Records from 1985 to 2000. Most recent: inspection, 6 March 2000.
Inspection history · 34
6 March 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815791
20 November 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1420024
1 December 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1467523
28 January 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1101977
21 January 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1098619
4 December 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1390409
6 December 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1435699
4 October 1995
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1182764
5 December 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1387651
18 April 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1167769
22 March 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 855069
1 December 1993
Letter of Compliance (Initial/Renewal) · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428288
10 March 1993
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 837724
1 December 1992
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370511
26 August 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 19702
16 October 1991
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1251673
28 January 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 915715
3 December 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911465
20 November 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1211131
28 September 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 914610
9 August 1990
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 899947
12 April 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 917988
22 January 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231097
17 November 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226000
9 August 1989
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 888276
15 November 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 898875
13 October 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 887367
11 August 1988
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1195991
8 February 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1019139
21 September 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1023404
13 August 1987
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1337388
17 April 1986
Examination of Repairs
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1306430
13 March 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 993810
20 May 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 983813
Lifesaving
Issued 20 November 1998
Resolved
CONDUCT 1.1 OPERATIONAL TEST OF LIFEBOAT RELEASE GEAR ON BOTH BOATS. ALTERNATE TEST MUST BE APPROVED BY THE COGNIZANT OCMI.
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Lifesaving
Issued 20 November 1998
Resolved
REPAIR WINCH MOTOR FOR #2 LIFEBOAT. UPON REPAIR CONDUCT AND LOG OPERATIONALTEST. REPLACE STARTING BATTERY ON #2 LIFEBOAT.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Documentation
Issued 1 December 1997
Resolved
Demonstrate compliance with all of the requirements applicable to non-self propelled MODUS contained in (1996) 46 CFR 109 Subpart B; specifically the "Emergency training and drills" requirements of 46 CFR 109.213. Drills must be logged IAW CGD8 Guidance on Lifesaving Regulations, enclosure (A).
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Lifesaving
Issued 1 December 1997
Resolved
Free-up port lifeboat brake release cable mechanism so that lifeboat can belowered to water without assistance from man at winch.
Condition: Unknown
Due 29 December 1997
Resolved 29 December 1997
Electrical
Issued 1 December 1997
Resolved
Prove proper operation of #1 generator in parallel w/other generators.
Condition: Unknown
Due 29 December 1997
Resolved 29 December 1997
Electrical
Issued 4 December 1996
Resolved
RELABEL FADED SIGN FOR TOTAL RIG SHUTDOWN ON DRILL FLOOR.
Condition: Unknown
Due 4 December 1996
Resolved 21 January 1997
Fire Fighting
Issued 4 December 1996
Resolved
REPAIR WASTED PIPING AT FIRE STATION #1 & #12.
Condition: Unknown
Due 11 December 1996
Resolved 21 January 1997
Electrical
Issued 4 December 1996
Resolved
REMOUNT ELECTRICAL JUNCTION BOX FOR SCR AIR CONDITIONING UNIT.
Condition: Unknown
Due 4 December 1996
Resolved 21 January 1997
Lifesaving
Issued 4 December 1996
Resolved
REMOVE ALL EXPIRED MEDICINES IN HOSPITAL SPACE.
Condition: Unknown
Due 4 December 1996
Resolved 21 January 1997
Fire Fighting
Issued 4 December 1996
Resolved
REPLACE NOZZLE AT FIRE STATION #6.
Condition: Unknown
Due 4 December 1996
Resolved 21 January 1997
Engineering
Issued 4 December 1996
Resolved
REPLACE HOSE CLAMPS ON EMERGENCY GENERATOR FUEL HOSES WITH PROPER HOSE FITTINGS.
Condition: Unknown
Due 4 January 1997
Resolved 21 January 1997
Fire Fighting
Issued 4 December 1996
Resolved
PROVIDE FLAG STATE APPROVAL FOR ALTERNATIVE FIREFIGHTING ARRANGEMENT IN MCCROOM TO MSO PORT ARTHUR.
Condition: Unknown
Due 11 December 1996
Resolved 21 January 1997
Electrical
Issued 4 December 1996
Resolved
LAY DOWN ADDITIONAL ELECTRICAL MATTING IN MCC ROOM THAT COVERS ALL AREAS INFRONT OF SWITCHBOARDS.
