MAURY USCG vessel records Sign in
← All vessels

HEBEI COURAGE

HEBEI COURAGE is a 1985 tank ship. The Coast Guard has recorded 64 inspections since 1985, most recently in September 2007, along with 45 deficiencies and 9 operational controls.

Records from 1985 to 2007. Most recent: inspection, 26 September 2007.

Built
1985
Last inspected
26 September 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8116934 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
250137
Flag
LIBERIA
—
Maury page id
psix-250137

Inspections, by type

…with no type recorded39
Years with a record 22 calendar years (1985–2007)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it20416 - Convention (Subpart B), Net Ton
20416 - Regulatory (Subpart C or D), Net Ton
70922 - Dead Weight, Ton
83804 - Displacement, Ton
42009 - Convention (Subpart B), Gross Ton
42009 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ASTRON SPIRIT Freight Ship · MISLE 239947 · 19 August 1998 · activity 63105

Inspection history · 64

26 September 2007 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3061478
9 June 2007 MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2949462
8 June 2007 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2949399
4 October 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2794169
8 August 2006 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2740271
15 March 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2603279
13 March 2006 PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2595849
6 March 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2596627
22 February 2005 PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2296663
16 February 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2294157
12 February 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2291393
28 January 2005 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2282326
7 January 2005 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2270716
3 January 2005 Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2267781
3 January 2005 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2268002
18 December 2003 Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1966323
17 November 2003 Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1949525
16 November 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1949519
15 November 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1949832
7 November 2003 Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1945200
16 April 2003 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1774606
3 February 2003 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1739194
23 October 2002 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1694992
28 August 2002 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1667626
7 August 2002 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1666683
3 April 2002 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1600434
30 March 2002 Certificate of Compliance · Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1599334
1 March 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 287533
18 September 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 282265
2 May 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 427967
2 May 1999 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 793053
19 August 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 63105
6 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 424296
29 December 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 411454
29 December 1997 Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 784330
12 November 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 396772
9 November 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 397384
6 October 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 383640
15 July 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 380428
8 July 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 380406
22 August 1994 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1175821
2 July 1994 Tank Vessel Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 861042
7 January 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 523101
3 June 1993 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1135467
20 November 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 465345
22 September 1992 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 484592
13 February 1992 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 959534
9 September 1991 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 345822
7 May 1991 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 343664
6 March 1991 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 925829
1 February 1990 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 335109
3 November 1989 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1216554
4 June 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 487804
12 October 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 326165
12 October 1988 Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1199540
6 June 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 502363
9 October 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 318941
9 October 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1012376
9 October 1987 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1014362
19 December 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 471030
10 May 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 308752
12 September 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 304154
15 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291113
6 May 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 439898

