Inspection history · 21
4 December 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8277717
5 February 2025
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8084591
28 August 2024
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7990992
28 August 2024
Type not recorded
No type recorded · Station San Diego · USCG Southwest District (CGD-SW) · Activity 7992011
10 October 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7806273
16 February 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7637628
21 September 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7563960
29 November 2021
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7358785
13 October 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7331742
15 October 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7077662
20 November 2019
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6858732
17 July 2019
Initial Certification · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6753630
1 June 2019
Type not recorded
No type recorded · Station San Diego · USCG Southwest District (CGD-SW) · Activity 6702636
30 September 2018
Uninspected Other
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6553283
2 September 2018
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6535160
1 July 2018
Type not recorded
No type recorded · Station San Diego · USCG Southwest District (CGD-SW) · Activity 6463685
15 November 2017
Inclining Experiment · Deadweight Survey · Hull Examination · Plan Review "T" Boat · Construction Oversight · Examination of Repairs · DAPI Audit · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6306195
14 October 2017
Type not recorded
No type recorded · Station San Diego · USCG Southwest District (CGD-SW) · Activity 6288393
23 July 2017
Type not recorded
No type recorded · Station San Diego · USCG Southwest District (CGD-SW) · Activity 6218829
16 April 2017
Type not recorded
No type recorded · Station San Diego · USCG Southwest District (CGD-SW) · Activity 6128392
23 June 2016
Type not recorded
No type recorded · Station San Diego · USCG Southwest District (CGD-SW) · Activity 5917277
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 August 2024
Resolved
Vessel's COI expired 17JUL2024 and is to complete a COI prior to getting U/W.
46 CFR 176.107
17c-Rectify deficiencies prior to departure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2024
Resolution: COI inspection completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. MI found several items in the first aid kit expired. Replace first aid kit and notify local OCMI to clear deficiency.
46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2024
Resolved 31 October 2024
Resolution: New first aid kit provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found at upper helm and laz. Remove 08 dead end wires on upper helm and 02 in laz.
46 CFR 183.200 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2024
Resolved 31 October 2024
Resolution: Dead end wires removed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 28 August 2024
Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. The starboard outermost cable penetration on the aft engine room bulkhead has a penetration that is not vapor tight. Provide a proper seal to prevent the passage of vapors.
46 CFR 177.405
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2024
Resolved 31 October 2024
Resolution: Seal provided to prevent passage of vapors.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 28 August 2024
Resolved
A complete application for an original MMC must contain proof, documented on CG-719-K or CG-719-K/E, as appropriate, that the applicant passed all applicable vision, hearing, medical, and/or physical exams as required by subpart C of this part or a valid medical certificate issued by the Coast Guard. The Master did not have his medical certificate available. Provide master with valid medical certificate.
46 CFR 10.302(a)
Action required: 705 - Other - as specified
Resolved 31 October 2024
Resolution: Medical certificate provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 28 August 2024
Resolved
Each ship transporting more that six passengers for hire equipped with a radiotelephone station must carry a radio operator who: holds a marine radio operator permit (MROP) or higher class license. Master onboard did not have a valid radio operator permit. Provide master with valid MROP.
47 CFR 80.158 (e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2024
Resolved 22 January 2025
Resolution: MROP provided for captain.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 August 2024
Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. The initial inspection may include an inspection of the following items: Certificates and operating manuals, including certificates issued by the FCC. FCC Safety Radio Certificate not issued by FCC licensed technicianfor radio installation. Provide inspection and valid FCC Safety Radio Certificate.
46 CFR 176.402
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2024
Resolved 31 October 2024
Resolution: FCC safety readio certificate provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 October 2023
Resolved
A vessel must have one or more ring life buoys as follows: A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached Ring buoy lifeline was dry rotted and broke upon inspection. Fix lifeline or replace with new.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 October 2023
Resolved 12 October 2023
Resolution: Vessel supplied new evidence of lifebuoy with new lifelines.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 October 2023
Resolved
Accommodation spaces of vessels must be equipped with a fire detection system. Smoke detector in accommodation spaces were missing or failed to operate. Replace smoke detectors in accommodations spaces.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 October 2023
Resolved 13 October 2023
Resolution: Tested all new smoke detectors, test sat
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 10 October 2023
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length, a battery powered bullhorn may serve as the public address system if audible throughout the accommodation spaces of the vessel during normal operating conditions. The bullhorn's batteries are to be continually maintained at a fully charged level by use of a battery charger or other means acceptable to the cognizant OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2023
Resolved 13 October 2023
Resolution: Tested bullhorn, all sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 October 2023
Resolved
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Found several rugs, pillows and other material in aft accommodation space that were not fire retardant. Remove all non-fire retardant material from the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2023
Resolved 13 October 2023
Resolution: Verified all rugs, pillows and other material in aft accommodation space that were not fire retardant material were removed from space.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 10 October 2023
Resolved
Vessel operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of 47CFR80.1101(c)(2). Observed testing VHF-DSC radio and resulted with no GPS coordinates. Vessel is to replace the radio to meet the requirements listed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2023
Resolved 12 October 2023
Resolution: Vessel supplied evidence of the radio and GPS working.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 October 2023
Resolved
Where passing through bulkheads, fuel lines must be protected by close fitting ferrules or stuffing boxes. All fuel lines and fittings must be accessible for inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2023
Resolved 13 October 2023
Resolution: Determined that bulkhead with J-1942 hose passage is not watertight and metallic fittings are not required.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 September 2022
Resolved
Abandoned Ship, Man Overboard and Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Drill logs not available for inspection. Upon successful completion of drills during inspection, vessel master informed to log all drills to make available for inspection.
