Records from 2002 to 2025. Most recent: inspection, 17 October 2025.
Inspection history · 49
17 October 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8254751
2 October 2025
COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8236579
23 April 2025
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8117535
1 May 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7904061
14 March 2024
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7879172
24 May 2023
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7695822
24 May 2023
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7764315
20 May 2023
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7695124
2 May 2023
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7678732
28 September 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7567729
18 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7433022
13 April 2022
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7430448
22 March 2021
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7152025
15 May 2020
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7043771
24 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6839876
13 June 2018
DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6444448
14 May 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6414354
18 April 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6393993
10 April 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6388522
4 October 2017
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6280129
19 September 2017
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6285520
5 April 2017
DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6119178
28 February 2017
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6096467
26 January 2017
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6077506
14 March 2016
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5832991
19 May 2014
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5025684
14 May 2014
Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5025024
10 April 2009
MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3450116
20 March 2009
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3434922
9 July 2008
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3262675
23 May 2008
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3220317
31 March 2008
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3164645
17 October 2007
Hull Examination
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3077114
19 September 2007
Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3061274
29 March 2007
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2893515
10 January 2007
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2853678
11 July 2006
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2709553
7 April 2006
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2619584
10 October 2005
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2531952
20 April 2005
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2338573
6 April 2005
Annual Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2315515
13 July 2004
MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2134255
21 June 2004
MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2088789
2 April 2004
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2026166
12 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963436
5 March 2003
In-Service Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1752141
25 September 2002
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1679806
11 June 2002
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1627176
9 April 2002
Hull Examination · Initial Certification · Inclining Experiment · Construction Oversight
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1602919
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 1 May 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all engines that draw intake air from within the space. The installed pre-engineered fire system did not shut down the main engines during operational testing. Make repairs to the same and conduct an operational test of the system in the presence of a Marine Inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2024
Resolution: Witnessed satisfactory operation of the pre-engineered fixed fire extinguishing system machinery shut downs, alarms, and overrides.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 April 2019
Resolved
Heat sensor located outboard Port MDE is broken and needs to be replced. Heat sensor located inbopard STBD MDE has cracked plastic cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 1 May 2019
Resolution: Recieved update from vessel rep. System repaired and tested by Reliable.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 30 March 2016
Resolved
Provide onboard copy of Inland Navigation Rules, paper copy. 33 CFR 88.05
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 March 2016
Resolved 19 July 2016
Resolution: Electronic copy accepted by OCMI ([name withheld])
Lifesaving › Inflatable Liferafts › Not on Board
Issued 14 May 2014
Resolved
Installed missing 02 inflatable life rafts on vessel.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2014
Resolved 19 May 2014
Resolution: Inspected 02 installed inflatable life rafts
Electrical › Electrical Distribution System (emergency) › Outlet Box
Issued 14 May 2014
Resolved
Replaced GFCI outlets behind bar due to being improperly wired. Ensure GFCI outlets are operational & properly grounded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 19 May 2014
Resolution: Verified outlets were replaced behind bar and ensured they were wired properly.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2014
Resolved
Provide adequate means for vessel's hull to not carry current.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 19 May 2014
Resolution: Verified hull no longer carrying current.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 20 March 2009
Resolved
Prove proper operation of fire pump relay IAW 46 CFR 118.300(e)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 5 June 2009
Resolution: Fire pump relay was tested to ensure proper securing of pump from pilothouse.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 March 2009
Resolved
Ensure all ring life buoys are marked with retro reflective tape IAW 46 CFR 122.604(h)(i).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 5 June 2009
Resolution: Lifering on main deck had adequate retro reflective tape.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 20 March 2009
Resolved
Ensure all vent closures have capability of being kept closed IAW 46 CFR 115.830
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 5 June 2009
Resolution: Ventilation closures for E/R were fitted to remain closed and not swing open when vessel rolled.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 March 2008
Resolved
Provide metal supports for wiring in tank room above breaker panel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 23 May 2008
Resolution: Metal supports provided for wiring in tank room above breaker panel.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 31 March 2008
Resolved
Renew emergency lighting in aft engine room and tank room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 23 May 2008
Resolution: Emergency lighting in aft engine room and tank room renewed.
Engineering › Bilge Water Management System › Valve
Issued 31 March 2008
Resolved
Provide check valves in bilge system liness in fore peak and foward storage.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 23 May 2008
Resolution: Check valves in bilge system lines in fore peak and foward storage provided.
Operations/Management › Drills/Instruction › Fire
Issued 31 March 2008
Resolved
Properly post COI, stability letters, and fire control plan; so that they are visible to all passengers. IAW 46 CFR 116
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2008
Resolution: Owner sent pictures of posted Fire Control, COI, COD, and Stability letter.
Operations/Management › Drills/Instruction › Not Conducted
Issued 31 March 2008
Resolved
Properly conduct steering gear drills and log in book.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 22 April 2008
Resolution: Examinied updated document with steering gear drills added in for Captain''s sign off.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 31 March 2008
Resolved
Properly adjust dodgers or rescue platform to accomadate properly securing rescue platform.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 23 May 2008
Resolution: Rescue platform properly adjusted to accommodate proper securing.