Deficiency record · 45

Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 13 March 2006 Resolved
Ceiling in meat and fish freezer delaminated ILO 147 / Ports & Waterways Safety Act
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 8 August 2006
Resolution: Received class report from China Classification Society satisfying requirements.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 March 2006 Resolved
Catwalks between cargo holds unsafe and deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 8 August 2006
Resolution: Received class report from China Classification Society satisfying requirements.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 13 March 2006 Resolved
Hand rail missing to fuel oil inlet to boiler.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 8 August 2006
Resolution: Received class report from China Classification Society satisfying requirements.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 March 2006 Resolved
Uninsulated Power wire to washing machine in close proximity to open community showers. SOLAS 74/78 II/1 Reg. 45
Condition: Improper Installation
Due 13 March 2006
Resolved 13 March 2006
Resolution: Exposed wire secured and relocated.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 22 February 2005 Resolved
Portside protective guide to chain cables is torn and inclined.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 February 2005
Resolved 22 February 2005
Resolution: Received class report from CCS satisfying requirement.
Electrical › Electric Generation Source (emergency) › Generator
Issued 3 January 2005 Resolved
Emergency generator is leaking cooling water from a crack in the engine block. Class to survey and determine repairs required prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2005
Resolution: Rcvd class report via fax. The crack frame of emerg. generator diesel engine temporarily repaired by welding and stuffing with Plastic Steel Putty. No leakage was found during running test. Permanent repair by 03MAR05, observe item on next PSC boarding.
Engineering › Fuel Oil Service System › Flange
Issued 3 January 2005 Resolved
Main engine is leaking fuel oil from flange on starboard forward. Insulation oil soaked, oil leaking on electric cables. Class to atest to repair prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2005
Resolution: Received report from class via fax. The leaking fuel oil pipe on stbd forward of main engine has been repaired and wrapped by insulation to satisfaction.
Engineering › Steam System (main) › Piping
Issued 3 January 2005 Resolved
Steam pipes on main deck have several leaks. Expansion joints near holds #7, #6, #4 leaking, class to survey entire main deck steam system. Class to determine repairs required prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2005
Resolution: No.4,6,&7 expansion joints of steam pipes on main deck portside repaired temp. after complete inspection which required by PSC & sat. anchor op. test. Required No.1,2,3,4,5,6&7 expansion joints and holed pipes (4 pcs) to be repaired or renewed by 03MAR05
Engineering › Diesel Engine (propulsion-direct drive) › Valve, Pilot (air start)
Issued 3 January 2005 Resolved
Vessel experienced two main engine casualties while entering port. Class to attest to proper operation of main engine prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2005
Resolution: Received class report via fax. No. B2 cylinder starting valve renewed, main starting valves, the main starting air piping cleaned and all 12 pcs starting air pilot valves overhauled and cleaned to satisfaction.
Construction/Loadline › Hull › Bracket
Issued 3 January 2005 Resolved
#4 hold has cracked bracket forward center. Bracket cracked where welded to deck. Class to survey and attest to repairs.
Action required: 705 - Other - as specified
Due 2 February 2005
Resolved 28 January 2005
Resolution: Rcvd class report. #4 hold bracket repaired to the satisfaction of the attending class surveyor.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 January 2005 Resolved
Hand rail broken in engine room. Hand rail near top of engine port side. Class to survey and attest to repairs.
Action required: 705 - Other - as specified
Due 2 February 2005
Resolved 4 January 2005
Resolution: Received class report via fax. The broken handrail in Engine Room second platform fixed by welding and found satisfactory.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 3 January 2005 Resolved
Hospital does not have call button or telephone. Install call button or telephone and class surveyor to attest to installation.
Action required: 705 - Other - as specified
Due 2 February 2005
Resolved 28 January 2005
Resolution: Rcvd class report. Telephone has been installed in Hospital and tested satisfactory.
Engineering › Diesel Engine (auxiliary)
Issued 17 November 2003 Resolved
