Records from 1985 to 2017. Most recent: inspection, 16 October 2017.
Inspection history · 91
16 October 2017
Administrative Inspection · Loadline Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6288543
5 June 2014
COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4881135
26 March 2014
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4823293
26 July 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4391253
29 May 2012
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4327318
25 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4231738
28 December 2010
COI Inspection · Drydock Extension
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3912462
2 March 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3688392
8 February 2010
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3667306
2 February 2010
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3684504
1 July 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3624970
15 April 2009
Periodic Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3456601
8 January 2009
Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3390918
17 September 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3326944
28 January 2008
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3137848
26 October 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3087608
15 May 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2932791
23 January 2007
Annual Inspection · Construction Oversight · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2860050
26 October 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2820101
19 July 2006
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2717959
8 February 2006
Underwater Inspection in lieu of Drydock
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2582983
19 January 2006
COI Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2567843
8 November 2005
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2530987
30 April 2005
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2346699
9 March 2004
Periodic Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2021262
29 January 2004
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1996475
22 May 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1799091
20 February 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1746881
24 September 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1692231
24 June 2002
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1646620
26 May 2002
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1625627
21 March 2002
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1495475
11 March 2002
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1482286
2 June 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1432524
22 May 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 53823
14 March 2001
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1462198
2 February 2001
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1466744
22 May 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049413
31 March 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397390
29 March 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 816453
14 October 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1123134
3 February 1999
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1473612
23 December 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 808106
1 June 1998
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1399003
5 March 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1124010
9 February 1998
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1449017
15 September 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1086131
5 April 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 141167
4 February 1997
Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1449997
13 March 1996
Hull Examination · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1451048
13 February 1996
Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1405856
10 February 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357009
13 June 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 98504
14 March 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399989
4 February 1994
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463069
21 December 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 849554
25 March 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 8626
17 March 1993
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1146386
12 February 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1145725
19 August 1992
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 942672
25 July 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 169883
22 July 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 33310
23 March 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1261763
29 October 1991
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 944067
26 September 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1251170
7 August 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 932760
5 July 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1255533
15 February 1991
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 942611
1 October 1990
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1228218
17 July 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234558
29 May 1990
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1239811
30 April 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922780
12 December 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1217987
28 August 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1034277
26 April 1989
COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1035095
6 April 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1348713
27 January 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1042364
10 November 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1202797
10 October 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1341242
12 July 1988
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1210491
8 June 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1204244
1 June 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 897545
27 January 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322577
17 December 1987
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009381
15 October 1987
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009375
20 May 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1028507
6 May 1987
COI Inspection · Drydock Extension
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1335256
21 May 1986
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1297437
25 September 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1298060
25 June 1985
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1289118
6 May 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 980456
Operations/Management › Pollution › Control of Garbage
Issued 5 June 2014
Resolved
The waste management plan needs to be updated to revised MARPOL standards which does not allow the discharge of comminuted garbage within 12 miles from land. Rig must also immediately discontinue the discharge of food waste into the sea. MARPOL Annex V/6.
Action required: 705 - Other - as specified
Due 5 August 2014
Resolved 4 August 2014
Resolution: Received email of new updated waste management plan containing the new MARPOL Annex V regulations satisfying the outstanding requirement.
Documentation › Logs/Records › Oil Record Book
Issued 5 June 2014
Resolved
OWS operations shall be recorded in the Official Oil Record Book. MARPOL Annex I/17.
Action required: 705 - Other - as specified
Due 5 July 2014
Resolved 9 June 2014
Resolution: Received report from the rig stating that OWS operations are now being recorded into the Oil Record Book.
Lifesaving › Liferaft Equipment › Instructions (immediate action)
Issued 5 June 2014
Resolved
Liferaft station launching instructions are either missing or faded making them unable to read. Provide liferaft launching instructions for both liferaft stations. 46CFR108.655
Action required: 705 - Other - as specified
Due 5 July 2014
Resolved 16 June 2014
Resolution: Received email from rig with photos illustrating new liferaft placards have been installed satisfying the outstanding requirement.
Lifesaving › Inflatable Liferafts › Float Free
Issued 5 June 2014
Resolved
Ensure proper stowage of liferafts. Ensure turnbuckles and straps are suitably adjusted while liferaft is in the cradle. 46CFR108.530(c)(5).
Action required: 705 - Other - as specified
Due 5 June 2014
Resolved 5 June 2014
Resolution: Deficiency was rectified during the inspection with new turnbuckles and shackles installed and ensured the straps were tightened and all liferaft stowage arrangements were satisfactory.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 June 2014
Resolved
Ensure self-igniting lights on ring buoys are installed with approved batteries listed on the light by the manufacturer. 46CFR160.010.