Condition: Unknown
Due 4 January 1997
Resolved 21 January 1997
Electrical
Issued 4 December 1996
Resolved
REMOVE DEADENDED WIRING IN OVERHEAD ABOVE FIREPUMP #1.
Condition: Unknown
Due 4 January 1997
Resolved 21 January 1997
Construction/Loadline
Issued 4 December 1996
Resolved
REWELD INPROPER REPAIR TO OVERHEAD INSERT IN GENERATOR ROOM.
Condition: Unknown
Due 4 January 1997
Resolved 21 January 1997
Lifesaving
Issued 4 December 1996
Resolved
PROVE PROPER OPERATION OF EYE WASH STATION IN MUDPIT ROOM & PROVIDE DIRT CAPS FOR THE SAME.
Condition: Unknown
Due 4 January 1997
Resolved 21 January 1997
Lifesaving
Issued 4 December 1996
Resolved
HYDROSTATICALLY TEST THE BREATHING AIR BOTTLES IN BOTH LIFEBOATS.
Condition: Unknown
Due 4 January 1997
Resolved 21 January 1997
Construction/Loadline
Issued 4 December 1996
Resolved
REPAIR WASTED SECTIONS OF PORT LIFEBOAT DAVIT WALKWAY SUPPORT MEMBERS.
Condition: Unknown
Due 4 January 1997
Resolved 21 January 1997
Fire Fighting
Issued 4 December 1996
Resolved
PROVE PROPER OPERATION OF AUXILIARY FIREPUMP.
Condition: Unknown
Due 11 December 1996
Resolved 21 January 1997
Lifesaving
Issued 4 December 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 January 1997
Resolved 21 January 1997
Electrical
Issued 4 December 1996
Resolved
PROVE PROPER OPERATION OF DRILLER'S CONSOLE PURGE ALARM.
Condition: Unknown
Due 4 January 1997
Resolved 21 January 1997
Lifesaving
Issued 4 December 1996
Resolved
PROVIDE MISSING PERSONAL PROTECTIVE EQUIPMENT (HEARING PROTECTION) IN THEIRRESPECTIVE STORAGE BOXES.
Condition: Unknown
Due 4 January 1997
Resolved 21 January 1997
Construction/Loadline
Issued 4 December 1996
Resolved
READJUST ALL WATERTIGHT MAINDECK DOORS TO THE MACHINERY SPACES.
Condition: Unknown
Due 11 December 1996
Resolved 21 January 1997
Lifesaving
Issued 1 December 1993
Resolved
PROVIDE TWO CALIBRATED O2/EXPLOS. METERS.
Condition: Unknown
Due 1 January 1994
Resolved 23 December 1993
Lifesaving
Issued 1 December 1993
Resolved
HYDRO OXYGEN AND AIR BOTTLES AS NEEDED.
Condition: Unknown
Due 1 January 1994
Resolved 23 December 1993
Lifesaving
Issued 1 December 1993
Resolved
STRIP & CLEAN BOTH LIFEBOATS, CHANGE FUEL AND DOCUMENT SEMIANNUAL TEST OF E-BAT.
Condition: Unknown
Due 1 January 1994
Resolved 6 December 1993
Electrical
Issued 1 December 1993
Resolved
REPAIR AND PROVE PROPER OPERATION OF TOTAL RIG SHUT DOWN SWITCH IN CONJUNCTION WITH EMER GEN AUTO BUS TRANSFER AND START.
Condition: Unknown
Due 15 December 1993
Resolved 23 December 1993
Construction/Loadline
Issued 1 December 1993
Resolved
ADJUST WATERTIGHT SELF CLOSING DOOR MAIN DECK TO MUD PIT ROOM
Condition: Unknown
Due 1 January 1994
Resolved 23 December 1993
Lifesaving
Issued 1 December 1993
Resolved
REPAIR LIFEBOAT #1 PORT LIMIT SWITCH AND CENTRIFUGAL BRAKE.
Condition: Unknown
Due 8 December 1993
Resolved 23 December 1993
Fire Fighting
Issued 1 December 1993
Resolved
TEST FIRE DETECTION SYSTEM.
Condition: Unknown
Due 1 January 1994
Resolved 23 December 1993
Electrical
Issued 1 December 1993
Resolved
REPAIR, TEST AND PROVE PROPER OPERATION OF PURGE SYSTEM ON SERVICE EQUIPMENT (SWATCO AND DRILLOG) DRILL FLOOR AND DRILLERS CONSOLE
Condition: Unknown
Due 8 December 1993
Resolved 23 December 1993
Fire Fighting
Issued 1 December 1993
Resolved
REPLACE OR REPAIR BRACKETS FOR FIRE EXT. #57 AND 59 IN MOTOR ROOM.
