MAURY USCG vessel records Sign in
← All vessels

SEA WOLF II

SEA WOLF II is a 1985 passenger vessel (inspected). The Coast Guard has recorded 96 inspections since 1985, most recently in February 2026, along with 242 deficiencies, 3 operational controls, 1 with no removal date recorded and 2 casualty investigations between 2007 and 2024.

Records from 1985 to 2026. Most recent: inspection, 24 February 2026.

Built
1985
Last inspected
24 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WDL4915
248688
Flag
UNITED STATES
368136090
Maury page id
psix-248688

Inspections, by type

…with no type recorded13
Years with a record 41 calendar years (1985–2026)
The 96 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)59.8 ft × 19.0 ft × 8.4 ft
Registered tonnagegross 82 / net 72
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBONNER YACHTS · WETUMPKA AL, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMONTEREY, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it72 - Regulatory (Subpart C or D), Net Ton
82 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL4915MMSI 368136090 · active · compulsorily equipped · granted 6 March 2020, expires 6 March 2030
WDF3386MMSI 367439280 · terminated · compulsorily equipped · granted 10 February 2010, cancelled 9 March 2020 · licensed under a name not among this hull’s recorded names (not shown)
WCZ7855MMSI not assigned · expired · compulsorily equipped · granted 28 April 2000, cancelled 3 July 2010
WSL6119MMSI not assigned · expired · compulsorily equipped · granted 1 May 1995, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 96

24 February 2026 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8313518
10 February 2025 Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8077641
20 November 2024 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8037866
17 June 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7933631
22 April 2024 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7902082
30 October 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7816383
5 April 2023 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7663588
12 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608095
6 October 2022 Simplified Stability Test · Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7572859
29 March 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7421133
4 May 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7189363
9 February 2021 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7137108
21 October 2020 Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7080894
12 March 2020 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6925221
6 March 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6637650
15 October 2018 Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6561884
16 February 2018 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6356572
2 March 2017 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6098566
1 November 2016 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6033995
24 June 2016 Examination of Repairs · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5917887
24 August 2015 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5224975
18 March 2014 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4816418
12 June 2012 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4337681
8 July 2011 Type not recorded
No type recorded · Station Monterey · USCG Southwest District (CGD-SW) · Activity 4074529
7 December 2010 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3905448
22 March 2010 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3684771
15 December 2009 DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3651451
15 January 2009 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3394981
11 December 2008 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3373718
4 June 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3213720
16 November 2007 Administrative Inspection · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3099919
18 June 2007 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2966373
13 June 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2959913
27 February 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2891607
6 September 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2770476
12 June 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2677911
19 March 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2815619
13 October 2005 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2509881
19 May 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2362317
17 April 2005 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2815539
23 March 2005 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2288246
18 March 2005 Simplified Stability Test
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2313787
22 February 2005 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2296945
18 November 2004 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2229405
8 November 2004 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2236861
14 July 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2132920
30 June 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2113736
11 June 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2095613
1 June 2004 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2084873
26 April 2004 In-Service Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2053811
25 March 2004 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2031070
17 February 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1934065
16 May 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1759713
18 February 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1744242
5 February 2003 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1740092
12 December 2002 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1716868
24 May 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1620581
10 April 2002 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1603225
26 March 2002 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1603373
19 November 2001 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1366668
30 October 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1387188
22 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1076029
1 October 2001 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 772982
6 June 2001 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1065957
9 May 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1413929
14 February 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1459680
14 June 2000 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 819255
31 March 2000 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1376098
31 March 2000 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1376099
28 February 2000 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 815673
18 March 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1413518
7 January 1999 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1350905
4 November 1998 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1034495
19 March 1998 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1468842
6 March 1997 COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1454436
25 March 1996 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1409478
16 March 1995 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1409257
10 March 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 856239
1 March 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1167320
28 July 1993 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1154275
21 April 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 840568
10 August 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 952372
30 June 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 124902
15 April 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 958155
8 April 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 954040
13 March 1991 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1237389
12 December 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 906157
21 March 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1225192
3 May 1989 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1035243
12 April 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 888502
22 March 1989 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1199972
30 March 1988 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1033946
27 January 1987 Hull Examination · Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1017842
31 March 1986 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1307805
18 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290117
5 April 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 986041

Deficiency record · 242

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2026 Resolved
On a nonmetallic vessel, the enclosures and frames of electrical equipment must be bonded together to a common ground by a normally non-current carrying conductor. Inverter in bunk space was not grounded. 46 CFR 183.372
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2026
Resolved 2 March 2026
Resolution: Operator provided video of inverter grounded to the metal base of a motor in the engine room.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical socket in fwd bunk room had broken faceplate. 46 CFR 183.200(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2026
Resolved 2 March 2026
Resolution: Operator provided photo of replaced faceplate.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 February 2026 Resolved
All vesseks except non-self-propelled vessels shall be provided with suitable steering apparatus. Cotter pin on steering ram is undersized and causing the welling out of pin space. 46 CFR 182.30-1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2026
Resolved 2 March 2026
Resolution: Operator sent photo of new properly sized pin installed on ram.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 February 2026 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Missing burn gel. 46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2026
Resolved 2 March 2026
Resolution: Operator provided photo of burn gel
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 24 February 2026 Resolved
At each initial and subsequent inspection for certification...the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected Port and STBD sliding windows in Pilot House are cracked. 46 CFR 176.25-50
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2026
Resolved 13 March 2026
Resolution: Received photo from the operator of replaced windows.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 February 2026 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Smoke alarms not interconnected. Master reprogrammed detectors to be interconnected. 46 CFR 181.405(c)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 25 February 2026
Resolution: Master reprogrammed and sent video of properly operating smoke detectors.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 17 June 2024 Resolved
At each subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. Discovered fuel leak on inboard side of port fuel tank. Identify source of leak and repair to satisfaction of MI. 46 CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 1 July 2024
