MAURY USCG vessel records Sign in
← All vessels

FT. DEARBORN

FT. DEARBORN is a 1985 passenger vessel (inspected). The Coast Guard has recorded 124 inspections since 1985, most recently in August 2026, along with 109 deficiencies, 2 operational controls and 10 casualty investigations between 2006 and 2023.

Records from 1985 to 2026. Most recent: inspection, 10 August 2026.

Built
1985
Last inspected
10 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ8608
250257
Flag
UNITED STATES
367197480
Maury page id
psix-250257

Inspections, by type

…with no type recorded15
Years with a record 41 calendar years (1985–2026)
The 124 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 22.0 ft × 7.3 ft
Registered tonnagegross 72 / net 58
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORP · WARREN, RI, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 28 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Simplified, Net Ton
72 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ8608MMSI 367197480 · active · compulsorily equipped · granted 3 January 2018, expires 3 January 2028
WBK6393MMSI 367197480 · expired · compulsorily equipped · granted 19 June 2007, cancelled 4 November 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LITTLE LADY Passenger (Inspected) · MISLE 493321 · 9 June 2006 · activity 2708589

Inspection history · 124

10 August 2026 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8461064
24 April 2026 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8354219
26 March 2025 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8097205
24 January 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8069424
24 October 2024 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8038722
8 July 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7953350
26 June 2024 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7942746
16 November 2023 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7825827
26 September 2023 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7798984
26 September 2023 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7889829
23 August 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7775161
7 June 2023 Annual Inspection · MTSA Verification · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7706259
23 May 2023 In-Service Inspection · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7694587
10 November 2022 Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7594189
16 August 2022 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7535059
28 June 2022 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7489350
22 July 2021 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7268072
12 June 2021 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7227502
10 June 2021 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7221138
10 May 2021 DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7193813
7 April 2021 Examination of Repairs · Plan Review "T" Boat
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7170171
13 March 2020 Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6925985
12 March 2020 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6925558
12 November 2019 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6853919
25 April 2019 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6670616
1 April 2019 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6654140
28 March 2019 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6651573
6 December 2018 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6592730
31 October 2018 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6572348
31 July 2018 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6498044
31 July 2018 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6507368
18 June 2018 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6448560
30 May 2018 Administrative Inspection · Damage Survey
Physical examination · Navigation Center · Activity 6429464
8 March 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6368525
11 December 2017 Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6322345
8 May 2017 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6141284
24 April 2017 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6133830
8 September 2016 Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5998433
5 August 2016 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5982149
4 July 2016 Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5930807
3 July 2016 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5945758
23 May 2016 Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5994149
25 April 2016 MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5861743
4 November 2015 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5766915
21 August 2015 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5222590
18 August 2015 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5219989
17 August 2015 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5219729
28 October 2014 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5013557
22 May 2014 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4878060
21 May 2014 DAPI Audit · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4865531
3 March 2014 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4809349
25 June 2012 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4357086
19 June 2012 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4349130
18 June 2012 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4348828
2 June 2012 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4333349
23 May 2012 Annual Inspection · Deficiency Check · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4319954
16 December 2011 Plan Review (Other than "T")
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4209586
28 July 2011 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4096870
17 July 2011 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4085798
17 July 2011 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4155382
20 January 2011 Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3929814
26 October 2010 Plan Review "T" Boat · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3878199
16 March 2010 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3696828
3 July 2009 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3526536
2 April 2009 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3445081
1 April 2009 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3439355
9 September 2008 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3321075
23 April 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3190715
23 April 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3200250
7 April 2008 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3176023
