ISLAND CURRENT is a 1984 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in April 2026, along with 37 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 21 April 2026.

Built
1984
Last inspected
21 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA3380
250180
Flag
UNITED STATES
Maury page id
psix-250180

Documentation record

Registered dimensions (L × B × D)36.7 ft × 12.7 ft × 5.6 ft
Registered tonnagegross 18 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGLOUCESTER MARINE INC · GLOUCESTER, VA, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCITY ISLAND, NY
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 4 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Net Ton
18 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

21 April 2026 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8352962
8 April 2026 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8324632
5 May 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8128548
11 April 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8013897
28 March 2024 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7857205
8 May 2023 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7683934
22 April 2023 Type not recorded
No type recorded · Station Kings Point · USCG Northeast District (CGD-NE) · Activity 7714718
31 January 2023 Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7630001
22 April 2022 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7430403
23 March 2022 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7417305
18 May 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7200389
1 September 2020 DAPI Audit · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7047263
24 August 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7041560
13 January 2020 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6887992
15 May 2019 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6684619
30 April 2018 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6402228
28 February 2018 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6392272
25 May 2017 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6154096
14 July 2016 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5940194
22 February 2016 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5819555

Deficiency record · 37

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 April 2026 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessels First Aid was missing contents. Replace First Aid Kit. 46CFR184.710
Action required: 705 - Other - as specified
Resolved 23 April 2026
Resolution: recieved photo evidence rectifing first aid kit deficencies.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 May 2025 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (2) For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Satisfactory servicing report is not available. Additionally, hydrostatic testing of cylinder is required due to extent of corrosion. 46 CFR 176.810 (b)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2025
Resolution: Recieved satisfactory video and images of fireboy system function w/ regard to MDE and GEN S/D. Cylinder was replaced by fire protection company.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 May 2025 Resolved
A pre-engineered fixed gas fire extinguishing system must: (4) Be installed in accordance with the manufacturer's instructions. FWD Engine Room bulkhead contains multiple open penetrations, required to be sealed for the system to be effective in case of discharge. 46 CFR 181.420 (a)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2025
Resolution: Recieved pictures from Operator showing penetrations sealed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 May 2025 Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. Port diesel tank fill pipe bonding is disconnected. 46 CFR 182.20-30 (d) (Old-T)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2025
Resolution: Recieved email from Operator with picture attesting to repair completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 May 2025 Resolved
Circuit breakers, of the proper voltage rating, shall be of the manually reset type designed for inverse time delay, instantaneous short circuit protection and capable of repeatedly opening the circuit in which it is to be used without damage to the circuit breaker. Unable to verify proper size of circuit breaker serving the oil change pump. Additionally the circuit breaker is taped in the closed position. 46 CFR 183.05-30 (Old-T)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2025
Resolution: Recieved email and pictures from Operator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 May 2025 Resolved
A submersible electric bilge pump may be used as a power bilge pump, provided that: (3) The pump is permanently mounted. Bilge pump is not permanently affixed. 46 CFR 182.520(e)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2025
Resolution: Recieved pictures from Operator of bilge pump affixed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 May 2023 Resolved
A vessel certificated to operate on lakes, bays, and sounds route within one mile of land is not required to carry survival craft. Vessel's survival craft was found damaged and worn at the time of inspection. In cold water, vessel is restricted to operating within one mile of land until satisfactory repairs are made on the survival craft.
Action required: 705 - Other - as specified
Resolved 30 May 2023
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 September 2020 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. EPIRB did not have a battery expiration date on unit as required. HRU did not have the expiration date marked properly. 46 CFR 176.808
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2020
Resolved 14 September 2020
Resolution: Received satisfactory picture attesting to proper repair.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 September 2020 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The fist aid was not IAW 46 CFR 160.041.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2020
Resolved 14 September 2020
Resolution: Received satisfactory picture attesting to proper repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 September 2020 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Dead end wire located in after engine compartment. 46 CFR 183.340 (g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2020
Resolved 14 September 2020
Resolution: Received satisfactory picture attesting to proper repair.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 15 May 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 12 June 2019
Resolution: Recieved photo of Marine Operator Permit
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 May 2019 Resolved
A visual and audible alarm must be provided at the operating station. Engine room audible and visual bilge alarm is inoperable. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2019
Resolved 17 May 2019
Resolution: witnessed audible and visual alarm
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 15 May 2019 Resolved
Conduct satisfactory fire and abandon ship drill in the presence of a Marine Inspector. 46 CFR 185.520
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2019
Resolved 17 May 2019
Resolution: witnessed satisfactory fire and abandon ship drill
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 May 2019 Resolved
Vessel must carry first aid kit that is approved under 160.41. Vessel needs correct first aid kit. 46 CFR 184.710
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 13 June 2019
Resolution: Recieved photo of new first aid kit