Action required: 705 - Other - as specified
Due 5 July 2014
Resolved 9 June 2014
Resolution: Recieved and accepted report with pics from the rig showing new approved batteries installed into the ring buoy lights.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 5 June 2014
Resolved
The door handle on the A class boundary door for the stairway in the main deck in accommodation space is missing and is being propped open. Fix door handle and remove door hold prop. 46CFR92.07-10(d).
Action required: 705 - Other - as specified
Due 5 July 2014
Resolved 2 July 2014
Resolution: Received email with pictures from rig illustrating that new door handles have been installed on the main deck accommodation fire door satisfying the outstanding requirement.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 5 June 2014
Resolved
Several electrical boxes are missing a directory. Update all electircal boxes on the rig with proper directory to include circuit and amp ratings. 46CFR111.40-11.
Action required: 705 - Other - as specified
Due 5 July 2014
Resolved 18 June 2014
Resolution: Received email photos from rig showing the panel boxes have been updated properly.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 5 June 2014
Resolved
SOPEP revisions have not been maintained and is therefore out of date. Ensure all revisions are up to date in the SOPEP MARPOL Annex I/38.
Action required: 705 - Other - as specified
Due 5 July 2014
Resolved 27 June 2014
Resolution: Received email from rig with updates and revisions to the SOPEP attached satisfying the outstanding requirement.
Fire Fighting › Fixed Halon Fire Extinguishing System › Piping
Issued 5 June 2014
Resolved
The rig's HALON fixed firefighting system had a loose connection on a bottle for the SCR. Connection was tightened during inspection. 46CFR107.235(b).
Action required: 705 - Other - as specified
Due 5 June 2014
Resolved 5 June 2014
Resolution: Connection was tightened during inspection.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 28 December 2010
Resolved
Ensure all dryer exhaust hoses are of metalic type.
Action required: 705 - Other - as specified
Resolved 2 January 2011
Lifesaving › Lifeboat Equipment › Anti-seasickness Medicine
Issued 28 December 2010
Resolved
Ensure sufficient quantity of sea sick pills with current date for all lifeboats.
Action required: 705 - Other - as specified
Resolved 2 January 2011
Lifesaving › Lifebuoys › Size
Issued 28 December 2010
Resolved
Replace throwable buoys at quick release boxes at lifeboats with approved bridge buoys for quick release use.
Action required: 705 - Other - as specified
Resolved 2 January 2011
Construction/Loadline › Hull › Hull Plating
Issued 15 January 2009
Resolved
Complete SEILOD Phase II within 90 days or prior to the next rig move.
Action required: 705 - Other - as specified
Due 15 July 2009
Resolved 12 July 2009
Resolution: Reviewed Class Society (American Bureau of Shipping) Survey Report detailing completed Dry-docking Survey - UWILD satisfying the vessels required Phase II SEILODD examination.
Communications › Public Address System › Loudspeaker
Issued 23 January 2007
Resolved
Remove "on/off" switch for PA speaker in recreation room.
Action required: 705 - Other - as specified
Due 23 January 2007
Resolved 24 January 2007
Resolution: Verified that switch was removed.
Accommodation/Occupational Safety › Ventilation › General
Issued 23 January 2007
Resolved
Demonstrate proper operation of loss of mud pit ventilation alarm at drill floor.
Action required: 705 - Other - as specified
Due 23 January 2007
Resolved 23 January 2007
Resolution: Demonstrated alarm prior to departing unit this date.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 January 2007
Resolved
Demonstrate proper operation of all obstruction lights.
Action required: 705 - Other - as specified
Due 23 January 2007
Resolved 24 January 2007
Resolution: Demonstrated satisfactory operation of all lights this date.
Deck/Cargo › Cargo Stowage › General
Issued 23 January 2007
Resolved
Complete UT inspection of all P-tanks as follows: Tank #1 - 19 shots, Tank #2 - 13 shots, Tank #3 - 12 shots, Tank #4 - 16 shots - all as marked by USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 23 January 2007
Resolved 30 January 2007
Resolution: Received Atlantic Marine UT inspection report number 2252.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 23 January 2007
Resolved
Complete UT inspection IWO bottom drain - inboard ship's air receiver and clean interior to make available for internal inspection.
Action required: 705 - Other - as specified
Due 23 January 2007
Resolved 30 January 2007
Resolution: Internal inspection conducted 1/24/07. UT report # 2252-002 received 1/30/2007.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 January 2007
Resolved
Demonstrate proper operation of starboard bilge alarm & indication in OIM office.
Action required: 705 - Other - as specified
Due 23 January 2007
Resolved 24 January 2007
Resolution: Bilge alarm indication demonstrated satisfactorily this date. OIM stated that alarm panel had been wired wrong during 2006 dry-docking.