Condition: Unknown
Due 1 January 1994
Resolved 23 December 1993
Electrical
Issued 1 December 1993
Resolved
MAKE PERMANENT WIRING CONNECTIONS AND REMOVE OR COVER JUNCTION BOX BEHIND EMER. GEN. SWITCHBOARD.
Condition: Unknown
Due 15 December 1993
Resolved 23 December 1993
Electrical
Issued 1 December 1992
Resolved
REPAIR AND TEST EMERGENCY GENERATOR PRIOR TO CONDUCTING WELL WORKOVER.
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992
Lifesaving
Issued 1 December 1992
Resolved
PROVIDE TWO FIREMAN'S OUTFITS.
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992
Lifesaving
Issued 1 December 1992
Resolved
HYRDO AIR PACK BREATHING AIR BOTTLES.
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992
Electrical
Issued 1 December 1992
Resolved
TEST #4 GENERATOR'S REMOTE SHUTDOWN. TEST #2 & 4 GENERATOR'S HIGH TEMP. ALARM. _x001C_
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992
Construction/Loadline
Issued 1 December 1992
Resolved
INSPECT MUD PIT UPON COMPLETION OF REPAIRS. TEST FIRE STATION #9. TEST GENERAL ALARM BELLS. TEST TO BE COMPLETED PRIOR TO DRILLING.
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992
Lifesaving
Issued 1 December 1992
Resolved
INSTALL WEAK LINKS TO BOTH LIFERAFTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992
Electrical
Issued 1 December 1992
Resolved
REPLACE EXANE CABLE IN SHALE SHAKER AREA WITH PROPER WIRE FOR HAZARDOUS LOCATION, CLASS I DIV I.
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992
Deck/Cargo
Issued 1 December 1992
Resolved
REPAIR PORT AND STARBOARD CRANE ANTI-TUBE LOCK SAFETY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992
Fire Fighting
Issued 1 December 1992
Resolved
INSTALL/TEST HALON ENGINE AUTO. SHUTDOWN.
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992
Lifesaving
Issued 1 December 1992
Resolved
REPLACE BOUYANT ROCKETS TO THE LINE THROWING GUN.
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992
Lifesaving
Issued 1 December 1992
Resolved
PROVIDE 1500 FOOT AUX. LINE (3" MANILA) FOR LINE THROWING GUN.
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992
Unknown
Issued 9 August 1990
Resolved
PROVIDE PROOF OF TESTING FOR OIL/FUEL OIL TRANSFER HOSES AT 1.5 TIMES MAWP (WHICH IS A MINIMUM OF 150 PSI MAWP) IAW 33 CFR 154.500 AND 33 CFR 156.170.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Accommodation/Occupational Safety
Issued 9 August 1990
Resolved
PROVE PROPER OPERATION OF THE FOLLOWING PRESSURE VESSEL RELIEF VALVES: RIG AIR AND DRILL FLOOR AIR.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Documentation
Issued 9 August 1990
Resolved
PROVIDE ABS REPORT FOR UNDERWATER SURVEY IN LIEU OF DRYDOCKING UPON COMPLETION OF SURVEY WHICH HAS BEEN STARTED.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Electrical
Issued 9 August 1990
Resolved
PROVE PROPER OPERATION OF MAIN AND EMERGENCY GENERATOR OVERSPEEDS, LOW LUBEOIL SHUTDOWNS, AND HIGH TEMPERATURE SHUTDOWNS.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Electrical
Issued 9 August 1990
Resolved
PROVE PROPER OPERATION OF ALL MAIN GENERATOR REVERSE POWER RELAYS.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Documentation
Issued 9 August 1990
Resolved
PROVIDE COPY OF ABS SURVEY AND ALL ASSOCIATED UPDATED DOCUMENTS. NOTE: ABS SURVEY IN PROGRESS AT TIME OF THIS LOC INSPECTION.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Unknown
Issued 9 August 1989
Resolved
REWIRE SWACO GEOLOGRAPH AT EXPLOSSIVE PROOF JUNCTION BOX POURED FITTING REQUIRED EYS FOR INSTALLATION USE APPROVED WIRE FOR INSTALLATION.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 9 August 1989
Resolved
CORRECT AUDIBLE ALARM ON DRILLERS CONSOLE (BAD GASKET).
