MAURY USCG vessel records Sign in
← All vessels

MINOUCHE

MINOUCHE is a 1980 freight ship. The Coast Guard has recorded 84 inspections since 1985, most recently in January 2024, along with 103 deficiencies and 46 operational controls.

Records from 1985 to 2024. Most recent: inspection, 28 January 2024.

Built
1980
Last inspected
28 January 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7930553 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
CPB-2895
249571
Flag
BOLIVIA
—
Maury page id
psix-249571

Inspections, by type

…with no type recorded57
Years with a record 18 calendar years (1985–2024)
The 84 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it521 - Convention (Subpart B), Net Ton
1300 - Dead Weight, Ton
499 - Regulatory (Subpart C or D), Gross Ton
1167 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 84

28 January 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7856756
13 June 2014 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4887807
15 March 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3695591
18 January 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3665217
8 July 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3525098
7 July 2009 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3526866
20 April 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3453813
20 April 2009 ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3455173
4 March 2009 ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3427051
11 February 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3416090
13 January 2009 PI Safety Exam · ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3391686
12 January 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3391522
24 November 2008 ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3367245
24 November 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3369436
21 November 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3367406
1 October 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3337183
30 September 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3335576
29 September 2008 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3334897
20 August 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3304743
13 August 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3297729
28 May 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3220135
26 May 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3217770
24 May 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3215217
13 March 2008 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 3164123
11 March 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3162445
16 January 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3131505
13 January 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3129587
17 September 2007 MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3059579
21 June 2007 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2968699
20 June 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2967767
20 March 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2891092
18 March 2007 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2892206
20 February 2007 PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2871299
12 February 2007 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2872519
9 February 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2869985
19 October 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2803660
19 October 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2803996
4 May 2006 Deficiency Check · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2640390
13 December 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2550852
1 November 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2528340
16 August 2005 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2464507
3 August 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2450218
23 June 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2399804
25 May 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2368117
15 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2334645
13 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2332667
13 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2332668
6 March 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2304280
21 January 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2278356
27 December 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2264896
2 December 2004 Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2251795
5 November 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2235189
28 September 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2212155
27 September 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2206001
16 August 2004 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2167305
16 August 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2168368
13 August 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2164891
30 June 2004 ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2116596
18 June 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2104308
16 June 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2100440
13 June 2004 Type not recorded
No type recorded · GROUP MIAMI · USCG Southeast District (CGD-SE) · Activity 2096604
4 May 2004 Deficiency Check · Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2058817
3 May 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2057337
15 February 2004 Type not recorded
No type recorded · USCGC FARALLON (WPB 1301) · USCG Southeast District (CGD-SE) · Activity 2016197
9 December 2003 Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1961127
14 November 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1947819
18 August 2003 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1879421
10 July 2003 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1841683
10 June 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1813785
22 April 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1778222
22 April 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1778717
9 October 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1687161
9 August 2002 Administrative Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1659532
20 March 2002 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1495260
13 March 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 288031
9 April 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 276676
26 August 1998 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 419597
27 July 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 533856
16 May 1996 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 391340
25 April 1996 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 390540
26 May 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 693517
6 May 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 358001
17 July 1989 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 447032
23 May 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 302062

Deficiency record · 103

Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 20 October 2009 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2009
Resolution: Vessel agent provided office with a copy of the 3rd assistant engineer''s flag state endoresement
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 7 July 2009 Resolved
Certificate is expired. It was improperly endorsed trying extend the period of validity.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2009
Resolution: Vessel had survey done and provided valid CCSRC.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 7 July 2009 Resolved
Vessel's Int'l Oil Pollution Certificate Expired
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2009
Resolution: Vessel had survey completed and new certificates assigned.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 7 July 2009 Resolved
Load Line Certificate expired
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2009
Resolution: Vessel had LL survey completed and new certificate issued.
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 7 July 2009 Resolved
Vessel's time since original drydock on Caribbean Cargo Ship Safety Certificate if more than five years.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2009
Resolution: Vessel underwent drydock in Jones boat yard and had CCSSC certificate modified to reflect period of drydocks.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 11 January 2009 Resolved
Provide liscense and endorsement for new engineering officer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2009
Deck/Cargo › Holds/Tanks › Hatch
Issued 11 January 2009 Resolved
Securing arrangements for hatch coverings are wasted.