Construction/Loadline › Structures › Machinery Space Opening
Issued 23 January 2007
Resolved
Replace all missing port light covers for mud pit (4) and forward deckhouse bulkhead door.
Action required: 705 - Other - as specified
Due 23 January 2007
Resolved 26 January 2007
Resolution: New port light covers installed this date.
Engineering › Lubricating Oil Storage/Transfer System › Gauge
Issued 23 January 2007
Resolved
Renew lube oil tank sight glass on aft lube oil tank with flame resistant glass.
Action required: 705 - Other - as specified
Due 23 January 2007
Resolved 24 January 2007
Resolution: Verified that sight glass was replaced this date.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 23 January 2007
Resolved
Renew cracked fuel hose on emergency generator.
Action required: 705 - Other - as specified
Due 23 January 2007
Resolved 24 January 2007
Resolution: Verified that fuel hose had been renewed this date.
Construction/Loadline › Structures › Machinery Space Opening
Issued 23 January 2007
Resolved
Provide alarm system for internal openings/watertight doors to signal both locally and at the normally manned control station whether the appliances are open or closed IAW 46 CFR 108.114(c)(ii).
Action required: 705 - Other - as specified
Due 1 March 2007
Resolved 15 January 2008
Documentation › Safety Management System › Designated Person(s) Documentation
Issued 23 January 2007
Resolved
Provide copies of welder qualification credentials for welders completing spud can enhancement work.
Action required: 705 - Other - as specified
Due 23 January 2007
Resolved 30 January 2007
Resolution: Received documentation from AMI Shipyard.
Construction/Loadline › Hull › Weld
Issued 23 January 2007
Resolved
Provide copies of NDT reports for work inspected on spud can enhancements.
Action required: 705 - Other - as specified
Due 23 January 2007
Resolved 30 January 2007
Resolution: Received AMI NDT report # MT.2252-01 through # MT.2252-06 this date.
Operations/Management › Drills/Instruction › Fire
Issued 23 January 2007
Resolved
Complete fire and abandon ship drills once all safety & firefighting equipment is returned to stations.
Action required: 705 - Other - as specified
Due 23 January 2007
Resolved 24 January 2007
Resolution: Witnessed satisfactory fire & abandon ship drills this date.
Deck/Cargo › Cargo Stowage › General
Issued 23 January 2007
Resolved
AMI UT inspection rpt of 1/30/07 revealed minimum thickness readings below that prescribed by mfg data rpts in some areas on P-tanks 18064-18067. These must remain OOS until one of the following are completed. 1. Renew all P-tanks; or 2. Provide written repair plan to OCMI for review & approval; or 3. Provide evidence that p-tanks currently meet 46 CFR Sub F & ASME VIII.
Action required: 705 - Other - as specified
Due 1 March 2007
Resolved 15 January 2008
Resolution: All 4 P-tanks, cert repair & cert for service iaw ASME VIII, NBIC, signature [name withheld], API 510 cert #27308, NB #11527AB.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 23 January 2007
Resolved
Provide U1A Manufacturer Data Report for main air receiver inboard to show corrosion allowance for this pressure vessel.
Action required: 705 - Other - as specified
Due 1 March 2007
Resolved 15 January 2008
Resolution: Air rcvr in question replaced, U1A provided.
Construction/Loadline › Hull › Hull Plating
Issued 8 February 2006
Resolved
Complete SEILOD Phase II during next rig move. Advise local OCMI when the move date is known.
Due 31 March 2006
Resolved 1 April 2006
Resolution: SEILOD completed.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 19 January 2006
Resolved
Provide hydro-static release on #3 float free life raft. Leave life raft unstrapped until release is provided.
Due 19 February 2006
Resolved 8 February 2006
Lifesaving › Launching Appliances › Davit
Issued 19 January 2006
Resolved
Provide 100% float free life raft arrangement.
Due 19 February 2006
Resolved 27 February 2006
Lifesaving › Lifeboat
Issued 16 March 2004
Resolved
Prove proper operation of #3 lifeboat engine.
Due 8 April 2004
Resolved 5 April 2004
Resolution: Cleared by fax on 05APR04. Alternator cable replaced and engine test run.
Lifesaving › Lifeboat
Issued 16 March 2004
Resolved
Prove compentency to launch & recover lifeboats.
Due 8 April 2004
Resolved 5 April 2004
Resolution: Cleared by fax on 05APR04. Proper launching 30MAR04.
Operations/Management › Drills/Instruction
Issued 16 March 2004
Resolved
Ensure at least 1 boat is lowered alternatively at each abandon drill. 46 CFR 109.213(d) post '96 edition.
Due 16 April 2004
Resolved 5 April 2004
Resolution: Cleared by fax on 05APR04. #2 boat launched and sprinkler system checked 30MAR04.