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 May 2019 Resolved
An exterior lighting fixture operating more than 50 volts must comply with UL 595. Provide UL specs for newly installed lights. 46 CFR 183.410(d)
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 2 July 2019
Resolution: Recieved report
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 May 2019 Resolved
The wires on the forward lights on upper mast, connection must be made within an enclosure. 46 CFR 183.340(g) 17JUN2019 - due date extended to 21JUN2019.
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 27 June 2019
Resolution: Recieved photo of proper electrical enclosure
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2019 Resolved
A vessel not required to have a driven power fire pump must have three 2 1/2 gallon buckets with an attached lanyard. Vessel was missing 2 fire buckets. 46 CFR 181.610 17JUN2019 - def changed to action code of 701C due to the O/O not having rectified the def.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2019
Resolved 27 June 2019
Resolution: Recieved photo of fire buckets
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 May 2019 Resolved
Wires for lights in pilot house must be made within an enclosure. 17JUN2019 - due date extended to 21JUN2019.
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 27 June 2019
Resolution: Recieved photo of proper electrical enclosure
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2019 Resolved
A vessel of more than 26ft but not more than 65ft must carry a minimum of one life buoy of not less than 24 inches. Vessel has incorrect buoy size. 46 CFR 180.70
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 17 June 2019
Resolution: Ring life buoy and floating waterlight were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 May 2019 Resolved
A vessel must carry one floating water light, Vessel's waterlight is cracked and needs replaced. 46 CFR 180.70(d)
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 17 June 2019
Resolution: Ring life buoy and floating waterlight were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 May 2019 Resolved
Paddles for life float must be at least 4ft in length and lashed to life float. Vessel need new paddles. 46 CFR 180.175(f)(2)
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 29 May 2019
Resolution: Recieved photo of new paddles
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 May 2019 Resolved
Cover anchor line hole to maintain watertight integrity. 46 CFR 179.360
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 13 June 2019
Resolution: Recieved photo of patched hole
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 May 2019 Resolved
Guard rails on bow are loosed and need to be tighten. No passengers allowed on bow until repairs have been made. 46 CFR 176.830
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 27 June 2019
Resolution: Rails tightened
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 May 2019 Resolved
Clean knife edge of scuttles to maintain watertight integrity. Remove fish scales. 46 CFR 179.360
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 12 June 2019
Resolution: Recieved photo of clean knife edges
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 May 2019 Resolved
Monthly inspections required by NFPA 10 of portable extinguishers need to be conducted. No monthly inspections of portable extinguishers were completed. 46 CFR 176.810(b)(1)(ii)
Action required: 705 - Other - as specified
Due 22 May 2019
Resolved 12 June 2019
Resolution: Recieved photo of inspection tags on extinguisher
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 30 April 2018 Resolved
Each vessel that has on board an EPIRB installed must be allowed to automatically float free and activate. EPIRB housing cover is installed so that it cannot be removed and automatically release the EPIRB. EPIRB housing must be reinstalled one inch above its current position to allow the cover to release automatically.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2018
Resolved 6 August 2018
Resolution: Observed satisfactory installation of EPIRB for float-free arrangement.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 30 April 2018 Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers. Vessel does not have required EAP documentation, which includes display and distribution of a community service hotline telephone number for crewmember assistance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2018
Resolved 30 May 2018
Resolution: Received adequate documentation of required EAP documentation.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 April 2018 Resolved
The Certificate of Inspection must be posted under glass such that all pages are visible. Vessel has old version of COI posted, and needs to repost using current COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2018
Resolved 6 June 2018
Resolution: Received documentation showing COI posted for passenger viewing.
Navigation › Piloting/Steering › US Coast Pilot
Issued 30 April 2018 Resolved
A vessel must carry adequate and up-to-date U.S. Coast Pilot. Vessel does not have updated 2018 version of U.S. Coast Pilot publication.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2018
Resolved 6 June 2018
Resolution: Received documentation showing new Coast Pilot publication onboard the vessel.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 25 May 2017 Resolved
Vessel has only 13 lifejackets onboard, vessel may not operate with more than 13 passengers until proper amount are onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 30 April 2018
Resolution: Confirmed vessel had required 19 adult and 02 child lifejackets aboard.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 25 May 2017 Resolved
Vessel is required to have all 120v wiring to have double pole breakers or ground detection/ current meter.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 6 August 2018
Resolution: Observed satisfactory test of ground detection system.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 29 February 2016 Resolved
Clean bilges and remove all oil and water. Make available for in spection PTCHE
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 14 July 2016
Resolution: Bilges clean of oil and water.
Engineering › Reduction Gearing/Clutches › Hose
Issued 22 February 2016 Resolved
Replaced wasted RED Gear hyd hose. Hose to cooler wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 29 March 2016
Resolution: Hose replaced with approved material type.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 22 February 2016 Resolved
Replaced rusted/wasted sterntube to stuffing box clamps and nuts/bolts. PTCHE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 29 March 2016
Resolution: Hardware replaceded
Stability › Watertight Integrity › General
Issued 22 February 2016 Resolved
Both deck hatches for Lazz compartment and Fwd of generator compt inop. Repair or replace hatches. Show proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 29 March 2016
Resolution: Both hatches where cleaned and operates freely.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 22 February 2016 Resolved
Not available for inspection. Make availbe PTCHE
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 29 March 2016
Resolution: Propeller installed and SAT.
Engineering › Diesel Engine (auxiliary) › Cylinder
Issued 22 February 2016 Resolved
SSDG removed from vessel. Make availabe for inspection PTCPFH
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 14 July 2016
Resolution: Inspected by CG MI's onscene.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.