Records from 2001 to 2022. Most recent: inspection, 3 November 2022.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 23
3 November 2022
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7580373
3 November 2021
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7344793
8 October 2020
COI Inspection · DAPI Audit · Administrative Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7074225
26 November 2019
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6854215
16 October 2018
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6547676
4 October 2017
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6281170
30 September 2016
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5995615
28 September 2015
COI Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5726592
15 October 2014
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5005326
27 September 2011
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4154673
15 February 2011
Type not recorded
No type recorded · Marine Safety Center (MSC) · Activity 3983580
20 January 2011
In-Service Inspection · Simplified Stability Test · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3934910
25 September 2008
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3334883
6 June 2008
Simplified Stability Test
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3275792
2 October 2007
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3077042
17 October 2006
COI Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2803498
20 June 2006
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2779231
3 February 2006
Simplified Stability Test
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2578584
13 July 2005
Hull Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2426664
14 July 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2130300
7 March 2003
Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1752362
15 January 2002
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1479559
13 March 2001
Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1366250
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 November 2022
Resolved
Each ring buoy on a vessel must be approved in accordance with 46 CFR 160.050 in Subchapter Q of this chapter, or other standard specified by the Commandant.
MI identified grab line on ring buoy to be in a wasted condition.
46 CFR 180.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 29 November 2022
Resolution: Received photos of new life ring buoy.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 November 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation.
MI identified the fuel shutoff quick release was not labeled.
46 CFR 185.608
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 29 November 2022
Resolution: Received photo of properly labeled fuel shut off valve.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 November 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible.
MI identified that the vessel was missing charts for its area of operation.
46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 29 November 2022
Resolution: Received photo of satisfactory chart onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 November 2022
Resolved
A vessel must carry a first-aid kit approved under approval series 46 CFR 160.041, or with equivalent contents.
MI identified that the vessel's first-aid kit did not contain Aspirin.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 29 November 2022
Resolution: Received photo of newly purchased aspirin bottle.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 December 2020
Resolved
Ring life buoy was deteriorated.
Action required: 10 - Deficiency Rectified
Due 3 December 2020
Resolved 3 December 2020
Resolution: Buoy was replaced with new during inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 October 2020
Resolved
46 CFR 176.404 - An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. It normally includes inspection and testing of the structure, machinery, equipment, and on a sailing vessel, rigging and sails.
O/O failed to renew vsl COI on 28SEP2020.
Action required: 10 - Deficiency Rectified
Due 22 October 2020
Resolved 3 December 2020
Resolution: Vessel completed COI inspection on 03Dec2020:
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 October 2020
Resolved
46 CFR 176.600 (c)(2) - A vessel that is exposed to salt water not more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every five years. Vessel did not conduct a scheduled dry dock prior to September 30, 2020.
Action required: 10 - Deficiency Rectified
Due 22 October 2020
Resolved 3 December 2020
Resolution: Vessel completed drydock on 03Dec2020:
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 October 2020
Resolved
Vessel's flares expired.
Action required: 10 - Deficiency Rectified
Due 8 October 2020
Resolved 8 October 2020
Resolution: Owner replaced with new flares during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 October 2018
Resolved
Vessel's ring buoy is unserviceable. Replace ring buoy with an approved one meeting 46 CFR 160.050.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 October 2018
Resolved 16 October 2018
Resolution: New ring buoy installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 October 2018
Resolved
Provide first aid kit approved under 46CFR160.041 or a kit with equivalent contents and instructions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2018
Resolved 15 November 2018
Resolution: Provided medical first aid kit onboard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 October 2018
Resolved
Properly secure battery on stern.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2018
Resolved 15 November 2018
Resolution: Properly secured battery
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 16 October 2018
Resolved
Provide placard containing instructions for the donning and use of the lifejackets onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2018
Resolved 15 November 2018
Resolution: Provided lifejacket placard onboard
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 October 2018
Resolved
Commence logging emergency drills including man-overboard and fire fighting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2018
Resolved 15 November 2018
Resolution: Provided log book and commenced logging drills
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 16 October 2017
Resolved
Install an A-11 and B-1 portable fire extinguisher aboard vessel. 46 CFR 181.30
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2017
Resolution: A-11 and B-1 fire extinguishers installed onboard.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 16 October 2017
Resolved
No emergency instructions posted. 46 CFR 185.510
Due 23 October 2017
Resolved 16 October 2017
Resolution: Emergency instructions posted.
Construction/Loadline › Hull › Weld
Issued 27 September 2011
Resolved
Repair cracked welds on the dive ladder rungs.
Due 27 October 2011
Resolved 12 October 2011
Resolution: Welds repaired.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 27 September 2011
Resolved
Replace anchor line due to parting.
Due 27 October 2011
Resolved 12 October 2011
Resolution: Anchor line repalced.
Construction/Loadline › Hull › Weld
Issued 17 October 2006
Resolved
Make repairs to port and stbd pontoons.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2006
Resolution: Repairs made to the satisfaction of attending inspector.
Construction/Loadline › Hull › Hull Plating
Issued 13 July 2005
Resolved
Crop and renew improper weld repair IWO STBD pontoon, inside approx 3 ft from stern as discussed. They damaged an exciting insert and spot welded the holes/cracks.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 July 2005
Resolved 23 January 2006
Resolution: CORRECTED EARLIER, BUT 835 NEVER CLEARED FROM MISLE.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 7 March 2003
Resolved
PERMANENTLY ETCH OR ATTACH TO THE AFTER END (ABOVE THE WATERLINE) OF EACH HULL THE VESSEL HULL IDENTIFICATION NUMBER (16554) AS SHOWN ON FLORIDA REGISTRATION.
Due 25 April 2003
Resolved 14 July 2004
Construction/Loadline › Hull › Keel
Issued 15 January 2002
Resolved
Make repairs to the starboard pontoon forward bow where the dent caused by hitting the dock caused a crack in the rub rail of the stem. Corrected on 16Jan02.
Due 16 January 2002
Resolved 16 January 2002
Resolution: Owner had bow stem welded.