Records from 2007 to 2026. Most recent: inspection, 28 April 2026.
Inspection history · 18
28 April 2026
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8330312
23 March 2026
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8330508
15 April 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8111553
16 April 2024
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7895976
13 March 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7877944
11 April 2023
Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7666342
14 April 2022
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7428867
16 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7412710
22 March 2021
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7160591
22 July 2020
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7064428
18 March 2020
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6890533
15 January 2020
In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6890540
3 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6647500
24 April 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6384359
6 March 2018
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6363843
20 April 2017
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6129194
21 March 2016
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5837579
1 February 2016
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5807135
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 April 2025
Resolved
Obtain 48 doses non-expired aspirin
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2025
Resolved 17 April 2025
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 April 2025
Resolved
Repair bilge alarm in engine room
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2025
Resolved 17 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 April 2025
Resolved
Obtain 6 orange smoke or red hand flares
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2025
Resolved 17 April 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 April 2024
Resolved
Provide current COD.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 19 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2024
Resolved
Provide 1 additional adult lifejacket prior to carrying 32 adult passengers.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 April 2024
Resolved 19 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 April 2023
Resolved
Service portable and fixed fire extinguishers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2023
Resolved 14 April 2023
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 11 April 2023
Resolved
Renew EPIRB battery and hydrostatic release prior to operating beyond 3NM.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2023
Resolved 14 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2023
Resolved
Provide 01 additional PFD prior to carrying more than 31 adult passengers provide additional PFD. Vessel has only 31 Adult PFD's required 32. Condemned 3 on inspection.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 May 2023
Resolved 14 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 April 2023
Resolved
Provide 04 additional night flares prior to operating beyond LBS routes. Vessel only has 08 night flares.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 May 2023
Resolved 14 April 2023
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 April 2023
Resolved
Provide alcohol test strips.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2023
Resolved 14 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2023
Resolved
Add retro reflective tape to life ring.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2023
Resolved 14 April 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 April 2022
Resolved
Equipment is expired and need re-inspection by a certified servicing technician.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2022
Resolved 18 April 2022
Resolution: Received updated fire fighting certificates.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 April 2022
Resolved
Aspirin was expired in the First Aid Kit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2022
Resolved 18 April 2022
Resolution: Received proof of unexpired aspirins.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 April 2021
Resolved
A vessel’s first aid kit and it’s contents must be approved or meet an equivalent standard. Identified several expired first aid contents in the vessel’s first aid kit. O/O purchases new contents, however does not remove the old contents. Remove all expired contents in the vessel’s first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2021
Resolved 29 April 2021
Resolution: New approved FA kit purchased
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 April 2021
Resolved
A vessel on a limited coastwise route must carry six (6) red hand flares and six (6) orange smoke flares, or a substitution prescribed in 46 CFR 180.68 (c) is authorized. At the time of the inspection the vessel only had three (3) orange smoke flares and Four (4) red hand flares. Provide the appropriate number of flares for the route the vessel is certificated for.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2021
Resolved 29 April 2021
Resolution: Flares purchased and installed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 April 2021
Resolved
The equipment provided for each life float or buoyant apparatus must meet the following specifications. (f)(4) a floating electric water light must be approved under 46 CFR 161.010 (sub-chapter Q) UL/ANSI incorporated by reference. Identified the float light associated with the top life float as inoperable and out of service. The light referenced was most probably in excess of 10 years old given the design and construction of the float light (using d cell batteries) . Replace the floating electric light for the identified life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2021
Resolved 6 May 2021
Resolution: New float light provided and installed rcvd receipt and photo of installed via email
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 18 March 2020
Resolved
Install new hose clamps on R/W suction at ball valve for MDE driven washdown pump. Hose is inplace and is not clamped with mechanical hose clamp fastenings. Appeared to have been removed.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2020
Resolved 18 March 2020
Resolution: Installed new hose clamps
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 6 March 2018
Resolved
Replace overboard discharge valve for MSD system
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 3 April 2018
Resolution: O/O installed new overboard discharge valve for the sewage holding tank
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 6 March 2018
Resolved
Technician to attest to oil leak on MDE turbo by way of cool side
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 8 March 2018
Resolution: Spoke [name withheld] Tech., cleared outstanding def.
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 March 2018
Resolved
Replace cooling loop bracket for air receiver on MDE
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 3 April 2018
Resolution: O/O installed new bracket on the MDE
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 March 2016
Resolved
Install batetry post covers for both batteris in ENG Room compartment.
Due 15 April 2016
Resolved 22 April 2016
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 29 March 2016
Resolved
Provide proof of summitted MIS Report.
Due 29 March 2016
Resolved 22 April 2016
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 29 March 2016
Resolved
Pre-employment testing and background checks not completed. Provide pre-employment and background checks for each memember.
Due 29 March 2016
Resolved 22 April 2016
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 29 March 2016
Resolved
Supervisor to take 1 hour EAP training and provide proof of completion.
Due 29 March 2016
Resolved 22 April 2016
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 29 March 2016
Resolved
Provide list of covered members.
Due 29 March 2016
Resolved 22 April 2016
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 29 March 2016
Resolved
Provide SAP name and contact information.
Due 29 March 2016
Resolved 22 April 2016
Communications › Radio Communications › EPIRB
Issued 29 March 2016
Resolved
EPIRB Hydrostatic release expired. Provide valid hydrostaic release.
Due 29 March 2016
Resolved 29 March 2016
Resolution: Corrected on the spot.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 2 February 2016
Resolved
Make repairs to cracked weld on strut around shaft.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 February 2016
Resolved 18 March 2016
Resolution: Strut around the shaft was welded and structurally sound.
Construction/Loadline › Structures › Deck Plating
Issued 2 February 2016
Resolved
Make repairs to FRP decking on port side, just aft of main cabin (from the bulwark to the deck)
Action required: 705 - Other - as specified
Due 2 February 2016
Resolved 18 March 2016
Resolution: Old FRP was removed and replaced with new layers of FRP.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 February 2016
Resolved
Make repairs to pipe holding electrical wiring within stbd midship inspection hatch.
Action required: 705 - Other - as specified
Due 2 February 2016
Resolved 18 March 2016
Resolution: Pipe was reinforced in area of previous failure.