3 April 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3176684
1 June 2007 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2997365
17 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2927821
2 April 2007 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2899965
31 March 2007 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2910051
9 June 2006 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2708589
7 June 2006 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2672867
10 November 2005 Hull Examination
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2532592
22 September 2005 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2498513
25 April 2005 COI Inspection · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2340819
2 September 2004 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2184270
26 August 2004 MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2181227
24 June 2004 Security Plan Review - VSP
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2092337
26 April 2004 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2050830
15 May 2003 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1792888
2 May 2002 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1607606
24 June 2001 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1067679
4 May 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1468647
9 June 2000 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 818911
15 May 2000 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1379079
5 April 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1048428
21 June 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1462763
11 May 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1419941
22 May 1997 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1442579
15 November 1996 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 867804
17 September 1996 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1134215
25 July 1996 Re-Inspection · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1398511
11 April 1996 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 883183
7 November 1995 Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 884171
5 September 1995 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 875884
13 June 1995 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1452062
16 June 1994 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1354769
18 October 1993 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 846823
9 June 1993 Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1154193
2 September 1992 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 940092
9 July 1991 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 942418
9 July 1991 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 942419
4 April 1991 Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1218845
18 July 1990 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 910408
18 January 1990 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 912245
19 July 1989 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1217630
8 March 1989 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 891537
14 September 1988 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1351480
22 July 1988 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1037235
13 January 1988 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1327472
6 May 1987 Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1335413
19 December 1986 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1027458
12 November 1986 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1327819
16 October 1986 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1010150
14 October 1986 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1011782
2 October 1986 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1316193
11 September 1986 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1004874
8 September 1986 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1025336
22 July 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 979990

Deficiency record · 109

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 April 2026 Resolved
An adult life jacket must be provided for each person onboard. During annual inspection, 12 adult life jackets were found to be in a non-serviceable condition. The vessel is authorized to only carry 227 passengers until corrected.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 14 May 2026
Resolution: Owner provided photo of new Adult PFD's properly labeled.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 24 April 2026 Resolved
For portable extinguishers, the inspections, maintenance procedures and hydro test are required by NFPA 10. The CO2 extinguisher onboard does not have the hose conductivity test done since 2024. Service IAW NFPA 10.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2026
Resolved 14 May 2026
Resolution: Hose had test completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 June 2024 Resolved
All equipment shall be of a type designed for the potential involved and so identified. Power panels in engine room and forward closet need to be labeled with voltage type.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 8 July 2024
Resolution: Received photographs from [name withheld] showing electrical panels with proper labeling.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 June 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First aid kit is not of approved type.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 8 July 2024
Resolution: Received photographs from [name withheld] showing new first aid kit onboard vessel.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 May 2023 Resolved
A visual and audible alarm must be provided at the operating station to indicate high water level in the bilge. The alarm panel incorporating the bilge high water alarms at the operating station is inoperable. Make repairs to the alarm panel and prove proper operation of the bilge high level alarms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 August 2023
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 23 May 2023 Resolved
The electrical outlet behind the main deck bar was installed with the polarity reveresed. Make repairs to the same.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 7 June 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 May 2021 Resolved
Official number is only stenciled. Mark official number in block Arabic letters not less than 3 inches in height proceeded NO. Official number mujst be permanently affixed so that alteration or removal would be obvious.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 10 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 April 2019 Resolved
