MATTANZA
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named MATTANZA
MATTANZA is a 1985 passenger vessel (inspected). The Coast Guard has recorded 73 inspections since 1985, most recently in January 2025, along with 142 deficiencies — 3 with no resolution recorded —, 2 operational controls and 2 casualty investigations between 2019 and 2022.
Records from 1985 to 2025. Most recent: inspection, 8 January 2025.
- Built
- 1985
- Last inspected
- 8 January 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 142 recorded · 3 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2019–2022
Identity
684775
WDI 9340
249638
Flag
UNITED STATES
368222750
Maury page id
psix-249638
Inspections, by type
…with no type recorded5
…past their stated due date1
Years with a record
38 calendar years (1985–2025)
The 73 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)39.0 ft × 14.2 ft × 4.0 ft
Registered tonnagegross 15 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · KEY WEST, FL, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCORTEZ, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 30 June 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Net Ton
15 - Simplified, Gross Ton
15 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDM6165MMSI 368222750 · active · compulsorily equipped · granted 14 October 2021, expires 14 October 2031
WDI9340MMSI 369334000 · expired · compulsorily equipped · granted 22 July 2016, cancelled 29 August 2026
WSK8607MMSI not assigned · expired · voluntarily equipped · granted 10 April 1995, cancelled 11 June 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 73
8 January 2025
Drydock Exam · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8060057
3 June 2024
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7901349
9 August 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7764011
19 January 2023
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7625479
6 October 2022
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7559013
5 September 2022
Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7552696
5 September 2022
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7557858
30 August 2022
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7510314
10 September 2021
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7306376
9 September 2020
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7049269
1 September 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7071620
6 October 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6829732
6 October 2019
Damage Survey · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6830400
4 June 2019
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6703076
28 May 2019
COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6696587
4 October 2018
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6554573
16 August 2018
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6513950
19 October 2017
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6291609
24 August 2016
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5981661
19 July 2016
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5944631
14 July 2016
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5940605
26 August 2014
Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4965712
9 September 2011
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4139929
18 March 2010
Type not recorded
No type recorded · Station Ponce De Leon Inlet · USCG Southeast District (CGD-SE) · Activity 3702804
29 April 2009
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3464659
26 August 2008
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3309286
10 March 2008
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3161282
3 October 2007
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3071894
2 April 2007
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2890594
26 September 2006
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2786506
14 March 2006
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2602062
5 April 2005
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2326600
29 September 2004
Hull Examination · Internal Structural Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2232921
16 April 2004
Annual Inspection · Internal Structural Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2045514
29 October 2003
Internal Structural Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1939509
27 March 2003
Annual Inspection · Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1763695
9 December 2002
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1717199
28 October 2002
Internal Structural Exam · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1697269
1 April 2002
Periodic Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1600596
9 April 2001
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1471603
31 October 2000
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1467708
7 April 2000
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1426359
21 June 1999
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1193722
8 April 1999
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1369107
19 November 1998
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1463415
22 June 1998
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 791866
27 May 1998
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1126992
8 April 1998
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 788777
25 July 1997
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1115279
19 June 1997
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 776695
9 April 1997
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1102247
4 November 1996
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1165912
23 May 1996
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1082328
23 April 1996
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1080825
12 April 1996
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1079843
31 March 1995
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 835110
1 November 1994
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1172412
13 April 1994
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 860154
22 July 1993
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1152730
28 April 1993
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1145827
13 November 1992
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 960736
27 October 1992
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 953622
22 October 1992
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 949602
14 April 1992
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 955252
23 April 1991
COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 922649
1 May 1990
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1237307
2 November 1989
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1210268
9 May 1989
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 890203
6 May 1988
Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1037220
5 May 1987
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1334136
16 October 1986
Credit Drydock
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1009319
12 May 1986
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1295233
15 May 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 980061
Deficiency record · 142
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 April 2026
No resolution recorded
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is overdue for its first annual inspection. Vessel is restricted from operating with passengers until a satisfactory inspection is completed.
46 CFR 176.500
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 January 2025
No resolution recorded
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel's drydock inspection was due 31 OCT2024. Vessel has not completed its drydock. Vessel is restricted from operating with passengers until a drydock inspection is completed.
46 CFR 176.600
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 3 June 2024
Resolved
The Marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel representative could not provide testing devices on board the vessel.
