Records from 2015 to 2026. Most recent: inspection, 29 June 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 June 2026
Resolved
Floating waterlight battery was found expired. Replace floating waterlight battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 June 2026
Resolved
Battery terminal junction on forward engine room bulkhead was not protected against accidental contact. Provide cover to prevent accidental contact with terminals.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2025
Resolved
Floating water light battery was found expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 June 2024
Resolved
Vessel was found short 2 lifejackets from the required count. Provide 2 additional lifejackets in accordance with the maximum passenger count.
Action required: 705 - Other - as specified
Resolved 9 July 2024
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 July 2023
Resolved
Fire pump output was insufficient with the current configuaration of collapsible hose. Replace pump and hose to increase output of installed firepump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 September 2023
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 11 October 2022
Resolved
Current COD was not on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 October 2022
Resolved
Aft life ring was found blocked by miscellaneous equipment stored around and on top of life ring.
Action required: 10 - Deficiency Rectified
Resolved 11 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2022
Resolved
Fuel system shut off valves were not marked.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 October 2022
Resolved
Portable fire extinguisher in engine room was found with an unsued wire wrapped around the extingusisher and bracket.
Action required: 10 - Deficiency Rectified
Resolved 11 October 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 October 2022
Resolved
First aid kit was found with no aspirin.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 November 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 July 2021
Resolved
CE1- Vessels Log - The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies and be sure to log each event in the vessels log book. The vessels log book should also contain passenger counts IAW with the companies operating procedures.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 29 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2021
Resolved
CE2- Forward Lifering Bouy- Found cracking in outter shell, Lifering bouy shall be repaired or replaced to ensure bouyancy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2021
Resolved 29 July 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 July 2021
Resolved
CE3- First Aid Kit- The vessels first aid kid needed to be supplied with Aspirin
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 29 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 July 2021
Resolved
CE4- Exhaust Leak- The vessel appears to have a exhaust leak on the Main portside engine. The problem was identified upon the MI gas meter detecting a high level of carbon monoxide when entering the engine room space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2021
Resolved 29 July 2021
Resolution: Vessel mechanic determined that the exhaust was from normal operation of the crank case breather but that the mechanic did intend on replacing the gaskets.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 July 2021
Resolved
CE5- DAPI Audit- While on site for the annual inspection the crew was unable to provide proper documentation in regards to the DAPI program. The company shall provide a copy of the MSI report, as well as a copy of the companies consortium.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2021
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 23 September 2020
Resolved
Tighten/secure bolts on the port and starboard rudder actuator at the posts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2020
Resolved 22 October 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 September 2020
Resolved
Cover multiple exposed electrical connections in the engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2020
Resolved 22 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 September 2020
Resolved
Replace life ring light battery
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 20 October 2020
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 23 September 2020
Resolved
Tighten/secure port and starboard hydraulic tank covers in engine room
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 20 October 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 July 2019
Resolved
The space forward of the collision bulkhead need not be
fitted with a bilge suction line when the use of a
portable bilge pump is suitable for removing water from
the space. The portable pump on board is not currently
adequate to remove water from the forepeak. Provide
adequate pump within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 21 August 2019
Resolution: Vesse's crew purchased adequate pump as witnessed by attending marine inspector.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 July 2019
Resolved
Vessel is required to conduct drills on board and log
monthly. The operator failed to provide records.
Conduct drills and provide a record to marine inspector
within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 21 August 2019
Resolution: Vessel provided records to attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 July 2019
Resolved
All vessel's crew was not familiar with how to pump out
every space using the bilge system pump. Provide
training to all crew members and document. Provide this
documentation to marine inspector within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 21 August 2019
Resolution: Crew provided records of training to attending marine inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 25 June 2018
Resolved
Vessel must replace exhaust hose on port engine. Found hole in vessel's port engine wet exhaust hose rendering engine inoperable and compromising watertight integrity
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 27 June 2018
Resolution: Verified Exhaust hose on port engine was replaced
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 June 2018
Resolved
Vessel must replace battery on ring buoy light. Battery was found expired
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 19 July 2018
Resolution: Cleared to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 June 2018
Resolved
First-aid kit must have all of the items listed in 46CFR 160.041-4(b) *Found multiple expired items.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 19 July 2018
Resolution: Cleared to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2018
Resolved
33 Adult PFDs located next to head on starboard side must be marked "Adult"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 19 July 2018
Resolution: Cleared to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2018
Resolved
01 Child PFD must have retroflective material to meet the requirements in 46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 19 July 2018
Resolution: Cleared to the satisfaction of the attending marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 June 2018
Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Found 01 penetration in aft lazarette
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 19 July 2018
Resolution: Cleared to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 25 June 2018
Resolved
Vessel's Man Overboard instructions must remove sentence stating crew member will "standby to jump in water to rescue victim"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 19 July 2018
Resolution: Cleared to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 25 June 2018
Resolved
Vessel must have on-board instructions for the donning and use of life jackets aboard vessel. Vessel has on-board 02 types of life jackets with donning instructions for only 01 type
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2018
Resolved 25 June 2018
Resolution: Vessel corrected deficiency prior to departure of inspectors.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 June 2018
Resolved
Electrical wires under pilothouse require junction box
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 19 July 2018
Resolution: Cleared to the satisfaction of the attending marine inspector.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 25 June 2018
Resolved
Vessel must have Stability Letter on-board
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 19 July 2018
Resolution: Cleared to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2018
Resolved
Life jacket lockers must be marked with type and total number of life jackets
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2018
Resolved 25 June 2018
Resolution: Verified life jacket lockers were labeled properly
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2018
Resolved
Vessel is missing 02 life jackets as per the COI
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 25 June 2018
Resolution: Verified 02 life jackets were brought onboard to meet the required number on the COI
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 28 June 2017
Resolved
Identified ten (10) adult life jackets and two child in unserviceable condition, required the destruction and replacement.
Due 28 June 2017
Resolved 28 June 2017
Resolution: Jackets destroyed and replaced prior to MI's departure.
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 28 June 2017
Resolved
Port engine oil return line leaking, provided appropriate fabricated hose prior to commercial operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2017
Resolved 28 June 2017
Resolution: Hose replaced prior to MI'S departure.
Documentation › Logs/Records › Logbook (official)
Issued 28 June 2016
Resolved
To the satisfaction of the attending Marine Inspector, document crew training in vessel log book.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 19 July 2016
Resolution: Crew training properly logged.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 28 June 2016
Resolved
To the satisfaction of the attending Marine Inspector, properly secure the engine room bilge pump wiring overhead terminal block.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 19 July 2016
Resolution: Overhead wiring in Engine space properly secured.
Fire Fighting › Fire Hoses › Length
Issued 28 June 2016
Resolved
To the satisfaction of the attending Marine Inspector, provide sufficient length of fire hose to cover all areas of the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 28 June 2016
Resolution: Proper length of fire hose was provided.