IAW with CG-CVC Policy Letter 17-08, vital system prime movers whether required by regulation or not, should be tested when new machinery is installed or upgraded or at any time for cause (may include overhauling of engine or its components). Vessel failed to notify Coast Guard of major engine overhaul, and therefore testing of machinery alarms were not conducted. Must conduct machinery alarms to the satisfaction of the attending marine inspector. 46 CFR 115.700
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 May 2019
Resolution: Vessel proved low lube oil and high water temperature alarms operational for both port and starboard propulsion engines to the satisfaction of attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 April 2019 Resolved
Repairs or alterations the hull, machinery, or equipment that affects safety of vessel must not be made without approval from cognizant OCMI. Vessel installed new block heater system on vessel without approval. Must submit electrical online and bill of materials to Coast Guard for approval.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2019
Resolved 1 May 2019
Resolution: Vessel has removed all installed electrical cables from block heater units to distribution panel. Block heater units are still installed in engine blocks with their power cords coiled and secured with vessel danger tagout/lockout procedures. SAT with USCG
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 April 2019 Resolved
Stern void space is not watertight. Must ensure watertight integrity in space to satisfaction of attending Marine Inspector. (Fwd Stb Corner)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2019
Resolved 12 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 April 2019 Resolved
Bilge manifold must be labled.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2019
Resolved 1 May 2019
Resolution: Vessel has installed bilge diagram at local mainifold controll and has labeld mainifold valves to the satisfaction of attending Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 25 April 2019 Resolved
Must conduct fire and abandon ship drill prior to carrying passengers w/USCG.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2019
Resolution: Vessel conducted SAT fire and MOB drills while underway to the satisfaction of attending Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 25 April 2019 Resolved
Monthly fire drill not logged properly. Conduct fire drill and log IAW regulation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2019
Resolved 1 May 2019
Resolution: Vessel logged fire and MOB drills conducted 01MAY2019 and was observed with satisfaction by the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 April 2019 Resolved
Structural fire protection insulation falling in engine space overhead. Replace/repair to satisfaction of Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2019
Resolved 1 May 2019
Resolution: Vessel has repaired structural fire protection insulation that was falling from engine space overhead to the satisfaction of attending Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 28 March 2019 Resolved
Vessel reported loss of steering while fueling at dock. Vessel must verify proper operation of the steering gear prior to carrying passengers/operations and provide proper documentation attesting to the repairs and findings of service tech. 46 CFR 119.600
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2019
Resolved 1 April 2019
Resolution: Witnessed satisfactory operation of steering gear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 November 2018 Resolved
When clutching in STBD and bringing RPM's up, once settled out, MDE would lose approx 200-300 RPM's. Fix prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 November 2018
Resolved 13 November 2018
Resolution: See Tech report in Docs. Tested underway. All Sat
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 8 March 2018 Resolved
Provide testing procedures for generator and then test procedure in the presence of a marine inspector
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 March 2018
Resolved 22 March 2018
Resolution: conducted machinery test IAW written procedures
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 December 2017 Resolved
Install lagging on new generator installation.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 March 2019
Resolved 6 December 2018
Resolution: added insulation to exhaust
Lifesaving › Lifebuoys › Serviceable
Issued 25 April 2016 Resolved
Replace or repair 2 life ring buoys. 46 CFR 117.70(B)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 23 May 2016
Resolution: 2 new ring bouys have been installed on vessel
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 25 April 2016 Resolved
Replace 79 adult life jackets. Passenger count reduced to 160 until new jackets are replaced. 46 CFR 117.71(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Resolution: added 46 life jackets to vessel.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 25 April 2016 Resolved
Replace reflective tape on 19 adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Resolution: New Tape has been installed on Life Jackets
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 21 May 2014 Resolved
Re-new all weathered retro-reflective tape on life jackets.
Condition: Improper/Lack of Maintenance
Due 21 June 2014
Resolved 22 May 2014
Resolution: Re-placed worn tape on subject life jackets.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 21 May 2014 Resolved
Replace missing vapor barrier in engine room.
Condition: Improper/Lack of Maintenance
Due 21 June 2014
Resolved 28 October 2014
Resolution: New insulation has been installed with vapor barrier.
Fire Fighting › Fire Pumps › Arrangement
Issued 21 May 2014 Resolved
Prove proper operation of fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2014
Resolved 22 May 2014
Resolution: pump tested and working sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 June 2012 Resolved
Remove or install per the manufacturer’s instructions the rope lights that are on board the vessel.
Action required: 705 - Other - as specified
Due 19 July 2012
Resolved 25 June 2012
Resolution: Vessel removed spliced rope lighting, installed a GFCI receptacle and installed new, un-altered rope lighting which is powered via the newly installed GFCI as per the manufacturer''s instructions. All sat.
Electrical › Lighting (service) › Ground Indicator
Issued 19 June 2012 Resolved
Ensure the vessels tope lights are plugged into a ground fault circuit interrupter that is properly installed and functioning.
Action required: 705 - Other - as specified
Due 19 July 2012
Resolved 25 June 2012
Resolution: Vessel removed spliced rope lighting, installed a GFCI receptacle and installed new, un-altered rope lighting which is powered via the newly installed GFCI as per the manufacturer''s instructions. All sat.
