← All vessels
AMBASSADOR NORRIS
AMBASSADOR NORRIS is a 2001 tank ship. The Coast Guard has recorded 42 inspections since 2001, most recently in February 2020, along with 13 deficiencies and 8 operational controls.
Records from 2001 to 2020. Most recent: inspection, 13 February 2020.
- Built
- 2001
- Last inspected
- 13 February 2020
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9223722 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
H9AH
25004
Flag
PANAMA
—
Maury page id
psix-25004
Inspections, by type
…with no type recorded11
Years with a record
15 calendar years (2001–2020)
The 42 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it27955 - Convention (Subpart B), Gross Ton
45290 - Dead Weight, Metric Ton
55262 - Displacement, Metric Ton
11956 - Convention (Subpart B), Net Ton
27955 - Regulatory (Subpart C or D), Gross Ton
11956 - Regulatory (Subpart C or D), Net Ton
45290 - Dead Weight, Metric Ton
55262 - Displacement, Metric Ton
11956 - Convention (Subpart B), Net Ton
27955 - Regulatory (Subpart C or D), Gross Ton
11956 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 42
13 February 2020
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6908562
17 June 2019
Ballast Water Examination · Deficiency Check · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6716311
28 November 2018
Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6587484
12 April 2018
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6385663
4 September 2017
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6258895
2 December 2016
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6047638
10 February 2012
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4241962
27 January 2012
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4232054
23 January 2012
COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4229702
6 November 2010
COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3886205
11 December 2008
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3378401
17 July 2008
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3270577
14 July 2008
Deficiency Check · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3267997
29 May 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3221282
29 May 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3221451
20 September 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3061764
7 July 2007
Ballast Water Examination · MARPOL Annex I Examination · COC-CHEM Renew · ISPS III Exam · MARPOL Annex II Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2985850
10 August 2006
Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2743147
6 July 2005
ISPS III Exam · COC-CHEM Renew
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2416613
5 February 2005
MARPOL Annex I Examination · NPV Safety Exam · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2286761
30 January 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2283401
26 January 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2284629
24 December 2004
Ballast Water Examination · ISPS I Exam · NPV Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2263997
20 December 2004
ISPS I Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2262575
19 December 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2268521
12 November 2004
Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2239649
10 November 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2239710
10 November 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2306857
6 November 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2235981
3 July 2004
COC-CHEM Annual
Type not classified · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2119878
3 July 2004
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2119889
17 March 2004
Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2026125
3 June 2003
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1808700
17 January 2003
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1732070
30 November 2002
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1712462
20 November 2002
Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1708216
14 November 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1705557
22 August 2002
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1665036
26 June 2002
Certificate of Compliance · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1633668
14 January 2002
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1478279
25 May 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 290444
25 May 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1066859
Deficiency record · 13
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 28 November 2018
Resolved
To discharge ballast water into the waters of the United States, the master, owner, operator, agent or person in charge of a vessel subject to 151.2025 of this subpart must either ensure that the ballast water meets the ballast water discharge standard in 151.2030(a), use an AMS as described in 151.2025(a)(3), or ballast with water from a U.S. public water system, according to the schedule in paragraph (b) of this section.
Subject vessel, of keel laid date 14JUN2000 and ballast water capacity of 19,954 m3, is past its compliance date per the implementation schedule in 33 CFR 151.2035 (b). Currently, vessel’s installed BWTS is inoperative.
Vessel is not authorized to discharge untreated ballast into the waters of the U.S. without prior written authorization from the local Captain of the Port under the provisions of 33 CFR 151.2040 (b).
Cite: 33 CFR 151.2035
Action taken: 40c
Fire Fighting › Fire Main › Valves
Issued 12 April 2018
Resolved
0725 - Fixed fire extinguishing installation - A chemical tanker shall comply with the requirements of the International Bulk Chemical Code. Valves shall be provided in the foam main, and in the fire main where this is an integral part of the deck foam system, immediately forward of any monitor position to isolate damaged sections of those mains. PSCO observed both primary fire main isolation valves for the foam monitors as inoperable. 74 SOLAS(a) 2014 cons. VII/10 and IBC Code 11.3.10 Action Taken 17a
Fire Fighting › Fixed Deck Foam System › Main Control Station
Issued 2 December 2016
Resolved
1850-For tankers of 20,000 DWT and upwards, a fixed deck foam fire-fighting system shall be provided complying with the provisions of the Fire Systems Code. The first periodical control of foam concentrates stored on board should be performed after a period of three years and, after that, every year. PSCO observed that the annual foam concentrate test was overdue. 74 SOLAS(09) II-2/10.8.1.1; 50c
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 27 January 2012
Resolved
Each transfer pipe system used in a transfer to or from a vessel of 250 barrels or more in the U.S. waters must be tested under a static liquid pressure at least 1.5 times the MAWP annually. Cargo lines testing certificates from vessels recent yard period stated that the lines were pneumatically tested vice hydrostatically. Vessel is allowed a one time discharge of cargo but must provide results.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 23 January 2012
Resolved
1320-Anchoring devices-The condition of the ship and its equip shall be maintained to conform with the provisions of the present regs. PSCO observed several anchor chain links where the middle section was completely detached from the link. Provide clarification from cert issuing authority that this is an acceptable condition-SOLAS 74a, I/11
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 23 January 2012
Resolved
0899-Other (acid prevent)-Each transfer pipe system used in a transfer oil in the US must be hydrostatically tested to 1.5 times its MAWP annually. Cargo line testing certs from vsl stated that these lines were pneumatically tested. Vsl allowed one time discharge of cargo in NOLA, but must provide hydrostatic test prior to any future cargo ops in US-33 CFR 156.170
Deck/Cargo › Inert Gas System › Deck Mechanical Non-Return Valve
Issued 14 July 2008
Resolved
1899 - The vessel was unable to provide approval from the Marine Safety Center for the IGS dry type, double block and bleed deck seal. No loading cargoes requiring the use of the IG system in U.S. waters. Rectify deficiencies prior to next US port after sailing foreign to the satisfaction of the Coast Guard.
Documentation › Certificates/Documents › IOPP Certificate
Issued 14 July 2008
Resolved
Vessel's IOPP certificate does not list a tank for the retention of oily bilge water, however, the vessel has and is using a bilge water holding tank. Class is to attest to the vessels bilge arrangements and issue appropriate certificate.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 29 May 2008
Resolved
Vessels emergency generator fuel pump is inoperable. Vessel currently has temporary emergency generator set in container on deck and operating with 1 additional engine room watch stander at all times.
Navigation › Collision/Grounding Avoidance
Issued 30 November 2002
Resolved
Vessel was granted an inbound and outbound deviation approval for S-band radar. LEGACY COMPONENT DESC: Radar
Construction/Loadline › Markings
Issued 26 June 2002
Resolved
Paint hull markings in contrasting colors LEGACY COMPONENT DESC: Load Line Mark
Deck/Cargo › Inert Gas System
Issued 26 June 2002
Resolved
Prior to use of Inert Gas system in U.S. waters provide Cognizant Coast Guard with acceptance letter from MSC for double block and bleed arrangement
Pollution Prevention/Response
Issued 26 June 2002
Resolved
Remove excess waste drums from deck
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.