MAURY USCG vessel records Sign in
← All vessels

LADY ATHENA

LADY ATHENA is a passenger vessel (inspected). The Coast Guard has recorded 73 inspections since 1985, most recently in June 2025, along with 102 deficiencies — 4 with no resolution recorded — and 1 operational control, 1 with no removal date recorded.

Records from 1985 to 2025. Most recent: inspection, 11 June 2025.

Built
Not recorded
Last inspected
11 June 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WCP9557
249285
Flag
UNITED STATES
—
Maury page id
psix-249285

Inspections, by type

…with no type recorded2
Years with a record 38 calendar years (1985–2025)
The 73 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.0 ft × 12.5 ft × 4.1 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · UNITED STATES
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portMCCLELLANVILLE, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Net Ton
6 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 73

11 June 2025 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8156996
25 March 2025 Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8138886
12 June 2024 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7933976
8 February 2023 COI Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7634433
22 April 2022 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7436074
3 June 2021 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7201319
7 January 2021 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7134063
31 March 2020 Drydock Exam · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7120326
4 March 2020 COI Inspection · Administrative Inspection · Drydock Extension
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6915974
11 April 2019 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6659171
13 March 2018 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6368907
6 March 2018 Hull Examination · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6359340
17 February 2017 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6087733
23 January 2017 Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6076121
10 March 2016 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6076131
1 March 2016 Hull Examination · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5826095
10 March 2014 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 4813925
15 February 2012 Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 4244907
2 December 2010 Administrative Inspection · Simplified Stability Test
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3909408
2 December 2010 Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 3917858
11 March 2010 Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3694046
2 February 2010 Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3674609
13 January 2010 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3968723
29 April 2009 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3463920
27 February 2008 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3154611
13 February 2008 Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3147003
30 May 2007 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2946321
24 April 2007 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2915882
30 March 2006 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2612585
30 January 2006 Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2576151
10 March 2005 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2307239
15 April 2004 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2048244
20 February 2004 Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2010067
17 March 2003 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1758184
2 May 2002 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1611417
7 March 2002 Hull Examination · Internal Structural Exam
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1492768
17 April 2001 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1406915
27 March 2000 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1467202
7 March 2000 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1399285
13 April 1999 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1469893
7 April 1998 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1441362
4 March 1998 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1120607
18 April 1997 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1105143
11 April 1997 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1096527
3 May 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1083246
24 April 1996 Re-Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1085858
9 January 1996 Drydock Extension
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 880874
5 June 1995 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1184480
12 April 1995 Examination of Repairs
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1156988
12 July 1994 Examination of Repairs
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1176946
12 May 1994 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 859493
26 April 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1168756
19 April 1994 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 855712
8 February 1994 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 852701
13 December 1993 Examination of Repairs
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 849066
19 November 1993 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1146159
14 October 1993 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 835422
7 April 1993 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1431205
9 July 1992 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 943890
16 April 1992 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1270728
24 April 1991 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 930085
12 March 1991 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 918122
25 September 1990 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1215301
27 April 1990 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1235729
8 March 1990 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1230247
18 January 1990 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1228437
1 May 1989 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1195777
20 April 1989 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1043361
26 April 1988 Deficiency Check · COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1346033
21 October 1987 Re-Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1321911
24 April 1987 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1014377
2 April 1986 Credit Drydock
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1306313
27 April 1985 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 979237

Deficiency record · 102

01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 12 June 2024 Resolved
No vessel subject to inspection under 46 U.S.C. 3301 will be navigated unless it is under the direction and control of an individual who holds an appropriate license or officer endorsement on his or her MMC. The Medical Certificate for the Master is Expired.
Action required: 705 - Other - as specified
Resolved 5 April 2025
Resolution: New Medical Certificate issued.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 June 2024 No resolution recorded
Vessels which transport more than six passengers for hire are required to comply with a radiotelephone installation complying with this subpart. Communications Act Safety Radiotelephony Certificate is expired.
Action required: 50 - Rectify deficiencies w/in 30 days
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 June 2024 No resolution recorded
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Starboard running light is not operational and anchor light needs to be elevated above the search light so it is not obstructed
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 June 2024 No resolution recorded
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required.
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 June 2024 No resolution recorded
An adult life jacket must be provided for each person carried on board a vessel and each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Provide an additional 3 adult size PFDs and properly mark the child size PFD stowage location.
