SHINNECOCK BELLE
SHINNECOCK BELLE is a 1985 freight ship. The Coast Guard has recorded 27 inspections since 1985, most recently in February 2012, along with 4 deficiencies and 1 operational control.
Records from 1985 to 2012. Most recent: inspection, 13 February 2012.
- Built
- 1985
- Last inspected
- 13 February 2012
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8312722 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
DY1H
249585
Flag
PHILIPPINES
—
Maury page id
psix-249585
Inspections, by type
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it22342 - Convention (Subpart B), Gross Ton
37451 - Dead Weight, Ton
45098 - Displacement, Ton
12775 - Convention (Subpart B), Net Ton
37451 - Dead Weight, Ton
45098 - Displacement, Ton
12775 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 27
13 February 2012
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4237660
16 September 2011
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4140246
22 December 2008
ISPS I Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3382216
7 November 2008
ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · STCW 95 Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3353868
19 January 2007
Type not recorded
No type recorded · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 2858504
17 April 2006
NPV Safety Exam · ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2626356
3 April 2006
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2615589
18 July 2005
Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2430678
24 November 2004
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2247300
20 October 2002
Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1692750
16 October 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1691980
22 April 2002
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1607806
19 April 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 289437
16 January 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 273719
26 February 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 425958
24 November 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 409915
29 April 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 390708
12 November 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 371902
13 September 1993
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 360643
28 September 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 353409
13 November 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 347077
3 May 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 343457
29 June 1990
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 337909
11 May 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 323227
3 December 1987
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 319966
24 March 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 529606
28 May 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 302149
Deficiency record · 4
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 September 2011
Resolved
0950 - Electric Equipment In General - After any survey of the ship no change shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey, without the sanction of the Administration. PSCO observed a recently installed welding machine in Bosun stores. Provide documentation attesting to proper installation of welding machine.
SOLAS 74a, I-11
Engineering › Freshwater Generation System
Issued 22 April 2002
Resolved
Leak in piping on discharge side of G/S pump. Secure water supply to pump until permanent repairs can made to satisfaction of class at vsl's drydock or NLT 30May02. If pump has to be used for ship operation, place live watch at site of leak. Temporary repair must be made to pipe prior to use.
Navigation
Issued 3 December 1987
Resolved
THE FOLLOWING CHARTS WERE NOT CURRENTLY CORRECTED AS REQUIRED BY 33 CFR 164.33(A)(1)(II): 1)16660 2)16640 3)16580
Documentation
Issued 3 December 1987
Resolved
OIL TRANSFER PROCEDURES DID NOT CONTAIN THE PRODUCTS GENERIC OR CHEMICAL NAME AND DID NOT HAVE THE CARGOE INFORMATION AS DESCRIBED IN 33 CFR 154.310(A)(5)(II). AS REQUIRED BY 33 CFR 154.750(A)(1)(I)(II).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.