece found to be heavily corroded. Repair to satisfaction of the Marine Inspector.
46 CFR 176.804
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 June 2024
Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame screens shall consist of a single screen of corrosion resistant wire of at least 30x30 mesh. Fuel tank vent was missing flame screen on port side.
46 CFR 182.20-35(OLD T)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 June 2024
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Discovered electrical 12V DC bus bar unsupported beneath pilothouse operating station. Properly mount bus bar to the satisfaction of the Marine Inspector.
46 CFR 183.220(a)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 June 2024
Resolved
All cable and wire must, be installed with metal supports space not more than 24 inches apart, and in such a manner as to avoid damage. Several new electrical installations found under pilothouse operating station improperly supported. Support electric wires and cable.
46 CFR 183.340(b)(4)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 17 June 2024
Resolved
At each subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the inspection of all railings. Courses on upper deck were found broken, and/or not properly secured to the rail posts.
46 CFR 176.802
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 June 2024
Resolved
In general, compliance with the standards established by a recognized class society will be considered satisfactory evidence of the structural adequacy of a vessel. Transverse support beam for the main deck found with broken fiberglass tabbing at the port deck edge in the Engine Room. Repair to the satisfaction of the Marine Inspector.
46 CFR 177.10-1 (OLD T)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 June 2024
Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. Hydraulic hoses for steering ram found to be chafed into the wire reinforced construction. Replace hoses with SAE J-1942 standard.
46 CFR 182.30-1 (OLD T)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 June 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection and operation of all weather tight closures above the weather deck and the provisions for drainage of sea water from the exposed decks. Evidence of moisture and water intrusion found at the port main deck edge supports in the front bunk room. Restore watertight integrity to the satisfaction of the Marine Inspector.
46 CFR 176.802(a)(6)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 June 2024
Resolved
At each subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the inspection of weather decks. Identified the following suspect areas: 1) 24" x 24" soft spot identified on port side upper deck. 2) 12" x 12" soft spot identified on stbd side upper deck. 3) Port and Stbd main deck flexing along the outer exposed passageways at existing repair seams. Repair prior to credit drydock.
46 CFR 176.802
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2024
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Ring life buoy on port bow did not have retroreflective material. Vessel marked ring buoy with retroreflective material in presence of attending MI.
46 CFR 185.604
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 30 October 2023
Resolved
Each marine employer shall ensure that random drug tests conducted under this part are unannounced and that the dates for administering random tests are spread reasonably throughout the calendar year. Company has designated a vessel Master to serve as the Company Designated Employer Representative (DER). This arrangement does not allow for a random selection of crewmembers as intended by this regulation. Company to assign responsibilities of DER to an employee that is not one of the members that shall be randomly drug tested as required by this regulation.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 25 April 2023
Resolved
The movement of vessel shall be under the direction and control of the master or a licensed mate at all times. The master shall operate the vessel keeping the safety of the passengers and crew foremost in mind by directing the vessel in order to prevent a casualty. Vessel has been operating outside the conditions of the stability letter and has allowed passengers on the upper deck. In order to mitigate this requirement, vessel must provide the following addition: Create a chain at the upper and lower ends of the ladder to the second deck. On lower chain, place a sign at midpoint that reads "Maximum of 2 crew allowed on upper deck. No passengers allowed on upper deck while vessel is away from the dock." Chains will have a quick release device to allow crew to transit safely. 46 CFR 185.304(a)
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 6 October 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Repairs or alterations that affect the safety of the vessel include, but are not limited to: structural members. Operator reported a collision with another vessel that resulted in damage to the aft starboard quarter of the upper deck/house top. Submit repair proposal for approval and, once approved,make repairs to the satisfaction of the attending Marine Inspector prior to credit drydock.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 October 2022
Resolved
Unless otherwise specified, vessel owners must pay the fees required by this subpart before inspection or examination services are provided. Vessel is overdue and in collection status for 2021 User Fees. To resolve, contact FINCEN [phone withheld] OR EMAIL [email withheld]. Resolve prior to next inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 March 2022
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation. The vessel currently does not have a valid Certificate of Documentation.
46 CFR 67.313
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 30 March 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices and fire hazards must be corrected. The hose for the drip-less shaft seal was chafed from continuous contact with the shaft. The vessel is to provide a new hose for the drip-less shaft seal and to arrange the hose in such a way that the hose doesn't come in direct contact with the shaft.
46 CFR 176.830(a)
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 30 March 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. The vessel had dead end wires in the engine room that needed to be addressed/removed.
46 CFR 183.200(b)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022
Resolved
A vessel's hull must not carry current as a conductor. The vessel's grounding wires were not properly wired and needs to be addressed.
46 CFR 183.370 (a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 March 2022
Resolved
On a vessel on an exposed or partially protected route, a watertight coaming with a height of at least 6 inches must be provided under each watertight door. The vessel currently has coaming for the weathertight door that is 4 inches high.