Electrical
Issued 16 March 2004
Resolved
Move purge alarm for TOTCO unit so that it is visible to driller.
Due 8 April 2004
Resolved 5 April 2004
Resolution: Cleared by fax on 05APR04. Purge alarm moved to a visible location.
Construction/Loadline › Hull › Bottom Plating
Issued 29 January 2004
Resolved
COMPLETE PHASE II OF SEILOD EXAM LEG TO SPUD CAN UNDERWATER SWIMBY DURING NEXT RIG MOVE NO LATER THAN 28APRIL2004.
Condition: Unknown
Due 28 April 2004
Resolved 27 April 2004
Resolution: PHASE II COMPLETED.
Fire Fighting › Nozzles
Issued 5 February 2002
Resolved
Make proper repairs to fire nozzles at Fire Stations 19, 21, and 22. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2002
Resolved 11 March 2002
Resolution: Examined all three nozzles and found operating properly.
Electrical › Electric Generation Source (emergency)
Issued 5 February 2002
Resolved
Properly label breakers in emergency generator room in emergency light panel IAW 46CFR111.40.11. LEGACY COMPONENT DESC: Panelboard
Action required: 705 - Other - as specified
Due 29 April 2002
Resolved 11 March 2002
Resolution: Examined breaker panel and found labels properly.
Electrical › Electric Supply System (service)
Issued 5 February 2002
Resolved
Properly remove all dead end wires in mud pit room. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 29 April 2002
Resolved 11 March 2002
Resolution: Examined mud pit room and found all dead end wires removed.
Electrical › Electric Supply System (service)
Issued 5 February 2002
Resolved
Replace damaged armored cable in shaker house fort the H2S alarm. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2002
Resolved 11 March 2002
Resolution: Examined cable for H2S alarm and found replaced.
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System
Issued 5 February 2002
Resolved
Submit plans for, or remove temporarily installed deluge foam fire fighting system located in shaker house.
Action required: 705 - Other - as specified
Due 29 April 2002
Resolved 11 March 2002
Resolution: Found temporary foam deluge system removed from shaker house.
Engineering › Pressure Vessel
Issued 5 February 2002
Resolved
Make dry bulk tanks available for internal examination IAW 46CFR61.10-5.
Action required: 705 - Other - as specified
Due 29 April 2002
Resolved 11 March 2002
Resolution: Internally examined four dry bulk tanks and found satisfactory.
Engineering › Bilge Water Management System
Issued 5 February 2002
Resolved
Properly label bilge system valves for port and starboard bilge systems. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2002
Resolved 11 March 2002
Resolution: Examined bilge system and found properly labeled.
Pollution Prevention/Response › Prevention Equipment
Issued 5 February 2002
Resolved
Make temporary repairs to leak in Red Fox MSD. Provide proposal to attending inspector as to how repair is to be made. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2002
Resolved 11 March 2002
Resolution: Examined repair procedures provided by Red Fox and repairs to the unit and found satisfactory.
Lifesaving › Lifebuoys
Issued 5 February 2002
Resolved
Restencil name and homeport on lifebuoys as necessary throughout vessel. LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2002
Resolved 11 March 2002
Resolution: Examined lifebuoys and found restenciled.
Lifesaving › Lifeboat
Issued 5 February 2002
Resolved
Prove limit switch on lifeboat number 3 once transformer is repaired.
Action required: 705 - Other - as specified
Due 29 April 2002
Resolved 11 March 2002
Resolution: Witnessed operation of limit switch after transformer was repaired.
Lifesaving › Lifeboat
Issued 5 February 2002
Resolved
Prove limit switch on lifeboat number 3 once transformer is repaired.
Action required: 705 - Other - as specified
Due 29 April 2002
Resolved 11 March 2002
Resolution: Witnessed operation of limit switch after transformer was repaired.
Electrical
Issued 5 February 2002
Resolved
Properly repack all cable transits as necessary in mud pit room bulkheads.
Action required: 705 - Other - as specified
Due 29 April 2002
Resolved 11 March 2002
Resolution: Examined all cable transits in mud pit room and found properly packed.
Electrical
Issued 5 February 2002
Resolved
Provide information for AC unit in mud engineers shack as to approval for use in hazardous location and location of unit in relation to shaker house.
Action required: 705 - Other - as specified
Due 29 April 2002
Resolved 11 March 2002
Resolution: Offshore [name withheld] stated that the AC unit was fourteen feet above the shaker house, but installed a unit that was approved for use in a hazardous location. Examined unit and verified the same.
Construction/Loadline
Issued 14 March 2001
Resolved
MAKE LEGS/CANS AVAILABLE TO FOR COMPLETION OF PHASE II OF SEILOD.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Fire Fighting
Issued 31 March 2000
Resolved
SUBMIT FIRE CONTROL AND SAFETY PLAN THAT SHOWS THE STRUCTURAL FIRE PROTECTION AS ON BOARD RIG.