46CFR185.212
46CFR4.06-15(a)
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 June 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 June 2024
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section. MI observed an unserviced 40-BC fire extinguisher and 3
inadequate 1-A type of others extinguishers. Operator
has until 7JUN24 to service the extinguisher on board.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 June 2024
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil. MI observed oil/slop accumulation in the bilge.
46CFR176.830
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 June 2024
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel representative did not have an available copy of the station license.
46CFR184.502
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 June 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 June 2024
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here:(ii) Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel did not have a monthly maintenance log for fire extinguishers.
46CFR176.810(b)(ii)
09 - Working and Living Conditions › 091 - Living Conditions › Record of inspection (Accommodation)
Issued 3 June 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. MI observed that the aspirin was expired.
46 CFR 184.710
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 August 2023
Resolved
The emergency fuel shut-off valve at the tank must be manually operable from outside the compartment in which the valve is located.
Starboard side fuel tank emergency fuel shut-off valve handle broke off while attempting to close due to excessive corrosion.
Repair/replace valve.
46 CFR 182.455(b)(4)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 August 2023
Resolved
Life float float-free link must be secured to the painter at one end and to the vessel on the other end.
Life float painter not secured to float-free link.
46 CFR 180.137(b)(3)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 August 2023
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light.
Floating waterlight inoperable.
Operations restricted to daylight only.
46 CFR 180.175(d)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 August 2023
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules.
Stern light inoperative.
Operations restricted to daylight only.
46 CFR 183.420
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 August 2023
Resolved
A pre-engineered fixed gas fire extinguishing system must have a means to shut off any ventilation to the space once system is actuated.
No means provided to secure vent ducts.
46 CFR 181.420(a)(3)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 August 2023
Resolved
The master and crew of a vessel will be familiar with the content of and and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions.
Emergency instructions do not contain the actions to plug machinery space ventilation in case of fire.
46 CFR 185.510(a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 August 2023
Resolved
A hatch exposed to the weather must be watertight.
Lazerette watertight hatch does not secure properly.
46 CFR 179.360(a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 August 2023
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy.
Lanyard not approved type nor approved length.
46 CFR 180.70(d)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 August 2023
Resolved
Each life buoy floating waterlight on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion resistant clip.
Clip is not corrosion resistant and is seized.
46 CFR 180.70(d)(3)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 August 2023
No resolution recorded
An interconnected detection and alarm system must be installed on board all vessels operating on a coastwise or oceans route and consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR subpart 159.010, as meeting UL 217 (incorporated by reference, see 46 CFR 175.600);
Vessel does not have interconnected fire detection and alarm system installed on board.
46 CFR 181.450(a)(2)
46 CFR 175.110(c)(2)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 August 2023
Resolved
On vessels described by 46 CFR 175.110(c), flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions.
There shall be one dedicated and labeled area where passenger/crew electronics can be charged.
46 CFR 185.364
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 August 2023
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil.
Excessive oil found in machinery space bilge.
46 CFR 176.830
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 November 2022
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
Vessel was due for drydock examination by October 31, 2022 and has yet to receive credit drydock exam.
46 CFR 176.600(c)(1)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 October 2022
Resolved
Vessel must meet the requirements of subchapter S. Each vessel that does not carry more than 49 passengers must have a collision bulkhead. The collision bulkhead may only have openings or penetrations if they are able to be made water tight.
The vessel has a large "inspection hole" in the center of the collision bulkhead with a cover that is not watertight. There are also wires that transit through the bulkhead via holes on the port side that were drilled through the bulkhead.
Vessels is restricted to Limited Coastwise rout (not more than 20 miles from safe harbor).
46 CFR 177.13-1 (Old-T)
46 CFR 171.040(b) (Old-T)
46 CFR 171.085(h)(3)(ii) (old-T)
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 October 2022
Resolved
A space containing propulsion machinery must be equipped with a fixed gas fire extinguishing system in compliance with 181.410.
The aft bulkhead in the engine compartment has several gaps and holes in it, allowing the gas from the installed fire-boy system to escape.
Vessel must make the wall air-tight within 7 days.
46 CFR 181.400(a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 6 October 2022
Resolved
Each hatch exposed to the weather must be watertight.
The hatch leading into the steering compartment has a wasted gasket with about a 4" gap on the STB side of the hatch, making the hatch not water tight.
46 CFR 171.124(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 September 2022
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
The master reported a loss of propulsion while underway.
