MAURY USCG vessel records Sign in
← All vessels

MPP TRIUMPH

MPP TRIUMPH is a 2001 freight ship. The Coast Guard has recorded 12 inspections since 2001, most recently in February 2012, along with 10 deficiencies and 2 operational controls.

Records from 2001 to 2012. Most recent: operational control imposed, 4 February 2012.

Built
2001
Last inspected
3 February 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9235139 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MARSHALL ISLANDS
—
Maury page id
psix-24957

Inspections, by type

…with no type recorded4
Years with a record 9 calendar years (2001–2012)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it8733 - Dead Weight, Ton
12023 - Displacement, Ton
6714 - Convention (Subpart B), Gross Ton
6714 - Regulatory (Subpart C or D), Gross Ton
2893 - Convention (Subpart B), Net Ton
2893 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 12

3 February 2012 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4238072
24 February 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3951951
17 June 2008 MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3239050
18 March 2008 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3166691
28 February 2008 ISPS II Exam · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3155042
22 September 2007 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3063527
25 June 2006 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2690806
18 August 2005 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2468069
31 January 2005 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2283575
28 March 2004 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2048073
6 March 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1753321
29 April 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 289626

Deficiency record · 10

Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 25 February 2011 Resolved
Any required fire detection system shall be capable of immediate operation at all times. Ships smoke detectors were found with missing covers and with covers taped on. This condition could cause damage to the smoke detectors sensor.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 February 2012
Resolution: Received satisfactory class report
Construction/Loadline › Structures › Manhole
Issued 25 February 2011 Resolved
Manholes shall be closed by covers capable of being made watertight. Manhole cover for the Bilge Holding tank has been modified by the crew to house a drainage pipe that has not been approved by Class.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 February 2012
Resolution: Received satisfactory class report
Fire Fighting › Structural - A Class Divisions › Special Category Spaces
Issued 24 February 2011 Resolved
Where Class "A" divisions are penetrated for the passage of electric cable arrangements shall be made to ensure fire resistance is not impaired. A hole was found in the steering gear room overhead; fixed with cement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 25 February 2011
Resolution: Fixed with cement patch.
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 24 February 2011 Resolved
Suitable instructions and components for testing and maintenance shall be provided. Crew was found testing the heat detectors with an open flame. Heat detectors should be tested in accordance with manufacturer’s instructions.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 February 2012
Resolution: Received satisfactory class report
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 24 February 2011 Resolved
The company should establish plans and instructions for key shipboard operations. Vessel has no procedures for switching from HFO to MGO. Cite: ISM 7
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 February 2012
Resolution: Received satisfactory class report
Lifesaving › Lifebuoys › Size
Issued 24 February 2011 Resolved
Self-activating smoke signals required by SOLAS III 7.1.3 shall be connected to a lifebuoy having a mass meeting manufacturers requirements. Vessel is using a lifebuoy of insufficient weight.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 February 2012
Resolution: Received satisfactory class report
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 June 2008 Resolved
Conducted test of the OWS and the system worked then tripped when sensor was interrupted. The solenoid and pump went off line. As the ppm dropped below 15 the pump came on then went off, seized and finally no power going to the pump itself (failed). (Read summary)
Condition: Unknown
Due 10 July 2008
Resolved 7 September 2008
Resolution: At the request of owner''s representative Class completed an onboard survey on 07SEP08. Complete and definitive repairs to the OWS were made and demonstration of proper operation and alarms were confirmed satisfactory by the surveyor.
Lifesaving › Line-Throwing Appliances › Lines
Issued 22 September 2007 Resolved
Three line throwers and one rocket on the required four line throwing appliances were expired. SOLAS 74 Amended Chapt.3 Reg 18 LAS Chapt. VII To the satisfaction of RSO
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 October 2007
Resolved 26 September 2007
Resolution: PSC Dispatcher Received faxed delivery notice dated 25 Sept., showing delivery and receipt of three line throwing apparatus and one spare rocket to the MV CEC Castle.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 25 June 2006 Resolved
The vessels shared earth ground detection device is not operating properly.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 June 2006
Resolved 29 June 2006
Resolution: received a report from [name withheld] stating that they replaced burnt fuse for the instrument, tested the instrument and found it to be satisfactory.
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 August 2005 Resolved
Vsl issued Letter of Deviation for inoperative Radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2005
Resolution: Radar operational.

Ownership record