Records from 1985 to 2009. Most recent: inspection, 11 May 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 38
11 May 2009
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3472473
25 June 2008
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3247534
26 June 2007
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2974353
13 April 2007
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2907080
26 June 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2691951
7 July 2005
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2418070
25 April 2005
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2342138
24 June 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2109402
12 May 2003
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1793476
28 May 2002
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1621872
12 June 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1472178
18 May 2001
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1450630
9 June 2000
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1461295
14 April 2000
Examination of Repairs
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1454801
21 May 1999
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 808002
12 August 1997
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 782560
19 July 1995
Deficiency Check · MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 878613
19 April 1995
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 865479
18 July 1994
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 866678
15 June 1993
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1151679
12 May 1993
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1146571
27 May 1992
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1270919
4 June 1991
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 928463
29 April 1991
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1211305
7 June 1990
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 902688
17 April 1990
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1238635
30 June 1989
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1339032
14 June 1988
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1044696
31 March 1988
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 991863
25 January 1988
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1321798
15 January 1988
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1011609
15 January 1988
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1011611
8 July 1987
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1323647
26 August 1986
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 989729
28 May 1986
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 987265
7 May 1986
Credit Drydock
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 994731
3 June 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1292033
2 May 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1288796
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 26 June 2007
Resolved
Provide proper operation of fixed fire extinguishing system.
Condition: Improper Installation
Due 9 July 2007
Resolved 2 July 2007
Resolution: Witnessed proper operation of fire extinguishing system. ALL SAT.
Fire Fighting › Fire Bucket › Quantity
Issued 26 June 2007
Resolved
Provide three (3) 2 .5 gallon fire buckets.
Condition: Unknown
Due 9 July 2007
Resolved 2 July 2007
Resolution: Fire buckets provided. ALL SAT.
Engineering › Fuel Oil Service System › Filter
Issued 26 June 2007
Resolved
Install bowl for raycore fuel filter.
Condition: Improper/Lack of Maintenance
Due 9 July 2007
Resolved 2 July 2007
Resolution: Raycore bowl installed. ALL SAT.
Engineering › Bilge Water Management System › Not Operational
Issued 26 June 2007
Resolved
Prove proper operation of bilge alarm system.
Condition: Improper/Lack of Maintenance
Due 9 July 2007
Resolved 2 July 2007
Resolution: Witnessed proper operation of bilge system. ALL SAT.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 April 2005
Resolved
Double hose clamp all hose fittings in line with the through hull valve.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 April 2005
Resolved 21 April 2005
Resolution: All fittings in line with the through hull valve have been doubled hose clamped.
Engineering › Steering Gear System › Rudder Stock
Issued 7 April 2005
Resolved
Secure the rudder post in the skeg to keep it from popping out.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2005
Resolved 21 April 2005
Resolution: Rudder skeg secured in the skeg.
Construction/Loadline
Issued 19 July 1995
Resolved
RENEW SALT WATER HOSE FROM STRAINER TO ENGINE
Condition: Unknown
Due 26 July 1995
Resolved 17 August 1995
Accommodation/Occupational Safety
Issued 19 July 1995
Resolved
POST EMERGENCY CHECKOFF LIST IN ACCORDANCE WITH 46 CFR 185.25-5_x001C_
Condition: Unknown
Due 26 July 1995
Resolved 17 August 1995
Documentation
Issued 19 July 1995
Resolved
PROVIDE FCC RADIO OPERATORS PERMIT
Condition: Unknown
Due 26 July 1995
Resolved 24 August 1995
Lifesaving
Issued 19 July 1995
Resolved
STENCIL VESSEL NAME ON 2 ADULT AND 1 CHILD PFD
Condition: Unknown
Due 20 July 1995
Resolved 20 July 1995
Documentation
Issued 19 July 1995
Resolved
POST BOTH PAGES OF COI
Condition: Unknown
Due 26 July 1995
Resolved 17 August 1995
Lifesaving
Issued 19 July 1995
Resolved
RENEW RING BUOY GRAB LINE
Condition: Unknown
Due 26 July 1995
Resolved 17 August 1995
Documentation
Issued 19 July 1995
Resolved
PROVIDE FCC SAFETY CERTIFICATE
Condition: Unknown
Due 22 September 1995
Resolved 22 September 1995
Lifesaving
Issued 18 July 1994
Resolved
PROVIDE TWO (2) ADULT LIFE PRESERVERS PRIOR TO THE CARRIAGE OF FOURTEEN (14) PASSENGERS. VESSEL IS LIMITED TO TWELVE (12) PASSENGERS.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Electrical
Issued 18 July 1994
Resolved
SECURE EXTRA HEAT SENSOR WIRING FOR WATER TEMPERATURE GUAGE IN ENGINE COMPARTMENT.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Electrical
Issued 18 July 1994
Resolved
EMERGENCY LIGHT SOURCE MISSING. CORRECTED ON THE SPOT.
Condition: Unknown
Due 21 July 1994
Resolved 21 July 1994
Lifesaving
Issued 18 July 1994
Resolved
PROVIDE ADDITIONAL WORDING "UNDER SEAT" TO THE EMERGENCY FUEL SHUT-OFF MARKING.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Unknown
Issued 18 July 1994
Resolved
PROVIDE EVIDENCE THAT YOU COMPLY WITH A MARINE EMPLOYER DRUG SCREENING PROGRAM IN ACCORDANCE WITH 46 CFR PART 16.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Engineering
Issued 27 May 1992
Resolved
REPLACE DIESEL ENGINE FUEL HOSES (2) WITH APPROVED HOSE MEETING 46CFR 182.20-40.
Condition: Unknown
Due 27 May 1992
Resolved 27 May 1992
Lifesaving
Issued 28 May 1986
Resolved
REPLACE 5 ADULT PFD'S, PASSENGERS REDUCEDE TO TOTAL 10 UNTIL PFD'S ONBOARD.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986