Prove operation of the main engine to the satisfaction of the attending marine inspector.
46 CFR 182.05-1
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 August 2022
Resolved
Up-to-date charts and nautical publications of large enough scale to make safe navigation possible as appropriate for the intended voyage, must be carried onboard vessels.
MI found no local charts for intended voyages.
46 CFR 184.420(a)(1)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 August 2022
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected.
MI found a portable fire extinguisher located in a cabinet on the main deck not labeled as such.
46 CFR 181.520
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 30 August 2022
Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely.
MI found COI not posted.
46 CFR 176.302
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 30 August 2022
Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel.
MI found the stability letter not posted.
46 CFR 176.306
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 30 August 2022
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. MI found Life Float basket damaged.
Provide repair proposal.
46 CFR 180.175(a)
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 30 August 2022
Resolved
Each survival craft, rescue boat, and launching appliance on a vessel must be inspected monthly, using the manufacturer's instructions to make sure it is complete and in good order.
MI found no log of inspections.
46 CFR 185.722
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 August 2022
Resolved
Each ring life buoy on a vessel must, if on a vessel on an oceans or coastwise route, be orange in color.
MI found the life ring to be faded.
46 CFR 180.70(b)(5)
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 30 August 2022
Resolved
A vessel must carry one floating waterlight.
MI found the float light extinguished.
Vessel restricted to daylight operation only.
46 CFR 180.70(d)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 August 2022
Resolved
Each floating waterlight on a vessel carrying only one ring buoy must be attached to the lanyard with a corrosion-resistant clip.
MI found float light attached to life ring life buoy with a knot.
46 CFR 180.70(a)
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 30 August 2022
Resolved
The EPIRB's battery is shall be replaced before the date required by FCC regulations in 47 CFR part 80.
MI found EPIRB battery expired.
46 CFR 185.728(b)
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 30 August 2022
Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. Each hatch exposed to the weather must be watertight.
MI found the lazarette hatch seized and unable to be securely closed.
46 CFR 177.13-1
46 CFR 171.124(a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 August 2022
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.
MI found one type of life jacket onboard without proper donning instructions posted.
46 CFR 185.516(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 August 2022
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure and personnel injury.
MI found the fuel oil hose return manifold free of its original mounting.
46 CFR 182.100
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 September 2021
Resolved
The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway.
Vessel unable to start main propulsion engine. Vessel must prove proper operation.
46 CFR 176.404
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 September 2021
Resolved
The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant.
Floating waterlight on LF found to be inoperable.
46 CFR 180.175(f)(4)
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 10 September 2021
Resolved
The float-free link required by 180.139(a)(1) must be: (2)Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag.
Life float weak link is missing identification tag.
46 CFR 180.137(b)(2)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 September 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions.
First-aid kit is missing ammonia inhalants, eye wash, aspirin and burn cream.
46 CFR 184.710
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 10 September 2021
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies.
Vessel unable to conduct fire/abandon ship/man overboard drills due to vessels maintenance condition.
46 CFR 185.520(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 September 2021
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level.
All 3 visual water level indicators are burnt out/too dim to see.
46 CFR 182.530
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 September 2021
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests of the means provided for pumping bilges.
Bilge pumps unable to be tested due to engine status.
46 CFR 176.804(h)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 September 2021
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 9.5 liter (1.5 gallon) buckets, with an attached lanyard satisfactory to the cognizant [name withheld] 3rd fire bucket was missing lanyard.
46 CFR 181.610
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 September 2021
Resolved
In addition, a number of child size life jackets equal to at least 10% of the number of persons on board must be provided.
02 child size life-jackets found in need of repair or replacement. Vessel limited to carrying adult PAX only.
46 CFR 180.71(b)
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 10 September 2021
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio-beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80.
No DSC/MMSI available on VHF. Lat + Long was working.
46 CFR 184.502
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 October 2019
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements.
Make permanent repairs to propulsion machinery. Prove proper operation in presence of marine inspector.
IAW: 46 CFR 182.200
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 October 2018
Resolved
Replace all expired life jacket lights with current approved type lights. Restricted to daylight only operations. 46 CFR 180.75
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 October 2018
Resolved
Label location of fire extinguisher at operating station.