Electrical › Electric Supply System (service) › Transformer
Issued 18 June 2012 Resolved
Provide isolation transformer or other acceptable means to prevent ship's hull from carrying current while on shore power. 46CFR183.10-30(a), 46CFR111.05.11, 111.05-13, 111.05-15, 111.05-17.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 April 2013
Resolved 12 February 2014
Resolution: Actual install of the isolation transformer and removal of ground-fault current on vessel hull was verified during previous inspection see MISLE activity 4557448.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (hydraulic)
Issued 2 June 2012 Resolved
Make permanent repairs to Port MDE and prove proper operation to attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2012
Resolved 3 June 2012
Electrical › Electric Supply System (service) › Cable
Issued 23 May 2012 Resolved
Replace yellow battery cable for genset or prove that it meets the standards required by 46CFR120.340(D).
Action required: 705 - Other - as specified
Due 23 June 2012
Resolved 18 June 2012
Resolution: Company replaced battery cable for genset with approved cable as required.
Electrical › Electrical Distribution System (service) › Neutral Bus
Issued 23 May 2012 Resolved
Identify any equipment grounding conductors that are directly connected to the neutral bus in the FWD distribution panel. Separate those equipment grounding conductors from the neutral bus. Install a ground bar in the distribution panel & connected all equipment grounding conductors to the ground bus.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 July 2012
Resolved 25 June 2012
Resolution: Company hired electrician to identify and separate equipment grounding conductors from the neutral bus in the FWD A/C power distribution panel. New ground bus was installed in panel to facilitate connection of equipment grounding conductors.
Electrical › Electrical Distribution System (service) › Neutral Bus
Issued 23 May 2012 Resolved
Disconnect each neutral conductor from the neutral bus in the FWD distribution panel; conduct continuity tests to the ships hull on each neutral conductor. Ensure that each neutral conductor has at least 1 megaohm of resistance to the ships hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 July 2012
Resolved 25 June 2012
Resolution: Company hired electrician to conduct continuity tests from each conductor terminated on the neutral bus in the fwd distribution panel to the ship''s hull. Witnessed readings and verified resistance from each conductor to ship''s hull was 1 mega Ohm or mor
Lifesaving › Launching Appliances › Davit
Issued 16 December 2011 Resolved
Davit was renewed and is utilized as part of the man overboard recovery system. Complete operational test during a man overboard drill to the satisfaction of the attending Marine inspector.
Due 27 May 2012
Resolved 23 May 2012
Resolution: Witnessed proper operation of the davit during a man overboard drill conducted with a rescue mannequin.
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 28 July 2011 Resolved
Replace generator fuel hoses and fuel hose fittings with proper tyuep IAW 46 CFR 56.60-25
Action required: 705 - Other - as specified
Due 28 July 2011
Resolved 28 July 2011
Resolution: All required hoses have been changed out and meet J1942
Engineering › Bilge Water Management System › Piping
Issued 16 March 2010 Resolved
Noted that bilge suction box was missing and replaced with mesh in forward compartment. Required O/O to replace with correct components to ensure proper dewatering of space IAW 46 CFR 182.25-5. Vessel is required to have bilge suction that is 3 x the nominal bilge pipe size.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2010
Resolved 13 April 2010
Resolution: Screen replaced sat.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 16 March 2010 Resolved
O/O was not prepared to conduct machinery shut-downs for lube oil low pressure. Required O/O to test machinery alarms IAW 46 CFR 115.804
Action required: 705 - Other - as specified
Due 19 April 2010
Resolved 13 April 2010
Resolution: Report rcvd of sat test.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 16 March 2010 Resolved
Required test of machinery alarms IAW 46 CFR 115.804
Action required: 705 - Other - as specified
Due 19 April 2010
Resolved 13 April 2010
Resolution: Report rcvd of sat test.