Resolution: Fuel leak found to be operator error.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 June 2024 Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times of the bilge pipe. The bilge suctions in the lazarette and sewage pump compartment did not have strainers. 46 CFR 182.25-5 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 17 September 2024
Resolution: New strainers installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2024 Resolved
At each subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. Discovered wet exhaust leaking at penetration on port side forward bulkhead of fuel tank compartment. Repair to satisfaction of the Marine Inspector. 46 CFR 176.804
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 3 July 2024
Resolution: Operator provided photograph of repaired wet exhaust.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2024 Resolved
At each subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. Starboard engine wet exhaust spool piece found to be heavily corroded. Repair to satisfaction of the Marine Inspector. 46 CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 3 July 2024
Resolution: Operator provided photograph of replaced exhaust component.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 June 2024 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame screens shall consist of a single screen of corrosion resistant wire of at least 30x30 mesh. Fuel tank vent was missing flame screen on port side. 46 CFR 182.20-35(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 17 September 2024
Resolution: Verified installation of flame screen
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 June 2024 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Discovered electrical 12V DC bus bar unsupported beneath pilothouse operating station. Properly mount bus bar to the satisfaction of the Marine Inspector. 46 CFR 183.220(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 17 September 2024
Resolution: Bus bar mounted satisfactorily
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 June 2024 Resolved
All cable and wire must, be installed with metal supports space not more than 24 inches apart, and in such a manner as to avoid damage. Several new electrical installations found under pilothouse operating station improperly supported. Support electric wires and cable. 46 CFR 183.340(b)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 17 September 2024
Resolution: Verified electrical installations supported/organized better
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 17 June 2024 Resolved
At each subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the inspection of all railings. Courses on upper deck were found broken, and/or not properly secured to the rail posts. 46 CFR 176.802
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 17 September 2024
Resolution: Verified installation of new upper rail courses
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 June 2024 Resolved
In general, compliance with the standards established by a recognized class society will be considered satisfactory evidence of the structural adequacy of a vessel. Transverse support beam for the main deck found with broken fiberglass tabbing at the port deck edge in the Engine Room. Repair to the satisfaction of the Marine Inspector. 46 CFR 177.10-1 (OLD T)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 3 July 2024
Resolution: Operator provided photograph of repaired deck beam fiberglass tabbing.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 June 2024 Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. Hydraulic hoses for steering ram found to be chafed into the wire reinforced construction. Replace hoses with SAE J-1942 standard. 46 CFR 182.30-1 (OLD T)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2024
Resolved 17 September 2024
Resolution: Verified installation of new hydraulic hoses for steering ram
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 June 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection and operation of all weather tight closures above the weather deck and the provisions for drainage of sea water from the exposed decks. Evidence of moisture and water intrusion found at the port main deck edge supports in the front bunk room. Restore watertight integrity to the satisfaction of the Marine Inspector. 46 CFR 176.802(a)(6)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2024
Resolved 17 September 2024
Resolution: Verified fiberglass repair
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 June 2024 Resolved
At each subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the inspection of weather decks. Identified the following suspect areas: 1) 24" x 24" soft spot identified on port side upper deck. 2) 12" x 12" soft spot identified on stbd side upper deck. 3) Port and Stbd main deck flexing along the outer exposed passageways at existing repair seams. Repair prior to credit drydock. 46 CFR 176.802
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 25 January 2025
Resolution: MI verified satisfactory repairs
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2024 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Ring life buoy on port bow did not have retroreflective material. Vessel marked ring buoy with retroreflective material in presence of attending MI. 46 CFR 185.604
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 17 June 2024
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 30 October 2023 Resolved
Each marine employer shall ensure that random drug tests conducted under this part are unannounced and that the dates for administering random tests are spread reasonably throughout the calendar year. Company has designated a vessel Master to serve as the Company Designated Employer Representative (DER). This arrangement does not allow for a random selection of crewmembers as intended by this regulation. Company to assign responsibilities of DER to an employee that is not one of the members that shall be randomly drug tested as required by this regulation.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2023
Resolution: Received notification that company has elected a new DER. Uploaded information on new DER to Special Note. DER has received supervisor level training and all employees have been trained in EAP.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 25 April 2023 Resolved
The movement of vessel shall be under the direction and control of the master or a licensed mate at all times. The master shall operate the vessel keeping the safety of the passengers and crew foremost in mind by directing the vessel in order to prevent a casualty. Vessel has been operating outside the conditions of the stability letter and has allowed passengers on the upper deck. In order to mitigate this requirement, vessel must provide the following addition: Create a chain at the upper and lower ends of the ladder to the second deck. On lower chain, place a sign at midpoint that reads "Maximum of 2 crew allowed on upper deck. No passengers allowed on upper deck while vessel is away from the dock." Chains will have a quick release device to allow crew to transit safely. 46 CFR 185.304(a)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2023
Resolved 13 September 2023
Resolution: Attended to inspect chain on ladder. All sat.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 6 October 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Repairs or alterations that affect the safety of the vessel include, but are not limited to: structural members. Operator reported a collision with another vessel that resulted in damage to the aft starboard quarter of the upper deck/house top. Submit repair proposal for approval and, once approved,make repairs to the satisfaction of the attending Marine Inspector prior to credit drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 6 April 2023
Resolution: Inspected repair. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 October 2022 Resolved
Unless otherwise specified, vessel owners must pay the fees required by this subpart before inspection or examination services are provided. Vessel is overdue and in collection status for 2021 User Fees. To resolve, contact FINCEN [phone withheld] OR EMAIL [email withheld]. Resolve prior to next inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 February 2025
Resolution: Verified user fees were up to date.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 March 2022 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation. The vessel currently does not have a valid Certificate of Documentation. 46 CFR 67.313
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2022
Resolved 13 April 2022
Resolution: Vessel has acquired a new Certificate of Documentation.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 30 March 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices and fire hazards must be corrected. The hose for the drip-less shaft seal was chafed from continuous contact with the shaft. The vessel is to provide a new hose for the drip-less shaft seal and to arrange the hose in such a way that the hose doesn't come in direct contact with the shaft. 46 CFR 176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 8 April 2022
Resolution: Vessel provided video of newly installed drip-less shaft seal hose.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 30 March 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. The vessel had dead end wires in the engine room that needed to be addressed/removed. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 25 April 2022
Resolution: Operator has cleared the dead end wires from the engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022 Resolved
A vessel's hull must not carry current as a conductor. The vessel's grounding wires were not properly wired and needs to be addressed. 46 CFR 183.370 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 25 April 2022
Resolution: Vessel's grounding wires have been properly wired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 March 2022 Resolved
On a vessel on an exposed or partially protected route, a watertight coaming with a height of at least 6 inches must be provided under each watertight door. The vessel currently has coaming for the weathertight door that is 4 inches high. 46 CFR 179.360(d)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 11 May 2022
Resolution: Vessel operator sent photos of the fixed coaming for the doors.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 March 2022 Resolved
The station transmitting radiotelegraph emissions must be identified by its call sign. The call sign must be transmitted with the telegraphy emission normally used by the station. The call signs on two FCC certifications were mismatched. Vessel operator to obtain a uniform call sign that aligns with both FCC certifications. 47 CFR 80.99 (a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 7 April 2022
Resolution: Vessel Rep has sent in the valid FCC Safety Radiotelephony Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 February 2021 Resolved
Each vessel certificated to operate on an oceans route in cold water must be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Vessel currently has IBA with capacity of 50 persons. Vessel is restricted to carrying no more than 48 passengers. For each additional crew member, passenger capacity decreases so that no more than 50 persons are onboard.