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 9 August 1989
Resolved
PROVIDE RELIEF VALVES FOR ALL BULK AND CEMENT TANKS THAT DON'T EXCEED MAWP ALL ARE 40PSI ALL VALVES ON BOARD ARE 44PSI.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 9 August 1989
Resolved
INSTALL PAD LOCK ON GENERAL ALARM DISCONECT SWITCH BETWEEN DISTRIBUTION PANEL AND POWER SUPPLY.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 9 August 1989
Resolved
PROVIDE MANUFACTURER DATA ON BOTTLES (HYDRO DATE AND PRESSURE) AND REGULATOR RELIEF VALVE SETTING USED IN LIFEBOAT AIR PURGING SYSTEM.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 9 August 1989
Resolved
PROVIDE SECOND BOAT HOOK FOR #2 (PORT) LIFEBOAT.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 9 August 1989
Resolved
RENEW LINE THAT IS USED TO ATTACH WATERLIGHTS TO RING BOUYS. LINE IS TO BE RESISTANT TO ULTRA VIOLET LIGHT.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 9 August 1989
Resolved
HYDRO AND REFILL TANKS FOR THE SCBA AS DIRECTED.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 9 August 1989
Resolved
PLACE ONBOARD VESSEL 1500' AUXILLARY LINE FOR LINE THROWING APPLIANCE KIT.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 9 August 1989
Resolved
WEIGHT TEST BOTH BOATS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 9 August 1989
Resolved
REWIRE THE JUNCTION BOX ON THE MATHEW WIRE LINE UNIT.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 9 August 1989
Resolved
REWIRE THE JUNCTION BOX ON THE BOP HYDRALIC SYSTEM.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 9 August 1989
Resolved
POUR EYS FITTINGS IN HAZARDOUS LOCATIONS AS NECESSARY.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 9 August 1989
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 9 August 1989
Resolved
PROVIDE REPORT OF THE ANNUAL LOAD LINE INSPECTION LAST 27MAY88.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 9 August 1989
Resolved
RIG HAS TWO (2) IOPP CERTIFICATE WITH ALTERNATING ENDORSMENT.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 9 August 1989
Resolved
CONDUCT AND RECORD TEST AND INSPECTION REQUIRED BY 46CFR 109.211, 109.207, AND 109.208.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 13 August 1987
Resolved
REPAIR THE ELECTRICAL FITTING TO THE PUBLIC ADDRESS SPEAKER BEHIND THE #1 CEMENT TANK.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
REPAIR OR REMOVE THE CONTROLLER AS MARKED BY THE HALLIBURTON UNIT.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
INSTALL PERMANENT COVERS OVER THE BLANK EMERGENCY BREAKER SWITCHES ON THE EMERGENCY SWITCHBOARD.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
MAKE THE EMERGENCY GENERATOR AVAILABLE FOR TESTING OF THE EMERGENCY SHUTDOWN.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
INSTALL THE MISSING LIGHT GUARD ABOVE THE LADDER FROM THE MAIN DECK TO THE MUD PIT ROOM.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
REPAIR ALL LIGHTING ON THE DRILL FLOOR (ONE FIXTURE IS PRESENTLY NOT OPERATING).
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
RESOLVE THE HALON SYSTEM BEING SLIGHTLY BELOW PRESSURE (IN THE RED). SYSTEM WAS SERVICED BUT NOT PRESSURED TO SATISFACTORY LEVEL.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
INSTALL PRESSURE RELIEF VALVES FOR SURGE TANKS TO POTABLE WATER AND SANITATION WATER SYSTEMS.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
REMOVE ALL HYDRAULIC OIL AND WATER IN SPACES AROUND COLUMN JACKING SYSTEMS FOR EACH COLUMN (LEG).