Action required: 705 - Other - as specified
Due 13 February 2009
Resolved 30 November 2009
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 24 November 2008 Resolved
Provide flag state endorsement for cheif mate.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2008
Resolved 24 November 2008
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 29 September 2008 Resolved
Owner/operator has not received required authorization to operate on the navigable waters of the U.S. Nontank Vessel Response plans must meet the required elements IAW 33 USC 1321(j)(5)(D) for each Geographic Specific Area in which it operates.
Action required: 705 - Other - as specified
Due 29 October 2008
Resolved 3 April 2013
Resolution: Deficiency cleared due to change in name, owner, flag and subsequent exam.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 28 May 2008 Resolved
MDE IS INOPERABLE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2008
Resolution: MDE tested sat.
Engineering › Generator (propulsion-electric) › Generator Voltage Regulator Circuitry
Issued 28 May 2008 Resolved
SSDG is inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2008
Resolution: Replacement generator has been installed and is satisfactorily connected to ship''s electrical system.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 May 2008 Resolved
Emergency Generator does not have safety guards.
Action required: 705 - Other - as specified
Due 21 July 2008
Resolved 23 July 2008
Resolution: Guards have been replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 September 2007 Resolved
Electrical and mechanical safety hazards exist with the emergency generator and the surrounding area. Exposed wires and proper guards are not in place for crew safety. The battery is not properly housed in a suitable location to prevent it from corrosion and the outdoor elements.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2007
Resolution: def corrected
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 17 September 2007 Resolved
Bridge steering rudder angle indicator is 7 degrees off starboard and 4 degrees off port from steering gear room RAI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2007
Resolution: Def corrected
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 September 2007 Resolved
OWS does not work and/or crew is unfamiliar with operating procedures. USCG was unable to verify if OWS worked properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2007
Resolution: Def corrected
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 17 September 2007 Resolved
SOPEP needs to be updated to reflect a current 24 contact list.
Action required: 705 - Other - as specified
Due 18 October 2007
Resolved 13 November 2007
Resolution: Def corrected
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 17 September 2007 Resolved
Emergency Fire pump does not have pressure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2007
Resolution: Def corrected
Operations/Management › Pollution › Report of Discharge
Issued 17 September 2007 Resolved
Oil Record Book is not being maintained properly and is not being updated on a regular basis.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2007
Resolution: Def corrected
Fire Fighting › Fire Pumps › Pressure
Issued 17 September 2007 Resolved
Main fire pump does not have PSI gauges directly affecting the fire hoses max. allowance of working pressure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2007
Resolution: Def corrected
Personnel › Training › Diesel Engineering
Issued 17 September 2007 Resolved
Chief Engineer is unfamiliar with engineering spaces, duties and general ISM procedures including addressing non-conformities to the Captain of the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2007
Resolution: Def corrected
Engineering › Generator (propulsion-electric) › Switch
Issued 17 September 2007 Resolved
Ventilation for the Generator Space is not working. Associated vents are corroded, pitted and worn.
Action required: 705 - Other - as specified
Due 18 October 2007
Resolved 13 November 2007
Resolution: Def corrected
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 17 September 2007 Resolved
Vessel has had a Flag change, operator company is required to contact NPFC to report the change.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2007
Resolution: Def corrected
Fire Fighting › Fire Main › Condition
Issued 17 September 2007 Resolved
Permanently repair holed firemain on portside. Firemain currently has a 2"--3" hole. This directly effects the main and emergency fire hose MAWP.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2007
Resolution: Def corrected
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 20 March 2007 Resolved
Cracked cylinder head causing leaking jacket-water in the lube oil sump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2007
Lifesaving › Rescue Boat › Propulsion Engine
Issued 13 February 2007 Resolved
Rescue boat motor is inoperable. Motor is currently being repaired.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2007
Resolved 18 March 2007
Resolution: Recieved Survey report from [name withheld] attesting to proper repair to rescue boat motor.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 13 February 2007 Resolved
Chief engineer could not provide a reciept of application or valid Antigua endorsement.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2007
Resolved 20 February 2007
Communications › Alarms/Indicators › Rate of Turn Indicator
Issued 13 February 2007 Resolved
RPM gauge on main engine missing, exposing wiring.
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 18 March 2007
Resolution: Recieved report from [name withheld] attesting to proper replacement/repair/testing to RPM gauge on main engine.