Action required: 705 - Other - as specified
Resolved 4 May 2021
Resolution: Operator put back in place lifesaving equipment. Passenger count returned to original allowance.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 March 2020 Resolved
Materials and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The Port Side AFT deck beam in the Lazarette Compartment is constructed of a wooden laminate. The bottom 1/3 of the wood is delaminated. Provide a repair proposal to the satisfaction of the Marine Inspector. 46 CFR 176.800
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2020
Resolved 20 March 2020
Resolution: Repair conducted to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 March 2020 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link. The hydrostatic release for the 02 IBA's were incorrectly installed, and would not have properly operated. The operator corrected the installation on the spot. 46 CFR 180.137(a)(1)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 March 2020
Resolved 17 March 2020
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 March 2020 Resolved
Vapor barriers must be provided where flammable combustible liquids or vapors are present, such as machinery spaces. The aft bulkhead of the engine room had an unsealed penetration. The penetration was sealed to the satisfaction of the attending Marine Inspector. 46 CFR 177.405(e)
Action required: 10 - Deficiency Rectified
Due 17 March 2020
Resolved 17 March 2020
Resolution: Correct on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 March 2019 Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. Excessive dirt and grime was discovered on the bilge strainer in the Forward Lazarrete space immediately aft of the Engine Room. Clean the strainer to allow proper suction IAW 46CFR182.25-5 to the satisfaction of the MI. 46CFR182.25-5 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2019
Resolved 3 April 2019
Resolution: Recieved photograph of replaced bilge pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 October 2018 Resolved
All engines must be water cooled and meet the requirements of this paragraph. Starboard side MDE sea chest intake ball value is damaged and needs to be replaced.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2018
Resolved 22 October 2018
Resolution: New valve installed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 16 October 2018 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel. Damaged FRP on the deck support strut in the forward void space, port side. needs to be repaired, increasing structural strength for the forward passenger deck.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2018
Resolved 22 October 2018
Resolution: FRP was repaired.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 October 2018 Resolved
A vessel must be provided with a main steering gear this is of adequate strength and capable of steering the vessel at all service speeds. Sterning gear transverse support beam weld is cracked, needs to be re-welded.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2018
Resolved 22 October 2018
Resolution: Weld was conducted on support beam.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 16 October 2018 Resolved
Each hatch exposed to the weather must be watertight and have a securing device that is attached to the hatch frame or coaming by hinges, captive chains, or another device to prevent its loss. MSD holding tank space hatch did not have a securing device, needs to have a securing device attached.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 October 2018
Resolved 22 October 2018
Resolution: Hatch securing device reattached.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 October 2018 Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. Through bulk head penetration, port side of steering gear room does not have vapor tight integrity. Opening must be filling with vapor tight material.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 October 2018
Resolved 22 October 2018
Resolution: Vapor tight foam re-installed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 October 2018 Resolved
A vessel must be provided with a main steering gear that is of adequate strength. Both starboard and port rudders have excessive play, no record of maintenance every being conducted on the rudder system, and unable to visual inspect bearings. These factors have lead me to require the steering gear system to be dissembled and inspected, and repaired accordingly.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2018
Resolved 22 October 2018
Resolution: Rudder assembly was taken apart and inspected, bushings were worn and replaced, no other system issues, rudder reassembled.
Construction/Loadline › Hull › Side Shell
Issued 20 February 2018 Resolved
Cross member and deck supports in the forward void space are cracking and separating. Provide a repair proposal and limit operations to 7 NM offshore. 46 CFR 177.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 28 February 2018
Resolution: Conducted visual inspection of repairs.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 February 2018 Resolved
Wiring throughout vessel is improperly installed with frequent loops. Adjust wiring to straighten out and shorten lengths.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 March 2018
Resolved 28 February 2018
Resolution: Looped wires were adjusted properly.
Engineering › Steering Gear System › Piping
Issued 20 February 2018 Resolved
In the space forward of the lazarette, hydraulic fittings at the bulkhead for the steering gear are corroded. Replace metallic fitting. 46CFR182.40-1(a)(1)(i)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2018
Resolved 28 February 2018
Resolution: Metallic fitting was replaced
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 20 February 2018 Resolved
Crew bunk room inaccessible due to excess stored items filling the space. Clean up space for safer access.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 20 February 2018
Resolution: Crew cleaned space, witnessed by inspection team.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 February 2018 Resolved
Electrical wiring in the crew bunk room was found running along the deck with no supports. Install supports for wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 20 February 2018
Resolution: Wiring supported properly on the spot.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 20 February 2018 Resolved
02 Engine Room bulkhead penetrations were found. Refill with appropriate material to ensure bulkhead is vapor tight. 46 CFR 182.35-1(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 20 February 2018
Resolution: Crew installed new insulation material on the spot.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 February 2018 Resolved
Generator had exposed moving parts posing a hazard to crew. Install guard to cover moving parts. 46 CFR 177.35-15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 20 February 2018
Resolution: Crew installed appropriate guard.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 20 February 2018 Resolved
Passenger area found with 02 plastic trash cans. Replace with metallic receptacles. 46 CFR 177.30-7
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 20 February 2018
Resolution: Crew replaced plastic trash cans with metallic ones.
Construction/Loadline › Structures › Deck Plating
Issued 16 February 2018 Resolved
Excessive mold found on the overheads of the crew bunk room space. Remove mold from overhead. 46 CFR 176.25-45
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 20 February 2018
Resolution: Crew removed mold, replaces with new material and coating.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 16 February 2018 Resolved
Generator exhaust piping missing hose clamps and tied off using a t-shirt. Install appropriate hose clamps. 46 CFR 182.20-20
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 20 February 2018
Resolution: Crew installed exhaust piping hose clamps.
Construction/Loadline › Hull › Bracket
Issued 24 June 2016 Resolved
Replace bolts on deck beam in forpeakat both forward and stbd shelf. Reinforce connection by sandwiching with wood of sufficient strength, 46 CFR 177.10(a)
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 6 July 2016
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 18 March 2014 Resolved
Repair or renew leaking MSD tank clean out pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2014
Resolved 26 March 2014
Resolution: Replaced leaking MSD tank clean out pipe.
Engineering › Diesel Engine (auxiliary) › Distributor (fuel injection)
Issued 12 June 2012 Resolved
Properly repair fuel oil leak and provide proper operation of the generator.
Action required: 705 - Other - as specified
Resolved 7 August 2012
Resolution: The center fuel injector piping was replaced and an operational test was conducted with no apparent leaks.
Fire Fighting › Fire Hydrants › Material
Issued 12 June 2012 Resolved
Replace the existing garden hose with commercial grade fire hose and nozzle
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 26 June 2012
Resolution: The hose was replaced with the proper hose.
Construction/Loadline › Hull › Hull Plating
Issued 7 December 2010 Resolved
Provide proper repairs to hull on starboard side area of delamination.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 December 2010
Resolution: received pictures from [name withheld] via e-mail which showed that the delaminated top coating on hull had been properly renewed to original condition.
Construction/Loadline › Hull › Transverse Frame
Issued 7 December 2010 Resolved
Properly repair patches on forward transverse bulkhead starboard side.
Condition: Improper/Lack of Maintenance
Due 7 January 2011
Resolved 16 December 2010
Resolution: received pictures from [name withheld] via e-mail which showed the forward transverse bulkhead seam had been renewed to original condition.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 March 2010 Resolved
Provide STBD side light lens cover that meets standards in international/inland rules.
Action required: 705 - Other - as specified
Due 31 March 2010
Resolved 8 April 2010
Resolution: Operator replaced STBD side light lens cover.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 March 2010 Resolved
Provide suitable arrangement to recover man overboard from water.
Action required: 705 - Other - as specified
Due 31 March 2010
Resolved 8 April 2010
Resolution: Operator provided ladder arrangement, life sling, and pulley system to assist in retrieving a person from the water.
Fire Fighting › Nozzles › Type
Issued 22 March 2010 Resolved
Provide fire hose nozzles that are corrosion resistant in accordance with 46 CFR 181.320 (d).
Action required: 705 - Other - as specified
Due 31 March 2010
Resolved 8 April 2010
Resolution: Operator provided fire hose nozzles that meet the requirement.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 March 2010 Resolved
Provide suitable marine grade wiring on generator feed line to breaker panel.
Action required: 705 - Other - as specified
Due 31 March 2010
Resolved 8 April 2010
Resolution: Operator replaced worn wiring with new marine grade wire.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 22 March 2010 Resolved
Provide covers for spare connection ports on junction box in engine room.
Action required: 705 - Other - as specified
Due 31 March 2010
Resolved 8 April 2010
Resolution: Operator provided covers for spare connection ports on junction box.
Engineering › Bilge Water Management System › Hose
Issued 22 March 2010 Resolved
Provide suitable discharge hose for hand bilge pump.
Action required: 705 - Other - as specified
Due 31 March 2010
Resolved 8 April 2010
Resolution: Operator provided suitable discharge hose for hand bilge pump. Tested pump, all sat.
