Records from 1985 to 1993. Most recent: inspection, 24 August 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 23
24 August 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 652644
27 May 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 648039
27 May 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 696173
7 May 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 693162
30 April 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 646640
29 April 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 693472
27 April 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 98765
26 April 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 832244
26 April 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435363
28 December 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 652645
26 December 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 151948
1 September 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 82243
28 August 1992
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1266895
3 May 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 461917
3 May 1992
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 519167
7 September 1991
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1243550
14 December 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 513296
23 November 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 319828
23 November 1987
Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1002755
29 August 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 311220
29 August 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1272817
29 October 1985
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 305016
4 June 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 302278
Deck/Cargo
Issued 26 April 1993
Resolved
D9. CROP AND RENEW INERT GAS SYSEM RECIRCULATION PIPE AT AFT END OF SCRUBBER WHERE SOFT PATCH IS INSTALLED.
Condition: Unknown
Due 26 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 26 April 1993
Resolved
D10. RENEW WASTED FLANGE BOLTS FOR THE INERT GAS SYSTEM PIPING ON THE MAINDECK NEAR THE DECK WATER SEAL.
Condition: Unknown
Due 26 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 26 April 1993
Resolved
D11. RENEW WASTED BOLTS ASSOCIATED WITH THE STRUCTURE OF THE DECK WATER SEAL.
Condition: Unknown
Due 26 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 26 April 1993
Resolved
D12. RENEW LEAKING PIPE COUPLING TO INLET PIPE ON MAIN TANK OF OILY WATER SEPERATOR.
Condition: Unknown
Due 26 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 26 April 1993
Resolved
D7. CROP AND RENEW SCRUBBER DRAIN LINE NEAR TOP OF SCRUBBER WHERE A SOFT PATCH IS INSTALLED.
Condition: Unknown
Due 26 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 26 April 1993
Resolved
D8. CROP AND INSERT LOWER AFT END OF SCRUBBER WHERE DOUBLER PLATE IS INSTALLED.
Condition: Unknown
Due 26 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 26 April 1993
Resolved
D1. RENEW INERT GAS MAIN SUPPLY PIPING WHERE TEMPORARY PATCHES ARE INSTALLED FORWARD OF DECK ISOLATION VALVES OVER #3 CENTER BALLAST TANK.
Condition: Unknown
Due 26 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 26 April 1993
Resolved
D14. PROVIDE UPDATED CLASSIFICATION SOCIETY REPORT FOR THE INERT GAS SYSTEM. THE INSPECTION REPORT MUST BE DATED AFTER 26APR93 TO REFLECT CORRECTION OF ALL OUTSTANDING DISCREPANCIES IDENTIFIED AT 26APR93 INSPECTION.
Condition: Unknown
Due 26 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 26 April 1993
Resolved
D2. RENEW INERT GAS SUPPLY BRANCH PIPING WHERE SOFT PATCH IS INSTALLED ON PIPING TO #2 CENTER CARGO TANK.
Condition: Unknown
Due 26 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 26 April 1993
Resolved
D3. RENEW INERT GAS MAIN SUPPLY PIPING FORWARD OF DECK ISOLATION VALVES WHERE SEVERE PITTING HAS OCCURRED AND EPOXY FILLER USED IN VARIOUS AREAS. ENTIRE LENGTH OF IG MAIN PIPING TO BE RENEWED WHERE NECESSARY TO ELIMINATE EXCESSIVE PITTING.
Condition: Unknown
Due 26 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 26 April 1993
Resolved
D4. RENEW INERT GAS SYSTEM #1 BLOWER DISCHARGE DUCT WHERE DOUBLER PLATES ARE INSTALLED.
Condition: Unknown
Due 26 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 26 April 1993
Resolved
D5. RENEW INERT GAS SYSTEM #2 BLOWER DISCHARGE DUCT WHERE DOUBLER PLATES ARE INSTALLED.