Action required: 50 - Rectify deficiencies w/in 30 days
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 January 2021 Resolved
Any vessel of at least five net tons which engages in Coastwise Trade must have a Certificate of Documentation. Vessel is currently registered with the State of South Carolina. Based on vessels net tonnage, the vessel is required to be federally documented with the U.S. Coast Guard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 February 2023
Resolution: Vessel has valid COD
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 January 2021 Resolved
Any vessel that engages in unrestricted coastwise trade is required to possess a coastwise endorsement on its Certificate of Documentation (COD). The vessel meets the definition of coastwise trade and is required to possess a valid coastwise endorsement on its COD.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 February 2023
Resolution: Vessel has valid COD
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 January 2021 Resolved
The official number of a vessel must be preceded by the abbreviation "NO" and must be marked in block arabic numerals not less than 3" in height on an interior structural part of the vessels hull. Once assigned, the official number shall be marked as described above.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 February 2023
Resolution: Official Number marked on the vessel
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 January 2021 Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port & starboard bow and the stern of the vessel. The haling port must be marked on some clearly visible exterior part of the stern of the vessel. Vessels name & hailing port markings shall be verified.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 February 2023
Resolution: Vessel properly marked
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 March 2020 Resolved
Vessel required to be fitted with suitable propulsion equipment. Attending Inspector(s) noted loose/missing mounting hardware for port outboard motor IWO transom.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2020
Resolved 14 April 2020
Resolution: Attending Inspector(s) verified mountings for propulsion system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 March 2020 Resolved
Vessel's fuel fills are required to be bonded to prevent the build up of static electricity. Attending Inspector(s) noted that the port/starboard fuel fill bonding straps were wasted/disconnected.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2020
Resolved 14 April 2020
Resolution: Attending Inspector(s) verified repairs to fuel storage system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 March 2020 Resolved
Vessels fuel tanks are required to be fitted with a vent. Existing vents are equipped with flexible hose connections and are secured with metallic hose clamps. Existing clamps were found wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2020
Resolved 14 April 2020
Resolution: Attending Inspector(s) verified the renewal of metallic hose clamps IWO fuel tank vent flex hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 March 2020 Resolved
Vessels electrical conductors are required to be properly supported. Existing conductors along with steering hoses were found unsecured/unsupported (underside of deck/between sponsons).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2020
Resolved 14 April 2020
Resolution: Attending Inspector(s) verified installation of supports for electrical conductors/steering hoses.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2020 Resolved
Vessel required to post PFD donning instructions. Existing PFD donning instructions are worn/faded.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2020
Resolved 14 April 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 March 2020 Resolved
Vessel required to exhibit proper arc of visibility for navigational side lights. Port navigational side light was mounted at a downward angle.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2020
Resolved 14 April 2020
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 March 2020 Resolved
Vessel required to carry current/up to date marine charts for areas transited. Existing charts are outdated (2016).
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2020
Resolved 14 April 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 March 2020 Resolved
Vessel required to be equipped with peripheral railings. Railings IWO port bow were found loose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2020
Resolved 14 April 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 March 2020 Resolved
Portable fire extinguishers are required to be stowed to prevent movement/falling. Bracket for portable fire extinguisher IWO port bow was not capable of being fastened.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2020
Resolved 14 April 2020
Documentation › Markings/Placards › Warning Signs
Issued 13 March 2018 Resolved
Vessels emergency escapes were not properly marked.
Action required: 705 - Other - as specified
Due 27 March 2018
Resolved 26 March 2018
Resolution: Attending Inspectors verified the installation of signage for vessels emergency exits.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 March 2018 Resolved
Vessels Type III MSD was not equipped with operating instructions.
Action required: 705 - Other - as specified
Due 27 March 2018
Resolved 26 March 2018
Resolution: Attending Inspectors verified posting of operating instructions for Type III MSD.
Lifesaving › Lifebuoys › Serviceable
Issued 13 March 2018 Resolved
Vessels ring buoy was found damaged.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2018
Resolved 26 March 2018
Resolution: Attending Inspector(s) verified replacment of damaged ring buoy.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 March 2018 Resolved
Vessel did not carry current/up to date navigational publications (CG Light List, Tidal Current Tables, Coast Pilot).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2018
Resolved 26 March 2018
Resolution: Attending Inspector(s) verified the carriage of current/up to date navigational publications for areas transited.