Electrical › Electric Generation Source (emergency) › Generator
Issued 16 August 2005 Resolved
Emergency generator inoperable. Make proper repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2005
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 16 August 2005 Resolved
Vessel is required to have an ISM system on board and to have ISM SMC and DOC. Vessel must obtain these certificates prior to returning to US waters after sailing foreign
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2005
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 16 August 2005 Resolved
Vessel does not have a copy of the ISM Document of Compliance on board. Vessel must obtain a copy of this certificate prior to returning to US waters after sailing foreign
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2005
Navigation › Piloting/Steering › Marine Charts
Issued 16 August 2005 Resolved
VSL doesnt have current edition of mautical charts on board. Replace all charts correct w/ notice to mariners
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2005
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 16 August 2005 Resolved
Update deviation table
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2005
Navigation › Piloting/Steering › Notices to Navigation
Issued 16 August 2005 Resolved
Navtex inoperable
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2005
Lifesaving › Lifeboat Equipment › Radio (fixed two-way VHF radio-telephone)
Issued 16 August 2005 Resolved
GMDSS Lifeboat radios inoperable (2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2005
Communications › Radio Communications › Emergency Source of Power
Issued 16 August 2005 Resolved
Power supply to GMDSS is not charging the batteries
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2005
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 16 August 2005 Resolved
Line throwing appratus has expired charges
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2005
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 16 August 2005 Resolved
Excessive oily water in the bilges. Reomove o/w via an approved reception facility and fax proof of report to USCG .
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2005
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 16 August 2005 Resolved
Vsl not manned iaw safe manning certificate- missing chief engineer
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 2 December 2004 Resolved
Portside Nav light bulb is improper.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2004
Resolution: Bulb was replaced with proper one.
Fire Fighting › Fire Main › Condition
Issued 2 December 2004 Resolved
Wasted and Holed firemain pipeing located Amidships portside.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2004
Resolution: Pipe was repaired and tested in presence of flag representitive.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 2 December 2004 Resolved
Missing flagstate endosements for master, Chiefmate and Chief engineer.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2004
Resolution: Master presented flagstate endorsement applications for the Master Chief Mate, and Chief Engineer.
Fire Fighting › Fire Pumps › Pressure
Issued 2 December 2004 Resolved
Fire main pressure is low. Charged fire hose can be depressed by hand. CCSSC 3.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2004
Fire Fighting › International Shore Connection › Washers
Issued 2 December 2004 Resolved
04 washers missing from International Shore Connection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2004
Deck/Cargo › Cargo Stowage › General
Issued 2 December 2004 Resolved
Improper stowage of flammables, corressives, and batteries on main deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 2 December 2004 Resolved
STBD Side spotlight glass cover missing iwo top portion of bridge.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 December 2004
Engineering › Lubricating Oil Service System › Piping
Issued 2 December 2004 Resolved
Leaking hydrolic line/piping on port side iwo firemain piping
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 December 2004
Resolved 7 December 2004
Personnel › Certificates/Documents/Licenses
Issued 4 May 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2004
Lifesaving › Inflatable Liferafts
Issued 4 May 2004 Resolved
Current liferaft arrangement is not float free. Change liferaft arrangement to make liferafts float free. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2004
Fire Fighting › Fire Main
Issued 4 May 2004 Resolved
Firemain is wasted and holed on anchor windlass deck. Make permanent/proper repairs to holed firemain. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2004
Electrical › Electrical Distribution System (service)
Issued 4 May 2004 Resolved
Reefer located on aft boat deck is improperly stowed (freezer is sitting on milk crates) and powered by an extension cord. Properly secure/stow reefer make wiring instilation permanent. LEGACY COMPONENT DESC: Wiring
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2004
Resolution: Reefer now has metal brackets holding it in and they are welded to the deck.