46 CFR 179.360(d)(1)
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 March 2022
Resolved
The station transmitting radiotelegraph emissions must be identified by its call sign. The call sign must be transmitted with the telegraphy emission normally used by the station. The call signs on two FCC certifications were mismatched. Vessel operator to obtain a uniform call sign that aligns with both FCC certifications.
47 CFR 80.99 (a)
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 February 2021
Resolved
Each vessel certificated to operate on an oceans route in cold water must be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Vessel currently has IBA with capacity of 50 persons. Vessel is restricted to carrying no more than 48 passengers. For each additional crew member, passenger capacity decreases so that no more than 50 persons are onboard.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 March 2020
Resolved
Materials and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The Port Side AFT deck beam in the Lazarette Compartment is constructed of a wooden laminate. The bottom 1/3 of the wood is delaminated. Provide a repair proposal to the satisfaction of the Marine Inspector.
46 CFR 176.800
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 March 2020
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link. The hydrostatic release for the 02 IBA's were incorrectly installed, and would not have properly operated. The operator corrected the installation on the spot.
46 CFR 180.137(a)(1)
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 March 2020
Resolved
Vapor barriers must be provided where flammable combustible liquids or vapors are present, such as machinery spaces. The aft bulkhead of the engine room had an unsealed penetration. The penetration was sealed to the satisfaction of the attending Marine Inspector.
46 CFR 177.405(e)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 March 2019
Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. Excessive dirt and grime was discovered on the bilge strainer in the Forward Lazarrete space immediately aft of the Engine Room. Clean the strainer to allow proper suction IAW 46CFR182.25-5 to the satisfaction of the MI.
46CFR182.25-5 (OLD T)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 October 2018
Resolved
All engines must be water cooled and meet the requirements of this paragraph. Starboard side MDE sea chest intake ball value is damaged and needs to be replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 16 October 2018
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel. Damaged FRP on the deck support strut in the forward void space, port side. needs to be repaired, increasing structural strength for the forward passenger deck.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 October 2018
Resolved
A vessel must be provided with a main steering gear this is of adequate strength and capable of steering the vessel at all service speeds. Sterning gear transverse support beam weld is cracked, needs to be re-welded.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 16 October 2018
Resolved
Each hatch exposed to the weather must be watertight and have a securing device that is attached to the hatch frame or coaming by hinges, captive chains, or another device to prevent its loss. MSD holding tank space hatch did not have a securing device, needs to have a securing device attached.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 October 2018
Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. Through bulk head penetration, port side of steering gear room does not have vapor tight integrity. Opening must be filling with vapor tight material.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 October 2018
Resolved
A vessel must be provided with a main steering gear that is of adequate strength. Both starboard and port rudders have excessive play, no record of maintenance every being conducted on the rudder system, and unable to visual inspect bearings. These factors have lead me to require the steering gear system to be dissembled and inspected, and repaired accordingly.
Construction/Loadline › Hull › Side Shell
Issued 20 February 2018
Resolved
Cross member and deck supports in the forward void space are cracking and separating. Provide a repair proposal and limit operations to 7 NM offshore. 46 CFR 177.01-5
Electrical › Electrical Distribution System (service) › Cable
Issued 20 February 2018
Resolved
Wiring throughout vessel is improperly installed with frequent loops. Adjust wiring to straighten out and shorten lengths.
Engineering › Steering Gear System › Piping
Issued 20 February 2018
Resolved
In the space forward of the lazarette, hydraulic fittings at the bulkhead for the steering gear are corroded. Replace metallic fitting. 46CFR182.40-1(a)(1)(i)
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 20 February 2018
Resolved
Crew bunk room inaccessible due to excess stored items filling the space. Clean up space for safer access.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 February 2018
Resolved
Electrical wiring in the crew bunk room was found running along the deck with no supports. Install supports for wiring.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 20 February 2018
Resolved
02 Engine Room bulkhead penetrations were found. Refill with appropriate material to ensure bulkhead is vapor tight. 46 CFR 182.35-1(a)
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 February 2018
Resolved
Generator had exposed moving parts posing a hazard to crew. Install guard to cover moving parts. 46 CFR 177.35-15
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 20 February 2018
Resolved
Passenger area found with 02 plastic trash cans. Replace with metallic receptacles. 46 CFR 177.30-7
Construction/Loadline › Structures › Deck Plating
Issued 16 February 2018
Resolved
Excessive mold found on the overheads of the crew bunk room space. Remove mold from overhead. 46 CFR 176.25-45
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 16 February 2018
Resolved
Generator exhaust piping missing hose clamps and tied off using a t-shirt. Install appropriate hose clamps. 46 CFR 182.20-20
Construction/Loadline › Hull › Bracket
Issued 24 June 2016
Resolved
Replace bolts on deck beam in forpeakat both forward and stbd shelf. Reinforce connection by sandwiching with wood of sufficient strength, 46 CFR 177.10(a)
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 18 March 2014
Resolved
Repair or renew leaking MSD tank clean out pipe.
