Records from 1985 to 2011. Most recent: inspection, 1 December 2011.
Inspection history · 44
1 December 2011
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4199382
5 August 2011
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4106144
2 August 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4102602
25 January 2011
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3932933
22 March 2010
PII Safety Exam · Administrative Inspection · Ballast Water Examination · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3700229
8 April 2009
PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3448476
4 April 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3446159
11 January 2008
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3123629
7 July 2007
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2986440
15 October 2006
NPV Safety Exam · Random ISPS/MTSA/PSC
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2800915
25 July 2006
MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2718037
28 March 2005
ISPS III Exam · PII Safety Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2321017
26 November 2004
MARPOL Annex I Examination · Loadline Exam · ILO-147 Exam · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2248115
9 January 2004
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1980142
8 January 2004
Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1979462
14 August 2002
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1661236
5 February 2002
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1484198
15 May 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 290047
17 May 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 277848
8 May 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 428466
31 March 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 427194
16 January 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 411865
16 June 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 94230
6 June 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 391903
23 March 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 376376
8 April 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 458411
30 March 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 366436
31 August 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 360355
12 September 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 353091
10 August 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 345237
16 March 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 498942
17 September 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 339335
20 July 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 338360
24 April 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 481500
2 November 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 326593
28 October 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 326493
2 May 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 441400
17 November 1987
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 319652
7 October 1987
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 318861
15 May 1987
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 505830
4 October 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 311788
7 March 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 476498
20 October 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 530861
28 May 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 302290
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 5 August 2011
Resolved
Laundry room has two ventilation openings without means of properly securing ventilation in case of fire. Correct to the satisfaction of Class. SOLAS (74) II-2 REG 4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 December 2011
Resolution: Received, reviewed and accepted proper documentation from [name withheld] stating that a complete survey has been done and all items are satisfactory. Photographic evidence of the repair was also provided; Photos are included in this activity.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 5 August 2011
Resolved
Fire Control Plan is not up to date, not legible, and has the previous ship's name. SOLAS 74 II-2 REG 40
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 December 2011
Resolution: Received, reviewed and accepted proper documentation from [name withheld] stating that a complete survey has been done and all items are satisfactory. Scan of the Lloyd''s approval stamp on the Fire Control Plan received; Scan is included in activity.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 8 April 2009
Resolved
Significant build-up of oil on deck behind the F.O. Separator Tank in the Purifier Space. Remove to the satisfaction of the attending Class Surveyor.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 May 2009
Resolution: Received report from class attesting to the satisfactory removal of the fuel oil separation tank. Deficiency cleared.
Engineering › Fuel Oil Service System › Piping
Issued 8 April 2009
Resolved
Oil-soaked lagging saturated on several pipes on MDE. Replace all affected insulation to the satisfaction of the attending Class Surveyor.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 May 2009
Resolution: Received class report attesting to the satisfactory replacement of lagging. Deficiency cleared.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 8 April 2009
Resolved
Materiel condition of lining inside incinerator is significantly failing. Verify as to whether or not wall lining must be replaced with attending Class Surveyor.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 May 2009
Resolution: Received class report attesting to the satisfactory repair of incinerator lining. Deficiency cleared.
Deck/Cargo › Cargo Refrigeration
Issued 14 August 2002
Resolved
Make permanent and proper repairs to the seawater intake line for the condenser in the refer machinery space. Pipe has rubber soft patch near elbow. To the satisfaction of the Administration prior to next US visit.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 14 January 2004
Resolution: Sea water intake pipe for condenser now repaired by welding and found to be ok.
Engineering › Steering Gear System
Issued 14 August 2002
Resolved
Install nonskid surface around steering flat.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 14 January 2004
Engineering › Sea-water System (primary cooling)
Issued 14 August 2002
Resolved
Make permanent and proper repairs to the seawater cooling discharge line at the elbow in the engine room. Pipe has several rubber patches near elbow. To the satisfaction of the Administration prior to next US visit. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 14 January 2004
Resolution: Cooling water discharge pip at elbow of the Aux engine cooler repaired by welding and found satisfactory.
Engineering › Lubricating Oil Storage/Transfer System
Issued 14 August 2002
Resolved
Crew has installed a pipe plug in the lube oil vent line in the engine room. Administration is to approve the installation of plug. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 14 January 2004
Resolution: The plug to lubrication oil vent installed by crew has been inspected and found to be in order
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 14 August 2002
Resolved
Found Halon cylinder discharge lever disconnect for the cylinder in the emergency generator space. Lever was reinstalled however pin needs to be in place so lever will not inadvertently come off again. To the satisfaction of the Administration prior to next US visit. LEGACY COMPONENT DESC: Control Valve
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 14 January 2004
Resolution: Halon no longer used and has been removed from the vessel.