The No. 2 diesel generator has a pinhole leak on the fuel oil supply manifold between the #2 and #3 fuel oil injection pumps. Repair manifold permanently to the satisfaction of class. LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2003
Resolved 18 December 2003
Resolution: Received class report from China Classification Society satisfying requirement.
Engineering › Diesel Engine (auxiliary)
Issued 17 November 2003 Resolved
The No. 1 diesel generator has a minor fuel oil leak on the #3 fuel oil injection pump supply pipe at the manifold connection. Repair to satisfaction of class. LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 18 December 2003
Resolution: Received class report from China Classification Society satisfying requirement.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 7 November 2003 Resolved
Maintenance of ship and equipment. Fix and repair fuel and oil leaks on #1 Main generator. Have class inspect and approve repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2003
Resolution: Reviewed class report and verified leaks were repaired.
Fire Fighting › Fire Pumps
Issued 16 April 2003 Resolved
THE PRIME MOVER FOR THE EMERGENCY FIRE PUMP IS LEAKING LUBE OIL FROM THE CYLINDER HEAD. BOTH FUEL INJECTOR, FUEL OIL RETURN LINES DRAIN INTO THE BILGE. REPAIR AND PROVE PROPER OPERATION.
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 18 April 2003
Resolution: RECEIVED CLASS REPORT ATTESTING TO PROPER REPAIR.
Electrical › Electric Generation Source (emergency)
Issued 16 April 2003 Resolved
THE EMERGENCY GENERATOR IS LEAKING JACKET WATER FROM AN APPARENT TEMPORARY REPAIR ON THE PORT SIDE OF THE ENGINE BLOCK. REPAIR AND PROVE PROPER OPERATION.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 18 April 2003
Resolution: RECEIVED CLASS REPORT ATTESTING TO PROPER REPAIR.
Navigation › Collision/Grounding Avoidance
Issued 16 April 2003 Resolved
PROVIDE AN ECHO SOUNDER RECORDER AS REQUIRED BY 33 CFR 164.35. LEGACY COMPONENT DESC: Echo-sounding Device Recorder
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 7 November 2003
Resolution: Cleared deficiency.
Deck/Cargo › Inert Gas System
Issued 30 March 2002 Resolved
During external inspection IGS deck seal (wet), found the same empty. Crew could no refill, as inlet water valve was malfunctioning. Vessel is to repair and have class inspect the same. LEGACY COMPONENT DESC: Water Seal
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 1 April 2002
Resolution: entire IGS system examined, deck seal found defects rectified by crew, entire system including alarms tested and all found to perform satisfactory.
Deck/Cargo › Inert Gas System
Issued 30 March 2002 Resolved
Before any cargo operations are to be conducted in US waters, with a commodity requiring an IGS (flashpoint below 60C) for safe ops, a class report is to be faxed to the USCG stating that NY01 has been corrected.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2002
Resolution: entire IGS system tested and found to work satisfactory for cargoes having flash point less than 60 degrees C. and vessel is considered safe for the carriage of grade "B" and lower cargoes.
Construction/Loadline › Hull
Issued 30 March 2002 Resolved
Replace all missing securing bolts on ships centerline stanchions. LEGACY COMPONENT DESC: Railing/stanchion
Condition: Improper/Lack of Maintenance
Due 30 April 2002
Resolved 28 August 2002
Resolution: CLEARED BY CLASS VIA FAX
Deck/Cargo › Mooring/Anchoring
Issued 30 March 2002 Resolved
Repair wasted steamline support (portside). LEGACY COMPONENT DESC: Piping steam line
Condition: Improper/Lack of Maintenance
Due 30 April 2002
Resolved 28 August 2002
Resolution: CLEARED BY CLASS VIA FAX
Lifesaving
Issued 1 March 2001 Resolved
REPLACE/REPAIR PORT & STBD EMBARKATION LADDERS FOR LIFEBOATS & LIFERAFTS.LADDERS WASTED. CLASS TO ATTEST TO PROPER REPAIRS OR FAX A COPY OF RECEIPT FOR NEW EMBARKATION LADDERS TO [phone withheld] OR 24 HR NUMBER. LADDERS TO BE FITTED IAW SOLAS 74 (A) REG II/7. SOLAS 74 (A)II/48.7
Condition: Unknown
Due 24 April 2001
Resolved 24 April 2001
Electrical
Issued 18 September 2000 Resolved
Inert Gas oxygen analyzer cannot be properly calibrated (SOLAS 74/Reg 62 (m); Repair analyzer prior to discharging cargo.
Condition: Unknown
Due 18 September 2000
Resolved 22 September 2000
Lifesaving
Issued 2 May 1999 Resolved
Lifeboats not fitted with bowsing tackle. Solas 74 Chapt III Reg 28. Place bowsing tackle onboard prior to 02 Jun 99.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Documentation
Issued 9 November 1996 Resolved
VESSEL IS TO HAVE ON BOARD USCG APPROVED VESSEL RESPONSE PLAN, RECENTLY APPROVED SOPEP, AND COFR PRIOR TO DEPARTURE FROM HOUSTON, TX, ON BOARD PRIOR TO DEPARTURE FROM HOUSTON, TX. VESSEL'S SHIPPING AGENT CURRENTLY HOLDS THESES DOCUMENTS AND WILL DELIVER THEM UPON ARRIVAL.
Condition: Unknown
Due 2 December 1996
Resolved 2 December 1996
Fire Fighting
Issued 6 October 1995 Resolved