Engineering › Diesel Engine (auxiliary) › Distributor (fuel injection)
Issued 12 June 2012
Resolved
Properly repair fuel oil leak and provide proper operation of the generator.
Fire Fighting › Fire Hydrants › Material
Issued 12 June 2012
Resolved
Replace the existing garden hose with commercial grade fire hose and nozzle
Construction/Loadline › Hull › Hull Plating
Issued 7 December 2010
Resolved
Provide proper repairs to hull on starboard side area of delamination.
Construction/Loadline › Hull › Transverse Frame
Issued 7 December 2010
Resolved
Properly repair patches on forward transverse bulkhead starboard side.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 March 2010
Resolved
Provide STBD side light lens cover that meets standards in international/inland rules.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 March 2010
Resolved
Provide suitable arrangement to recover man overboard from water.
Fire Fighting › Nozzles › Type
Issued 22 March 2010
Resolved
Provide fire hose nozzles that are corrosion resistant in accordance with 46 CFR 181.320 (d).
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 March 2010
Resolved
Provide suitable marine grade wiring on generator feed line to breaker panel.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 22 March 2010
Resolved
Provide covers for spare connection ports on junction box in engine room.
Engineering › Bilge Water Management System › Hose
Issued 22 March 2010
Resolved
Provide suitable discharge hose for hand bilge pump.
Documentation › Markings/Placards › Warning Signs
Issued 22 March 2010
Resolved
Provide sign indicating crew only or no passengers allowed for upper deck.
Documentation › Markings/Placards › Official Number (US)
Issued 22 March 2010
Resolved
Provide proof of permanently marked official number IAW 46 CFR 67.121
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009
Resolved
Company did not have result/exemptions for pre-employment testing prior for individuals working in a safety sensitive position, as required by 46 CFR 16.210.
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009
Resolved
Arrangements not made for post-casualty testing as required by 46 CFR 16.240.
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009
Resolved
Alcohol testing devices not onboard as required by 46 CFR 4.
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009
Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company's drug and alcohol policy in accordance with 46 CFR 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009
Resolved
Supervisors has no proof of 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 December 2008
Resolved
Repair port exhaust in engine room.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 December 2008
Resolved
Repair port exhaust in second void from aft.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 4 June 2008
Resolved
Repair leak from STBD side inboard diesel fuel filter.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 4 June 2008
Resolved
Prove proper operation of fixed fire extinguishing system (over ride). 46 CFR 181.420.b.
Stability › Weathertight Integrity › General
Issued 18 June 2007
Resolved
Complete permanent repairs to bow delamination prior to 30Nov07 in accordance with written repair proposal of 12Jul07.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 June 2007
Resolved
Properly dead end wiring for chart plotter on the bridge.
Communications › Radio Communications › EPIRB
Issued 13 June 2007
Resolved
Make permanent repairs to EPIRB antenna. Vessel is restricted to less than 3 NM from shore until proof is provided.
Lifesaving › Lifefloat › Serviceable
Issued 13 June 2007
Resolved
Repair one 15 person lifefloat with approved repair kit.
Lifesaving › Lifebuoys › Serviceable
Issued 13 June 2007
Resolved
Repair ring buoy with approved repair kit.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 13 June 2007
Resolved
Provide approved bracket for B-II extinguisher in below deck accommodation space.
Engineering › Bilge Water Management System › Not Operational
Issued 13 June 2007
Resolved
Repair inoperable light on bilge alarm panel for compartment 3.
Stability › Weathertight Integrity › General
Issued 13 June 2007
Resolved
Provide means to secure bridge window amidships.
Stability › Weathertight Integrity › General
Issued 13 June 2007
Resolved
Submit plans to repair delaminated deck area on bow.
Engineering › Bilge Water Management System › Hose
Issued 13 June 2007
Resolved
Double clamp flexible hose on engine room bilge piping.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 13 June 2007
Resolved
Provide means of locking sewage overboard discharge valve when within 3 NM from shore.
Engineering › Steering Gear System › Fastener
Issued 13 June 2007
Resolved
Properly secure all bolts on steering arm in lazarette.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 June 2007
Resolved
Properly dead end wiring in junction box in galley.
Electrical › Electric Generation Source (service) › Generator
Issued 13 June 2007
Resolved
Prove proper operation of generator and repair leak on gasket for generator fuel filter.
Operations/Management › Drills/Instruction › Fire
Issued 13 June 2007
Resolved
Perform satisfactory fire and man overboard drills prior to carrying passengers.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 13 June 2007
Resolved
Properly label all adult PFD stowage areas.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 June 2007
Resolved
Replace expired aspirin in vessel first aid kit.
