MAURY USCG vessel records Sign in
← All vessels

CMS ENERGY

CMS ENERGY is a 1985 offshore supply vessel. The Coast Guard has recorded 52 inspections since 1985, most recently in October 2006, along with 21 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2006.

Records from 1985 to 2006. Most recent: inspection, 27 October 2006.

Built
1985
Last inspected
27 October 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8216435 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCR7055
249574
Flag
UNITED STATES
366636000 (licence lapsed)
Maury page id
psix-249574

Inspections, by type

…with no type recorded9
Years with a record 22 calendar years (1985–2006)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it483 - Regulatory (Subpart C or D), Gross Ton
999 - Convention (Subpart B), Gross Ton
1155 - Dead Weight, Ton
329 - Regulatory (Subpart C or D), Net Ton
299 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCR7055MMSI 366636000 · cancelled · compulsorily equipped · granted 20 April 2005, cancelled 9 August 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 52

27 October 2006 Hull Examination · Damage Survey · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2809287
11 August 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2743811
14 May 2006 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2648840
13 May 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2648658
23 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571488
23 August 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2472100
4 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303704
10 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290219
1 November 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232690
30 September 2004 Internal Structural Exam · Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2163492
16 June 2004 Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2100032
7 June 2004 MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2066508
26 May 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2079201
16 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1967011
20 November 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1951670
23 September 2003 Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1911217
26 April 2002 Annual Inspection · MARPOL Annex I Examination · Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1609670
21 June 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066962
2 June 2001 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1413956
18 August 2000 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 823775
12 June 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1373075
21 December 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 60197
2 June 1999 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404767
16 April 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1122888
3 June 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459414
28 September 1997 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 782628
17 June 1997 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1111609
15 April 1997 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1334851
21 June 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413006
28 April 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431524
15 December 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1164042
4 September 1994 Excursion Permit
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 863018
10 May 1994 Deficiency Check · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1410972
7 May 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 60286
5 May 1994 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450850
4 October 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141226
2 June 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 840175
2 May 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449596
23 June 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 221485
18 May 1992 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440629
30 July 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 646244
6 May 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 903641
11 February 1991 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 926325
9 February 1991 Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899851
2 July 1990 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 916574
12 May 1989 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1196338
20 April 1988 MARPOL Annex II Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1341541
2 June 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1335084
1 May 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001849
10 February 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013833
26 June 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990432
30 April 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 983849

