MAURY USCG vessel records Sign in
← All vessels

TANGO

TANGO is a 1985 passenger vessel (inspected). The Coast Guard has recorded 58 inspections since 1985, most recently in July 2026, along with 20 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 9 July 2026.

Built
1985
Last inspected
9 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTS2230
250258
Flag
UNITED STATES
—
Maury page id
psix-250258

Inspections, by type

…with no type recorded1
Years with a record 39 calendar years (1985–2026)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
3 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 58

9 July 2026 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8434968
14 April 2026 Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8349697
9 May 2025 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8087904
11 July 2024 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7873642
16 November 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7624451
13 July 2023 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7646028
10 May 2022 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7411251
9 February 2022 Plan Review "T" Boat · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7393277
5 November 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161160
9 August 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161422
14 May 2020 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6904053
5 November 2019 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6849576
9 July 2019 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6637805
14 June 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6375241
30 November 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6307561
16 May 2017 Examination of Repairs · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6105424
19 May 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5830718
29 February 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5823796
21 March 2014 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4820389
8 May 2012 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4246477
17 February 2012 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4246474
13 December 2011 Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4207100
1 February 2011 DAPI Audit · Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3937228
29 April 2009 Re-Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3416706
5 May 2008 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3184687
17 March 2008 Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3165895
9 April 2007 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2904323
25 May 2006 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2629411
24 March 2006 Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2609066
18 May 2005 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2345027
5 April 2004 Re-Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2035342
24 June 2003 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1824558
30 April 2002 Re-Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1607569
23 May 2001 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1065858
23 May 2000 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1420335
26 April 2000 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 817105
10 June 1999 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 807333
17 May 1999 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1132075
15 May 1998 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1124961
30 April 1998 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1124164
3 June 1997 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1120454
4 June 1996 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1164068
25 May 1995 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1183829
26 April 1995 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 890262
3 June 1994 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1466890
13 May 1993 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1354398
7 May 1992 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1258560
24 April 1992 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1267910
6 June 1991 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1239889
6 June 1991 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1239890
23 May 1990 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 918840
15 June 1989 Hull Examination · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1346798
9 June 1988 COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 887732
24 April 1987 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1317596
3 April 1987 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1021121
21 May 1986 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 994609
13 March 1986 Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 998081
24 June 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 984076

Deficiency record · 20

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 July 2026 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. The sound insulation was found to be melted where the engine coolant hose was touching; in addition, the insulation pin cap was found to be chafing the coolant hose creating wear on the hose. Modify the insulation to prevent it from touching the coolant hose and renew the hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2026
Resolved 20 July 2026
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 16 November 2023 Resolved
Vessel is experiencing wood rot under the after port quarter bench. Crop and renew rotten wood to good material and protect from further damage. Conduct repairs to the satisfaction of the attending USCG Marine Inspector. 46 CFR 176.600(d)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 January 2024
Resolution: Vessel made proper repairs to bench platform and internal wood supports. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 16 November 2023 Resolved
Vessel's two forward docking lights on the port and starboard side are experience dry rot in the sealant around the hull penetrations above the waterline. Renew caulking material and repair to the satisfaction of the attending USCG Marine Inspector. 46 CFR 176.610(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 January 2024
Resolution: Vessel had removed old sealant and resealed the penetrations. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 November 2021 Resolved
Re-caulk scarf in the skeg.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 March 2022
Resolution: See Activity Number 7393277
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 August 2021 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. High water alarm light does not work.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2021
Resolution: Witnessed operational high water alarm light.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 May 2020 Resolved
Fireboy inoperatable for test, replace in kind, prove proper operation.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 May 2020
Resolved 14 May 2020
Resolution: New FireBoy installed and tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 July 2019 Resolved
Vessel did not have chartlet onboard for area of operation. Provide chartlet within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2019
Resolved 11 July 2019
Resolution: Chartlet on vessel.
Engineering › Bilge Water Management System › Pump
Issued 16 May 2017 Resolved
Light for bilge pump and alarm is not functioning. Repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 25 May 2017
Documentation › Certificates/Documents › Stability Letter
Issued 8 May 2012 Resolved
Passenger capacity is reduced to 18 IAW new 185 AAWPP
Action required: 705 - Other - as specified
Due 8 May 2012
Resolved 13 January 2014
Resolution: Vessel in full compliance with new AAWPP of 185lbs. new Stability Ltr and amended COI issued.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 May 2012 Resolved
Prove proper operation of installed VHF radio.
Action required: 705 - Other - as specified
Due 22 May 2012
Resolved 15 May 2012
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 29 April 2009 Resolved
Prove proper operation of audible alarm for fire protection system (FireBoy).
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2009
Resolved 7 May 2009
Resolution: Demonstrated proper operation of alarm.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 April 2009 Resolved
Replace battery in light on ring life buoy.
Due 8 May 2009
Resolved 29 April 2009
Resolution: Owner/operator replaced battery.
Documentation › Markings/Placards › Garbage Placard
Issued 29 April 2009 Resolved
Post MARPOL V placard.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 7 May 2009
Resolution: Posted MARPOL V placard.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 17 April 2007 Resolved
Replace fuel tank bonding wire.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2007
Resolved 25 April 2007
Resolution: Fuel tank bonding wire replaced.
Communications › Radio Communications › VHF Radiotelephone
Issued 9 April 2007 Resolved
Repair/replace VHF radio external speaker.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2007
Resolved 25 April 2007
Resolution: Replaced VHF external speaker.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 April 2007 Resolved
Replace markings on child lifejacket locker.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2007
Resolved 25 April 2007
Resolution: Re-labeled child lifejacket markings.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 9 April 2007 Resolved
Weigh pre-engineered fixed gas fire extinguisher, IAW Sec SENE Prevention Policy 02/03.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2007
Resolved 25 April 2007
Resolution: Fixed gas extinguishers weighed and logged IAW policy note 02/03.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 5 April 2004 Resolved
Properly prove the testing and weighing of the fire extinguishers
Due 17 May 2004
Resolved 17 May 2004
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 5 April 2004 Resolved
Replace the reflective tape on the 08 life jackets. restricted to carrying 20 adults intil the life jackets are repaired.
Due 17 May 2004
Resolved 17 May 2004
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 30 April 2002 Resolved
Provide proof of testing/servicing of the fixed fire fighting system
Action required: 705 - Other - as specified
Resolved 7 August 2002
Resolution: Witnessed satisfactory testing of the system.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.