Engineering › Diesel Engine (propulsion-electric) › Pump, High Pressure (fuel injection)
Issued 13 June 2007
Resolved
Prove proper operation of starboard main diesel engine prior to carrying passengers.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 June 2006
Resolved
Post valid Certificate of inspection IAW 46 CFR 176.107
Documentation › Certificates/Documents › Stability Letter
Issued 14 June 2006
Resolved
Post stability letter at operating station IAW 46 CFR 176.306.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 14 June 2006
Resolved
Provide up to date light list and coast pilot for vessel's routes IAW 46 CFR 183.420.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 14 June 2006
Resolved
Provide current edition of Rules of the Road - edition (D) IAW 33 CFR 88.05.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 14 June 2006
Resolved
Post Life jacket donning placards IAW 46 CRF 185.516.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 June 2006
Resolved
Fasten the high water alarm sensor and bilge pump in fwd void space.
Electrical › Electric Supply System (service) › Cable
Issued 14 June 2006
Resolved
Properly fasten loose wires in the following spaces; lazarette (fwd bulkhead), engine room (aft bulkhead), Forepeak (high water alarm and aft bulkhead) IAW 46 CFR 183.340.
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 June 2006
Resolved
Provide repair proposal for cracked gussets in forepeak prior to start.
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 June 2006
Resolved
Repair all gussets in forepeak upon approved plans from attending Marine Inspector,
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 June 2006
Resolved
Make permanent repairs to center main beam that has dropped on stern end of lazarette.
Stability › Watertight Integrity › General
Issued 14 June 2006
Resolved
Prove watertight integrity in all three compartments on fantail in way of scuttles and port side deck. All bilges shall be pumped dry and overhead and bulkheads shall be dry prior to test IAW 46 CFR 175-400 (Watertight).
Stability › Watertight Integrity › General
Issued 14 June 2006
Resolved
Prove watertight integrity in forepeak. All bilges shall be pumped dry and overhead and bulkheads shall be dry prior to test IAW 46 CFR 175-400 (Watertight). Attending Marine Inspector shall key on portside rub rail and below.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 June 2006
Resolved
Make port and stern light operational IAW 46 CFR 183.420.
Lifesaving › Lifefloat › Float Free
Issued 14 June 2006
Resolved
Make all life floats float free IAW 46 CFR 180.130.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 14 June 2006
Resolved
Make 6 adult and 2 child type 1 PFD lights operational.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 14 June 2006
Resolved
Properly label 2 adult type 1 PFD's with vessels name.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 23 March 2005
Resolved
Secured the top step of the ladder to the pilot house.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 23 March 2005
Resolved
Provide proof current tides and currents tables.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 23 March 2005
Resolved
Properly label child and adult PFD storage.
Stability › Weathertight Integrity › General
Issued 23 March 2005
Resolved
Provide proof that the pilot house is weathertight.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 23 March 2005
Resolved
Renew the lifeline for both the port and starboard buoy apparatus.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 March 2005
Resolved
Renew the grab line for the life ring.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 March 2005
Resolved
Renew the waterlight lanyard for the life ring.
Stability › Weathertight Integrity › General
Issued 23 March 2005
Resolved
Renew the starboard crack bridge window.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 23 March 2005
Resolved
Properly secure the ladder for the engine room and forepeak compartment.
Stability › Watertight Integrity › General
Issued 23 March 2005
Resolved
Provide proof that the forepeak and #6 compartment is watertight.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 March 2005
Resolved
Tighten the port and starboard railing.
Construction/Loadline › Hull › Hull Plating
Issued 23 March 2005
Resolved
Repair the crack on the port beam IAW NVIC 8-87. Submit repair proposal to the attending marine inspector.
Construction/Loadline › Structures › Superstructure
Issued 23 March 2005
Resolved
Remove deck material circle in yellow around the pilot house and make it available for inspection.
Construction/Loadline › Structures › Superstructure
Issued 23 March 2005
Resolved
Repair cracks around pilot house IAW NVIC 8-87 & submit repair proposal. Allowed the vessel to operate on the under the following the conditions:
1. No passengers are allowed on the upper deck.
2. Both port and starboard deck space around the pilothouse is blocked out.
Lifesaving › Hand Flares › Quantity
Issued 23 March 2005
Resolved
Renew 1 red flare.
Documentation › Logs/Records › Drug Test Records
Issued 23 March 2005
Resolved
Provide proof of crew enrollment in a random drug testing program.
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 23 March 2005
Resolved
Provide proof of 50% of the crew is First Aid/CPR qualified.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 March 2005
Resolved
Renew the stern and starboard Navigation Lights.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 23 March 2005
Resolved
Renew all PFDs marking with the vessel's name.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 23 March 2005
Resolved
Remove the bucket in the engine room that is filled with oily water.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 23 March 2005
Resolved
Hose clamp the generator exhaust piping.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 23 March 2005
Resolved
Renew the port exhaust piping. Temporary patch is allowed. This requirement must be completed by 30 March 05.
Stability › Intact Stability (when using lifting gear) › General
Issued 22 February 2005
Resolved
Conduct a simplified stability proof test IAW 46CFR 178.330.
