Records from 1986 to 1994. Most recent: inspection, 3 March 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 25
3 March 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1165236
13 January 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 515061
13 January 1994
Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 851150
7 August 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 59628
6 August 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 519856
19 April 1993
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 832779
20 January 1993
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 831376
7 October 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 509026
21 April 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 350062
7 February 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 348320
6 February 1992
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1254669
8 May 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 344510
8 May 1991
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1201148
10 February 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 341775
9 January 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 341181
9 January 1991
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1218178
10 June 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 522701
8 December 1989
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 933296
17 September 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 516497
21 November 1988
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1207134
12 January 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 523218
19 June 1987
Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1005947
18 June 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 472528
28 February 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 307094
28 February 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1299623
Deck/Cargo
Issued 13 January 1994
Resolved
REPLACE MISSING BOLTS ON HYDRAULIC VALVE COVER ON #1 CARGO LINE PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Deck/Cargo
Issued 13 January 1994
Resolved
REPLACE WASTED BOLT ON BUTTERWORTH PLATE ON #5 STARBOARD CARGO TANK PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Construction/Loadline
Issued 20 January 1993
Resolved
ENTER BALLAST TANK FOR COMPLIANCE WITH MVI POLICY LETTER
Condition: Unknown
Due 20 January 1993
Resolved 20 January 1993
Construction/Loadline
Issued 6 February 1992
Resolved
AFTER DEWATERING FORWARD BOS'N STORES, MAKE AVAILABLE FOR INSPECTION BY_x001C_ USCG PRIOR TO DEPARTURE.
Condition: Unknown
Due 15 February 1992
Resolved 20 February 1992
Deck/Cargo
Issued 6 February 1992
Resolved
INSTALL 30X30 MESH FLAME SCREEN IN IGS MAST RISER VENT PRIOR TO DEPARTURE.
Condition: Unknown
Due 15 February 1992
Resolved 20 February 1992
Fire Fighting
Issued 6 February 1992
Resolved
MAKE PERMANENT REPAIRS TO FIRE STATION VALVE THAT LEAK BY WHEN CLOSED.
Condition: Unknown
Due 6 February 1992
Resolved 6 February 1992
Fire Fighting
Issued 6 February 1992
Resolved
MAKE PERMANENT REPAIRS TO FIREMAIN SHUT-OFF VALVES LEAKING BY ON #5 & #10_x001C_ FOAM MONITORS.
Condition: Unknown
Due 6 February 1992
Resolved 6 February 1992
Fire Fighting
Issued 8 May 1991
Resolved
TEMPORAY FIBERGLASS PATCHES ON FOAM MONITORS 5&6 INLET PIPING. SOLAS CH II-2 PART D REG 61. MAKE PERMANENT REPARIS TO DECK FOAM MAIN NLT 01SEPT91._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 May 1991
Resolved 8 May 1991
Navigation
Issued 9 January 1991
Resolved
HAVE BLOCK DIAGRAM AND INSTRICTIONS ON CHANGEOVER PIROR TO OPS IN U.S. WATERS.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Navigation
Issued 9 January 1991
Resolved
COAST PILOT ABOARD IS FROM 1985 WITHOUT CORRECTIONS. HAVE A CORRECTED COAST PILOT ONBOARD NLT 09FEB91._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Documentation
Issued 9 January 1991
Resolved
PLASTICS BEING DISPOSED OF OVERBOARD. RETAIN PLASTICS ABD/GET RECEITS FROM SHORESIDE RECEIPT FACILITY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Engineering
Issued 9 January 1991
Resolved
OWS SENSOR NOT PROPERLY ALARMING WHEN OIL PASSED THROUGH IT.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
ALL FLAME SCREENS FOR BUNKER TANKS HOLED.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Fire Fighting
Issued 9 January 1991
Resolved
FOAM MONITORS #3,#5, AND #6 INOP.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
IGS LOW PRESSURE TO DECK SEAL ALARMS INOPERATIVE. PROVE PROPER OPS PRIOR TO OPS IN U. S. WATERS.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
DEVCON TEMP PATCH ON VENT MAST PORT SIDE. MAKE PERMANENT REPAIRS TO VENT SYSTEM NLT 09FEB91
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
DEVCON TEMP PATCH ON DECK SEAL PLUS ACTUATING VALVE. MAKE PERMANENT REPAIRSTO IG SYSTEM NLT 09FEB91.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991