Documentation › Markings/Placards › Warning Signs
Issued 22 March 2010 Resolved
Provide sign indicating crew only or no passengers allowed for upper deck.
Action required: 705 - Other - as specified
Due 31 March 2010
Resolved 8 April 2010
Resolution: Operator provided sign indicating crew only on the upper deck.
Documentation › Markings/Placards › Official Number (US)
Issued 22 March 2010 Resolved
Provide proof of permanently marked official number IAW 46 CFR 67.121
Action required: 705 - Other - as specified
Due 31 March 2010
Resolved 8 April 2010
Resolution: Operator permanently marked hull with official number.
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009 Resolved
Company did not have result/exemptions for pre-employment testing prior for individuals working in a safety sensitive position, as required by 46 CFR 16.210.
Due 15 January 2010
Resolved 15 December 2009
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009 Resolved
Arrangements not made for post-casualty testing as required by 46 CFR 16.240.
Due 15 January 2010
Resolved 15 December 2009
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009 Resolved
Alcohol testing devices not onboard as required by 46 CFR 4.
Due 15 January 2010
Resolved 15 December 2009
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009 Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company's drug and alcohol policy in accordance with 46 CFR 16.401.
Due 15 January 2010
Resolved 4 January 2010
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009 Resolved
Supervisors has no proof of 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 15 January 2010
Resolved 4 January 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 December 2008 Resolved
Repair port exhaust in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2009
Resolved 15 January 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 December 2008 Resolved
Repair port exhaust in second void from aft.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2009
Resolved 15 January 2009
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 4 June 2008 Resolved
Repair leak from STBD side inboard diesel fuel filter.
Due 4 July 2008
Resolved 15 June 2009
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 4 June 2008 Resolved
Prove proper operation of fixed fire extinguishing system (over ride). 46 CFR 181.420.b.
Due 4 July 2008
Resolved 12 June 2008
Resolution: Fire servicing tech rep tested system - all sat. The override worked normally and as expected with the electrical switchboard/panel in normal line-up. The panel had all switches set ''off'' during Annual (not the normal position if vessel is underway).
Stability › Weathertight Integrity › General
Issued 18 June 2007 Resolved
Complete permanent repairs to bow delamination prior to 30Nov07 in accordance with written repair proposal of 12Jul07.
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 14 January 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 June 2007 Resolved
Properly dead end wiring for chart plotter on the bridge.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 8 August 2007
Resolution: Corrected
Communications › Radio Communications › EPIRB
Issued 13 June 2007 Resolved
Make permanent repairs to EPIRB antenna. Vessel is restricted to less than 3 NM from shore until proof is provided.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 18 June 2007
Lifesaving › Lifefloat › Serviceable
Issued 13 June 2007 Resolved
Repair one 15 person lifefloat with approved repair kit.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 8 August 2007
Resolution: Corrected
Lifesaving › Lifebuoys › Serviceable
Issued 13 June 2007 Resolved
Repair ring buoy with approved repair kit.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 8 August 2007
Resolution: Corrected
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 13 June 2007 Resolved
Provide approved bracket for B-II extinguisher in below deck accommodation space.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 8 August 2007
Resolution: Corrected
Engineering › Bilge Water Management System › Not Operational
Issued 13 June 2007 Resolved
Repair inoperable light on bilge alarm panel for compartment 3.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 8 August 2007
Resolution: Corrected
Stability › Weathertight Integrity › General
Issued 13 June 2007 Resolved
Provide means to secure bridge window amidships.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 8 August 2007
Resolution: Corrected
Stability › Weathertight Integrity › General
Issued 13 June 2007 Resolved
Submit plans to repair delaminated deck area on bow.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 12 July 2007
Engineering › Bilge Water Management System › Hose
Issued 13 June 2007 Resolved
Double clamp flexible hose on engine room bilge piping.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 8 August 2007
Resolution: Corrected
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 13 June 2007 Resolved
Provide means of locking sewage overboard discharge valve when within 3 NM from shore.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 8 August 2007
Resolution: Corrected
Engineering › Steering Gear System › Fastener
Issued 13 June 2007 Resolved
Properly secure all bolts on steering arm in lazarette.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 8 August 2007
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 June 2007 Resolved
Properly dead end wiring in junction box in galley.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 8 August 2007
Resolution: Corrected
Electrical › Electric Generation Source (service) › Generator
Issued 13 June 2007 Resolved
Prove proper operation of generator and repair leak on gasket for generator fuel filter.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 8 August 2007
Resolution: Corrected
Operations/Management › Drills/Instruction › Fire
Issued 13 June 2007 Resolved
Perform satisfactory fire and man overboard drills prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2007
Resolved 13 June 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 13 June 2007 Resolved
Properly label all adult PFD stowage areas.
Action required: 705 - Other - as specified
Due 13 June 2007
Resolved 13 June 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 June 2007 Resolved
Replace expired aspirin in vessel first aid kit.
Action required: 705 - Other - as specified
Due 13 June 2007
Resolved 13 June 2007
Engineering › Diesel Engine (propulsion-electric) › Pump, High Pressure (fuel injection)
Issued 13 June 2007 Resolved
Prove proper operation of starboard main diesel engine prior to carrying passengers.
Action required: 705 - Other - as specified
Due 13 June 2007
Resolved 13 June 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 June 2006 Resolved
Post valid Certificate of inspection IAW 46 CFR 176.107
Due 30 June 2006
Resolved 6 September 2006
Documentation › Certificates/Documents › Stability Letter
Issued 14 June 2006 Resolved
Post stability letter at operating station IAW 46 CFR 176.306.
Due 30 June 2006
Resolved 6 September 2006
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 14 June 2006 Resolved
Provide up to date light list and coast pilot for vessel's routes IAW 46 CFR 183.420.
Due 30 June 2006
Resolved 6 September 2006
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 14 June 2006 Resolved
Provide current edition of Rules of the Road - edition (D) IAW 33 CFR 88.05.
Due 30 June 2006
Resolved 6 September 2006
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 14 June 2006 Resolved
Post Life jacket donning placards IAW 46 CRF 185.516.
Due 30 June 2006
Resolved 6 September 2006
Engineering › Bilge Water Management System › Interface Detector
Issued 14 June 2006 Resolved
Fasten the high water alarm sensor and bilge pump in fwd void space.
Due 30 June 2006
Resolved 14 June 2006
Electrical › Electric Supply System (service) › Cable
Issued 14 June 2006 Resolved
Properly fasten loose wires in the following spaces; lazarette (fwd bulkhead), engine room (aft bulkhead), Forepeak (high water alarm and aft bulkhead) IAW 46 CFR 183.340.
Due 30 June 2006
Resolved 6 September 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 June 2006 Resolved
Provide repair proposal for cracked gussets in forepeak prior to start.
Due 30 June 2006
Resolved 14 June 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 June 2006 Resolved
Repair all gussets in forepeak upon approved plans from attending Marine Inspector,
Due 30 June 2006
Resolved 6 September 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 June 2006 Resolved
Make permanent repairs to center main beam that has dropped on stern end of lazarette.
Due 30 June 2006
Resolved 6 September 2006
Stability › Watertight Integrity › General
Issued 14 June 2006 Resolved
Prove watertight integrity in all three compartments on fantail in way of scuttles and port side deck. All bilges shall be pumped dry and overhead and bulkheads shall be dry prior to test IAW 46 CFR 175-400 (Watertight).
