Documentation record
Registered dimensions (L × B × D)46.7 ft × 15.2 ft × 6.2 ft
Registered tonnagegross 45 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDMR YACHTS INC · ARUNDEL, ME, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un
DocumentationValid · issued 13 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31 - Regulatory (Subpart C or D), Net Ton
45 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
22 May 2025
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8116930
9 April 2025
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8108577
3 September 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7995530
31 August 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7781226
14 April 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7645990
1 June 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7465726
4 June 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7215687
3 May 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7187868
1 April 2021
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7167178
4 June 2020
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6965600
23 July 2019
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6758486
15 May 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6684618
14 June 2018
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6444337
22 May 2017
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6212006
24 April 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6131663
18 May 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5880601
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 22 May 2025
Resolved
THE MARINE EMPLOYER MUST HAVE O/B A SUFFICIENT # OF ALCOHOL TESTING DEVICES READILY ACCESSIBLE. MI'S FOUND NO ALCOHOL TEST SWABS O/B. PROVIDE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 9 June 2025
Resolution: Vessel rep provided alcohol swabs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 May 2025
Resolved
AN ADULT LIFEJACKET MUST BE PROVIDED FOR EACH PERSON CARRIED. MI'S FOUND 1 MISSING ADULT LIFEJACKET. LIMITED TO 66 PERSONS UNTIL PROVISION...
Action required: 705 - Other - as specified
Resolved 9 June 2025
Resolution: Vessel rep provided one lifejacket.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 May 2025
Resolved
EACH VESSEL MUST HAVE O/B An FCC CAT 1 EPIRB, INSTALLED TO AUTOMATICALLY FLOAT FREE. MI'S FOUND EPIRB W/O HYDROSTATIC RELEASE EXPIRATION DATE MARKED... PROVIDE DOCUMENTATION OF VALIDITY.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 9 June 2025
Resolution: Vessel rep provided float free date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 August 2023
Resolved
Electrical equipment exposed to weather must be watertight. Vessel had deck light hat was flooded from the inside causing an electrical hazard.
46 CFR 183.210(b)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2023
Resolved 5 September 2023
Resolution: vessel sent reciept and picture of the newly replaced light. All satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 May 2021
Resolved
Fuel hose end fittings must comply with SAE J-1475 (incorporated by reference; see 46CFR175.600).
Port side fuel tank supply line fitting did not comply with SAE J-1475.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 10 May 2021
Resolution: Owner submitted pictures of receipt and installation of new hose with correct fitting.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessels from electrical hazards, including fire caused by or originating in electrical equipment and electrical shock.
Electrical wiring connections are not secured inside an electrical enclosure.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 13 May 2021
Resolution: Owner submitted pictures of wires re-routed to inside an enclosure.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2021
Resolved
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards.
Engine room fwd bulkhead has a wire pentration in the bulkhead without a fire retardent seal.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 10 May 2021
Resolution: Bulkhead penetration in engine room has been sealed with approved type sealant.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 July 2019
Resolved
Vessel did not have updated lightlist. Required updated lightlist.
46CFR184.420
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2019
Resolved 8 August 2019
Resolution: vessel owner purchased new lightlist.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 July 2019
Resolved
Vessel did not have updated charts onboard. Required vessel to have updated charts.
46CFR184.420
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2019
Resolved 8 August 2019
Resolution: vessel owner purchased new chart for area of operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 July 2019
Resolved
Life ring was not in servicable condition. Required vessel to replace life ring with servicable one.
46CFR180.70
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2019
Resolved 8 August 2019
Resolution: vessel owner replaced life ring.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 14 June 2018
Resolved
A life float must be provided with a water-light that meets 46CFR161.010. Upon inspection it was identified that the battery installed was not an approved battery. Battery must be replaced by an approved battery.
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 22 June 2018
Resolution: Vessel relaced battery with approved type.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 June 2018
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed hazardous. Both port and starboard engines had exposed rotating gears. Guards must be provided to protect rotating gear.
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 22 June 2018
Resolution: Vessel attached guards around rotating gear.
Navigation › Piloting/Steering › Marine Charts
Issued 14 June 2018
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Vessels chart was not kept up-to-date. Vessel must provide up-to-date chart for intended voyage.
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 22 June 2018
Resolution: Vessel provided new chart
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 June 2018
Resolved
Alcohol test strips must be available within 2 hours of a marine casualty. Vessel did not have alcohol test strips on board. Vessel must provide DOT approved alcohol test strips.
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 22 June 2018
Resolution: Vessel provided DOT approved alcohol test strips.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 June 2018
Resolved
Vessel must meet the provide proof of enrollment and written company policy to meet the requirements of the Drug and Alcohol Program. Vessel did not have required documentation on-board. Vessel must provide evidence of compliance with the Drug and Alcohol Program.
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 22 June 2018
Resolution: Vessel provided documentation on DAPI enrollment.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 June 2018
Resolved
Vessel must provide suitable covers for all exposed hazards. Vessel was missing part of the cover for the exhaust on the starboard side engine. Vessel must provide cover.
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 23 June 2018
Resolution: Vessel provided fiberglass wrap for exhaust system.
Lifesaving › Hand Flares › Quantity
Issued 14 June 2018
Resolved
Vessel must have an additional 2 red and 1 orange hand flare.
Action required: 10 - Deficiency Rectified
Due 22 June 2018
Resolved 15 June 2018
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 May 2016
Resolved
SH01: Post COI in location visible to passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 8 June 2016
Resolution: COI posted.
Communications › Radio Communications › EPIRB
Issued 18 May 2016
Resolved
SH02: Hydrostatic release on EPIRB shows it is expired, although operator claims to have incorrectly filled it out as the install date, not expiration date. Show proof of purchase/install or replace.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 8 June 2016
Resolution: Installed new hydrostatic release
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 May 2016
Resolved
SH03: Electrical connections, in Engine Room, must be made in a box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 8 June 2016
Resolution: Connections were placed inside a box.