Navigation › Piloting/Steering › Marine Charts
Issued 13 March 2018 Resolved
Vessel did not carry current/up to date marine charts for areas transited.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2018
Resolved 26 March 2018
Resolution: Attending Inspector(s) verified the carriage of current/up to date marine charts for areas transited.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 13 March 2018 Resolved
Vessel's FCC Safety Radio-telephony Certificate was found expired.
Action required: 705 - Other - as specified
Due 27 March 2018
Resolved 26 March 2018
Resolution: Attending Inspector(s) verified the carriage of a current/up to date FCC Safety Radio-telephony Certificate.
Communications › Radio Communications › VHF Radiotelephone
Issued 13 March 2018 Resolved
Vessels VHF-FM radio was not properly programmed with MMSI # (DSC Equipped).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 March 2018
Resolved 26 March 2018
Resolution: Attending Inspector(s) verified programming of VHF-FM DSC equipped marine radio.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 March 2018 Resolved
Attending Inspector(s) condemned 14 adult Type I PFD's due to material condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2018
Resolution: Attending Inspector received confirmation from vessel representative advising that all 14 adult Type I PFD's had been received/placed in service on board the subject vessel.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 March 2018 Resolved
Vessels starboard bow railing missing hardware/loose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2018
Resolved 26 March 2018
Resolution: Attending Inspector(s) verified installation of hardware IWO starboard bow railing.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 March 2018 Resolved
Vessels peripheral railings were found loose/requiring adjustment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2018
Resolved 26 March 2018
Resolution: Attending Inspector(s) verified adjustments made IWO vessels peripheral railings.
Construction/Loadline › Penetrations › Weld
Issued 6 March 2018 Resolved
Attending Inspector(s)noted a fractured weldment IWO port sponson @ cross deck structure between voids #1/2.
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 7 March 2018
Resolution: Attending Inspector(s) witnessed removal of existing weldment (fractured) and verified the final installation of aluminum gusset/weldments.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 6 March 2018 Resolved
Attending Inspector(s) noted that the vessels fuel fill(s) for port & starboard fuel tanks were not secured properly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 7 March 2018
Resolution: Attending Inspector(s) verified installation of proper type/qty of clamps for port & starboard fuel fills.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 6 March 2018 Resolved
Attending Inspector(s) noted that the port fuel tank flame screen was detached from side shell of hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 7 March 2018
Resolution: Attending Inspector(s) verified installation of new flame screen assembly IWO port fuel tank/hull.
Communications › Radio Communications › VHF Radiotelephone
Issued 17 February 2017 Resolved
VHF-FM marine radio not programmed with MMSI number (DSC equipped).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 17 March 2017
Resolution: Attending Inspector verified programming of VHF-FM radiotelephone.
Navigation › Piloting/Steering › Marine Charts
Issued 17 February 2017 Resolved
Vessel not equipped with current/up to date marine charts for areas transited.
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 17 March 2017
Resolution: Attending Inspector verified carriage of current/up to date marine charts for areas transited.
Navigation › Piloting/Steering › US Coast Pilot
Issued 17 February 2017 Resolved
Vessel not equipped with current/up to date navigational publications (Coast Pilot [name withheld])
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 17 March 2017
Resolution: Attending Inspector verified carriage of current/up to date navigational publications for areas transited.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 February 2017 Resolved
Replace five Type I PFD's
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 March 2017
Resolved 17 March 2017
Resolution: Attending Inspector verified replacement of Type I PFD's.
Engineering › Fuel Oil Service System › Hose
Issued 17 February 2017 Resolved
Remove existing fuel supply hose (to engine) and replace with USCG approved fuel hose.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 17 March 2017
Resolution: Attending Inspector verified replacement of fuel hose.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 March 2010 Resolved
Provide metal clip for self activating light on life ring
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2010
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 11 March 2010 Resolved
Remove all articles from child life jacket stowage and properly stow all child size lifejackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2010
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 11 March 2010 Resolved
Provide proof of drug consortium enrollment for all crew
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 11 March 2010 Resolved
Provide proof of servicing for portable fire extimguishers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 29 April 2009 Resolved
Provide proof of servicing fire extinguishers or replace.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 1 May 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 April 2009 Resolved
Make repairs to damaged stantion on aft end of vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 1 May 2009
Lifesaving › Lifebuoys › Serviceable
Issued 24 April 2007 Resolved
Permanently attached line on life ring was rotted from UV exposure.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2007
Resolution: O/O purchased new life ring.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 24 April 2007 Resolved
01 adult PFD was dry rotted and tore easily.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2007
Resolution: O/o purchased 01 new adult PFD.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 April 2007 Resolved
Battery for life ring water light was expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2007
Resolution: O/O purchased new battery for waterlight.