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Lifesaving
Issued 31 March 2000
Resolved
COMPLY WITH ALL THE TRAINING AND LOGGING REQUIREMENTS IN ACCORDANCE WITH 46CFR109.213.
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Lifesaving
Issued 31 March 2000
Resolved
RENEW PORT AND STBD VIEWING PORTS FROM OPERATOR'S STATION #3 LIFEBOAT. REPAIR STEERING ON LIFEBOAT #2.
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Fire Fighting
Issued 31 March 2000
Resolved
ENSURE THAT ALL STAIR TOWER FIRE DOORS ARE SELF CLOSING AND LATCHING. REPLACE ALL NON UL 19 APPROVED FIRE HOSES WITH APPROVED FIRE HOSES.
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Fire Fighting
Issued 9 February 1998
Resolved
PROVE PROPER OPERATION OF GENERAL ALARM BELL ON AFT RIG FLOOR.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Construction/Loadline
Issued 9 February 1998
Resolved
PROVIDE 100% BILGE SUCTION AT ROSE BOXES UTILIZING BOTH BILGE PUMPS. ENSURE STRAINERS/ROSE BOXES CLEAN, FREE FROM DEBRIS. OVERHAUL BILGE VALVESAS NECESSARY.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Fire Fighting
Issued 9 February 1998
Resolved
CONDUCT FIRE/ABANDON RIG DRILLS.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Electrical
Issued 9 February 1998
Resolved
PROVE PROPER OPERATION OF TOTCO VIDEO SYSTEM LOSS OF PURGE INDICATION.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Electrical
Issued 9 February 1998
Resolved
PROPERLY MOUNT TOP DRIVE MONITOR CABLE IN ACCORDANCE WITH APPLICABLE ELECTRICAL INSTALLATION REQUIREMENTS.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Electrical
Issued 9 February 1998
Resolved
PROPERLY INSTALL TOTCO GAS TRAP IN SHAKER HOUSE.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Fire Fighting
Issued 4 February 1997
Resolved
CONDUCT FIRE AND BOAT DRILLS.
Condition: Unknown
Due 4 March 1997
Resolved 20 February 1997
Lifesaving
Issued 4 February 1997
Resolved
CONDUCT TEST OF TOTAL RIG SHUTDOWN AT NEXT RIG MOVE OR BY 04 MAR 97.
Condition: Unknown
Due 4 March 1997
Resolved 20 February 1997
Lifesaving
Issued 4 February 1997
Resolved
CONDUCT TEST OF GENERAL ALARMS AT NEXT RIG MOVE OR BY 04 MAR 97.
Condition: Unknown
Due 4 March 1997
Resolved 20 February 1997
Engineering
Issued 4 February 1997
Resolved
REPAIR LUBE OIL SHUTDOWN FOR #3 GENERATOR AND RETEST PRIOR TO NEXT RIG MOVEOR BY 04 MAR 97.
Condition: Unknown
Due 4 March 1997
Resolved 20 February 1997
Unknown
Issued 4 February 1997
Resolved
PROVIDE PURGE ALARM FOR UPS PUMP STROKE COUNTER AT NEXT RIG MOVE OR BY 04_x001C_ MAR 97.
Condition: Unknown
Due 4 March 1997
Resolved 20 February 1997
Accommodation/Occupational Safety
Issued 4 February 1997
Resolved
OPEN FOR INSPECTION DECK AIR RECEIVERS/PORTABLE TANKS AND TEST RELIEF VALVES PRIOR TO NEST RIG MOVE OR BY 04 MAR 97.
Condition: Unknown
Due 4 March 1997
Resolved 20 February 1997
Lifesaving
Issued 13 February 1996
Resolved
CONDUCTED WEIGHT TEST OF ALL THREE LIFEBOAT AND ONE LIFERAFT DAVIT CABLES AS ALL WERE RENEWED AFTER COI DATE.
Condition: Unknown
Due 13 February 1996
Resolved 13 February 1996
Construction/Loadline
Issued 4 February 1994
Resolved
COMPLETE UPPER HULL EXAM AS PER ENSCO LETTER DATED 01FEB94.
Condition: Unknown
Due 4 February 1994
Resolved 4 February 1994
Electrical
Issued 12 February 1993
Resolved
PROVIDE EMERGENCY GENERATOR DATA PLATE.
Condition: Unknown
Due 12 February 1993
Resolved 12 February 1993
Navigation
Issued 12 February 1993
Resolved
PROVIDE LEAD LINING IN OBSTRUCTION LIGHT BATTERY BOX.
