Records from 2016 to 2025. Most recent: inspection, 8 August 2025.
Inspection history · 16
8 August 2025
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8332831
7 July 2025
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8111978
8 July 2024
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7932358
2 April 2024
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7878519
6 July 2023
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7700459
13 July 2022
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7469617
5 April 2022
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7405303
13 July 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7254532
8 July 2020
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6987720
1 April 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6933655
10 July 2019
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6743400
11 July 2018
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6475701
17 April 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6393926
12 July 2017
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6206794
14 July 2016
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5940957
20 April 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5859223
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 July 2025
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Portable fire extinguishers were not being inspected monthly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 21 July 2025
Resolution: Included fire extinguisher checks to their checks log.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 July 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Life ring buoy's grab line showed significant UV damage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 21 July 2025
Resolution: replaced life buoy.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 July 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts and nautical publications. Chart on board is not kept up-to-date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 21 July 2025
Resolution: purchased new pubs.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 7 July 2025
Resolved
Each vessel must be equipped with at least two operable portable battery lights. Portable battery needed replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 21 July 2025
Resolution: purchased new portable lights.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 July 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel had exposed wires in the operator's console.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 26 July 2021
Resolution: Vessel terminated exposed wires.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 July 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. The vessel's first aid kit had expired medication and equipment inside.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 26 July 2021
Resolution: Vessel replaced espired equipment in the first aid kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 July 2021
Resolved
A submersible electric bilge pump may be used as a power bilge pump only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that a positive shutoff valve is installed at the hull penetration. The vessel did not have a positive action valve installed at the hull penetration.
Rectify prior to next drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 5 April 2022
Resolution: Operator installed a positive action valve for the bilge system.