Due 30 June 2006
Resolved 6 September 2006
Stability › Watertight Integrity › General
Issued 14 June 2006 Resolved
Prove watertight integrity in forepeak. All bilges shall be pumped dry and overhead and bulkheads shall be dry prior to test IAW 46 CFR 175-400 (Watertight). Attending Marine Inspector shall key on portside rub rail and below.
Due 30 June 2006
Resolved 6 September 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 June 2006 Resolved
Make port and stern light operational IAW 46 CFR 183.420.
Action required: 705 - Other - as specified
Resolved 14 June 2006
Lifesaving › Lifefloat › Float Free
Issued 14 June 2006 Resolved
Make all life floats float free IAW 46 CFR 180.130.
Action required: 705 - Other - as specified
Resolved 14 June 2006
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 14 June 2006 Resolved
Make 6 adult and 2 child type 1 PFD lights operational.
Action required: 705 - Other - as specified
Resolved 14 June 2006
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 14 June 2006 Resolved
Properly label 2 adult type 1 PFD's with vessels name.
Action required: 705 - Other - as specified
Resolved 14 June 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 23 March 2005 Resolved
Secured the top step of the ladder to the pilot house.
Due 23 April 2005
Resolved 2 June 2005
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 23 March 2005 Resolved
Provide proof current tides and currents tables.
Due 23 April 2005
Resolved 25 March 2005
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 23 March 2005 Resolved
Properly label child and adult PFD storage.
Due 23 April 2005
Resolved 2 June 2005
Stability › Weathertight Integrity › General
Issued 23 March 2005 Resolved
Provide proof that the pilot house is weathertight.
Due 23 April 2005
Resolved 2 June 2005
Lifesaving › Buoyant Apparatus › Lifeline
Issued 23 March 2005 Resolved
Renew the lifeline for both the port and starboard buoy apparatus.
Due 23 April 2005
Resolved 2 June 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 March 2005 Resolved
Renew the grab line for the life ring.
Due 23 April 2005
Resolved 2 June 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 March 2005 Resolved
Renew the waterlight lanyard for the life ring.
Due 23 April 2005
Resolved 2 June 2005
Stability › Weathertight Integrity › General
Issued 23 March 2005 Resolved
Renew the starboard crack bridge window.
Due 23 April 2005
Resolved 2 June 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 23 March 2005 Resolved
Properly secure the ladder for the engine room and forepeak compartment.
Due 23 April 2005
Resolved 2 June 2005
Stability › Watertight Integrity › General
Issued 23 March 2005 Resolved
Provide proof that the forepeak and #6 compartment is watertight.
Due 23 April 2005
Resolved 2 June 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 March 2005 Resolved
Tighten the port and starboard railing.
Due 23 April 2005
Resolved 2 June 2005
Construction/Loadline › Hull › Hull Plating
Issued 23 March 2005 Resolved
Repair the crack on the port beam IAW NVIC 8-87. Submit repair proposal to the attending marine inspector.
Due 23 April 2005
Resolved 2 June 2005
Construction/Loadline › Structures › Superstructure
Issued 23 March 2005 Resolved
Remove deck material circle in yellow around the pilot house and make it available for inspection.
Action required: 705 - Other - as specified
Due 30 March 2005
Resolved 25 March 2005
Construction/Loadline › Structures › Superstructure
Issued 23 March 2005 Resolved
Repair cracks around pilot house IAW NVIC 8-87 & submit repair proposal. Allowed the vessel to operate on the under the following the conditions: 1. No passengers are allowed on the upper deck. 2. Both port and starboard deck space around the pilothouse is blocked out.
Action required: 705 - Other - as specified
Due 17 June 2005
Resolved 13 October 2005
Lifesaving › Hand Flares › Quantity
Issued 23 March 2005 Resolved
Renew 1 red flare.
Due 23 April 2005
Resolved 23 March 2005
Documentation › Logs/Records › Drug Test Records
Issued 23 March 2005 Resolved
Provide proof of crew enrollment in a random drug testing program.
Due 23 April 2005
Resolved 23 March 2005
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 23 March 2005 Resolved
Provide proof of 50% of the crew is First Aid/CPR qualified.
Due 23 April 2005
Resolved 23 March 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 March 2005 Resolved
Renew the stern and starboard Navigation Lights.
Due 23 April 2005
Resolved 23 March 2005
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 23 March 2005 Resolved
Renew all PFDs marking with the vessel's name.
Due 23 April 2005
Resolved 23 March 2005
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 23 March 2005 Resolved
Remove the bucket in the engine room that is filled with oily water.
Due 23 April 2005
Resolved 23 March 2005
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 23 March 2005 Resolved
Hose clamp the generator exhaust piping.
Due 23 April 2005
Resolved 2 June 2005
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 23 March 2005 Resolved
Renew the port exhaust piping. Temporary patch is allowed. This requirement must be completed by 30 March 05.
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 2 June 2005
Stability › Intact Stability (when using lifting gear) › General
Issued 22 February 2005 Resolved
Conduct a simplified stability proof test IAW 46CFR 178.330.
Action required: 705 - Other - as specified
Due 23 April 2005
Resolved 2 June 2005
Construction/Loadline › Penetrations › Valve Flange
Issued 10 December 2004 Resolved
Properly repair or replace gate valve on port bilge overboard in fuel tank void. Provide a means to operatie the valve as well. This item shall be completed prior to 10FEB05.
Due 10 February 2005
Resolved 2 June 2005
Stability › Watertight Integrity › General
Issued 10 December 2004 Resolved
Prove proper operation and watertight integrity of deck hatches (three) on fantail.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 16 December 2004
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 10 December 2004 Resolved
Complete starboard fuel tank installation by topping off tank and making it available to inspection by a CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 16 December 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 29 November 2004 Resolved
Install cover or properly dead end receptable in front of bench on FWD portion of main deck cabin IAW 46CFR 183.210
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 1 December 2004
Stability › Watertight Integrity › General
Issued 29 November 2004 Resolved
Properly cap unused overboard discharge on STBD bulkhead - FWD in engine room. Currently there is an inoperable gate valve mounted there without any plumbing connected.
Due 15 December 2004
Resolved 1 December 2004
Stability › Watertight Integrity › General
Issued 29 November 2004 Resolved
Properly secure and make watertight capped overboard discharge (thru hull fitting) on STBD - aft bulkhead in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2004
Construction/Loadline › Penetrations › Valve Flange
Issued 29 November 2004 Resolved
Replace wasted port MDE raw water suction valve IAW 46CFR179.350
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2004
Construction/Loadline › Penetrations › Valve Flange
Issued 29 November 2004 Resolved
Install double hose clamps on ships generator overboard exhaust IAW 46CFR 182.430
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2004
Construction/Loadline › Penetrations › Valve Flange
Issued 29 November 2004 Resolved
Replace two inoperable gate valves for bilge overboard discharge in aft void space FWD of lazarette and in lazarette.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 1 December 2004
Stability › Watertight Integrity › General
Issued 29 November 2004 Resolved
Prove watertight intergrity of forepeak deck IAW 46CFR 171.50
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 16 December 2004
Stability › Watertight Integrity › General
Issued 29 November 2004 Resolved
Indentify cause of water seepage thru hull. Must be completed prior to receiving credit for drydock.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 10 December 2004
Resolution: [name withheld] from Monterey Bay Boatworks explained that the water weeping through the hull smelled extremely foul & apparantly had been trapped in the keel for sometime.McNeely waited days for the water to drain so that he could accomplish a good repair.