Condition: Unknown
Due 12 February 1993
Resolved 12 February 1993
Electrical
Issued 12 February 1993
Resolved
REPLACE DAMAGED LIGHT LENS ABOVE #3 GENERATOR.
Condition: Unknown
Due 12 February 1993
Resolved 12 February 1993
Unknown
Issued 12 February 1993
Resolved
PROVIDE 150 RELIEF VALVE FOR DRILL FLOOR AIR RECEIVER,
Condition: Unknown
Due 12 February 1993
Resolved 12 February 1993
Lifesaving
Issued 12 February 1993
Resolved
CONDUCT WEIGHT TEST OF DAVIT, FOR DAVIT LAUNCH INFLATEABLE LIFERAFT.
Condition: Unknown
Due 12 February 1993
Resolved 12 February 1993
Fire Fighting
Issued 5 July 1991
Resolved
CONDUCT SATISFACTORY OPERATIONAL TEST OF -3- FIRE MONITORS ON DECK._x001C_
Condition: Unknown
Due 5 July 1991
Resolved 5 July 1991
Fire Fighting
Issued 15 February 1991
Resolved
PROVIDE THREE COPIES OF A FIRE CONTROL PLAN FOR REVIEW AND APPROVAL TO MSO MOBILE.
Condition: Unknown
Due 15 February 1991
Resolved 15 February 1991
Documentation
Issued 15 February 1991
Resolved
REVISE OPERATIONS MANUAL TO INCLUDE NEWLY INSTALLED RED FOX SANITATION UNITAND INTERMEDIATE GUIDES.
Condition: Unknown
Due 15 February 1991
Resolved 15 February 1991
Fire Fighting
Issued 29 May 1990
Resolved
HARDPIPE DISCHARGE SIDE OF BOTH FIRE PUMPS OR INSTALL SHOCK MOUNTS FOR PUMP
Condition: Unknown
Due 29 May 1990
Resolved 29 May 1990
Electrical
Issued 29 May 1990
Resolved
TEST ALL REMOTE SHUTDOWNS IN PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 29 May 1990
Resolved 29 May 1990
Electrical
Issued 29 May 1990
Resolved
TEST ALL REVERSE POWER RELAYS IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 29 May 1990
Resolved 29 May 1990
Accommodation/Occupational Safety
Issued 29 May 1990
Resolved
REPAIR MUDPIT VENTILATION SHUTDOWN TO OPERATE FROM REMOTE LOCATION.
Condition: Unknown
Due 29 May 1990
Resolved 29 May 1990
Electrical
Issued 29 May 1990
Resolved
LOCATE AND REPAIR GROUND ON 120/208 V MAIN LIGHTING DISTRIBUTION PANEL.
Condition: Unknown
Due 29 May 1990
Resolved 29 May 1990
Electrical
Issued 29 May 1990
Resolved
PROPERLY HANG WIRES IN MUD PIT ROOM USING PROPER STRAPS AND NOT PLASTIC TIEWRAPS.
Condition: Unknown
Due 29 May 1990
Resolved 29 May 1990
Unknown
Issued 26 April 1989
Resolved
REPLACE NON EXPLOSIVE PROOF FITTINGS IN MUD PIT ROOM.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Unknown
Issued 26 April 1989
Resolved
PROVIDE NEW LEADLINE FOR EMERGENCY GENERATOR BATTERIES.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Unknown
Issued 26 April 1989
Resolved
REPLACE FOGHORN BATTERIES.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Unknown
Issued 26 April 1989
Resolved
PROVE OPERATION OF GENERAL ALARM LIGHT ON DRILL FLOOR.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Fire Fighting
Issued 6 April 1989
Resolved
HAVE THE NEWLY INSTALLED AFFF SYSTEM FOR THE HELICOPTERS LANING AREA INSPECTED BY A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Electrical
Issued 8 June 1988
Resolved
PROVIDE A SUITABLE ENCLOSURE FOR THE MUD PUMP STROKE SELECTOR LOCATED ON THE DRILL FLOOR, PER 46 CFR 111.105-5.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Engineering
Issued 8 June 1988
Resolved
PROVIDE A RELIEF VALVE ON THE LOW PRESSURE SIDE OF THE REDUCING STATION FORTHE BULK TANK AIR SUPPLY. THE RELIEF VALVE SHALL BE SET AT NOT MORE THAN 20% OVER THE MAWP OF THE BULK TANK. PER 46 CFR 56.50-10
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Electrical
Issued 8 June 1988
Resolved
REMOVE ALL TYPE SO ELECTRICAL CABLES FROM THE DRILL FLOOR AND ALL CABLES THAT CAN NOT BE IDENTIFIED PER 46 CFR 111.105-17.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Accommodation/Occupational Safety
Issued 8 June 1988
Resolved
REMOVE ALL TEMPORARY WALKWAYS UTILIZED FOR ACCESS AND DEGREES FROM THE RIG.(REF. 33 CFR 143.110(C))
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Lifesaving
Issued 1 June 1988
Resolved
REPLACE ALL (8) EIGHT RING BOUYS, THE POLYPROPLENE LINE IS DETERIORATED.