Navigation › Piloting/Steering › Marine Charts
Issued 1 April 2009 Resolved
Correct and update charts for navigation as listed in Notice to Mariners per 46 CFR 124.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 1 April 2009
Lifesaving › Inflatable Buoyant Apparatus › Approval
Issued 7 April 2008 Resolved
Obtain OCMI approval for modifications to lifesaving appliances. Vsl is limited to Rivers route until plans are approved, installation is complete and approved to the satisfaction of an attending Marine Inspector.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 23 April 2008
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 7 April 2008 Resolved
Properly leash all hatch covers on the main deck.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 23 April 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 April 2008 Resolved
Remove all dead-end wires in the stereo space.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 23 April 2008
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 7 April 2008 Resolved
Replace/remove all plastic trash cans with non-combustable ones.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 23 April 2008
Fire Fighting › Fire Pumps › Arrangement
Issued 7 April 2008 Resolved
Prove that the fire/bilge pump meets 46 CFR 120.320 or provide OCMI with plans to properly replace motor/pump with pump that operates in ambient temperature of 50 degrees Celcius.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 4 September 2008
Resolution: After discussing the current installation with MSC, it was determined that the motor was sufficient for service.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 April 2008 Resolved
Repair/replace port MDE alarm wires that melted and provide heat protection.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 23 April 2008
Electrical › Electric Supply System (service) › Battery Charger
Issued 7 April 2008 Resolved
Repair/replace battery charger cable that are worn/wasted.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 15 May 2008
Resolution: Examined the installation of new cables. All sat.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 7 April 2008 Resolved
Repair/repair stbd sanitary water pump check valve.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 23 April 2008
Personnel › Manning/Qualifications › First Aid Certified Personnel
Issued 7 April 2008 Resolved
Provide proof of at least 50% of the crew have first aid/cpr cards.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 23 April 2008
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 7 April 2008 Resolved
Provide proof of drug/alcohol program IAW 46 CFR Part 16.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 23 April 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 April 2008 Resolved
Provide electrical supports for wiring of new installations every 24" iaw 46 CFR 120.340.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 15 May 2008
Resolution: New teflon coated supports (black in color) were install throughout the vessel.
Fire Fighting › Fire Hoses › Location
Issued 25 April 2005 Resolved
Properly mark canopy or remove canopy located aft of the wheelhouse indicating fire station
Action required: 705 - Other - as specified
Due 25 May 2005
Resolved 25 May 2005
Resolution: Company removed canopy, all sat.
Lifesaving › Lifebuoys › Size
Issued 25 April 2005 Resolved
Provide ring buoys that are orange in color in accordance with 46 CFR 122.604(g)
Action required: 705 - Other - as specified
Due 25 June 2005
Resolved 16 September 2005
Lifesaving › Buoyant Apparatus › Serviceable
Issued 25 April 2005 Resolved
Make needed repairs to buoyant apparatus that have holes or cuts.
Action required: 705 - Other - as specified
Due 25 May 2005
Resolved 25 May 2005
Resolution: They used the [name withheld] repair kit for the buoyant apparatus, all sat.
Lifesaving › Lifefloat › Paddle
Issued 25 April 2005 Resolved
Provide paddles for the bouyant apperatus in accordance with 46 CFR 122.604 (g)
Action required: 705 - Other - as specified
Due 25 May 2005
Resolved 25 May 2005
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 25 April 2005 Resolved
Renew or replace the retro-reflective tape on the child size lifejackets 46 CFR 604(h)
Action required: 705 - Other - as specified
Due 25 May 2005
Resolved 25 May 2005
Resolution: Replaced on board seven child size lifejackets, all sat.
Electrical › Electric Generation Source (service) › Panelboard
Issued 25 April 2005 Resolved
Lable breaker boxes in engine room 46 CFR 120.220
Action required: 705 - Other - as specified
Due 25 May 2005
Resolved 25 May 2005
Electrical › Electric Generation Source (emergency) › Generator
Issued 25 April 2005 Resolved
Remove or renew generator emergency shutdown.
Action required: 705 - Other - as specified
Due 25 May 2005
Resolved 25 May 2005
Resolution: Blanked off junction box, all sat.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 April 2005 Resolved
Provide receptacle and remove extension cord, outlet multiplier located starboard side in the wheelhouse.
Action required: 705 - Other - as specified
Due 25 May 2005
Resolved 25 May 2005
Resolution: Mounted receptacle and removed extension cord, all sat.