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
MAKE THE MARINE SANITATION DEVICE FULLY OPERATIONAL.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
REPAIR THE EMBARKATION LADDER.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
INSTALL EMBARKATION LADDERS WHEN ON STATION.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
SERVICE THE DRILLER'S CONSOLE AND MAKE THE LOSS OF PURGE AIR ALARM AND THE PURGE AIR SYSTEM OPERABLE.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
MAKE THE LOSS OF VENTILATION TO THE MUD PIT ALARM ON THE DRILL FLOOR OPERABLE.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
SET AND MAKE READY FOR TEST OF ALL PRESSURE RELIEF VALVES FOR THE 12 PRESSURE VESSELS. EACH PRESSURE RELIEF VALVE IS REQUIRED TO RELIEVE AT OR BELOW THE MAXIMUM ALLOWABLE WORKING PRESSURE OF THE PRESSURE VESSEL.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
MAKE OPERABLE ALL SELF-CLOSING WATERTIGHT DOORS TO THE MUD PIT ROOM.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
MAKE OPERABLE THE GENERAL ALARMS IN THE SHALESHAKER AND ON THE DRILL FLOOR.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
REPAIR ALL VENTILATION COVERS (DOGS AND COVERS) AS MARKED ON DECK.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
REPLACE AIR HOSE TO PRESSURE GAUGE ON THE #3 CEMENT TANK.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
SUBMIT PROPOSAL TO INSTALL EMBARKATION LADDERS FORWARD OF BOTH LIFEBOATS.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
REPAINT THE NAME AND AIMING CIRCLES ON THE HELICOPTER DECK.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
REPAINT AND RELABEL ALL FIRE STATIONS ON DECK.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
PROVIDE A FIRE HOSE FOR FIRE STATION NO. 1 ON THE HELICOPTER DECK.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
PROVIDE 2 B-V'S FOR THE HELICOPTER DECK.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
SUBMIT AN UPDATED FIRE CONTROL PLAN FOR APPROVAL.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
REPLACE THE BROKEN SMOKE DETECTOR.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
PROVE OPERATION OF STERN LIGHT AND STARBOARD, FORWARD OBSTRUCTION LIGHT.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
PROVIDE APPROVED FIRST AID KIT, ORGANIZE HOSPITAL AREA AND PURCHASE NEW SUPPLIES AS NEEDED.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
PROVIDE WEATHERTIGHT STUFFING TUBE FOR LIFEBOAT WINCH CONTROLLERS.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
PROVIDE 4 PAINTER LINER (2 FOR EACH LIFEBOAT), EACH ONE TO BE 60' LONG.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
PROVIDE A LANTERN FOR THE #1 LIFEBOAT.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
REPLACE THE BROKEN SPRINKLING SYSTEM PIPING AROUND THE STERN OF LIFEBOAT #1.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
PROVE OPERATION OF THE DISENGAGING GEAR ON LIFEBOAT #2.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
PROVE OPERATION OF THE FORWARD LIMIT SWITCH ON LIFEBOAT #1 BEFORE COMMENCING DRILLING OPERATIONS.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Unknown
Issued 13 August 1987
Resolved
REPAIR EYS FITTINGS AS INDICATED TO THE PERSON IN CHARGE ON THE DRILL FLOOR, MUD PIT ROOM, AND SHALESHAKER. ALSO TIGHTEN ALARM LIGHT FITTINGS ONTHE DRILL FLOOR.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Fire Fighting
Issued 13 March 1986
Resolved
PROVIDE APPLICATORS FOR MACHINERY SPACE FIRE STATIONS.
Condition: Unknown
Due 13 March 1986
Resolved 13 March 1986
Navigation
Issued 13 March 1986
Resolved
RENEW LENS FOR STARBOARD BOW OBSTRUCTION LIGHT.
Condition: Unknown
Due 13 March 1986
Resolved 13 March 1986
Fire Fighting
Issued 13 March 1986
Resolved
CONDUCT ANNUAL FIRE EXTINGUISHER/FIXED SYSTEM SERVICING.
Condition: Unknown
Due 13 March 1986
Resolved 13 March 1986
Lifesaving
Issued 13 March 1986
Resolved
PROVIDE ON BOARD THE MODU THREE ADDITIONAL PARACHUTE FLARES FOR A TOTAL OF TWELVE FLARES.
Condition: Unknown
Due 13 March 1986
Resolved 13 March 1986
Documentation
Issued 13 March 1986
Resolved
CONDUCT ANNUAL CRANE SURVEY.
Condition: Unknown
Due 13 March 1986
Resolved 13 March 1986
Documentation
Issued 13 March 1986
Resolved
PROVIDE ON BOARD THE MODU A VALID IOPP CERTIFICATE AND PANAMANIAN OIL RECORD BOOK.
Condition: Unknown
Due 13 March 1986
Resolved 13 March 1986