Documentation › Markings/Placards › Warning Signs
Issued 30 March 2006 Resolved
Properly mark exits "emergency exit keep clear."
Condition: Placed in Improper Service
Due 23 April 2006
Resolved 29 June 2006
Resolution: Emergency exits marked
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 30 March 2006 Resolved
Provide non combustible trash cans or liners
Condition: Improper Installation
Due 23 April 2006
Resolved 29 June 2006
Resolution: Purchased non-combustible trash cans
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 30 March 2006 Resolved
Properly label pfd's with vessel name
Condition: Improper Installation
Due 23 April 2006
Resolved 29 June 2006
Resolution: PDD''s labeled with vessel name
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 30 March 2006 Resolved
Provide new reflective tape on worn pfd's
Condition: Improper/Lack of Maintenance
Due 23 April 2006
Resolved 29 June 2006
Resolution: Replaced reflective tape on worn PFD''S
Fire Fighting › Fire Bucket › Stenciling
Issued 30 March 2006 Resolved
Properly stencil fire buckets
Condition: Improper/Lack of Maintenance
Due 23 April 2006
Resolved 29 June 2006
Resolution: stenciled all fire buckets
Construction/Loadline › Hull › Side Shell
Issued 30 January 2006 Resolved
07 small cracks were found at various points in the side shells of both pontoons, most being located in the 'stitch' welds connecting the deck framing with the pontoons.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 February 2006
Resolution: Rewelded all stitch welds and cracks.
Construction/Loadline › Hull › Bottom Plating
Issued 30 January 2006 Resolved
Port side water baffle for outboard engine steering linkage was not properly secured. Welding and missing bolts are required.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 February 2006
Resolution: Welded weak areas on baffle.
Engineering › Steering Gear System › Fastener
Issued 30 January 2006 Resolved
Due to the heads of the bolts for the steering linkage at the engine steering arm being installed from the bottom up with no way to positively secure them from vibrating loose and then falling out, the vessel was required to install longer bolts w/ either cotter pinned nuts or 'nylock' lock nuts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 February 2006
Resolution: Installed longer bolts and nylock nuts.
Stability › Watertight Integrity › General
Issued 30 January 2006 Resolved
Penetrations through decking for wire runs and plumbing were not made water tight due to new installation. Vessel instructed to make as such.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 February 2006
Resolution: Used suitable marine grade sealant to seal all thru holes.
Communications › Visual Communication
Issued 15 April 2004 Resolved
Emergency instruction list not posted
Due 29 April 2004
Resolved 15 April 2004
Construction/Loadline › Structures
Issued 19 February 2004 Resolved
Small weld fractures at # 9 & 12 transverse and main longtitude beam tee connection.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 3 March 2004
Resolution: Re-welds complete - all sat
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 2 May 2002 Resolved
provide proper service tags for the newly installed portable fire extinguishers. LEGACY COMPONENT DESC: Service
Due 16 May 2002
Resolved 17 March 2003
Resolution: deficiency corrected satisfactorily
Operations/Management › Navigation Safety
Issued 2 May 2002 Resolved
Obtain up to date publications for the area of operation or acceptable excerpts of the same. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Due 16 May 2002
Resolved 17 March 2003
Resolution: deficiency corrected satisfactorily
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 March 2002 Resolved
Properly repair cracked welds and broken frame located starboard side last aft frame inside pontoons.
Action required: 705 - Other - as specified
Due 11 March 2002
Resolved 11 March 2002
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 March 2002 Resolved
Clean welds and repair fractured weldsas marked starboard side aft outer pontoon.
Action required: 705 - Other - as specified
Due 11 March 2002
Resolved 11 March 2002
Electrical › Electric Supply System (service) › Cable
Issued 7 March 2002 Resolved
Properly remove dead end wiring starboard engine box.
Action required: 705 - Other - as specified
Due 11 March 2002
Resolved 11 March 2002
Construction/Loadline › Structures › Ventilators
Issued 7 March 2002 Resolved
Clean area in way of fuel vent and hose assemblies to port and starboard fuel tanks for further examination.
Action required: 705 - Other - as specified
Due 11 March 2002
Resolved 11 March 2002
Resolution: Found all connections to be satisfactory, no repairs required.
Construction/Loadline › Penetrations › Weld
Issued 7 March 2002 Resolved
Gouge and reweld fractures located at frame #'s 5 and 6 port side.