Engineering › Steering Gear System › Linkage
Issued 29 November 2004 Resolved
Install pin of appropriate size and bushing for linkage that secures the steering gear to the hydraulic ram.
Due 15 December 2004
Resolved 10 December 2004
Stability › Watertight Integrity › General
Issued 24 November 2004 Resolved
Properly seal all watertight bulkhead penetrations in engine room including fuel lines on stbd side and top bolt hole on stbd exhaust IAW 46CFR 179.212
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 10 December 2004
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 24 November 2004 Resolved
Install drip guard over breaker mounted on aft engineroom bulkhead.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 29 November 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 24 November 2004 Resolved
Replace light cover on light fixture over port engine IAW 46CFR 183.410
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 10 December 2004
Accommodation/Occupational Safety › Ventilation › General
Issued 24 November 2004 Resolved
Reattach ventilation fitting on outboard top of sewage tank on portside
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 1 December 2004
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 November 2004 Resolved
Remove and arrest furring on main transverse beams in engine room
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 16 December 2004
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 24 November 2004 Resolved
Properly attach deck stringers in lazarette and fuel compartment as indicated by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 10 December 2004
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 November 2004 Resolved
Properly reattach transverse beams to deck and hull on stbd side of FWD berthing space.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 10 December 2004
Construction/Loadline › Structures › Superstructure
Issued 24 November 2004 Resolved
All fiberglass repairs shall be made to the satisfaction of the attending Marine Inspector and IAW Navigation and Vessel Inspection Circulars (NVIC) 8-87.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 16 December 2004
Construction/Loadline › Hull › Side Shell
Issued 19 November 2004 Resolved
All fiberglass repairs; particularly items #6, #11, #13, and #16 issued at the drydock hull inspection on 18NOV04; shall be made to the satisfaction of the attending marine inspector and in accordance with navigation and vessel inspection circular (NVIC) 8-87.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2004
Resolved 24 November 2004
Resolution: Re-issued on separate CG-835 on 24NOV04 so that all deficiencies were documented on one document.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 November 2004 Resolved
Properly secure deck rails on port and starboard deck IAW 46CFR177.900. Must be completed prior to receiving credit for drydock.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 24 November 2004
Construction/Loadline › Penetrations › Pipe Flange
Issued 18 November 2004 Resolved
Properly seal all watertight bulkhead penetrations in way of collision bulkhead, engine room, void space under fantail, and lazarette IAW 46CFR179.212. Must be completed prior to receiving credit for drydock.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 24 November 2004
Resolution: Re-issued on separate CG-835 on 24NOV04 so that all deficiencies were documented on one document.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 November 2004 Resolved
Install cover on junction box in fuel tank void IAW 46CFR179.212. Must be completed prior to receiving credit for drydock.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 24 November 2004
Engineering › Bilge Water Management System › Pump
Issued 18 November 2004 Resolved
Properly secure and mount bilge pump, float switch, and piping in way of forepeak, forward berthing area, and lazarette IAW 46CFR181.300.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 24 November 2004
Construction/Loadline › Hull › Side Shell
Issued 18 November 2004 Resolved
Submit repair proposal for damage on port bow in way of rub rail IAW 46CFR176.700. Must be completed prior to receiving credit for drydock.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 24 November 2004
Construction/Loadline › Hull › Side Shell
Issued 18 November 2004 Resolved
Make area above ceiling on starboard side forward berthing area available for inspection IAW 46CFR176.610. Must be completed prior to receiving credit for drydock.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 24 November 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 November 2004 Resolved
Use metal supports to mount wiring that is currently over the engine IAW 46 CFR 183.340. Must be completed prior to receiving credit for drydock.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 24 November 2004
Engineering › Steering Gear System › Rudder Stock
Issued 18 November 2004 Resolved
Repair porous (washed out) welds on starboard rudder post. Must be completed prior to receiving credit for drydock.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 24 November 2004
Construction/Loadline › Hull › Transverse Frame
Issued 18 November 2004 Resolved
Repair delamination on transverse deck beams in overhead of forepeak in way of port and starboard side shell.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 24 November 2004
Resolution: Repair had previously been approved during annual inspection in JUN04. Operator just extended repair to all tranverse beams up to the bow.
Engineering › Steering Gear System › Fastener
Issued 18 November 2004 Resolved
Properly secure all through bolts for mounting bracket on port side rudder post.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 24 November 2004
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 18 November 2004 Resolved
Renew wasted set screw on starboard side stern tube.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 24 November 2004
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 November 2004 Resolved
Replace/repair all wasted or missing deck longitudinals in lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 24 November 2004
Resolution: Re-issued on separate CG-835 on 24NOV04 so that all deficiencies were documented on one document.
Engineering › Bilge Water Management System › Valve
Issued 18 November 2004 Resolved
Prove proper operation of overboard discharge gate valve in way of port side aft top bunk in aftmost berthing area IAW 46CFR176.802. Must be completed prior to receiving credit for drydock.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 24 November 2004
Fire Fighting › Fire Pumps › Power Source
Issued 18 November 2004 Resolved
Prove proper operation of fire pump on port side engine IAW 46CFR 181.300
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 16 December 2004
Stability › Watertight Integrity › General
Issued 18 November 2004 Resolved
Repair or properly remove and cap overboard discharge in FWD berthing area. Must be completed prior to receiving credit for drydock.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 29 November 2004
Electrical › Electrical Distribution System (service) › Panelboard
Issued 18 November 2004 Resolved
Install splash guard over wiring panel in engine room overhead amidships IAW 46CFR 183.330. Must be completed prior to receiving credit for drydock.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 29 November 2004
Stability › Watertight Integrity › General
Issued 18 November 2004 Resolved
Repair identified areas of delamination of fiberglass on hull IAW 46CFR 176.700. Must be completed prior to receiving credit for drydock.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 16 December 2004
Navigation › Piloting/Steering › Marine Charts
Issued 30 June 2004 Resolved
Provide chart with updated corrections.
Due 30 July 2004
Resolved 15 July 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 June 2004 Resolved
Renew eyewash for 1st aid kit.
Due 30 July 2004
Resolved 15 July 2004
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 30 June 2004 Resolved
Provide tide & current tables.
Due 30 July 2004
Resolved 15 July 2004
Navigation › Piloting/Steering › US Coast Pilot
Issued 30 June 2004 Resolved
Provide updated Coast Pilot & Light List.
Due 30 July 2004
Resolved 15 July 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 June 2004 Resolved
Provide supports for electrical wiring in way of fule tank compartment.
Due 30 July 2004
Resolved 15 July 2004
Stability › Watertight Integrity › General
Issued 30 June 2004 Resolved
Make collision bulkhead watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2004
Resolved 15 July 2004
Construction/Loadline › Structures › End Bulkhead
Issued 30 June 2004 Resolved
Delamination in fore peak void in way of deck support beam and collision bulkead at the deck to hull intersection. Submit repair proposal, for approval, to repair delamination.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2004
Resolved 15 July 2004
Engineering › Bilge Water Management System › Not Operational
Issued 30 June 2004 Resolved
Prove operation of the audible alarms for the engine room bilge pumps.