Accommodation/Occupational Safety › Potable Water System › General
Issued 29 March 2007
Resolved
Repair leak in potable water system located in the tank room IVO the pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 April 2007
Resolved 17 October 2007
Resolution: Piping was re-sweated and no leak is present.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 7 April 2006
Resolved
Correct 2amp ground on switchboard panel. 46 CFR 120.372
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 5 June 2006
Fire Fighting › Firemans Outfit › Axe
Issued 7 April 2006
Resolved
mount fire axe in accordance with 46 CFR 118.600
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 17 May 2006
Navigation › Piloting/Steering › Marine Charts
Issued 7 April 2006
Resolved
Provide updated charts per 46 CFR 121.420
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 17 May 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 7 April 2006
Resolved
Prove proper operation of engine safetys in accordance with 46 FCR 115.804(i)
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 5 June 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 6 April 2005
Resolved
Prove proper operation of fixed CO2 shutdowns prior to carrying passagngers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2005
Operations/Management › Passenger Operations › Safety Orientation
Issued 6 April 2005
Resolved
Ammended COI to limit passanger count for CHIMS cold water policy.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2005
Resolution: VESSEL MEETS LIFESAVING REQUIREMENTS.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 April 2005
Resolved
Renew or replace all expire first aid items.
Action required: 705 - Other - as specified
Due 14 May 2005
Resolved 19 May 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 6 April 2005
Resolved
Provide receptacle and remove extension cord for the CO2 compressor.
Action required: 705 - Other - as specified
Due 14 May 2005
Resolved 19 May 2005
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 6 April 2005
Resolved
Carry only 216 total persons until 6 additional extended size life jackets are provided per 46 CFR 117.71.
Action required: 705 - Other - as specified
Due 14 May 2005
Resolved 19 May 2005
Engineering › Bilge Water Management System
Issued 5 March 2003
Resolved
Prove proper operation of audible signal for bilge alarm. Unit to be continuously monitored pending completion.
Due 10 May 2003
Resolved 21 May 2003
Documentation › Certificates/Documents
Issued 11 June 2002
Resolved
Provide documetation that your fixed fire fighting system was inspected sat. LEGACY COMPONENT DESC: Fire systems inspection documentation
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2002
Resolved 21 June 2002
Resolution: Completed.
Accommodation/Occupational Safety › Occupational Safety
Issued 11 June 2002
Resolved
Provide fire control plan to reflect all heat, smoke, fire detection systems. LEGACY COMPONENT DESC: Fire control plan
Condition: Unknown
Due 11 July 2002
Resolved 21 June 2002
Resolution: Corrected.
Documentation › Certificates/Documents
Issued 9 April 2002
Resolved
PROVIDE ON BOARD A VALID CERTIFICATE OF DOCUMENTION. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 9 April 2002
Resolved 9 April 2002
Documentation › Certificates/Documents
Issued 9 April 2002
Resolved
PROVIDE ON BOARD A VALID FCC STATION LICENSE. LEGACY COMPONENT DESC: FCC SSL
Due 9 April 2002
Resolved 9 April 2002
Navigation › Piloting/Steering
Issued 9 April 2002
Resolved
SWING COMPASS AND POST DEVIATION TABLE AT OPERATING STATION. LEGACY COMPONENT DESC: Compass Deviation Table
Due 9 April 2002
Resolved 9 April 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 April 2002
Resolved
INSTALL ADEQUATE GUARD IWO: PORT ENG (FRONT), PORT AND STBD SHAFT COUPLINGS.
Due 9 April 2002
Resolved 9 April 2002
Engineering
Issued 9 April 2002
Resolved
PROVE THAT PORT AND STBD GENERATOR'S F/O HOSE MEET SAE J1942 SPECS.
Due 9 April 2002
Resolved 9 April 2002
Resolution: PROVIDED APPROVED AND REQUIRED FIRE SLEEVES FOR SPECIFIC HOSES IN USE.
Electrical
Issued 9 April 2002
Resolved
PROVE THAT HOT WATER HEATER MEETS UL174 OR 1453 STANDARDS.
Due 9 April 2002
Resolved 9 April 2002
Resolution: PROOF PROVIDED BY MANUFACTURE.
Fire Fighting › Combustible Materials
Issued 9 April 2002
Resolved
OPERATION WITH PLASTIC CURTAINS ON MAIN NOT PERMITTED UNTIL ISSUE, AS DESCIBED IN THIS CASES' NARRATIVE, IS RESOLVED WITH LOCAL OCMI.
Due 9 April 2002
Resolved 9 April 2002
Resolution: UNAUTHORIZED SECTIONS OF CURTAINS PERMANENTLY REMOVED.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 9 April 2002
Resolved
RESOLVE SLIGHT OVERPRESSURIZATION ISSUE W/ SEA FIRE'S E/R FIRE SUPPRESSION BOTTLE. LEGACY COMPONENT DESC: Quantity of Gas
Due 9 April 2002
Resolved 9 April 2002
Resolution: SEA FIRE VERIFIED CONDITION SAT.