Electrical › Lighting (service)
Issued 14 August 2002
Resolved
Properly install the wire that runs up along the fire main and in through air vent on the aft starboard side of the superstructure. Wire is for the flood light for the vessels insignia on the mast. To the satisfaction of the Administration prior to next US visit. LEGACY COMPONENT DESC: Lighting Feeder
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 14 January 2004
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 14 August 2002
Resolved
The discharge release for the Halon in paint locker is located in passageway behind a locked door leading from cargo deck. Door is to remain unlocked or relocate the Halon release handle to the weather deck. To the satisfaction of the Administration prior to next US visit. LEGACY COMPONENT DESC: Control Valve
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 14 January 2004
Resolution: Halon is no longer used and has been removed from the vessel.
Construction/Loadline › Structures
Issued 14 August 2002
Resolved
Administration to examine the cracks running up and out from the upper corners from the doors in the engine room and make proposal of repairs. One set of cracks is located in the doors leading into the service air compressor space. These cracks were approximately 12 inches long. LEGACY COMPONENT DESC: Door
Condition: Design Flaw
Action required: 15 - Rectify deficiencies by next port
Resolved 14 January 2004
Resolution: Cracks have been welded by Metallock do Brazil. on sept 1 & 2, 2002.
Construction/Loadline › Structures
Issued 14 August 2002
Resolved
The Administration is to examine the crack in the aft bulkhead of the paint locker and make proposal of repair. Prior to next US visit. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 14 January 2004
Resolution: Cracks have been welded by Metalock do Brasil on 1 & 2 Sept 2002
Operations/Management › Vessel Safety Management
Issued 14 August 2002
Resolved
Vessel is to provide proof to the US Coast Guard prior to 16AUG02 1300hrs that the list of nonconformities found during this exam has been sent to the Designated Person Ashore (DPA) and that the DPA has received the report. LEGACY COMPONENT DESC: Documentation Maintenance/Control
Action required: 17 - Rectify deficiencies prior to departure
Due 16 August 2002
Resolved 15 August 2002
Resolution: Received fax of notification to the DPA
Lifesaving
Issued 15 May 2001
Resolved
PROVIDE QUICK RELEASE ARRANGEMENT FOR LIFE RING ON BRIDGE, IAW SOLAS CHAP.III REG. 7.1.3 TO THE SATIFACTION OF CLASS NLT 01JUN01
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Lifesaving
Issued 15 May 2001
Resolved
GRABLINES ON LIFEBOATS TOO CLOSE TO PROPELLAR AND NOT MADE OF BOUYANT MATERIAL REPLACE LINES IAW SOLAS LSA CODE CHAP.IV REG. 4.4.7 TO THE SATISFACTION OF CLASS NLT 01JUN01
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Lifesaving
Issued 15 May 2001
Resolved
RUDDER STOCK WASTED AT BOTTOMS ATTACHMENT POINT AND BOTTOM HAND RAILS HAVE POOR REPAIRS, CANNOT SEE IF HULL BOLTS ARE INTACT ON RAIL MOUNTS. HAVE CLASS SURVEY AND SUBMIT FINDINGS TO USCG NY NLT 01JUN01.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Construction/Loadline
Issued 31 March 1999
Resolved
REMOVE OILY WATER FROM BILGE PRIOR TO RETURN TO US WATERS.
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Documentation
Issued 6 June 1996
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH HAZARDOUS MATERIAL, UN 1993, WITHOUT THE REQUIRED HAZMAT TRAINING IN ACCORDANCE WITH 49 C.F.R 172.702.
Condition: Unknown
Due 6 June 1996
Resolved 22 July 1996
Navigation
Issued 17 November 1987
Resolved
U.S. COAST PILOT NOT CURRENTLY CORRECTED WITH THE APPROPRIATE NTM'S.
Condition: Unknown
Due 17 November 1987
Resolved 17 November 1987
Navigation
Issued 7 October 1987
Resolved
U.S. CHARTS 11412, 11413, 11414 WHICH ARE REQUIRED FOR TRANSIT OF TAMPA BAYWERE NOT CURRENTLY CORRECTED WITH APPRORIATE NTM'S.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Navigation
Issued 7 October 1987
Resolved
INLAND NAVIGATION RULES NOT ONBOARD SUBJ VSL.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Navigation
Issued 7 October 1987
Resolved
U.S. COAST PILOT WAS NOT CURRENTLY CORRECTED, IT WAS ONLY CORRECTED THRU NTM 19/87.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987