MAURY USCG vessel records Sign in
← All vessels

KINGFISH

KINGFISH is a 1985 commercial fishing vessel. The Coast Guard has recorded 48 inspections since 1985, most recently in October 2022, along with 47 deficiencies.

Records from 1985 to 2022. Most recent: inspection, 3 October 2022.

Built
1985
Last inspected
3 October 2022
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD2332
250494
Flag
UNITED STATES
368058810
Maury page id
psix-250494

Inspections, by type

…with no type recorded4
Years with a record 27 calendar years (1985–2022)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)43.0 ft × 14.0 ft × 8.0 ft
Registered tonnagegross 33 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMODUTECH MARINE INC · TACOMA, WA, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLAKEBAY, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 26 June 2026 · expires 31 July 2027
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Simplified, Gross Ton
26 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK4801MMSI 368058810 · active · voluntarily equipped · granted 15 September 2018, expires 15 September 2028
WDD2332MMSI 367113910 · expired · compulsorily equipped · granted 12 May 2006, cancelled 16 July 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 48

3 October 2022 Type not recorded
No type recorded · Maritime Force Protection Unit Bangor · Activity 7571657
14 January 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5797102
5 December 2011 COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4190865
23 September 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3326323
23 October 2007 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3084875
4 October 2007 Examination of Repairs · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3068299
27 April 2007 Simplified Stability Test
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2915654
10 April 2007 Plan Review "T" Boat
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2905110
31 July 2006 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2678660
18 May 2006 COI Inspection · Simplified Stability Test
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2636191
17 April 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2626539
23 February 2006 Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2603906
15 September 2005 Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2464261
2 May 2005 Annual Inspection · Drydock Extension
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2353187
25 June 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2110694
20 May 2004 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2064782
23 May 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1779829
23 May 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1620135
17 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1073802
14 May 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1387102
26 April 2001 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1063261
20 June 2000 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1053326
23 May 2000 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1403220
3 May 2000 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1376159
3 May 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1388799
24 February 1999 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 810979
27 July 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 795375
21 May 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1126975
6 May 1997 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1108250
4 September 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1257610
17 July 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1088374
1 May 1995 Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1339040
3 May 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 859864
28 September 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1154455
20 August 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 845561
27 May 1993 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 840489
13 May 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 944749
29 July 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1001239
16 July 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 678072
19 June 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 917672
14 May 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1237314
25 May 1990 Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1228510
9 May 1989 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 969610
17 May 1988 COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1351589
29 June 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1015338
6 May 1987 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1330478
25 April 1986 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1308776
16 May 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1291795