Deficiency record · 21

Stability › Unintentional Flooding › General
Issued 14 May 2006 Resolved
Vsl struck underwater obstruction & is hard aground. Vsl flooding in bow thruster room & shaft alley; engine room taking on water; main deck galley & accomodations flooding. Empty #2 Fuel tank flooding. Vsl listing slightly to port.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 May 2006
Resolved 18 May 2006
Resolution: Vsl successfully refloated by salvors and in drydock at C-Port3 in Port Fourchon, LA, for temporary repairs.
Construction/Loadline › Hull › Hull Plating
Issued 14 May 2006 No resolution recorded
Vessel sustained bottom damage due to grounding outside of channel in Belle Pass, Fourchon.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 23 August 2005 Resolved
Submit Automation test procedures with correct test results for approval.
Condition: Unknown
Due 23 September 2005
Resolved 25 August 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 August 2005 Resolved
Make repairs and show proper operation of navigational lights and panel.
Condition: Improper/Lack of Maintenance
Due 31 August 2005
Resolved 25 August 2005
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 23 August 2005 Resolved
Provide additional firemans outfit.
Condition: Unknown
Due 23 September 2005
Resolved 25 August 2005
Pollution Prevention/Response › Prevention Equipment
Issued 26 April 2002 Resolved
Oily Water Separator proper operation was not demonstrated. No alarms or automatic stopping device. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2002
Resolved 30 April 2002
Resolution: Replaced OWS with new unit. Performed operational test.
Electrical
Issued 2 June 2001 Resolved
REPLACE ELECTRICAL WIRING RUNS TO STAR AND PORT TUGGER WINCH MOTORS.
Condition: Unknown
Due 1 September 2001
Resolved 26 April 2002
Resolution: Wires replaced.
Navigation
Issued 2 June 2001 Resolved
REPAIR GMDSS AND TEST IN ACCORDANCE WITH FACTORY MANUAL.
Condition: Unknown
Due 1 July 2001
Resolved 26 April 2002
Resolution: GMDSS repaired and tested.
Construction/Loadline
Issued 2 June 2001 Resolved
CROP AND RENEW WASTED AFTER PILOT HOUSE WINDOW FRAMING. REGASKET AS NECESSARY.
Condition: Unknown
Due 15 April 2002
Resolved 26 April 2002
Resolution: Window framing replaced and new windows installed.
Deck/Cargo
Issued 2 June 2001 Resolved
RANGE BOTH ANCHOR CHAINS AND REPLACE AS REQUIRED.
Condition: Unknown
Due 15 April 2002
Resolved 26 April 2002
Resolution: Both anchor chains replaced.
Navigation
Issued 12 June 2000 Resolved
MAKE PROPER REPAIRS TO RUDDER POTENTIOMETERS TO ENSURE RUDDERS STOP ELECTRICALLY VICE HARD STOPPING.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Navigation
Issued 12 June 2000 Resolved
MAKE PROPER REPAIRS TO AUTO-TRANSFER SWITCH FOR BRIDGE RADIOS. ETC. GMDSS
Condition: Unknown
Due 12 July 2000
Resolved 23 June 2000
Fire Fighting
Issued 12 June 2000 Resolved
PROVIDE B-III/B-IV/B-V SEMIPORTABLE FIRE EXTINGUISHER FOR ENGINEROOM. ADD LOCATION OF EXTINGUISHER TO FIRE AND SAFETY PLAN.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Fire Fighting
Issued 12 June 2000 Resolved
UPDATE FIRE AND SAFETY PLAN AND SUBMIT TO MSO NEW ORLEANS FOR APPROVAL. ENSURE SEMI-PORTABLE EXTINGUISHER IS ADDED.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Documentation
Issued 12 June 2000 Resolved
PROVIDE COPY OF MATES GMDSS PAPERS.
Condition: Unknown
Due 12 June 2000
Resolved 23 June 2000
Construction/Loadline
Issued 15 April 1997 Resolved
REPAIR BILGE ALARM IN THE STEERING COMPARTMENT. UNTIL BILGE ALARM IS REPAIRED HOURLY CHECKS ARE TO BE MADE OF THE STEERING COMPARTMENT WHILE UNDERWAY.
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Documentation
Issued 21 June 1996 Resolved
PROVIDE ON BOARD VESSEL RESPONSE PLAN FOR OIL AS SECONDARY CARGO, APPROVED BY USCG HEADQUARTERS.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Engineering
Issued 5 May 1994 Resolved
PROVE OPERATION OF OILY WATER SEPERATOR TO SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Deck/Cargo
Issued 2 May 1993 Resolved
MAKE DRY BULK TANKS AVAILABLE FOR INTERNAL INSPECTION NOT LATER THAN NEXT DRYDOCK EXAM.
Condition: Unknown
Due 2 May 1993
Resolved 2 May 1993
Engineering
Issued 2 May 1993 Resolved
PROVIDE ON BOARD APPROVED COPY OF ENGINEERING AUTOMATED CONTROL / MONITORING SYSTEM TESTING PROCEDURE.
Condition: Unknown
Due 2 May 1993
Resolved 2 May 1993
Deck/Cargo
Issued 1 May 1987 Resolved
PRIOR TO LOADING CALCIUM BROMIDE OR ANY OTHER NOXIOUS FLUID, PROVIDE ON BOARD A CARGO RECORD BOOK (CG4602B) AS REQUIRED BY MARPOL 73/78 ANNEX II.
Condition: Unknown
Due 1 May 1987
Resolved 1 May 1987

Casualty record · 1

13 May 2006Major Marine Casualty · role: Involved in a Marine Casualty · activity 2648658
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SEACOR ENERGY (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.