Action required: 705 - Other - as specified
Due 11 March 2002
Resolved 11 March 2002
Construction/Loadline › Hull › Bracket
Issued 7 March 2002 Resolved
Clean trip brackets and reweld as needed marked by frame #'s 5 and 6 port side.
Action required: 705 - Other - as specified
Due 11 March 2002
Resolved 11 March 2002
Construction/Loadline › Hull › Weld
Issued 7 March 2002 Resolved
Reweld cracked weld starboard side frame 4.
Action required: 705 - Other - as specified
Due 11 March 2002
Resolved 11 March 2002
Fire Fighting
Issued 17 April 2001 Resolved
PROVIDE PROOF OF PORTABLE FIRE EXTINGUISHERS' INSPECTION
Condition: Unknown
Due 25 April 2001
Resolved 27 April 2001
Electrical
Issued 17 April 2001 Resolved
MOUNT BATTERY BOXES.
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Lifesaving
Issued 17 April 2001 Resolved
PLACE RETROFLECTIVE TAPE ON RING BUOY.
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Lifesaving
Issued 17 April 2001 Resolved
REPLACE WATERLIGHT LANYARD WITH 3'TO 6' LANARD OF SIMILAR LINE AS RINGBUOY.
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Lifesaving
Issued 13 April 1999 Resolved
REPLACE MISSING ITEMS IN FIRST AID KIT.
Condition: Unknown
Due 20 April 1999
Resolved 27 May 1999
Fire Fighting
Issued 13 April 1999 Resolved
PROVIDE PURCHASE RECEIPT FOR FIRE EXTINGUISHERS.
Condition: Unknown
Due 20 April 1999
Resolved 27 May 1999
Lifesaving
Issued 13 April 1999 Resolved
REPAIR OR REPLACE RINGBUOY.
Condition: Unknown
Due 20 April 1999
Resolved 27 May 1999
Lifesaving
Issued 7 April 1998 Resolved
PROVIDE ONE ADDITIONAL CHILD'S PFD
Condition: Unknown
Due 7 May 1998
Resolved 13 April 1998
Lifesaving
Issued 7 April 1998 Resolved
PROVIDE LIFE JACKET PLACARD CONTAINING INSTRUCTIONS FOR THE DONNING AND USEOF THE VEST TYPE PFDs ON BOARD IAW 46CFR185.516.
Condition: Unknown
Due 7 May 1998
Resolved 13 April 1998
Lifesaving
Issued 11 April 1997 Resolved
LABEL ADULT LIFE PRESERVER LOCKERS.
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Fire Fighting
Issued 11 April 1997 Resolved
HAVE 1 B-I AND 1 B-II FIRE EXTINGUISHERS PROFESSIONALLY SERVICED.
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Lifesaving
Issued 11 April 1997 Resolved
REPLACE 24 ADULT AND 1 CHILD LIFE PRESERVERS. VESSEL IS LIMITED TO CARRIAGEOF 18 ADULTS AND 4 CHILDREN UNTIL CORRECTED.
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Engineering
Issued 11 April 1997 Resolved
LABEL REMOTE FUEL SHUTOFF VALVES.
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Electrical
Issued 11 April 1997 Resolved
REPLACE PARTIALLY CORRODED CABLE TERMINALS ON POSITIVE SIDE OF STBD BATTERY.
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Navigation
Issued 11 April 1997 Resolved
PROVIDE PUBLICATIONS AND CHARTS FOR AREA OF OPERATIONS: LIGHT LIST, COAST PILOT, TIDE & CURRENT TABLES...
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Fire Fighting
Issued 24 April 1996 Resolved
HAVE THE B-I AND ONE OF THE B-II PORTABLE FIRE EXTINGUISHERS SERVICED BY A LICENSED FIRE SERVICE FACILITY.
Condition: Unknown
Due 24 May 1996
Resolved 6 May 1996
Electrical
Issued 24 April 1996 Resolved
REPLACE WIRE NUT CONNECTOR IN CONTROL CONSOLE WITH A CRIMP TYPE CONNECTOR.
Condition: Unknown
Due 24 May 1996
Resolved 6 May 1996
Documentation
Issued 24 April 1996 Resolved
PROVIDE WRITTEN DRUG POLICY.
Condition: Unknown
Due 1 May 1996
Resolved 6 May 1996
Documentation
Issued 24 April 1996 Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 24 May 1996
Resolved 6 May 1996
Lifesaving
Issued 24 April 1996 Resolved
LABEL CHILD LIFE PRESERVER LOCKER "5 CHILD LIFE PRESERVERS".