MAKE PERMANENT REPAIRS TO FIRE MAIN SYSTEM WHERE TEMPORARY PATCHES ARE LOCATED (PORTSIDE OF #7 CARGO TANK). PROVIDE COAST GUARD WITH CLASS SURVEYORS REPORT (NKK).
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Deck/Cargo
Issued 6 October 1995 Resolved
PRIOR TO LOADING LIQUID CARGOES, REPAIR AND TEST EACH CARGO TANK FOR PROPERAIR TIGHT SEAL. PROVIDE COAST GUARD WITH CLASS SURVEYORS REPORT (NKK).
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Navigation
Issued 8 July 1995 Resolved
Demonstrate hydraulic fluid low level visual alarm for steering gear motor reservoir operates properly on navigating bridge. Provide flag/class report of satisfactory operation.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Deck/Cargo
Issued 2 July 1994 Resolved
PRIOR TO LOADING CARGOS REQUIRING HIGH LEVEL ALARMS, DEMONSTRATE PROPER OPERATION OF BOTH HIGH LEVEL ALARMS.
Condition: Unknown
Due 2 July 1994
Resolved 2 July 1994
Lifesaving
Issued 2 July 1994 Resolved
AT NEXT U.S. PORT DEMONSTRATE PROPER OPERATION/CALIBRATION OF ALL PORTABLEOXYGEN METERS.
Condition: Unknown
Due 2 July 1994
Resolved 2 July 1994
Fire Fighting
Issued 2 July 1994 Resolved
REPLACE ALL EXISTING NON-APPROVED FIREMAN'S TENDING LINE WITH SOLAS APPROVED LINES.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Construction/Loadline
Issued 2 July 1994 Resolved
PRIOR TO DEPARTURE, OFF-LOAD CARGO GAS FREE PIPE TUNNEL, HAVE CLASS SURVEYOR DETERMINE SOURCE OF DETECTED GAS AND SUBMIT CORRECTIVE PROPOSAL TOUSCG [name withheld] REPAIRS (IF NEEDED).
Condition: Unknown
Due 3 September 1994
Resolved 2 August 1994
Lifesaving
Issued 2 July 1994 Resolved
DEMONSTRATE PROPER CALIBRATION OF ALL LEL METER PRIOR TO NEXT U.S. VOYAGE (NEXT U.S PORT).
Condition: Unknown
Due 2 July 1994
Resolved 2 July 1994
Fire Fighting
Issued 3 June 1993 Resolved
PROVIDE ONBOARD DOCUMENTATION THAT SELF CONTAINED BREATHING APPARATUS HAS BEEN PROFESSIONALLY SERVICED.
Condition: Unknown
Due 4 June 1993
Resolved 8 June 1993
Documentation
Issued 7 May 1991 Resolved
A VIO OF 33CFR155.750 IN THAT THE OTP REQUIRED BY 33CFR155.720 WERE INCOMPLETE IN THAT THEY DID NOT CONTAINED THE MEANS OF COMMUNICATION AS REQUIRED BY 33CFR155.750(A)(6)._x001C_ _x001C_
Condition: Unknown
Due 10 September 1991
Resolved 10 September 1991
Documentation
Issued 7 May 1991 Resolved
A VIO OF 33CFR155.750 IN THAT THE OTP REQUIRED BY 33CFR155.720 WERE INCOMPLETE IN THAT THEY DID NOT CONTAIN PROCEDURES AND DUTY ASSIGNMENTS FORTENDING THE VSLS MOORING LINES DURING OIL TRANSFER AS REQUIRED BY 33CFR155.750(A)(5).
Condition: Unknown
Due 31 July 1991
Resolved 31 July 1991
Navigation
Issued 7 May 1991 Resolved
A VIO OF 33CFR164.30 IN THAT THE UK LIGHT LIST (NP:82 VOLJ) USED BY THE VSLWAS NOT CORRECTED THRU NTMS 7/91, WHICH WERE REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSLS RTE FROM SMITH PT VA TO BALTO HARBOR. NO U.S. EQUIVALENT O/B._x001C_
Condition: Unknown
Due 10 September 1991
Resolved 10 September 1991
Documentation
Issued 7 May 1991 Resolved
A VIO OF 33CFR155.750 IN THAT THE OTP REQUIRED BY 33CFR155.720 WERE INCOMPLETE IN THAT THEY DID NOT CONTAIN A LIST OF EACH PRODUCT TRANSFERRED AS REQUIRED BY 33CFR155.750(A)(1)(1)._x001C_ _x001C_
Condition: Unknown
Due 31 July 1991
Resolved 31 July 1991
Navigation
Issued 6 March 1991 Resolved
Demostrate proper operation of the ARPA at the next U.S. port.
Condition: Unknown
Due 6 March 1991
Resolved 6 March 1991
Navigation
Issued 1 February 1990 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE FOREIGN EQUIVALENT TO U.S. CHART 12278 &12281 (UK:2850) USED BY THE VSL WAS NOT CORR UP THRU NTMS 2565, WHICH WERE REASONABLY AVAILABLE AND CONTAINED CORRS APPLICABLE TO THE VSLS ROUTE FROM SMITH PT, VA TO BALTIMORE HBR. NO U.S. EQUIVALENT ONBOARD.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Navigation
Issued 1 February 1990 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE U.S. CHARTS 12230 AND 12263, USED BY THEVSL WERE NOT CORR UP THRU NTMS 25/89 AND 38/89, RESPECTIVELY WHICH WERE REASONABLY AVAILABLE AND CONTAINED CORRS APPLICABLE TO THE VSLS ROUTE FROM SMITH PT, VA TO BALTIMORE HBR. NO FOREIGN EQUIVALENT ONBOARD.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Navigation
Issued 12 October 1988 Resolved
33 CFR 166.33(A)(1) THE VESSEL DID NOT HAVE ON BOARD MARINE CHARTS OF THE AREA TRANSITED (BOSTON INNER HARBOR AND APPROACHES).
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Deck/Cargo
Issued 9 October 1987 Resolved
CARGO PIPING STATIC LIQUID PRESSURE TEST INSUFFICIENT.
Condition: Unknown
Due 9 October 1987
Resolved 9 October 1987
Navigation
Issued 10 May 1986 Resolved
VESSEL DID NOT HAVE A CURRENT OR CURRENTLY CORRECTED, U.S. OR FOREIGN GOV'TEQUIVALENT MARINE CHART OF THE AREA BEING TRANSITED (LOCAL CHART 11347) ON BOARD AS REQUIRED BY 33CFR164.33(A)(1)(I). VESSEL HAD ONE ON BOARD PROIR TOSAILING.
Condition: Unknown
Due 10 May 1986
Resolved 10 May 1986

Ownership record