Construction/Loadline › Penetrations › Valve Flange
Issued 10 December 2004
Resolved
Properly repair or replace gate valve on port bilge overboard in fuel tank void. Provide a means to operatie the valve as well. This item shall be completed prior to 10FEB05.
Stability › Watertight Integrity › General
Issued 10 December 2004
Resolved
Prove proper operation and watertight integrity of deck hatches (three) on fantail.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 10 December 2004
Resolved
Complete starboard fuel tank installation by topping off tank and making it available to inspection by a CG marine inspector.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 29 November 2004
Resolved
Install cover or properly dead end receptable in front of bench on FWD portion of main deck cabin IAW 46CFR 183.210
Stability › Watertight Integrity › General
Issued 29 November 2004
Resolved
Properly cap unused overboard discharge on STBD bulkhead - FWD in engine room. Currently there is an inoperable gate valve mounted there without any plumbing connected.
Stability › Watertight Integrity › General
Issued 29 November 2004
Resolved
Properly secure and make watertight capped overboard discharge (thru hull fitting) on STBD - aft bulkhead in engine room.
Construction/Loadline › Penetrations › Valve Flange
Issued 29 November 2004
Resolved
Replace wasted port MDE raw water suction valve IAW 46CFR179.350
Construction/Loadline › Penetrations › Valve Flange
Issued 29 November 2004
Resolved
Install double hose clamps on ships generator overboard exhaust IAW 46CFR 182.430
Construction/Loadline › Penetrations › Valve Flange
Issued 29 November 2004
Resolved
Replace two inoperable gate valves for bilge overboard discharge in aft void space FWD of lazarette and in lazarette.
Stability › Watertight Integrity › General
Issued 29 November 2004
Resolved
Prove watertight intergrity of forepeak deck IAW 46CFR 171.50
Stability › Watertight Integrity › General
Issued 29 November 2004
Resolved
Indentify cause of water seepage thru hull. Must be completed prior to receiving credit for drydock.
Engineering › Steering Gear System › Linkage
Issued 29 November 2004
Resolved
Install pin of appropriate size and bushing for linkage that secures the steering gear to the hydraulic ram.
Stability › Watertight Integrity › General
Issued 24 November 2004
Resolved
Properly seal all watertight bulkhead penetrations in engine room including fuel lines on stbd side and top bolt hole on stbd exhaust IAW 46CFR 179.212
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 24 November 2004
Resolved
Install drip guard over breaker mounted on aft engineroom bulkhead.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 November 2004
Resolved
Replace light cover on light fixture over port engine IAW 46CFR 183.410
Accommodation/Occupational Safety › Ventilation › General
Issued 24 November 2004
Resolved
Reattach ventilation fitting on outboard top of sewage tank on portside
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 November 2004
Resolved
Remove and arrest furring on main transverse beams in engine room
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 24 November 2004
Resolved
Properly attach deck stringers in lazarette and fuel compartment as indicated by attending Marine Inspector.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 November 2004
Resolved
Properly reattach transverse beams to deck and hull on stbd side of FWD berthing space.
Construction/Loadline › Structures › Superstructure
Issued 24 November 2004
Resolved
All fiberglass repairs shall be made to the satisfaction of the attending Marine Inspector and IAW Navigation and Vessel Inspection Circulars (NVIC) 8-87.
Construction/Loadline › Hull › Side Shell
Issued 19 November 2004
Resolved
All fiberglass repairs; particularly items #6, #11, #13, and #16 issued at the drydock hull inspection on 18NOV04; shall be made to the satisfaction of the attending marine inspector and in accordance with navigation and vessel inspection circular (NVIC) 8-87.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 November 2004
Resolved
Properly secure deck rails on port and starboard deck IAW 46CFR177.900. Must be completed prior to receiving credit for drydock.
Construction/Loadline › Penetrations › Pipe Flange
Issued 18 November 2004
Resolved
Properly seal all watertight bulkhead penetrations in way of collision bulkhead, engine room, void space under fantail, and lazarette IAW 46CFR179.212. Must be completed prior to receiving credit for drydock.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 November 2004
Resolved
Install cover on junction box in fuel tank void IAW 46CFR179.212. Must be completed prior to receiving credit for drydock.
Engineering › Bilge Water Management System › Pump
Issued 18 November 2004
Resolved
Properly secure and mount bilge pump, float switch, and piping in way of forepeak, forward berthing area, and lazarette IAW 46CFR181.300.
Construction/Loadline › Hull › Side Shell
Issued 18 November 2004
Resolved
Submit repair proposal for damage on port bow in way of rub rail IAW 46CFR176.700. Must be completed prior to receiving credit for drydock.
Construction/Loadline › Hull › Side Shell
Issued 18 November 2004
Resolved
Make area above ceiling on starboard side forward berthing area available for inspection IAW 46CFR176.610. Must be completed prior to receiving credit for drydock.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 November 2004
Resolved
Use metal supports to mount wiring that is currently over the engine IAW 46 CFR 183.340. Must be completed prior to receiving credit for drydock.