Condition: Unknown
Due 24 May 1996
Resolved 6 May 1996
Lifesaving
Issued 24 April 1996 Resolved
PROVIDE TAG LINE TO ATTACH DISTRESS MARKER LIGHT TO THE LIFE RING.
Condition: Unknown
Due 24 May 1996
Resolved 6 May 1996
Lifesaving
Issued 24 April 1996 Resolved
PROVIDE SEVEN ADULT LIFE PRESERVERS. THE VESSEL IS LIMITED TO THE CARRIAGE OF THIRTY FIVE TOTAL PERSONS UNTIL CORRECTED.
Condition: Unknown
Due 24 May 1996
Resolved 6 May 1996
Fire Fighting
Issued 5 June 1995 Resolved
RECHARGE ONE B-II DRY CHEMICAL FIRE EXTINGUISHER.
Condition: Unknown
Due 9 June 1995
Resolved 7 June 1995
Lifesaving
Issued 19 April 1994 Resolved
PROVIDE USCG APPROVED RETRO-REFLECTIVE TAPE FOR THE LIFE RING.
Condition: Unknown
Due 19 May 1994
Resolved 12 May 1994
Lifesaving
Issued 19 April 1994 Resolved
REPLACE TWO ADULT LIFE PRESERVERS AND RENEW THE RETRO-REFLECTIVE TAPE (USCGAPPROVED) ON FOURTEEN OTHERS. VESSEL IS LIMITED TO THE CARRIAGE OF 24 PASSENGERS AND 2 CREW FOR A TOTAL OF 26 PERSONS UNTIL ALL SIXTEEN HAVE BEENREPLACED OR REPAIRED.
Condition: Unknown
Due 19 May 1994
Resolved 12 May 1994
Fire Fighting
Issued 19 April 1994 Resolved
REPLACE ONE B-I FIRE EXTINGUISHER WITH A B-II.
Condition: Unknown
Due 19 May 1994
Resolved 12 May 1994
Navigation
Issued 8 February 1994 Resolved
REPLACE TWO BOLTS ATTACHING STEERING LINKAGE TO PORT AND STARBOARD ENGINES AND ENSURE THEY ARE PROPERLY SECURED.
Condition: Unknown
Due 8 February 1994
Resolved 8 February 1994
Documentation
Issued 27 April 1990 Resolved
UPDATE FCC OPERATORS PERMIT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 27 April 1990
Resolved 27 April 1990
Lifesaving
Issued 27 April 1990 Resolved
PROVIDE REFLECTIVE TAPE FOR 1 ADULT PFD.
Condition: Unknown
Due 27 April 1990
Resolved 27 April 1990
Lifesaving
Issued 27 April 1990 Resolved
PROVIDE NEW PFD TO REPLACE THE ONE REJECTED DURING INSPECTION.
Condition: Unknown
Due 27 April 1990
Resolved 27 April 1990
Electrical
Issued 27 April 1990 Resolved
PROVIDE EMERGENCY LIGHTING FOR VESSEL PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 27 April 1990
Resolved 27 April 1990
Lifesaving
Issued 26 April 1988 Resolved
PROVIDE FIVE CHILDS SIZE PFD'S PRIOR TO CARRYING CHILDREN.
Condition: Unknown
Due 26 April 1988
Resolved 26 April 1988
Lifesaving
Issued 21 October 1987 Resolved
PROVIDE 5 CHILDS TYPE I PFD'S
Condition: Unknown
Due 21 October 1987
Resolved 21 October 1987
Lifesaving
Issued 21 October 1987 Resolved
PROVIDE 60FT LINE FOR RING BOUY
Condition: Unknown
Due 21 October 1987
Resolved 21 October 1987
Lifesaving
Issued 21 October 1987 Resolved
PROVIDE 6 ADULT TYPE I PFD'S
Condition: Unknown
Due 21 October 1987
Resolved 21 October 1987
Navigation
Issued 21 October 1987 Resolved
MAKE OPERATIONAL NAV/LTS
Condition: Unknown
Due 21 October 1987
Resolved 21 October 1987
Fire Fighting
Issued 21 October 1987 Resolved
REPAIR FIRE EXTINGUISHER BRACKET, PORT SIDE AFT
Condition: Unknown
Due 21 October 1987
Resolved 21 October 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.