Electrical › Electric Generation Source (service) › Panelboard
Issued 25 April 2005 Resolved
Provide non conductive mat at switchboard
Action required: 705 - Other - as specified
Due 25 May 2005
Resolved 25 May 2005
Lifesaving
Issued 2 May 2002 Resolved
ROUTE RESTRICTED TO WITHIN 3 MILES FROM SHORE UNTIL HYDROSTATIC RELEASE MECHANISM FOR 406 EPIRB IS REPLACED. LEGACY COMPONENT DESC: HYDROSTATIC RELEASE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2002
Resolved 14 June 2002
Resolution: HAMMER HYDROSTATIC RELEASE REPLACED.
Navigation
Issued 2 May 2002 Resolved
REPAIR EXTINGUISHED ANCHOR LIGHT LEGACY COMPONENT DESC: LIGHTS
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2002
Resolved 2 May 2002
Resolution: ANCHOR LIGHT FUNCTIONING PROPERLY.
Engineering
Issued 2 May 2002 Resolved
MAKE PROPER REPAIRS TO SEWAGE PIPE IN HOLDING TANK VOID SPACE. LEGACY COMPONENT DESC: PIPING
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2002
Resolved 2 May 2002
Resolution: DRAIN LINE FROM SINKS INTO SEWAGE TANK WAS REPAIRED AND FUNCTIONS PROPERLY.
Lifesaving
Issued 15 May 2000 Resolved
Properly mark engine room escape hatch on main deck, with "Emergency Exit, Keep Clear", in accordance with 46 CFR 116.500 and to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Navigation
Issued 15 May 2000 Resolved
Provide and install an appropriate anchor ligt for vessel, in accordance with navigation rules and to the satisfaction of the attending marine in- spector.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Lifesaving
Issued 21 June 1999 Resolved
PROVIDE BRIGHTLY COLORED WATERTIGHT CONTAINER FOR SIGNAL FLARES AND LABLE THE SAME WITH "DISTRESS SIGNALS", TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 1 July 1999
Resolved 29 June 1999
Lifesaving
Issued 21 June 1999 Resolved
PROPERLY MARK UPPER DECK WITH MAXIMUM NUMBER OF PERSONS ALLOWED IN ACCORD- ANCE WITH STABILITY LETTER TO THE SATISFACTION OF THE ATTENDING MARINE IN- SPECTOR.
Condition: Unknown
Due 1 July 1999
Resolved 29 June 1999
Lifesaving
Issued 21 June 1999 Resolved
PROVIDE AND POST EMERGENCY BROADCAST PLACARD FOR OPERATING STATION TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 1 July 1999
Resolved 29 June 1999
Fire Fighting
Issued 22 May 1997 Resolved
Replace broken fire pump pressure gauge.
Condition: Unknown
Due 22 May 1997
Resolved 22 May 1997
Navigation
Issued 22 May 1997 Resolved
Provide current Great Lakes Coast Pilot.
Condition: Unknown
Due 22 May 1997
Resolved 22 May 1997
Navigation
Issued 25 July 1996 Resolved
Provide current magnetic compass deviation card.
Condition: Unknown
Due 25 July 1996
Resolved 25 July 1996
Deck/Cargo
Issued 25 July 1996 Resolved
Splice new anchor line attachment to anchor.
Condition: Unknown
Due 31 August 1996
Resolved 21 August 1996
Lifesaving
Issued 25 July 1996 Resolved
Renew fans or install guards on exhaust fans located in both bathrooms and the bar storage area.
Condition: Unknown
Due 25 July 1996
Resolved 25 July 1996
Construction/Loadline
Issued 25 July 1996 Resolved
Label or post diagram at bilge manifold showing compartment each valve_x001C_ services.