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Fire Fighting
Issued 1 June 1988
Resolved
LOCATE AND PROVIDE ON STATION, AS INDICATED ON FIRE CONTROL AND LIFESAVING PLAN, ALL PORTABLE FIRE EXTINGUISHERS. REPLACE OR SERVICE FIRE EXTINGUISHERS #30/#45.
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Lifesaving
Issued 1 June 1988
Resolved
CHANGE FUEL IN PORT AND STARBOARD LIFEBOATS.
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Documentation
Issued 1 June 1988
Resolved
PROVIDE A CURRENT STICKER FOR THE CERTIFICATE OF DOCUMENTATION (EXPIRED ON 31APR88).
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Lifesaving
Issued 1 June 1988
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Lifesaving
Issued 1 June 1988
Resolved
MAKE OPEATIONAL BRAKE, REPLACE ON #1 LIFERAFT. CABLE IS FROZEN WITHIN DAVIT. REATTACH FAIRLEAD.
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Lifesaving
Issued 1 June 1988
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Lifesaving
Issued 1 June 1988
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Electrical
Issued 6 May 1987
Resolved
PROPERLY MOUNT ELECTRICAL JUNCTION BOX ON BULKHEAD IN HALIBURTON SPACE LOCATED NEXT TO BILGE PUMP ON/OFF CONTACT MAKER. 46 CFR 111.81
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Deck/Cargo
Issued 6 May 1987
Resolved
REPLACE AIR HOSE WITH APPROVED FUEL HOSE FOR FORK LIFT FUELING HOSE. 46 CFR 109.537
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Electrical
Issued 6 May 1987
Resolved
PROPERLY MOUNT ELECTRICAL JUNCTION BOX LOCATED IN MUD PUMP ROOM BENEATH PHONE BOOTH.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Fire Fighting
Issued 6 May 1987
Resolved
REPLACE PRESSURE RELIEF VALVE ON FIRE PUMP #2. RELIEF VALVE SET AT 100 PSIAND WILL NOT RELIEVE AT 120 PSI. 120 PSI GREATER THAN 10% OF RELIEF VALVE SETTING. 46 CFR 108.417 (A)
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Electrical
Issued 6 May 1987
Resolved
PROPERLY MOUNT JUNCTION BOX LOCATED ON THE MAIN DECK, AFTER BLKHD OF THE MAIN HOUSE ADJACENT TO FIRESTA #31. 46 CFR 111.81
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Construction/Loadline
Issued 6 May 1987
Resolved
LABEL ALL BILGE VALVES LOCATED IN THE PORT AND STBD BILGE PITS TO INDICATE WHAT PUMPS AND PRELOADS THE VALVES SERVE. 33 CFR 155
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Accommodation/Occupational Safety
Issued 6 May 1987
Resolved
PROVIDE RELIEF VALVES ON THE SANITARY WATER TANK SET AT OR BELOW 100 PSI OR MAKE AVAILABLE FOR INTERNAL INSPECTION PER 46 CFR 54.01.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Fire Fighting
Issued 6 May 1987
Resolved
PROVIDE PRESSURE GAUGE ON FIRE PUMP #1. 46 CFR 108.417 (B)
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Electrical
Issued 6 May 1987
Resolved
PROPERLY SECURE HEAVY ELECTRICAL CABLE ON THE FWD BLKHD OF THE SHALE SHAKER. THE PRESENT TIES ARE TOO SMALL. 46 CFR 111.105
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Electrical
Issued 6 May 1987
Resolved
PROPERLY SECURE (MOUNT) JUNCTION BOX LOCATED IN SHALE SHAKER AREA BETWEEN (AND OVER) THE SHAKERS.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Electrical
Issued 6 May 1987
Resolved
REPLACE MISSING BOLTS IN THE EXPLOSION PROOF JUNCTION BOXES (2) IN THE SHALE SHAKER AREA. 46 CFR 111.105
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Electrical
Issued 6 May 1987
Resolved
PROPERLY MARK EMERGENCY FUEL SHUT-OFF VALVE FOR EMERGENCY GENERATOR. 46 CFR 56.50-75
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Construction/Loadline
Issued 6 May 1987
Resolved
BOTH DOORS TO THE MUD PITS ARE TO BE SELF-CLOSING GAS TIGHT. THIS MAY REQUIRE REPLACEMENT OF THE PRESENTLY INSTALLED WATER TIGHT DOORS TO BE COMPLETED WITHIN 30 DAYS AND PRIOR TO DRILLING OPERATIONS. 46 CFR 108.175