Due 30 July 2004
Resolved 15 July 2004
Electrical › Electric Generation Source (service)
Issued 26 April 2004 Resolved
AC power source selector switch box missing strain relief locknut. LEGACY COMPONENT DESC: Switch
Condition: Improper Installation
Due 26 May 2004
Resolved 1 June 2004
Electrical › Electric Generation Source (service)
Issued 26 April 2004 Resolved
Install approved metallic support fasteners in way of grounding conductor from AC power source selector swtich box to hull in Engine Room. LEGACY COMPONENT DESC: Grounding Conductor
Condition: Improper Installation
Due 26 May 2004
Resolved 1 June 2004
Electrical › Electrical Distribution System (service)
Issued 26 April 2004 Resolved
Behind AC Electrical Panel in pilothouse, fold back, tape and label electrical cable as a "Dead Ended Cable". LEGACY COMPONENT DESC: Panelboard
Condition: Improper Installation
Due 26 May 2004
Resolved 1 June 2004
Electrical › Electric Generation Source (service)
Issued 26 April 2004 Resolved
Vessel restricted from operating generator while passengers are on board due to lack of emergency shutdown while fixed fire fighting system is activated. LEGACY COMPONENT DESC: Generator
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2004
Resolved 1 June 2004
Resolution: Witnessed generator emergency shutdown upon activation of fixed firefighting system.
Electrical › Electric Generation Source (service)
Issued 26 April 2004 Resolved
Provide plans for approval of generator electrical shutdown circuit in way of the fixed fire fighting system. LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 26 May 2004
Resolved 1 June 2004
Resolution: Plans approved under plan review activity #2084873.
Lifesaving › Buoyant Apparatus
Issued 16 May 2003 Resolved
Repair as new damaged 15-person life float.
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 17 February 2004
Resolution: Renewed.
Navigation › Piloting/Steering
Issued 16 May 2003 Resolved
Provide current Light List, Coast Pilot, proof may be faxed. LEGACY COMPONENT DESC: Coast Guard Light List
Due 16 June 2003
Resolved 17 February 2004
Resolution: Provided.
Engineering › Bilge Water Management System
Issued 16 May 2003 Resolved
Remove excess oil in bilge, iaw 46CFR176.830.
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 17 February 2004
Resolution: Removed.
Engineering › Generator (propulsion-electric)
Issued 12 December 2002 Resolved
Provide plans and specification information for new installation of generator. Plans shall include electrical, mechanical and exhaust installation. The generator shall not be used until all plans and specifications are approved by an attending Marine Inspector.
Action required: 705 - Other - as specified
Due 20 March 2003
Resolved 1 June 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 24 May 2002 Resolved
Replace all expired items in First Aid kit with new items. LEGACY COMPONENT DESC: Medicine Chest
Due 29 June 2002
Resolved 18 February 2003
Pollution Prevention/Response › Prevention Equipment
Issued 24 May 2002 Resolved
Prove proper operation of bilge audible alarms. LEGACY COMPONENT DESC: Bilge Monitor
Due 29 June 2002
Resolved 18 February 2003
Resolution: Witnessed proper operation of alarms
Electrical
Issued 24 May 2002 Resolved
Properly clean and protect all battery posts in engineroom.
Due 29 June 2002
Resolved 18 February 2003
Documentation › Markings/Placards
Issued 24 May 2002 Resolved
Post two 12 person adult life jacket placards and update child life jacket placard to reflect eight child life jackes vice six. LEGACY COMPONENT DESC: Capacity Marking
Due 29 June 2002
Resolved 18 February 2003
Navigation › Piloting/Steering
Issued 24 May 2002 Resolved
Prove proper operation of compass light. LEGACY COMPONENT DESC: Steering Magnetic Compass
Due 29 June 2002
Resolved 18 February 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 24 May 2002 Resolved
Make both Main Diesel Engines exhaust tubes water tight in way of lazarette. LEGACY COMPONENT DESC: Piping (exhaust)
Due 29 June 2002
Resolved 18 February 2003
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 24 May 2002 Resolved
Add one child life jacket.
Due 29 May 2002
Resolved 29 May 2002
Resolution: Owner provided one more child life jacket.
Lifesaving › Buoyant Apparatus
Issued 24 May 2002 Resolved
Properly secure two weak links to Life floats, mark floats with vessels name and add spacers between life floats.
Due 29 May 2002
Resolved 29 May 2002
Resolution: Week links secured to life floats.
Lifesaving › Lifebuoys
Issued 24 May 2002 Resolved
Properly mark lifebuoy with vessels name.
Due 29 May 2002
Resolved 29 May 2002
Resolution: Lifebuoy has been marked with vessels name.
Communications › Radio Communications › EPIRB
Issued 24 May 2002 Resolved
Properly log monthly EPIRB tests.
Due 29 May 2002
Resolved 29 May 2002
Resolution: EPIRB tests are being logged.
Personnel › Training
Issued 24 May 2002 Resolved
Abtain certification for First Aid/CPR. LEGACY COMPONENT DESC: First Aid/CPR
Due 29 June 2002
Resolved 18 February 2003
Engineering
Issued 19 November 2001 Resolved
Renew all fuel hoses on the generator using approved hose. Hose must meet or exceed 46 CFR 182.720 or SAE J1942.
Condition: Unknown
Due 21 December 2001
Resolved 18 February 2003
Construction/Loadline
Issued 19 November 2001 Resolved
Make all PVC or plastic bulkhead penetrations watertight as required by 46 CFR 182.720(d)(1)
Condition: Unknown
Due 21 December 2001
Resolved 18 February 2003
Electrical
Issued 19 November 2001 Resolved
Install battery on generator in accordance with 46 CFR 183.350.
Condition: Unknown
Due 21 December 2001
Resolved 18 February 2003
Engineering
Issued 30 October 2001 Resolved
Machine guards shall be placed on stbd side engine fire pump installation iaw 46 CFR 177.960.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Construction/Loadline
Issued 30 October 2001 Resolved
Prove watertight intergrity of all flush hatches located on the main deck.
Condition: Unknown
Due 1 November 2001
Resolved 1 November 2001
Construction/Loadline
Issued 30 October 2001 Resolved
Properly repair delaminated areas in the chain locker, port & stbd side outboard near aft bulkhead, iaw NVIC 8-87.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Electrical
Issued 30 October 2001 Resolved
until plans are approved, newly installed generator shall not be used.
Condition: Unknown
Due 30 November 2001
Resolved 17 February 2004
Resolution: Cleared due to this being a redundant deficiency. See item 1 issued on 12dec2002 under activity 1716868 which was kept open.
Fire Fighting
Issued 9 May 2001 Resolved
HAVE ALL PORTABLE FIRE EXTINGUISHERS SERVICED IAW 46 CFR 176.810. _x001C_ COMPLETE PRIOR TO CARRIAGE OF PASSENGERS. FAX OF SERVICING CERTIFICATE TO THIS OFFICE WILL SUFFICE.
Condition: Unknown
Due 9 June 2001
Resolved 10 May 2001
Navigation
Issued 9 May 2001 Resolved
PROVIDE LIGHT FOR MAGNETIC COMPASS. COMPLETE PRIOR TO CARRYING PASSENGERS IN NON-DAYLIGHT HOURS.
Condition: Unknown
Due 9 May 2001
Resolved 9 May 2001
Unknown
Issued 9 May 2001 Resolved
PROVE PROPER OPERATION OF SINGLE-SIDE BAND RADIO. _x001C_ COMPLETE PRIOR TO TAKING PASSENGERS MORE THAN 20 NM FROM SHORE.
Condition: Unknown
Due 9 May 2001
Resolved 9 May 2001
Navigation
Issued 9 May 2001 Resolved
REPAIR STARBOARD RUDDER POST.
Condition: Unknown
Due 9 May 2001
Resolved 9 May 2001
Lifesaving
Issued 9 May 2001 Resolved
PROVIDE SPACERS FOR LIFEFLOATS.
