Records from 2016 to 2026. Most recent: inspection, 11 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 20
11 May 2026
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8371198
7 April 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8344255
14 April 2025
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8111342
10 June 2024
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7926929
9 April 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7888199
12 May 2023
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7690670
14 June 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7476278
24 March 2022
Drydock Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7411553
8 June 2021
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7219736
3 May 2021
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7181474
14 April 2020
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6936824
14 April 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6943230
4 March 2020
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6919421
29 May 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6690901
16 May 2018
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6416139
12 March 2018
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6371872
29 May 2017
Type not recorded
No type recorded · Station St Inigoes · USCG East District (CGD-E) · Activity 6161089
18 April 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6125957
18 May 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5872896
24 March 2016
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5832820
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 April 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel only had 29 of the required 30 adult life jackets.
46 CFR 180.71(a)
Action required: 705 - Other - as specified
Resolved 21 May 2025
Resolution: Vessel acquired additional life jacket, sent photo proof to MI.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 June 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel did not have up to date paper or electronic charts on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 24 June 2024
Resolution: O/O sent image of uploaded charts with most recent edition. Uploaded image to documents.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 June 2022
Resolved
A pre-engineered fixed gas fire extinguishing system must be installed IAW the manufacturers manual. Fireboy had safety pin installed and not readily available for use in the event of an emergency. Require fire company to service and provide new servicing report to the satisfaction of the USCG marine inspector. 46CFR181.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2022
Resolved 15 July 2022
Resolution: CID approved pre-engineered system after thorough discussion with team, to include AJMI's and review of evidence.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 June 2022
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Primary bilge pump is not operable. 46CFR182.500
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2022
Resolved 8 July 2022
Resolution: Witnessed successful operation of electric submersible bilge pump.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 14 June 2022
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. New crewmember is not adequately trained on fire protection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 8 August 2022
Resolution: Master completed drills with crew and logged.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 June 2022
Resolved
A vessel must be provided with an auxiliary means of steering where satisifactory to the [name withheld] emergency tiller needs to be descaled and provide evidence that it can fit properly on steering post. 46CFR182.620(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 8 August 2022
Resolution: Tiller was descaled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 June 2022
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3FT in length but not more than 6FT. Vessel's life buoy waterlight's lanyard is more than 6FT. 46CFR180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 8 August 2022
Resolution: Life Ring Buoy's floating water light lanyard was shortened.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 June 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Vessel had outdated charts. 46CFR184.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 8 August 2022
Resolution: Captain recieved updated Charts.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 June 2022
Resolved
On a vessel of at least 26 feet in length, must have a visual and audible alarm provided at the operating station to indicate a high water level in a space with a through-hull fitting below the deepest load waterlight, a machinery space bilge, bilge well, shaft alley, or other space subject to flooding from sea water piping within the space as well as a space with a non-watertight closure or hatch on the main deck. Vessel does not have a high water alarm in the aft locations as required. 46CFR182.530(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2022
Resolved 8 August 2022
Resolution: Due to all spaces with through hulls being open to each other, CID approved the location of the high water alarm in the forward location of the vessel.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 14 June 2022
Resolved
Each vessel that operates with more than 16 individuals on board must have at at least 2 individuals certified in first aid and at least 2 individuals certified in CPR. Vessel only have one certification on board at the time of inspection. Owner needs to provide proof of at least two individuals on board with valid certification in both CPR and First-Aid. 46CFR28.210(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2022
Resolved 8 July 2022
Resolution: Deckhand provided document showing current first aid and CPR training.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 3 May 2021
Resolved
Each life jacket must be marked with Type 1 retroreflective material or to standard specified by the Commandant; ring buoy and life jackets fitted with tape not showing SOLAS markings; provide demonsrtation of tape meeting standard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 8 June 2021
Resolution: All lifejacket and lifefloat retro has been renewed with SOLAS retro-reflective tape.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 May 2021
Resolved
Each vessel must carry an adequate and up to date Coast Guard light list. Light list is out of date; provide proof of updated list to meet standard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 8 June 2021
Resolution: Operator had onboard a 2021 copy of the Coast Guard light list.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 3 May 2021
Resolved
Each disposable hydrostatic release unit must be marked wtih an expiration date of two years after the date on which the unit is installed. Hydrostatic release on EPIRB not labled with expiration date; label appropriately.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 8 June 2021
Resolution: EPIRB hydrostatic release had been marked with the expiration date.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 3 May 2021
Resolved
Owner or managing operator must provide satisfactory evidence of the required servicing to the marine marine inspector. fire servicing record out of date; provide updated record or correspondence with date attached.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 8 June 2021
Resolution: Operator had onboard copy of most recent fire servicing certifiate.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 May 2021
Resolved
Each floating water light must be approved in accordance with 160.10; two water lights outfitted with incorrect battery; replace to fit manufacturer specifications.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 8 June 2021
Resolution: RLB water lights had correct battery installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 April 2020
Resolved
Portable fire extinguisher required at the vessels operating station is corroded around the mid-body of the tank. Required vessel owner to replace the extinguisher with a CG-approved 10:B-C extinguisher within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2020
Resolved 22 April 2020
Resolution: Owner provided proper proof of new 10:B-C Fire Extinguisher mounted at operating station and new servicing tag
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 May 2019
Resolved
Vessel does not have valid EPIRB registration form onboard vessel. Outfit vessel with registration form.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 30 May 2019
Resolution: Emailed picture of valid EPIRB registration form.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 May 2019
Resolved
Vessel does not have valid alcohol testing strips onboard. Outfit vessel with neew alcohol testing strips.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2019
Resolved 30 May 2019
Resolution: Vessel owner emailed pictures of valid alcohol testing strips.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 18 April 2017
Resolved
Pre-engineered fixed firefighting cylinder gauge indicated system required re-charging. Firefighting systems are required to be properly maitained in accordance with manufacturer's instructions. Provide servicing technician's service report to the attending CGMI to the satisfaction of the attending CGMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2017
Resolved 20 April 2017
Resolution: Owner had pre-engineered fixed fire system serviced by qualified servicing technician. Cleared CG-835.
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 May 2016
Resolved
Batteries were not properly secured against shifting with motion of the boat. 46CFR185 05-20
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 13 June 2016
Resolution: Received photos via email of the proper battery installation. 835 item was cleared.