Engineering › Steering Gear System › Rudder Stock
Issued 18 November 2004
Resolved
Repair porous (washed out) welds on starboard rudder post. Must be completed prior to receiving credit for drydock.
Construction/Loadline › Hull › Transverse Frame
Issued 18 November 2004
Resolved
Repair delamination on transverse deck beams in overhead of forepeak in way of port and starboard side shell.
Engineering › Steering Gear System › Fastener
Issued 18 November 2004
Resolved
Properly secure all through bolts for mounting bracket on port side rudder post.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 18 November 2004
Resolved
Renew wasted set screw on starboard side stern tube.
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 November 2004
Resolved
Replace/repair all wasted or missing deck longitudinals in lazarette.
Engineering › Bilge Water Management System › Valve
Issued 18 November 2004
Resolved
Prove proper operation of overboard discharge gate valve in way of port side aft top bunk in aftmost berthing area IAW 46CFR176.802. Must be completed prior to receiving credit for drydock.
Fire Fighting › Fire Pumps › Power Source
Issued 18 November 2004
Resolved
Prove proper operation of fire pump on port side engine IAW 46CFR 181.300
Stability › Watertight Integrity › General
Issued 18 November 2004
Resolved
Repair or properly remove and cap overboard discharge in FWD berthing area. Must be completed prior to receiving credit for drydock.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 18 November 2004
Resolved
Install splash guard over wiring panel in engine room overhead amidships IAW 46CFR 183.330. Must be completed prior to receiving credit for drydock.
Stability › Watertight Integrity › General
Issued 18 November 2004
Resolved
Repair identified areas of delamination of fiberglass on hull IAW 46CFR 176.700. Must be completed prior to receiving credit for drydock.
Navigation › Piloting/Steering › Marine Charts
Issued 30 June 2004
Resolved
Provide chart with updated corrections.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 June 2004
Resolved
Renew eyewash for 1st aid kit.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 30 June 2004
Resolved
Provide tide & current tables.
Navigation › Piloting/Steering › US Coast Pilot
Issued 30 June 2004
Resolved
Provide updated Coast Pilot & Light List.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 June 2004
Resolved
Provide supports for electrical wiring in way of fule tank compartment.
Stability › Watertight Integrity › General
Issued 30 June 2004
Resolved
Make collision bulkhead watertight.
Construction/Loadline › Structures › End Bulkhead
Issued 30 June 2004
Resolved
Delamination in fore peak void in way of deck support beam and collision bulkead at the deck to hull intersection. Submit repair proposal, for approval, to repair delamination.
Engineering › Bilge Water Management System › Not Operational
Issued 30 June 2004
Resolved
Prove operation of the audible alarms for the engine room bilge pumps.
Electrical › Electric Generation Source (service)
Issued 26 April 2004
Resolved
AC power source selector switch box missing strain relief locknut. LEGACY COMPONENT DESC: Switch
Electrical › Electric Generation Source (service)
Issued 26 April 2004
Resolved
Install approved metallic support fasteners in way of grounding conductor from AC power source selector swtich box to hull in Engine Room. LEGACY COMPONENT DESC: Grounding Conductor
Electrical › Electrical Distribution System (service)
Issued 26 April 2004
Resolved
Behind AC Electrical Panel in pilothouse, fold back, tape and label electrical cable as a "Dead Ended Cable". LEGACY COMPONENT DESC: Panelboard
Electrical › Electric Generation Source (service)
Issued 26 April 2004
Resolved
Vessel restricted from operating generator while passengers are on board due to lack of emergency shutdown while fixed fire fighting system is activated. LEGACY COMPONENT DESC: Generator
Electrical › Electric Generation Source (service)
Issued 26 April 2004
Resolved
Provide plans for approval of generator electrical shutdown circuit in way of the fixed fire fighting system. LEGACY COMPONENT DESC: Generator
Lifesaving › Buoyant Apparatus
Issued 16 May 2003
Resolved
Repair as new damaged 15-person life float.
Navigation › Piloting/Steering
Issued 16 May 2003
Resolved
Provide current Light List, Coast Pilot, proof may be faxed. LEGACY COMPONENT DESC: Coast Guard Light List
Engineering › Bilge Water Management System
Issued 16 May 2003
Resolved
Remove excess oil in bilge, iaw 46CFR176.830.
Engineering › Generator (propulsion-electric)
Issued 12 December 2002
Resolved
Provide plans and specification information for new installation of generator. Plans shall include electrical, mechanical and exhaust installation. The generator shall not be used until all plans and specifications are approved by an attending Marine Inspector.
