MAURY USCG vessel records Sign in
← All vessels

RHAPSODY

RHAPSODY is a 1977 tank ship. The Coast Guard has recorded 25 inspections since 1986, most recently in March 1994, along with 17 deficiencies.

Records from 1986 to 1994. Most recent: inspection, 3 March 1994.

Built
1977
Last inspected
3 March 1994
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7370662 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
249611
Flag
LIBERIA
—
Maury page id
psix-249611

Inspections, by type

…with no type recorded15
Years with a record 9 calendar years (1986–1994)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 32 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it64324 - Regulatory (Subpart C or D), Gross Ton
139527 - Dead Weight, Ton
51273 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 25

3 March 1994 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1165236
13 January 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 515061
13 January 1994 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 851150
7 August 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 59628
6 August 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 519856
19 April 1993 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 832779
20 January 1993 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 831376
7 October 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 509026
21 April 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 350062
7 February 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 348320
6 February 1992 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1254669
8 May 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 344510
8 May 1991 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1201148
10 February 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 341775
9 January 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 341181
9 January 1991 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1218178
10 June 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 522701
8 December 1989 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 933296
17 September 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 516497
21 November 1988 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1207134
12 January 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 523218
19 June 1987 Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1005947
18 June 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 472528
28 February 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 307094
28 February 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1299623

Deficiency record · 17

Deck/Cargo
Issued 13 January 1994 Resolved
REPLACE MISSING BOLTS ON HYDRAULIC VALVE COVER ON #1 CARGO LINE PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Deck/Cargo
Issued 13 January 1994 Resolved
REPLACE WASTED BOLT ON BUTTERWORTH PLATE ON #5 STARBOARD CARGO TANK PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Construction/Loadline
Issued 20 January 1993 Resolved
ENTER BALLAST TANK FOR COMPLIANCE WITH MVI POLICY LETTER
Condition: Unknown
Due 20 January 1993
Resolved 20 January 1993
Construction/Loadline
Issued 6 February 1992 Resolved
AFTER DEWATERING FORWARD BOS'N STORES, MAKE AVAILABLE FOR INSPECTION BY_x001C_ USCG PRIOR TO DEPARTURE.
Condition: Unknown
Due 15 February 1992
Resolved 20 February 1992
Deck/Cargo
Issued 6 February 1992 Resolved
INSTALL 30X30 MESH FLAME SCREEN IN IGS MAST RISER VENT PRIOR TO DEPARTURE.
Condition: Unknown
Due 15 February 1992
Resolved 20 February 1992
Fire Fighting
Issued 6 February 1992 Resolved
MAKE PERMANENT REPAIRS TO FIRE STATION VALVE THAT LEAK BY WHEN CLOSED.
Condition: Unknown
Due 6 February 1992
Resolved 6 February 1992
Fire Fighting
Issued 6 February 1992 Resolved
MAKE PERMANENT REPAIRS TO FIREMAIN SHUT-OFF VALVES LEAKING BY ON #5 & #10_x001C_ FOAM MONITORS.
Condition: Unknown
Due 6 February 1992
Resolved 6 February 1992
Fire Fighting
Issued 8 May 1991 Resolved
TEMPORAY FIBERGLASS PATCHES ON FOAM MONITORS 5&6 INLET PIPING. SOLAS CH II-2 PART D REG 61. MAKE PERMANENT REPARIS TO DECK FOAM MAIN NLT 01SEPT91._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 May 1991
Resolved 8 May 1991
Navigation
Issued 9 January 1991 Resolved
HAVE BLOCK DIAGRAM AND INSTRICTIONS ON CHANGEOVER PIROR TO OPS IN U.S. WATERS.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Navigation
Issued 9 January 1991 Resolved
COAST PILOT ABOARD IS FROM 1985 WITHOUT CORRECTIONS. HAVE A CORRECTED COAST PILOT ONBOARD NLT 09FEB91._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Documentation
Issued 9 January 1991 Resolved
PLASTICS BEING DISPOSED OF OVERBOARD. RETAIN PLASTICS ABD/GET RECEITS FROM SHORESIDE RECEIPT FACILITY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Engineering
Issued 9 January 1991 Resolved
OWS SENSOR NOT PROPERLY ALARMING WHEN OIL PASSED THROUGH IT.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991 Resolved
ALL FLAME SCREENS FOR BUNKER TANKS HOLED.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Fire Fighting
Issued 9 January 1991 Resolved
FOAM MONITORS #3,#5, AND #6 INOP.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991 Resolved
IGS LOW PRESSURE TO DECK SEAL ALARMS INOPERATIVE. PROVE PROPER OPS PRIOR TO OPS IN U. S. WATERS.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991 Resolved
DEVCON TEMP PATCH ON VENT MAST PORT SIDE. MAKE PERMANENT REPAIRS TO VENT SYSTEM NLT 09FEB91
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991 Resolved
DEVCON TEMP PATCH ON DECK SEAL PLUS ACTUATING VALVE. MAKE PERMANENT REPAIRSTO IG SYSTEM NLT 09FEB91.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.