Engineering › Sea-water System (primary cooling)
Issued 4 May 2004 Resolved
Hole in main diesel engine between strainer housing and aft mounting flange pipe. Make permanent and proper repairs to pipe and flange. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2004
Stability › Watertight Integrity
Issued 4 May 2004 Resolved
Bolt in ballast pipe. Make permanent repairs by cropping and renewing pipe. LEGACY COMPONENT DESC: Ballast Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2004
Stability › Watertight Integrity
Issued 4 May 2004 Resolved
Hole in uptake space stbd side around main diesel engine in ship service generator crankcase exhaust pipes. Make permanent and proper repairs to make uptake space watertight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2004
Operations/Management › Vessel Safety Management
Issued 4 May 2004 Resolved
Prior to commencement of any and all hotwork in the vicinity of machinery space and uptake space, provide a Marine Chemist Gas Free Certificate to MSO Miami. LEGACY COMPONENT DESC: Marine Chemist Certificate
Action required: 705 - Other - as specified
Due 5 May 2004
Resolved 27 May 2004
Personnel › Manning/Qualifications
Issued 9 December 2003 Resolved
Properly manned vessel in accordance with Minimum Safe Manning Certificate. Master license expried and no endorsement, Assistant Chief Engineer license fraudalent, Cook training certificates fraudalent and the rest of the officers required Flag endorsements. No cargo ops. CCSSC 1.7 LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2004
Construction/Loadline › Markings
Issued 9 December 2003 Resolved
Properly affix load line markings in accordance with the Load Line Certificate. Provide class survey report. LEGACY COMPONENT DESC: Load Line Mark
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2004
Electrical › Electrical Distribution System (service)
Issued 9 December 2003 Resolved
Install proper wiring on freezer aft of bridge deck. CCSSC 2.26.1 LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 9 January 2004
Resolved 12 January 2004
Construction/Loadline › Structures
Issued 9 December 2003 Resolved
Provide dogs for #1 Cargo Hatch to make watertight in accordance with Load Line Certificate. Prior to cargo ops and departure. Provide class survey report. CCSSC 2.7 LEGACY COMPONENT DESC: Manhole
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2004
Electrical › Electric Generation Source (service)
Issued 9 December 2003 Resolved
Repair main generator and provide class survey report. No cargo ops. CCSSC 2.26.1 LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2004
Operations/Management › Navigation Safety
Issued 9 December 2003 Resolved
Complete all items addressed by class on 25 Aug 2003 related to thickness measurements and internal inspections to do list. Total of 13 items issued. No cargo ops.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2004
Operations/Management › Casualty Reporting/Post-Casualty Actions
Issued 9 December 2003 Resolved
Vessel failed to notify the nearest Coast Guard Marine Safety Office of a hazardous conditions in accordance with 33 CFR 160.215. Vessel entered US waters with inop Main Diesel Generator using the emergency generator since 28 Nov 2003. LEGACY COMPONENT DESC: Report of Potential Vessel Casualty
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2004
Construction/Loadline › Structures
Issued 9 December 2003 Resolved
Vessel's superstructure has a 2' X 3' wooden insert. Permanently repair with a steel insert prior to departure. LEGACY COMPONENT DESC: Superstructure
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2004
Resolved 21 January 2004
Pollution Prevention/Response
Issued 9 December 2003 Resolved
Bilges have 2' of oily water in the Engine Room. Remove oily water from bilges prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2004
Resolved 21 January 2004
Engineering › Generator (propulsion-electric)
Issued 9 December 2003 Resolved
Main generator has an exhaust leak. Repair.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2004
Resolved 21 January 2004
Personnel › Certificates/Documents/Licenses
Issued 9 December 2003 Resolved
Provide proof of application for flag State endorsements to licenses for all officers. LEGACY COMPONENT DESC: STCW Endorsement
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2004
Resolved 21 January 2004
Personnel › Manning/Qualifications
Issued 10 June 2003 Resolved
Provide Flag State Endorsements for entire crew onboard.
Due 11 August 2003
Resolved 20 August 2003
Resolution: Attended vsl rcvd a copy of endorsement from Antigua & Barbuda W.I
Lifesaving › Inflatable Liferafts
Issued 10 June 2003 Resolved
Liferaft (port and stbd) float-free arrangements obstructed by handrails and overhead canopy. LEGACY COMPONENT DESC: Container Construction
Due 10 July 2003
Resolved 20 August 2003
Resolution: Attended vsl liferaft found to be in good shape.
Deck/Cargo
Issued 10 June 2003 Resolved
Oxygen Cylinders Stowed Improperly on deck. Needs to be removed or have brackets installed. LEGACY COMPONENT DESC: Oxygen Cylinders Stowed Improperly
Due 10 July 2003
Resolved 20 August 2003
Resolution: Cylinders found stowed fwd of House with bracket installed
Electrical › Lighting (service)
Issued 10 June 2003 Resolved
Paint locker has improperly installed light fixtures and cables.