46 CFR 185.612
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 17 October 2018
Resolved
Provide current employee list from drug consortium. 46 CFR 16
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 17 October 2018
Resolved
Provide MIS report. 46 CFR 16.500
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 October 2018
Resolved
Portable fire extinguishers and installed fire extinguishing system to be serviced annually. 46 CFR 181
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 October 2018
Resolved
Bilge visual high level alarms to be moved to a location to allow master to be alerted when light turns on. 46 CFR 182.530
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 October 2018
Resolved
Replace wasted life float painter with at least 100 feet of approved type line with proper week link attached. 46 CFR 180.175
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 17 October 2018
Resolved
Replace expired EPIRB hydrostatic release. 46 CFR 185.740
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 October 2018
Resolved
Install quick acting non-corrosive clip to life ring floating light line. 46 CFR 180.70(d)(3)
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 17 October 2018
Resolved
Provide FCC Radio Safety Certificate. 46 CFR 80.401
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 October 2018
Resolved
Post emergency procedures, COI and stability letter. 46 CFR 185.512
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 August 2018
Resolved
Make repairs to fiberglass at marked spots on hull. Vessel restricted to no more than 6 passengers prior to credit dry-dock 46 CFR 176.610
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 19 July 2016
Resolved
Provide crew list as dicussed with CGMI.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 19 July 2016
Resolved
Provide log book for drills and epirb checks.
Lifesaving › Lifebuoys › Serviceable
Issued 19 July 2016
Resolved
Provide new ring buoy.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 July 2016
Resolved
Prove proper operation of the ring buoy water light.
Communications › Radio Communications › EPIRB
Issued 19 July 2016
Resolved
Provide new epirb, battery had expired in old one.
Communications › Radio Communications › EPIRB
Issued 19 July 2016
Resolved
Provide new hydrostatic release for epirb.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 July 2016
Resolved
Provide new first aid kit with contents as per 160.041.
Lifesaving › Lifefloat › Serviceable
Issued 19 July 2016
Resolved
Repair cracks in lifefloat with [name withheld] rpair kit.
Lifesaving › Lifefloat › Paddle
Issued 19 July 2016
Resolved
Provide two paddles for life float.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 July 2016
Resolved
Provide waterlight for life float.
Lifesaving › Lifefloat › Painter
Issued 19 July 2016
Resolved
Attach painter to life float.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 19 July 2016
Resolved
Mount B-1 extinguisher as discussed with CGMI.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 19 July 2016
Resolved
Have all portable fire fighting equipment serviced by third party vendor.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 19 July 2016
Resolved
Prove proper operation of fireboy shut downs.
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 July 2016
Resolved
Prove proper operation of emergency fuel shut off valves.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 19 July 2016
Resolved
Provide current radio safety certificate.
Documentation › Certificates/Documents › FCC SSL
Issued 19 July 2016
Resolved
Provide current FCC SSL.
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 July 2016
Resolved
Conduct underway drills with CGMI prior to carrying passengers.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 19 July 2016
Resolved
Label number of PFD's in storage area.
Documentation › Certificates/Documents › Permit, Other
Issued 19 July 2016
Resolved
Provide FCC operator's permit.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 19 July 2016
Resolved
Install MF or HF radio prior to going beyond 20 miles from the shoreline.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 19 July 2016
Resolved
Provide first aid/CPR training for deckhands.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 July 2016
Resolved
Replace lens for port running light.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 19 July 2016
Resolved
Stow children's life jackets separate from adult PFD's.
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 July 2016
Resolved
Label emergency fuel shut-ioff valves.
Engineering › Bilge Water Management System › Piping
Issued 17 September 2008
Resolved
Remove rubber hose sections in bilge piping system. Replace with approved coupling.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 August 2008
Resolved
Properly secure rails in way of loose bolts.
Stability › Unintentional Flooding › General
Issued 26 August 2008
Resolved
Properly seal hatch on collision bulkhead.
Lifesaving › Lifefloat › Serviceable
Issued 2 April 2008
Resolved
life float has several small tears and punctures that require repairs, reseal all holes and tears to the satisfaction of the CG Inspector.
Lifesaving › Lifebuoys › Serviceable
Issued 2 April 2008
Resolved
Lifebuoy has small hole in cover and trim is coming loose, reseal hole and reattach trim ring.
Communications › Radio Communications › EPIRB
Issued 2 April 2008
Resolved
EPIRB Hydrostatic release due date expired in Feb 2008, replace hydrostatic release.
