MAURY USCG vessel records
← All vessels

HALF PINT

HALF PINT is a 1975 passenger vessel (inspected). The Coast Guard has recorded 7 inspections since 2016, most recently in November 2022, along with 15 deficiencies.

Records from 2016 to 2022. Most recent: inspection, 3 November 2022.

Built
1975
Last inspected
3 November 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
Maury page id
psix-24942

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 7 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

3 November 2022 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7580373
3 November 2021 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7344793
8 October 2020 COI Inspection · DAPI Audit · Administrative Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7074225
26 November 2019 DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6854215
16 October 2018 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6547676
4 October 2017 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6281170
30 September 2016 DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5995615

Deficiency record · 15

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 November 2022 Resolved
Each ring buoy on a vessel must be approved in accordance with 46 CFR 160.050 in Subchapter Q of this chapter, or other standard specified by the Commandant. MI identified grab line on ring buoy to be in a wasted condition. 46 CFR 180.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 29 November 2022
Resolution: Received photos of new life ring buoy.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 November 2022 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. MI identified the fuel shutoff quick release was not labeled. 46 CFR 185.608
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 29 November 2022
Resolution: Received photo of properly labeled fuel shut off valve.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 November 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. MI identified that the vessel was missing charts for its area of operation. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 29 November 2022
Resolution: Received photo of satisfactory chart onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 November 2022 Resolved
A vessel must carry a first-aid kit approved under approval series 46 CFR 160.041, or with equivalent contents. MI identified that the vessel's first-aid kit did not contain Aspirin. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 29 November 2022
Resolution: Received photo of newly purchased aspirin bottle.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 December 2020 Resolved
Ring life buoy was deteriorated.
Action required: 10 - Deficiency Rectified
Due 3 December 2020
Resolved 3 December 2020
Resolution: Buoy was replaced with new during inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 October 2020 Resolved
46 CFR 176.404 - An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. It normally includes inspection and testing of the structure, machinery, equipment, and on a sailing vessel, rigging and sails. O/O failed to renew vsl COI on 28SEP2020.
Action required: 10 - Deficiency Rectified
Due 22 October 2020
Resolved 3 December 2020
Resolution: Vessel completed COI inspection on 03Dec2020:
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 October 2020 Resolved
46 CFR 176.600 (c)(2) - A vessel that is exposed to salt water not more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every five years. Vessel did not conduct a scheduled dry dock prior to September 30, 2020.
Action required: 10 - Deficiency Rectified
Due 22 October 2020
Resolved 3 December 2020
Resolution: Vessel completed drydock on 03Dec2020:
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 October 2020 Resolved
Vessel's flares expired.
Action required: 10 - Deficiency Rectified
Due 8 October 2020
Resolved 8 October 2020
Resolution: Owner replaced with new flares during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 October 2018 Resolved
Vessel's ring buoy is unserviceable. Replace ring buoy with an approved one meeting 46 CFR 160.050.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 October 2018
Resolved 16 October 2018
Resolution: New ring buoy installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 October 2018 Resolved
Provide first aid kit approved under 46CFR160.041 or a kit with equivalent contents and instructions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2018
Resolved 15 November 2018
Resolution: Provided medical first aid kit onboard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 October 2018 Resolved
Properly secure battery on stern.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2018
Resolved 15 November 2018
Resolution: Properly secured battery
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 16 October 2018 Resolved
Provide placard containing instructions for the donning and use of the lifejackets onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2018
Resolved 15 November 2018
Resolution: Provided lifejacket placard onboard
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 October 2018 Resolved
Commence logging emergency drills including man-overboard and fire fighting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2018
Resolved 15 November 2018
Resolution: Provided log book and commenced logging drills
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 16 October 2017 Resolved
Install an A-11 and B-1 portable fire extinguisher aboard vessel. 46 CFR 181.30
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2017
Resolution: A-11 and B-1 fire extinguishers installed onboard.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 16 October 2017 Resolved
No emergency instructions posted. 46 CFR 185.510
Due 23 October 2017
Resolved 16 October 2017
Resolution: Emergency instructions posted.

Ownership record