Condition: Unknown
Due 31 August 1996
Resolved 21 August 1996
Documentation
Issued 11 April 1996 Resolved
Provide current and valid stability letter from USCG upon satisfactory review of weight change/stability calculations submitted as a result of repowering.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Documentation
Issued 11 April 1996 Resolved
Submit calculations reflecting weight changes as a result of repowering main engines. Calculations must be submitted to USCG National Maritime Center, Washington D.C. prior to carrying any passengers.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Unknown
Issued 7 November 1995 Resolved
REMOVE OIL FROM BILGE.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Construction/Loadline
Issued 7 November 1995 Resolved
PROVE PROPER OPERATION OF FROZEN SEACHEST VENT VALVE.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Electrical
Issued 13 June 1995 Resolved
Replace wire screw nuts with pressure type connections in the following locations: a. both main engines, b. rudder indicator/steering compartment and install missing screw nut for port engine oil pressure sending unit and replace generator electric box cover.
Condition: Unknown
Due 10 July 1995
Resolved 3 August 1995
Lifesaving
Issued 13 June 1995 Resolved
Replace worn retro-reflective material on 213 life preservers as indicated by Marine Inspector._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 July 1995
Resolved 3 August 1995
Lifesaving
Issued 13 June 1995 Resolved
Obtain and install required number of buoyant apparatus; until such time, vessel's route is restricted to 1 mile from shore.
Condition: Unknown
Due 10 July 1995
Resolved 3 August 1995
Navigation
Issued 13 June 1995 Resolved
Provide a current copy of magnetic compass deviation table.
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Lifesaving
Issued 18 October 1993 Resolved
Effect repairs to one buoyant apparatus.
Condition: Unknown
Due 18 October 1993
Resolved 18 October 1993
Construction/Loadline
Issued 9 June 1993 Resolved
Renew port aft deck in way of connection to transom, appr 1.5' from transomto fwd edge of insert, and appr 3.5' from port shell plt to inbd end of insert. Renew appr 4' of rub rail, and straighten transom.
Condition: Unknown
Due 24 June 1993
Resolved 24 June 1993
Lifesaving
Issued 2 September 1992 Resolved
PROVIDE 1 ADULT PFD.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Lifesaving
Issued 9 July 1991 Resolved
REPLACE RETROREFLECTIVE TAPE ON TOPS OF SEVENTY-ONE (71) ADULT PFD'S.
Condition: Unknown
Due 9 July 1991
Resolved 9 July 1991
Engineering
Issued 4 April 1991 Resolved
REPLACE INSULATION ON DIESEL GENERATOR AND BOTH MAIN ENGINES NO LATER THAN 15JUN91.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Engineering
Issued 18 July 1990 Resolved
INSULATE EXPOSED PORTIONS OF EXHAUST LINES ON DIESEL GENERATOR AND BOTH MAIN ENGINES NOT LATER THAN 31 JULY 1990.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Electrical
Issued 18 July 1990 Resolved
PROVIDE GROUND STRAP FROM GENERATOR FRAME TO VESSEL STRUCTURE NOT LATER THAN 31 JULY 1990.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Lifesaving
Issued 18 July 1990 Resolved
PROVIDE 19 ADDITIONAL ADULT PFD'S FOR A TOTAL OF 239 AND 1 ADDITIONAL CHILDPFD FOR A TOTAL OF 24 NOT LATER THAN 31 JULY 1990. THE VESSEL MAY NOT CARRY MORE THAN 212 TOTAL PERSONS UNTIL THIS REQUIREMENT IS COMPLETED AND THE AMENDED CERTIFICATE OF INSPECTION IS POSTED.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Fire Fighting
Issued 18 July 1990 Resolved
DEMONSTRATE OPERATION OF HAND FIRE AND BILGE PUMP NOT LATER THAN 25 JULY 90
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Documentation
Issued 18 January 1990 Resolved
CREDIT DRYDOCK DUE 18JUL91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Lifesaving
Issued 22 July 1988 Resolved
PROCURE AN ADDITIONAL 3 CHILD PFDS NO LATER THAN COMPLIANCE DATE. VESSEL SHALL NOT CARRY MORE THAN 19 CHILDREN UNTIL REQUIREMENT IS COMPLETE.