Condition: Unknown
Due 26 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 26 April 1993
Resolved
D6. CROP AND INSERT LOWER SECTION OF THE SCRUBBER WHERE A 1'X3' CEMENT PATCH IS LOCATED.
Condition: Unknown
Due 26 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 26 April 1993
Resolved
D13. CONDUCT FURTHER INSPECTION OF POSSIBLE FRACTURE IN LONGITUDINAL BULK-HEAD BETWEEN #3 CENTER BALLAST AND #3 PORT CARGO TANK. PROVIDE SURVEY REPORT WITH POSSIBLE NDT RESULTS TO DETERMINE EXTENT OF FRACTURE AND TYPE OF REPAIR CONDUCTED. APPROX. LOC= 30' UP FROM BOTTOM & 40' AFT OF FWD BLKD.
Condition: Unknown
Due 26 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 28 August 1992
Resolved
REPAIR WASTED AND BROKEN FOAM MONITOR CONTROL HANDLE - MAIN DECK. PORTSIDE,FORWARD OF HOUSE.
Condition: Unknown
Due 28 August 1992
Resolved 28 August 1992
Fire Fighting
Issued 28 August 1992
Resolved
INSTALL STEP GRATING TO #2 FOAM MONITOR.
Condition: Unknown
Due 28 August 1992
Resolved 28 August 1992
Deck/Cargo
Issued 28 August 1992
Resolved
RENEW CRUDE OIL WASHING LINES TO #1 STBD AND #5 PORT WHERE SOFT PATCHED.
Condition: Unknown
Due 28 August 1992
Resolved 28 August 1992
Documentation
Issued 7 September 1991
Resolved
PROVIDE MSO PHILADELPHIA WITH A COPY OF CURRENT IOPP CERTIFICATE PRIOR TO DEPARTURE FROM PORT.
Condition: Unknown
Due 12 September 1991
Resolved 12 September 1991
Navigation
Issued 7 September 1991
Resolved
PROVIDE COPY OF CURRENT UPDATED MAGNETIC COMPASS DEVIATION TABLE TO MSO_x001C_ PHILADELPHIA PRIOR TO DEPARTURE FROM PORT OF PHILADELPHIA.
Condition: Unknown
Due 12 September 1991
Resolved 12 September 1991
Deck/Cargo
Issued 23 November 1987
Resolved
46 CFR 32.53-60 PRESSURE INDICATOR IN ENGINE CONTROL ROOM, FOR IGS, NOT OPERATING PROPERLY, AS REQUIRED.
Condition: Unknown
Due 26 September 1991
Resolved 26 September 1991
Deck/Cargo
Issued 23 November 1987
Resolved
33 CFR 157.12 (D)(2) OIL DISCHARGE MONITORING AND CONTROL SYSTEM ONBOARD BUT NOT INSTALLED, AS REQUIRED.
Condition: Unknown
Due 26 September 1991
Resolved 26 September 1991
Accommodation/Occupational Safety
Issued 23 November 1987
Resolved
33 CFR 159.7 (C) PROVIDE PROOF OF CERTIFICATION OF THE MARINE SANITATION DEVICE, AS REQUIRED.
Condition: Unknown
Due 26 September 1991
Resolved 26 September 1991
Fire Fighting
Issued 4 June 1985
Resolved
VESSEL DID NOT HAVE A FIXED CO2 OR WATER SPRINKLING FIREFIGHTING SPRINKLINGSYSTEM FOR THE PAINT LOCKER ON BOARD AS REQUIRED BY 46 CFR 34.05-5(3).
Condition: Unknown
Due 4 June 1985
Resolved 4 June 1985
Fire Fighting
Issued 4 June 1985
Resolved
VESSEL DID NOT HAVE FIRE CONTROL PLANS IN WEATHERTIGHT CONTAINER LOCATED OUTSIDE THE DECKHOUSE FOR SHORESIDE FIREFIGHTING PERSONNEL AS REQUIRED BY SOLAS REG 20-2.
Condition: Unknown
Due 4 June 1985
Resolved 4 June 1985