Stability › Incline Test › General
Issued 3 October 2007
Resolved
Vessels stability letter states that maximum fixed height above the waterline is not to exceed 10.5 feet. The vessel has a permanently installed canopy over the operating station that extends to approximately 15 feet above the water line. Either remove the canopy top or make it retractable, stability letter states that the top must be lowered when operating more than 20NM from shore.
Lifesaving › Visual Distress Signals (General) › Marking
Issued 2 April 2007
Resolved
Properly label distress signal storage box.
Lifesaving › Lifefloat › Paddle
Issued 2 April 2007
Resolved
Properly attach paddles onto the lifefloat.
Lifesaving › Lifefloat › Markings
Issued 2 April 2007
Resolved
Re-stencil and apply retroflective tape as needed to life float, life buoy, and life jackets.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 2 April 2007
Resolved
Repair missing screws on stbd hand grab on wheelhouse.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 April 2007
Resolved
Demonstrate proper operation of bilge alarms.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 April 2007
Resolved
Shorten line for ring life buoy and remount light for life float closer to the float.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 April 2007
Resolved
Ensure all labels for life jacket stowage, fuel shutoffs and emergency broadcast instructions are posted and visible.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 April 2007
Resolved
Ensure port and stbd running lights are the required arcs of visibility per the Navigation Rules, as stands lights are obstructed by canopy supports.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 2 April 2007
Resolved
Re-install hoses to 3-way valve and place locking device on overboard discharge of MSD.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 2 April 2007
Resolved
Modify emergency procedures for abandon ship, man overboard, and firefighting making them ship specific and submit to the Coast Guard for approval.
Personnel › Manning/Qualifications › First Aid Certified Personnel
Issued 2 April 2007
Resolved
One member of crew must have valid CPR certification.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 26 September 2006
Resolved
Until such time as the Safety Radio Telephone Certificate is placed onboard the vessel, the vessel is limited to not more than -20- miles from shore.
Documentation › Markings/Placards › Official Number (US)
Issued 26 September 2006
Resolved
Remark the stern hailing port to agree with the vessel's Certificate of Documentation, or, change the vessel's Certificate of Documentation to agree with the vessel's hailing port.
Lifesaving › Lifefloat › Serviceable
Issued 5 April 2006
Resolved
Make permanent repairs to life float outer covering and relocate the waterlifgt to a float free position.
Navigation › Piloting/Steering › Marine Charts
Issued 5 April 2006
Resolved
update local area charts and renew 46 CFR parts 166-199 to a current issue.
Lifesaving › Lifebuoys
Issued 27 March 2003
Resolved
lifeline on life float weathered, replaced lifeline with an approved new lifeline. LEGACY COMPONENT DESC: Buoyant Lifeline
Lifesaving › Lifebuoys
Issued 27 March 2003
Resolved
Properly mark Life Ring Buoy with vessel name /# LEGACY COMPONENT DESC: Markings (ship name/port)
Engineering › Steering Gear System
Issued 28 October 2002
Resolved
REPLACE UPPER RUDDER BEARING IN STEERING COMPARTMENT. BEARING WAS COMPLETELY DETERIORATED. LEGACY COMPONENT DESC: Rudder Bearing
Electrical › Electrical Distribution System (service)
Issued 28 October 2002
Resolved
REPAIR BROKEN BONDING STRAPS IN THE ENGINE ROOM & STEERING COMPARTMENT. STRAPS WERE SEVERED IN THE THOSE AREAS. LEGACY COMPONENT DESC: Grounding Conductor
Documentation
Issued 8 April 1999
Resolved
Vessel's FCC OPERATOR'S LICENSE HAS EXPIRED. VESSEL REQUIRED TO RENEW PRIOR TO 08MAY99.
Fire Fighting
Issued 8 April 1999
Resolved
Vessel required to install fixed firefighting system prior to 08May99.
Lifesaving
Issued 8 April 1998
Resolved
The battery for the EPIRB expired on 01/98. Although a satisfactory test was conducted, the route was limited to within 3nm until a proper battery is installed or a new Class 1 406 EPIRB is installed.
Lifesaving
Issued 8 April 1998
Resolved
Improper style ring buoy (white). Required to provide proper size/color ring buoy to conform to new 46CFR requirements.