Condition: Unknown
Due 9 May 2001
Resolved 9 May 2001
Lifesaving
Issued 9 May 2001 Resolved
PERMANENTLY ATTACH LIFEFLOAT PAINTERS TO WEAK LINKS.
Condition: Unknown
Due 9 May 2001
Resolved 9 May 2001
Accommodation/Occupational Safety
Issued 9 May 2001 Resolved
REPAIR DECK RAIL PORTSIDE, AMIDSHIPS.
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Lifesaving
Issued 9 May 2001 Resolved
ATTACH WATERLIGHT TO PORT LIFEFLOAT.
Condition: Unknown
Due 9 May 2001
Resolved 9 May 2001
Construction/Loadline
Issued 9 May 2001 Resolved
ADD A GASKET TO HATCH COVER FOR AFT LAZARETTE.
Condition: Unknown
Due 9 May 2001
Resolved 9 May 2001
Lifesaving
Issued 9 May 2001 Resolved
PROVIDE HOSE FOR PORTABLE BILGE PUMP.
Condition: Unknown
Due 9 May 2001
Resolved 9 May 2001
Fire Fighting
Issued 9 May 2001 Resolved
HAVE FIXED FIREFIGHTING IN ENGINEROOM SERVICED IAW 46 CFR 176.810. _x001C_ COMPLETE PRIOR TO CARRIAGE OF PASSENGERS. FAX OF SERVICING CERTIFICATE TO THIS OFFICE WILL SUFFICE.COMPLETE PRIOR TO CARRIAGE OF PASSENGERS. FAX OF SERVICING CERTIFICATE TO THIS OFFICE WILL SUFFICE.
Condition: Unknown
Due 9 June 2001
Resolved 10 May 2001
Lifesaving
Issued 31 March 2000 Resolved
CONDUCT FIRE AND MAN OVERBOARD DRILLS.
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Fire Fighting
Issued 6 March 1997 Resolved
FREE UP OR REPLACE THE AFTER MAIN PASSENGER ACCOMMODATION FIRE EXTINGUISHERBRACKET, SUPPORT ARM INOPERATIVE.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Construction/Loadline
Issued 6 March 1997 Resolved
REGLASS FORWARD KINGPOST FOUNDATION TO HULL SUPPORT STRUCTURE. CURRENT FIBERGLASS HAS BEEN BROKEN LOOSE FROM HULL.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Engineering
Issued 6 March 1997 Resolved
PROPOSE AND COMPLETE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR,REPAIRS TO PORT PROPULSION ENGINE EXHAUST PIPING LOCATED IN THE VOID SPACE AFT OF THE FUEL TANK COMPARTMENT.
Condition: Unknown
Due 6 April 1997
Resolved 14 April 1997
Engineering
Issued 16 March 1995 Resolved
RENEW STBD FUEL FILL HOSE AND INSTALL BONDING WIRE ON BOTH FILL HOSES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 April 1995
Resolved 10 May 1995
Engineering
Issued 16 March 1995 Resolved
REMOVE PETCOCK FROM GENERATOR FUEL STRAINER.
Condition: Unknown
Due 16 April 1995
Resolved 10 May 1995
Navigation
Issued 16 March 1995 Resolved
INSTALL THIMBLE ON ANCHOR LINE AND MOUSE SHACKLE.
Condition: Unknown
Due 16 April 1995
Resolved 10 May 1995
Accommodation/Occupational Safety
Issued 16 March 1995 Resolved
RENEW OIL POLLUTION PLACARD.
Condition: Unknown
Due 16 April 1995
Resolved 10 May 1995
Accommodation/Occupational Safety
Issued 16 March 1995 Resolved
REPAIR FIBERGLASS DELAMINATION IN FOREPEAK.
Condition: Unknown
Due 16 April 1995
Resolved 10 May 1995
Accommodation/Occupational Safety
Issued 16 March 1995 Resolved
RENEW PILOT HOUSE WINDOW ON STBD SIDE WHERE FRACTURED
Condition: Unknown
Due 16 April 1995
Resolved 10 May 1995
Lifesaving
Issued 16 March 1995 Resolved
RENEW ONE LIFEFLOAT PADDLES
Condition: Unknown
Due 16 April 1995
Resolved 10 May 1995
Navigation
Issued 16 March 1995 Resolved
PROVE OPERATION OF VESSEL'S SINGLE SIDE BAND RADIO. VESSEL IS RESTRICTED TO NOT MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL CORRECTED.
Condition: Unknown
Due 16 April 1995
Resolved 10 May 1995
Engineering
Issued 16 March 1995 Resolved
INSTALL FUEL SHUT OFF VALVES ON BOTH MAIN ENGINES.
Condition: Unknown
Due 16 April 1995
Resolved 10 May 1995
Navigation
Issued 10 March 1994 Resolved
PROVE PROPER OPERATION OF VESSELS SSB-AM RADIO.
Condition: Unknown
Due 8 April 1994
Resolved 4 April 1994
Navigation
Issued 8 April 1992 Resolved
PROVE OPERATION OF RADAR OR REMOVE FROM VESSEL.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Navigation
Issued 8 April 1992 Resolved
SSB RADIO REMOVED FROM VESSEL BY OPERATOR DUE TO CABIN TOP LEAK. BUILDER TOFABRICATE NEW CABIN TOP AND SUBMIT PLANS TO MOBMS FOR REVIEW.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Unknown
Issued 13 March 1991 Resolved
INSTALL A WARNING DEVICE VISIBLE OR AUDIBLE AT THE ENGINE OPERATION STATIONTO INDICATE ANY FAILURE OF WATER FLOW IN THE EXHAUST COOLING SYSTEM OF BOTHMAIN ENGINES.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Unknown
Issued 30 March 1988 Resolved
PROVIDE DOUBLE HOSE CLAMPS FOR ALL FLEXIBLE PIPE CONNECTIONS.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Unknown
Issued 30 March 1988 Resolved
CLEAN VESSEL AND MAKE READY FOR PASSENGERS.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Unknown
Issued 30 March 1988 Resolved
REMOVE ALL EXCESS WIRING FROM VESSEL
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Unknown
Issued 30 March 1988 Resolved
MAKE ALL WIRE CONNECTIONS IN JUNCTION BOXES OR WITH APPROVED PRESSURE CONNECTIONS.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Unknown
Issued 30 March 1988 Resolved
PROVIDE WT. BOX FOR FLAMES.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Unknown
Issued 30 March 1988 Resolved
CHANGE CPFD MARKING FROM 6 TO 7.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Unknown
Issued 30 March 1988 Resolved
PROVE PROPER OPS. OF BOW LIGHT AND COVER.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Unknown
Issued 30 March 1988 Resolved
EFFECT WELDED REPAIRS TO LEAKS IN BOTH MDE EXHAUST LINES IN LAZARETTE.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Unknown
Issued 30 March 1988 Resolved
PROPERLY BRACKET HYDRAULIC PIPING IN LAZARETTE.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Unknown
Issued 30 March 1988 Resolved
PERM SECURE 2 BATTERY BOXES IN ENGINEROOM.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Lifesaving
Issued 27 January 1987 Resolved
PROVIDE SECURING BRACKET AFT OF BUOYANT APPARATUS.
Condition: Unknown
Due 27 January 1987
Resolved 27 January 1987

Casualty record · 2

27 February 2007Routine · role: Involved in a Marine Casualty · activity 2891607
22 April 2024Routine · role: Involved in a Marine Casualty · activity 7902082
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.