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Construction/Loadline
Issued 6 May 1987
Resolved
MAKE RELIABLY OPERABLE THE LOSS OF VENTILATION ALARM FOR THE MUD PITS. ALARM IS ARBITRARILY SOUNDS EVEN WHEN VENTILATION SYSTEM IS ON. TO BE COMPLETED WITHIN 30 DAYS AND PRIOR TO DRILLING OPERATIONS.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Electrical
Issued 6 May 1987
Resolved
MAKE OPERABLE THE LOW LUBE OIL ALARM AND ENGINE SHUDOWN FOR THE EMERGENCY GENERATOR. 46 CFR 112.50 AND 46 CFR 111.12-1
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Electrical
Issued 6 May 1987
Resolved
MAKE OPERABLE THE HIGH JACKET WATER ALARM AND THE LOW LUBE OIL ALARMS AND ENGINE SHUTDOWN ON THE NO.3 EMD ENGINE/GENERATOR SET.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Electrical
Issued 6 May 1987
Resolved
MAKE OPERABLE THE REVERSE POWER INDICATOR LIGHTS ON NO. 1,2, AND 3 EMD'S.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Lifesaving
Issued 6 May 1987
Resolved
REPAIR OR REPLACE THE BROKEN FLOOR BOARDS IN THE STARBOARD CAPSULE. 46 CFR 108.503
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Construction/Loadline
Issued 6 May 1987
Resolved
REPAIR ALL FLAME SCREENS ON ALL FUEL OIL TANK VENTS. THE MOUNTING FRAME FOR THE SCREENS HAS PULLED AWAY FORM THE MATING SURFACE.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Deck/Cargo
Issued 6 May 1987
Resolved
MAKE OPERABLE ALL REMOTE CRANE OPERATION INDICATOR FOR ALL CRANES.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Lifesaving
Issued 6 May 1987
Resolved
PROVIDE IN BOTH CAPSULES A MANUAL CONTAINING INFORMATION ON THE DIESEL ENGINE MAINTENENCE, OPERATION AND REPAIR.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Fire Fighting
Issued 6 May 1987
Resolved
PROVIDE ONBOARD THE REQUIRED SPARES FOR THE PORTABLE FIRE EXTINGUISHERS PER46 CFR 108.495 (B).
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Lifesaving
Issued 6 May 1987
Resolved
PROPERLY MOUNT THE COMPASS FOR BOTH CAPSULES. THE HEADING INDICATOR IS ALIGNED 90 DEGREES TO STARBOARD.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Documentation
Issued 6 May 1987
Resolved
PROVIDE DOCUMENTATION THAT FUEL OIL TRANSFER HOSE MEETS REQUIREMENTS OF 33 CFR 155.800 (600 PSI BURST PRESSURE)
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Deck/Cargo
Issued 6 May 1987
Resolved
REPAIR LEAKING AIR RECEIVER ISOLATION VALVE FOR RIG AIR RECEIVER LOCATOR IN CORNER OF SPACE. 46 CFR 61.10-5
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Electrical
Issued 6 May 1987
Resolved
PROPERLY INSTALL OR REMOVE GRAY COMMUNICATION (?) CABLE LOCATED BEHIND DRILLERS CONSOLE. 46 CFR 111.60
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Lifesaving
Issued 6 May 1987
Resolved
CLEAN OR REPLACE HATCH GLASS ON NO. 1 & 2 CAPSULES. 46 CFR 108.506
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Documentation
Issued 6 May 1987
Resolved
PROVIDE ON BOARD THE VCESSEL THE APPROVAL LTR FOR THE HAZARDOUS LOCATION PLAN- MSO CORPUS CHRISTI DTD 30APR85. 46 CFR 110.25-1(K)
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Electrical
Issued 6 May 1987
Resolved
REPAIR GENERAL ALARM BELLS ON MAIN DECK; (1) ON BOW AND (1) ON EACH CORNER OF ACCOMMODATION HOUSE AFT BULKHEAD. TOTAL OF (3) BELLS NOT WORKING PROPERLY. 46 CFR 113.25
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Electrical
Issued 6 May 1987
Resolved
REMOVE THE DEAD END ELECTRICAL CABLE LOCATED BACK OF DRILLERS CONSOLE. 46 CFR 111.60
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Engineering
Issued 21 May 1986
Resolved
TEST ALL THREE AIR RECEIVERS RELIEF VALVES IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 21 May 1986
Resolved 21 May 1986
Lifesaving
Issued 6 May 1985
Resolved
INSTALL ONE DAVIT LAUNCHED LIFERAFT AS SOON AS IT ARRIVES FROM VENDER.
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985