Due 10 July 2003
Resolved 20 August 2003
Resolution: proper lights installed in paint locker
Deck/Cargo
Issued 10 June 2003 Resolved
Paint storage box located aft of deck house not properly installed. LEGACY COMPONENT DESC: Paint Storage Box
Due 10 July 2003
Resolved 20 August 2003
Resolution: Vsl installed vent holes both fwd/rear of box
Construction/Loadline › Markings
Issued 10 June 2003 Resolved
Loadline/deck line not properly marked. LEGACY COMPONENT DESC: Load Line Mark
Due 10 July 2003
Resolved 20 August 2003
Resolution: Vsl has proper marks on side of vsl
Personnel › Manning/Qualifications
Issued 9 October 2002 Resolved
Man vessel IAW minimum safe manning document. Master is missing flag state endorsement or transitory and missing one certificated able body seaman. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 17 - Rectify deficiencies prior to departure
Due 9 October 2002
Resolved 29 October 2002
Personnel › Certificates/Documents/Licenses
Issued 9 August 2002 Resolved
Man vessel IAW safe manning certificate. Provide STCW certificate for 1 A/B. LEGACY COMPONENT DESC: STCW Endorsement
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2002
Resolved 13 August 2002
Personnel › Training
Issued 9 August 2002 Resolved
Provide proof of HAZMAT training for [name withheld] training for crew or remove HAZMAT, including vehicles. LEGACY COMPONENT DESC: HAZMAT
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2002
Resolved 28 January 2024
Resolution: Vessel sunk; clearing open deficiency.
Deck/Cargo › Cargo Stowage
Issued 9 August 2002 Resolved
Remove cargo to allow access to all fire stations and safety/lifesaving gear. Remove cargo near fire station, port side FWD.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2002
Resolved 9 August 2002
Deck/Cargo › Cargo Stowage
Issued 9 August 2002 Resolved
Adjust cargo to meet bridge visability regs in SOLAS V/22.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2002
Resolved 13 August 2002
Documentation › Manifests/Lists
Issued 9 August 2002 Resolved
Provide proper stowage, shipping papers and DCM for propane tanks or remove them from vessel. In carrying HAZMAT provide proper DCM IAW 49CFR176.30 and Shipping Papers IAW 49CFR176.24. LEGACY COMPONENT DESC: Dangerous Goods Manifest/Stowage Plan
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2002
Resolved 16 August 2002
Resolution: vsl removed all hazmat from vsl
Documentation › Safety/Response Plans/Programs
Issued 20 March 2002 Resolved
Update SOPEP (ships interests, contacts and particulars) andhave administration approve it. LEGACY COMPONENT DESC: SOPEP
Action required: 705 - Other - as specified
Due 20 April 2002
Resolved 6 April 2002
Resolution: Cleared def.
Documentation › Manuals/Policy Documentation
Issued 20 March 2002 Resolved
Update crew training manual and provide in language of all crew members (most speak Spanish, some speak English). LEGACY COMPONENT DESC: Training Manual (lifesaving)
Action required: 705 - Other - as specified
Due 20 April 2002
Resolved 6 April 2002
Resolution: Cleared def.
Accommodation/Occupational Safety › Occupational Safety
Issued 20 March 2002 Resolved
Repair Port side rails that were damaged in collision with a vessel in Haiti. LEGACY COMPONENT DESC: Deck Rail
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2002
Resolved 6 April 2002
Resolution: Cleared def.
Navigation › Piloting/Steering
Issued 20 March 2002 Resolved
Provide "Notice to Mariners" and update all charts and publications. LEGACY COMPONENT DESC: Marine Charts
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2002
Resolved 6 April 2002
Resolution: Cleared def.
Engineering › Steering Gear System
Issued 20 March 2002 Resolved
Re-adjust rudder angle indicators (bridge and emergency steering (ie rudder stock) show a 5 degree difference). LEGACY COMPONENT DESC: Rudder Angle Indicator
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2002
Resolved 6 April 2002
Resolution: Cleared def.
Engineering › Sea-water System (primary cooling)
Issued 20 March 2002 Resolved
Repair water cooling line on MDE, port side of engine. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2002
Resolved 6 April 2002
Resolution: Cleared def.
Engineering › Generator (propulsion-electric)
Issued 20 March 2002 Resolved
Repair Diesel and water leaks on starboard generator. LEGACY COMPONENT DESC: leaking oil/water
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2002
Resolved 6 April 2002
Resolution: Cleared def.
Fire Fighting › Fire Main
Issued 20 March 2002 Resolved
Repair leaks in fire/ballast water lines in engine room. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2002
Resolved 6 April 2002
Resolution: Cleared def.