Accommodation/Occupational Safety › Medical/First Aid
Issued 24 May 2002
Resolved
Replace all expired items in First Aid kit with new items. LEGACY COMPONENT DESC: Medicine Chest
Pollution Prevention/Response › Prevention Equipment
Issued 24 May 2002
Resolved
Prove proper operation of bilge audible alarms. LEGACY COMPONENT DESC: Bilge Monitor
Electrical
Issued 24 May 2002
Resolved
Properly clean and protect all battery posts in engineroom.
Documentation › Markings/Placards
Issued 24 May 2002
Resolved
Post two 12 person adult life jacket placards and update child life jacket placard to reflect eight child life jackes vice six. LEGACY COMPONENT DESC: Capacity Marking
Navigation › Piloting/Steering
Issued 24 May 2002
Resolved
Prove proper operation of compass light. LEGACY COMPONENT DESC: Steering Magnetic Compass
Engineering › Diesel Engine (propulsion-direct drive)
Issued 24 May 2002
Resolved
Make both Main Diesel Engines exhaust tubes water tight in way of lazarette. LEGACY COMPONENT DESC: Piping (exhaust)
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 24 May 2002
Resolved
Add one child life jacket.
Lifesaving › Buoyant Apparatus
Issued 24 May 2002
Resolved
Properly secure two weak links to Life floats, mark floats with vessels name and add spacers between life floats.
Lifesaving › Lifebuoys
Issued 24 May 2002
Resolved
Properly mark lifebuoy with vessels name.
Communications › Radio Communications › EPIRB
Issued 24 May 2002
Resolved
Properly log monthly EPIRB tests.
Personnel › Training
Issued 24 May 2002
Resolved
Abtain certification for First Aid/CPR. LEGACY COMPONENT DESC: First Aid/CPR
Engineering
Issued 19 November 2001
Resolved
Renew all fuel hoses on the generator using approved hose. Hose must meet or exceed 46 CFR 182.720 or SAE J1942.
Construction/Loadline
Issued 19 November 2001
Resolved
Make all PVC or plastic bulkhead penetrations watertight as required by 46 CFR 182.720(d)(1)
Electrical
Issued 19 November 2001
Resolved
Install battery on generator in accordance with 46 CFR 183.350.
Engineering
Issued 30 October 2001
Resolved
Machine guards shall be placed on stbd side engine fire pump installation iaw 46 CFR 177.960.
Construction/Loadline
Issued 30 October 2001
Resolved
Prove watertight intergrity of all flush hatches located on the main deck.
Construction/Loadline
Issued 30 October 2001
Resolved
Properly repair delaminated areas in the chain locker, port & stbd side outboard near aft bulkhead, iaw NVIC 8-87.
Electrical
Issued 30 October 2001
Resolved
until plans are approved, newly installed generator shall not be used.
Fire Fighting
Issued 9 May 2001
Resolved
HAVE ALL PORTABLE FIRE EXTINGUISHERS SERVICED IAW 46 CFR 176.810. _x001C_ COMPLETE PRIOR TO CARRIAGE OF PASSENGERS. FAX OF SERVICING CERTIFICATE TO THIS OFFICE WILL SUFFICE.
Navigation
Issued 9 May 2001
Resolved
PROVIDE LIGHT FOR MAGNETIC COMPASS. COMPLETE PRIOR TO CARRYING PASSENGERS IN NON-DAYLIGHT HOURS.
Unknown
Issued 9 May 2001
Resolved
PROVE PROPER OPERATION OF SINGLE-SIDE BAND RADIO. _x001C_ COMPLETE PRIOR TO TAKING PASSENGERS MORE THAN 20 NM FROM SHORE.
Navigation
Issued 9 May 2001
Resolved
REPAIR STARBOARD RUDDER POST.
Lifesaving
Issued 9 May 2001
Resolved
PROVIDE SPACERS FOR LIFEFLOATS.
Lifesaving
Issued 9 May 2001
Resolved
PERMANENTLY ATTACH LIFEFLOAT PAINTERS TO WEAK LINKS.
Accommodation/Occupational Safety
Issued 9 May 2001
Resolved
REPAIR DECK RAIL PORTSIDE, AMIDSHIPS.
Lifesaving
Issued 9 May 2001
Resolved
ATTACH WATERLIGHT TO PORT LIFEFLOAT.
Construction/Loadline
Issued 9 May 2001
Resolved
ADD A GASKET TO HATCH COVER FOR AFT LAZARETTE.
Lifesaving
Issued 9 May 2001
Resolved
PROVIDE HOSE FOR PORTABLE BILGE PUMP.
Fire Fighting
Issued 9 May 2001
Resolved
HAVE FIXED FIREFIGHTING IN ENGINEROOM SERVICED IAW 46 CFR 176.810. _x001C_ COMPLETE PRIOR TO CARRIAGE OF PASSENGERS. FAX OF SERVICING CERTIFICATE TO THIS OFFICE WILL SUFFICE.COMPLETE PRIOR TO CARRIAGE OF PASSENGERS. FAX OF SERVICING CERTIFICATE TO THIS OFFICE WILL SUFFICE.