Action required: 10 - Deficiency Rectified
Due 21 September 2022
Resolved 21 September 2022
Resolution: Corrected on the spot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 October 2021
Resolved
Remove oil soaked sleeves around flexible non-metallic hoses supplying lubricating oil to turbos. Replace sleeves if required by hose manufacturer. 182.720(e).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 30 November 2021
Resolution: All hoses replaced with type approved hoses
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 13 October 2021
Resolved
Cap open overboard in engine on stbd side. 179.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 30 November 2021
Resolution: Overboard capped -McFarland
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 13 October 2021
Resolved
Tighten and add second hose clamp at loose sewage overboard hose at thru-hull valve in lazzarette. 179.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 30 November 2021
Resolution: Hose properly clamped
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 October 2021
Resolved
Replace expired items in First Aid Kit 184.710.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 30 November 2021
Resolution: First Aid Kit replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2020
Resolved
FUEL HOSES ON MAIN ENGINES IMPROPERLY CONNECTED BYPASSING THE FUEL CHILLER. MUST PROPERLY CONNECT IN ACCORDANCE WITH MANUFACTURER GUIDANCE TO THE SATISFACTION OF THE CG MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2020
Resolved 15 October 2020
Resolution: Provided pics for proof...[name withheld]
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 October 2020
Resolved
MUST PROVIDE ANNUAL SERVICE TESTING REPORT OR TEST IN THE PRESENCE OF CG MARINE INSPECTOR OF ALL SMOKE DETECTORS IN ACCOMMODATION SPACES AND ENGINE SPACE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2020
Resolved 19 November 2020
Resolution: Report sent to office via email...[name withheld]
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 15 October 2020
Resolved
MUST PROVIDE BULLHORN TO MAKE GENERAL AND EMERGENCY ANNOUNCEMENTS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2020
Resolved 19 November 2020
Resolution: PIC sent to office via email...[name withheld]
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 October 2020
Resolved
MUST ATTACH LANYARDS TO ALL 2.5 GALLON FIRE BUCKETS
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2020
Resolved 19 November 2020
Resolution: PIC sent office via email...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 October 2020
Resolved
MUST PROPERLY SECURE ALL GAS CYLINDERS INCLUDING EXTRA FIRE EXTINGUISHERS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2020
Resolved 15 October 2020
Resolution: Wtinessed crew properly secure items..[name withheld]
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 July 2019
Resolved
Post COI and Stability Letter visible to passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2019
Resolved 28 August 2019
Resolution: Posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 July 2019
Resolved
Update posted emergency instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2019
Resolution: Corrected/posted.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 17 July 2019
Resolved
Provide FCC Marine Radio Operator's Permit for Master.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2019
Resolution: Received the new Captain's Marine Radio op permit and updated DAPI list.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 July 2019
Resolved
Remove couch from salon area. Replacement shall meet regulation 46CFR 116.423.
Action required: 15 - Rectify deficiencies by next port
Resolved 26 August 2019
Resolution: Couch removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 July 2019
Resolved
Provide specification sheet for mattress.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2019
Resolution: Received picture of mattress removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 July 2019
Resolved
Provide appropriate sized fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2019
Resolution: Received pics.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 17 July 2019
Resolved
Provide cover for switchboard in passenger space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2019
Resolution: corrected
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 July 2019
Resolved
Provide updated crew list from Drug/Alcohol Consortium.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2019
Resolution: Received updated list.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 July 2019
Resolved
Clean loose debris/stored items in aft storage space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2019
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 17 July 2019
Resolved
Properly mark the following:
Passenger limit on upper deck (8) & below deck (10)
No children access forward from doors
No passenger access forward while underway
No passenger access in aft storage area (master cabin)
Fire extinguishers inside cabinet on upper deck & fwd
Emergency fuel shut-offs
Emergency exit - Keep Clear
Life jacket storage areas w/ number & adult or child
Life jacket donning placards
Vessel name on all life jackets (childrens)
Vessel name on port and starboard area
CO2 protected space
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2019
Resolution: Received pics.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 July 2019
Resolved
Replace fuel hose on starboard generator and install clamps on fuel hoses.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2019
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 July 2019
Resolved
Install hose clamps on starboard MDE turbo lube oil drain hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2019
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 17 July 2019
Resolved
Install guards over port and starboard MDE pulley wheels.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 August 2019
Resolution: Received pictures.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 July 2019
Resolved
Repair escape hatch hold back mechanism on forward cabin escape hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 August 2019
Resolution: Received pictures.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 July 2019
Resolved
Mount fire extinguishers in flying bride and port side fwd cabin.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2019
Resolution: Mounted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 17 July 2019
Resolved
Repair cracked support for flying bridge on port side main deck aft.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2019
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 July 2019
Resolved
Install plugs on starboard MDE fuel filters.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2019
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 July 2019
Resolved
Correct dead-wires and open hose in transom.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2019
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 July 2019
Resolved
Provide device to shut down port generator prior to release of CO2 into protected space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2019
Resolution: Tested SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 July 2019
Resolved
Provide 3'-6' lanyard with corrosion resistant clip for life buoy floating light.
Action required: 705 - Other - as specified
Resolved 26 August 2019
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 17 July 2019
Resolved
Repair light for magnetic compass.
Action required: 705 - Other - as specified
Resolved 28 August 2019
Resolution: Received pic.