Condition: Unknown
Due 22 July 1988
Resolved 22 July 1988
Fire Fighting
Issued 2 October 1986 Resolved
SERVICE B-II FIRE EXTINGUISHER #2 IN BAR AREA PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Electrical
Issued 2 October 1986 Resolved
REMOVE TEMPORARY LIGHTING FROM ENGINE ROOM, PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Accommodation/Occupational Safety
Issued 11 September 1986 Resolved
INSTALL ONE ADDITIONAL RAIL ON THE UPPER DECK IN WAY OF THE FIXED SEATING 14" ABOVE THE EXISTING TOP RAIL.
Condition: Unknown
Due 11 September 1986
Resolved 11 September 1986
Documentation
Issued 11 September 1986 Resolved
SUBMIT PROPOSED FIXED SEATING PLANS FOR THE MAIN DECK AND 01 DECK.
Condition: Unknown
Due 11 September 1986
Resolved 11 September 1986
Accommodation/Occupational Safety
Issued 8 September 1986 Resolved
REMOVE BENCHES ALONG HAND RAIL ON UPPER DECK.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Documentation
Issued 8 September 1986 Resolved
SUBMIT FIXED SEATING PROPOSED PLANS FOR MAIN DECK AND 01 DECK FIXED SEATINGALONG THE RAIL WILL NOT BE ALLOWED ON 01 LEVEL.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Lifesaving
Issued 8 September 1986 Resolved
STENCIL VESSEL'S NAME ON LIFE RING PORT SIDE OF PILOT HOUSE.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Navigation
Issued 8 September 1986 Resolved
REMOVE EXTENSION CORD FROM STERN LIGHT AND WIRE LIGHT TO EXISTING CABLE.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Lifesaving
Issued 8 September 1986 Resolved
PROVIDE WATER LIGHTS FOR THE SIX BUOYANT APPARATUS.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Fire Fighting
Issued 8 September 1986 Resolved
COMPLETE INSULATION OF ENGINEROOM OVERHEAD FOR A-15 REQUIREMENT IN ACCORD- ANCE WITH APPROVED PLANS.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Lifesaving
Issued 8 September 1986 Resolved
PROVIDE A WEAK LINK AND 100' PAINTERS FOR EACH BUOYANT APPARATUS GROUPING.-
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Construction/Loadline
Issued 8 September 1986 Resolved
REMOVE ALL OIL FROM MACHINERY SPACE BILGE.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Lifesaving
Issued 8 September 1986 Resolved
PROVIDE LIFE JACKETS DONNING INSTRUCTIONS AND POST ON THE MAIN DECK AND 01 DECK.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Lifesaving
Issued 8 September 1986 Resolved
STENCIL VESSEL'S NAME ON CLASS C EPIRB.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Fire Fighting
Issued 8 September 1986 Resolved
HAVE ALL PORTABLE FIRE EXTINGUISHERS SERVICED.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Documentation
Issued 8 September 1986 Resolved
PROVIDE AND MAINTAIN ON BOARD THE VESSEL'S CERTIFICATE OF DOCUMENTATION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Documentation
Issued 8 September 1986 Resolved
PROVIDE AND POST COPY OF CERTIFICATE OF INSPECTION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Documentation
Issued 8 September 1986 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Electrical
Issued 22 July 1985 Resolved
PROPERLY INSTALL SHORE POWER RECEPTICLE.
Condition: Unknown
Due 22 July 1985
Resolved 22 July 1985

Casualty record · 10

9 June 2006Routine · role: Transiting Vicinity of Primary Subject · 4 injured · activity 2708589
31 March 2007Routine · role: Involved in a Marine Casualty · activity 2910051
1 June 2007Routine · role: Involved in a Marine Casualty · activity 2997365
16 June 2011Routine · role: Involved in a Marine Casualty · activity 4089244
24 June 2011Routine · role: Involved in a Marine Casualty · activity 4089262
17 July 2011Routine · role: Involved in a Marine Casualty · activity 4155382
3 July 2016Routine · role: Involved in a Marine Casualty · activity 5945758
5 August 2016Routine · role: Involved in a Marine Casualty · activity 5982149
31 July 2018Routine · role: Involved in a Marine Casualty · activity 6507368
26 September 2023Routine · role: Involved in a Marine Casualty · activity 7889829
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.