Lifesaving
Issued 31 March 2000
Resolved
CONDUCT FIRE AND MAN OVERBOARD DRILLS.
Fire Fighting
Issued 6 March 1997
Resolved
FREE UP OR REPLACE THE AFTER MAIN PASSENGER ACCOMMODATION FIRE EXTINGUISHERBRACKET, SUPPORT ARM INOPERATIVE.
Construction/Loadline
Issued 6 March 1997
Resolved
REGLASS FORWARD KINGPOST FOUNDATION TO HULL SUPPORT STRUCTURE. CURRENT FIBERGLASS HAS BEEN BROKEN LOOSE FROM HULL.
Engineering
Issued 6 March 1997
Resolved
PROPOSE AND COMPLETE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR,REPAIRS TO PORT PROPULSION ENGINE EXHAUST PIPING LOCATED IN THE VOID SPACE AFT OF THE FUEL TANK COMPARTMENT.
Engineering
Issued 16 March 1995
Resolved
RENEW STBD FUEL FILL HOSE AND INSTALL BONDING WIRE ON BOTH FILL HOSES._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 16 March 1995
Resolved
REMOVE PETCOCK FROM GENERATOR FUEL STRAINER.
Navigation
Issued 16 March 1995
Resolved
INSTALL THIMBLE ON ANCHOR LINE AND MOUSE SHACKLE.
Accommodation/Occupational Safety
Issued 16 March 1995
Resolved
RENEW OIL POLLUTION PLACARD.
Accommodation/Occupational Safety
Issued 16 March 1995
Resolved
REPAIR FIBERGLASS DELAMINATION IN FOREPEAK.
Accommodation/Occupational Safety
Issued 16 March 1995
Resolved
RENEW PILOT HOUSE WINDOW ON STBD SIDE WHERE FRACTURED
Lifesaving
Issued 16 March 1995
Resolved
RENEW ONE LIFEFLOAT PADDLES
Navigation
Issued 16 March 1995
Resolved
PROVE OPERATION OF VESSEL'S SINGLE SIDE BAND RADIO. VESSEL IS RESTRICTED TO NOT MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL CORRECTED.
Engineering
Issued 16 March 1995
Resolved
INSTALL FUEL SHUT OFF VALVES ON BOTH MAIN ENGINES.
Navigation
Issued 10 March 1994
Resolved
PROVE PROPER OPERATION OF VESSELS SSB-AM RADIO.
Navigation
Issued 8 April 1992
Resolved
PROVE OPERATION OF RADAR OR REMOVE FROM VESSEL.
Navigation
Issued 8 April 1992
Resolved
SSB RADIO REMOVED FROM VESSEL BY OPERATOR DUE TO CABIN TOP LEAK. BUILDER TOFABRICATE NEW CABIN TOP AND SUBMIT PLANS TO MOBMS FOR REVIEW.
Unknown
Issued 13 March 1991
Resolved
INSTALL A WARNING DEVICE VISIBLE OR AUDIBLE AT THE ENGINE OPERATION STATIONTO INDICATE ANY FAILURE OF WATER FLOW IN THE EXHAUST COOLING SYSTEM OF BOTHMAIN ENGINES.
Unknown
Issued 30 March 1988
Resolved
PROVIDE DOUBLE HOSE CLAMPS FOR ALL FLEXIBLE PIPE CONNECTIONS.
Unknown
Issued 30 March 1988
Resolved
CLEAN VESSEL AND MAKE READY FOR PASSENGERS.
Unknown
Issued 30 March 1988
Resolved
REMOVE ALL EXCESS WIRING FROM VESSEL
Unknown
Issued 30 March 1988
Resolved
MAKE ALL WIRE CONNECTIONS IN JUNCTION BOXES OR WITH APPROVED PRESSURE CONNECTIONS.
Unknown
Issued 30 March 1988
Resolved
PROVIDE WT. BOX FOR FLAMES.
Unknown
Issued 30 March 1988
Resolved
CHANGE CPFD MARKING FROM 6 TO 7.
Unknown
Issued 30 March 1988
Resolved
PROVE PROPER OPS. OF BOW LIGHT AND COVER.
Unknown
Issued 30 March 1988
Resolved
EFFECT WELDED REPAIRS TO LEAKS IN BOTH MDE EXHAUST LINES IN LAZARETTE.
Unknown
Issued 30 March 1988
Resolved
PROPERLY BRACKET HYDRAULIC PIPING IN LAZARETTE.
Unknown
Issued 30 March 1988
Resolved
PERM SECURE 2 BATTERY BOXES IN ENGINEROOM.
Lifesaving
Issued 27 January 1987
Resolved
PROVIDE SECURING BRACKET AFT OF BUOYANT APPARATUS.
Casualty record · 2
27 February 2007Routine · role: Involved in a Marine Casualty · activity 2891607
22 April 2024Routine · role: Involved in a Marine Casualty · activity 7902082
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.