Pollution Prevention/Response › Prevention Equipment
Issued 20 March 2002 Resolved
Secure starboard side heads immediately, that bypass sewage system (MSD Type III) leading directly overboard. Three of the heads onboard were discharging directly overboard. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Action required: 705 - Other - as specified
Due 20 March 2002
Resolved 6 April 2002
Resolution: Vsl secured all toilets with direct access to overboard discharge valve.
Accommodation/Occupational Safety › Occupational Safety
Issued 20 March 2002 Resolved
Provide guards on moving parts on main steering motor. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 20 April 2002
Resolved 6 April 2002
Resolution: Cleared def.
Electrical › Lighting (service)
Issued 20 March 2002 Resolved
Provide/repair/replace lights and fixtures in engine room. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 20 April 2002
Resolved 6 April 2002
Resolution: Cleared def.
Lifesaving › Inflatable Liferafts
Issued 20 March 2002 Resolved
Show proof liferafts were annually serviced. LEGACY COMPONENT DESC: Servicing
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2002
Resolved 6 April 2002
Resolution: Cleared def.
Deck/Cargo › Mooring/Anchoring
Issued 20 March 2002 Resolved
Repair excessive water leak on anchor wash piping. LEGACY COMPONENT DESC: Anchor wash piping
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2002
Resolved 6 April 2002
Resolution: Cleared def.
Personnel › Certificates/Documents/Licenses
Issued 20 March 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2002
Resolved 6 April 2002
Resolution: Cleared def.
Documentation › Manuals/Policy Documentation
Issued 20 March 2002 Resolved
Update Oil Transfer Procedures to include transfers of lube oil IAW 33 CFR 155.720. LEGACY COMPONENT DESC: Transfer Procedures
Action required: 703 - Prior to bunkering operations
Due 20 March 2002
Resolved 24 April 2002
Documentation › Manuals/Policy Documentation
Issued 20 March 2002 Resolved
Provide ballast water management plan onboard. LEGACY COMPONENT DESC: Ballast water management plan
Action required: 705 - Other - as specified
Due 20 April 2002
Resolved 20 April 2002
Resolution: Not required.
Operations/Management › Drills/Instruction
Issued 20 March 2002 Resolved
Submit to USCG fire and abandon ship drills. LEGACY COMPONENT DESC: abandon ship and fire
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2002
Resolved 21 March 2002
Resolution: Observed satisfactory fire and abandon ship drills.
Documentation › Logs/Records
Issued 20 March 2002 Resolved
Have class/flag state provide survey report attesting to completion of ALL prior to departures. LEGACY COMPONENT DESC: Survey report
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2002
Resolved 6 April 2002
Resolution: Cleared def.
Navigation
Issued 26 August 1998 Resolved
MAGNETIC COMPASS DEVIATION CARD OUDATED (4/96).
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Documentation
Issued 16 May 1996 Resolved
Ships certificates must be updated to show the correct gross tonnage. Vessel's tonnage recently changed from 499 to 1167 GT as per Ships Registryand ITC Certificates. Annual endorsements must be updated as required by Solas and Marpol.
Condition: Unknown
Due 27 August 1998
Resolved 27 August 1998
Fire Fighting
Issued 25 April 1996 Resolved
Fire main wasted,(main deck run had pin hole leaks)._x001C_ Citation: SOLAS 60 II/56(e)
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Documentation
Issued 6 May 1993 Resolved
FAILURE TO PROVIDE OIL TRANSFER PROCEDURES FOR A VESSEL WHICH HAS A CAPACITY OF 250 OR MORE BARRELS OF OIL OR HAZARDOUS MATERIAL.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Navigation
Issued 6 May 1993 Resolved
A VESSEL, OF 12 METERS OR MORE IN LENGTH, DID NOT HAVE ON BOARD A COPY OF THE INLAND NAVIGATION RULES.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Documentation
Issued 6 May 1993 Resolved
A SHIP, OF 26 FEET OR MORE IN LENGTH, DID NOT HAVE A DISCHARGE OF OIL PROHIBITED PLACARD.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Accommodation/Occupational Safety
Issued 6 May 1993 Resolved
OPERATION OF VESSEL IN THE INLAND OR COASTAL WATERS OF THE UNITED STATES WITH A TYPE III MARINE SANITATION DEVICE WHICH FAILED TO PREVENT THE OVERBOARD DISCHARGE OF RAW, UNTREATED SEWAGE.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Documentation
Issued 6 May 1993 Resolved
FAILURE TO PROPERLY FILL OUT, AND SIGN A DECLARATION OF INSPECTION PRIOR TOCONDUCTING OIL TRANSFER OPERATIONS.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.