Lifesaving
Issued 8 April 1998
Resolved
The vessel design and their procedures for extracting a person from the water proved to be incompatible. Required the owner/operator to provide a ladder for manoverboard scenarios, incorporate it into their written procedures, and to conduct another drill in the presence of the USCG.
Engineering
Issued 8 April 1998
Resolved
No marking for location/direction of turn for securing the emergency fuel shutoff.
Lifesaving
Issued 8 April 1998
Resolved
Life Float not properly marked (capacity).
Construction/Loadline
Issued 9 April 1997
Resolved
RE-INSTALL POWER DRIVEN BILGE PUMP.
Lifesaving
Issued 9 April 1997
Resolved
REPLACE RETROFLECTIVE TAPE ON (5) ADULT/(1) CHILD LIFEJACKET, LIFEBOAT, ANDRING BUOY.
Engineering
Issued 9 April 1997
Resolved
PROVIDE HEAT DEFLECTOR FOR FUEL FILTER.
Documentation
Issued 9 April 1997
Resolved
PROVIDE DRUG TESTING RESULTS FOR DECKHAND.
Lifesaving
Issued 9 April 1997
Resolved
PROVIDE WATERTIGHT CONTAINER FOR PYROTECHNICS. CONTAINER MUST BE MARK "DISTRESS SIGNALS" AND INTERNATIONAL ORANGE COLOR CONTAINER.
Navigation
Issued 4 November 1996
Resolved
RENEW RUDDER YOKE BALL-JOINT ON CYLINDER RAM.
Construction/Loadline
Issued 4 November 1996
Resolved
REPAIR CRACKS ON PORT/STBD SIDES OF BOTTOM OF E/R.
Construction/Loadline
Issued 4 November 1996
Resolved
REPAIR DAMAGED GELCOAT ON STEM.
Construction/Loadline
Issued 12 April 1996
Resolved
REPAIR ENGINE DRIVEN BILGE PUMP.
Unknown
Issued 12 April 1996
Resolved
PROVIDE REQUIRED PUBS: LIGHTLIST, TIDE TABLE, TIDE CURRENTS AND COAST PILOT.
Documentation
Issued 28 April 1993
Resolved
Provide proof of random selection program for chemical testing program per 46CFR16.230(c).
Documentation
Issued 28 April 1993
Resolved
Develope and submit a copy of Employee Assistance Program per 46CFR16.401. Include procedures following a positive drug test.
Engineering
Issued 22 October 1992
Resolved
PROVIDE PROP STRUT FOR INSPECTION.
Deck/Cargo
Issued 22 October 1992
Resolved
PROVIDE ANCHOR FOR INSPECTION.
Construction/Loadline
Issued 22 October 1992
Resolved
RENEW FRACTURED/DELAMINATED FRP IN WAY OF HOLDING TANK.
Engineering
Issued 22 October 1992
Resolved
PROVIDE PROP FOR INSPECTION.
Documentation
Issued 15 May 1985
Resolved
THE VESSEL HAD NOT BEEN DOCUMENTED WHEN IT LEFT THE MANUFACTURER ENROUTE ITS HOME PORT. THE VESSEL HAS BEEN DOCUMENTED AT THIS TIME BUT THE NUMBER ON THE MAIN BEAM MUST BE CHECKED.
Accommodation/Occupational Safety
Issued 15 May 1985
Resolved
THE RAILINGS ON THE AFT SIDE OF THE UPPER CONTROL STATION ARE NOT 36 INCHESHIGH AND HAVE NO RUNGS OF THE 12 INCH MAXIMUM SEPERATION.
Engineering
Issued 15 May 1985
Resolved
THE EMERGENCY FUEL CUT-OFF VALVES WERE NOT LABLED PENDING FINAL PAINTING OFTHE VESSEL INTERIOR.
Documentation
Issued 15 May 1985
Resolved
THE COI, RADIO LICENSES, OIL DISCHARGE PLACARD AND EMERGENCY INSTRUCTIONS TO THE PASSENGERS WERE NOT POSTED.
Fire Fighting
Issued 15 May 1985
Resolved
THE TWO B-II PORTABLE FIRE EXTINGUISHERS ARE NOT MOUNTED YET DUE TO FINAL PAINTING OF THE VESSEL.
Casualty record · 2
6 October 2019Routine · role: Involved in a Marine Casualty · activity 6829732
5 September 2022Routine · role: Involved in a Marine Casualty · activity 7557858
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.