Deficiency record · 47

Engineering › Bilge Water Management System › Pump
Issued 23 September 2008 Resolved
Provide adequate portable bilge pump, prior to the carriage of passengers.
Due 23 October 2008
Resolved 14 October 2008
Resolution: Renewed.
Engineering › Fuel Oil Service System › Valve
Issued 23 September 2008 Resolved
Prove operation of fuel oil remote cutout valves, prior to the carriage of passengers.
Due 23 October 2008
Resolved 14 October 2008
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 18 May 2006 Resolved
Install and prove operation of Single Side Band. Vessel is restricted to operation within 20 miles of shore.
Due 18 July 2006
Resolved 31 July 2006
Documentation › Certificates/Documents › FCC SSL
Issued 18 May 2006 Resolved
Provide copy of radio station license to a Coast Guard Marine Inspector.
Due 18 June 2006
Resolved 15 June 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 May 2006 Resolved
Provide/install visual indicator for automatic operation of bilge pump in the engine room. 46 CFR 182.530(c)
Due 18 June 2006
Resolved 15 June 2006
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 18 May 2006 Resolved
Prove proper operation of vessel controls from the upper deck operating station to include engine gauges and steering. Vessel operators are restricted from operating the vessel from this operating station until this requirement is cleared by a Coast Guard Marine Inspector.
Due 18 June 2006
Resolved 15 June 2006
Stability › Weathertight Integrity › General
Issued 23 February 2006 Resolved
Make engineroom hatches watertight, and add securing devices, hinges or captive chains to hatches. Reference 46 CFR 179.360. Digital pictures maybe submitted to [email withheld] to clear this requirement.
Action required: 705 - Other - as specified
Due 23 May 2006
Resolved 18 May 2006
Resolution: Witnessed satisfactory water test of the engineroom hatches. Hatches are secured by metal latches and sealed so as to form a soft patch.
Engineering › Bilge Water Management System › Not Installed
Issued 2 May 2005 Resolved
Install positive shut off valves to electric bilge overboard (03 ea) IAW 46CFR182.520(e)(7).
Due 2 July 2005
Resolved 15 September 2005
Resolution: 1-inch brass spring loaded check valves installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 May 2005 Resolved
Prove proper operation of anchor light.
Action required: 705 - Other - as specified
Resolved 2 May 2005
Fire Fighting › Fire Bucket › Quantity
Issued 2 May 2005 Resolved
Supply and properly label one more fire bucket to make a total of 3 IAW 46CFR 181.610
Action required: 705 - Other - as specified
Resolved 2 May 2005
Personnel › Manning/Qualifications
Issued 20 May 2004 Resolved
Provide copy of senior deck hand letter.
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 25 May 2004
Lifesaving › Lifebuoys
Issued 20 May 2004 Resolved
Replace battery in life buoy light. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 20 May 2004
Lifesaving › Buoyant Apparatus
Issued 20 May 2004 Resolved
Replace batterys in life float lights.
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 20 May 2004
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 20 May 2004 Resolved
Provide double hose clamps on raw water intake on starboard main engine.
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 20 May 2004
Engineering › Fuel Oil Service System › Valve
Issued 20 May 2004 Resolved
Mark emergency fuel shut off valves.
Action required: 705 - Other - as specified
Due 20 June 2004
Resolved 25 June 2004
Resolution: Coorected via email.
Electrical › Electric Supply System (service) › Cable
Issued 20 May 2004 Resolved
Replace all wire nuts in engine room space or place connections in an enclosure.
Action required: 705 - Other - as specified
Due 20 June 2004
Resolved 25 June 2004
Resolution: Corrected via email.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 20 May 2004 Resolved
Replace weak link on life float with CG approved type.
Action required: 705 - Other - as specified
Due 20 June 2004
Resolved 25 June 2004
Resolution: Corrected via email
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 May 2004 Resolved
Replace expired or missing items in first aid kit.
Action required: 705 - Other - as specified
Due 20 June 2004
Resolved 25 June 2004
Resolution: Corrected via email
Engineering › Bilge Water Management System › Pump
Issued 20 May 2004 Resolved
Reconnect forward bilge pump.
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 20 May 2004
Stability › Watertight Integrity
Issued 23 May 2003 Resolved
Renew deck pump suction hose with suitable hose and double hose clamp. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 23 May 2003
Electrical › Electrical Distribution System (service) › Cable
Issued 23 May 2003 Resolved
Provide proper wire connectors to replace non-authorized wire nut connectors as indicated by the attending marine inspector.
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 24 May 2003
Lifesaving › Lifebuoys
Issued 23 May 2003 Resolved
Install onto life ring appropriate amount of retro-reflective tape. LEGACY COMPONENT DESC: retro-reflective tape
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 May 2004
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 3 June 2002 Resolved
Provide servicing and documention for fixed firefighting system in engine room, IAW 46 CFR 176.810(b)(2).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 3 June 2002 Resolved
Replace flame screen on fuel tank vent, stbd side. LEGACY COMPONENT DESC: Vent Pipe
Due 3 July 2002
Resolved 3 June 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 3 June 2002 Resolved
Complete hydrostatic testing of portable fire extinguishers IAW 46 CFR 176.810(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2002
Accommodation/Occupational Safety
Issued 14 May 2001 Resolved
REPLACE DAMAGED SEWAGE VENT LINE.
Condition: Unknown
Due 14 June 2001
Resolved 3 June 2002
Construction/Loadline
Issued 14 May 2001 Resolved
PROVIDE BILGE HIGH LEVEL INDICATOR IN THE STEERING COMPARTMENT (LAZARRETTE)IN ACCORDANCE WITH 46 CFR 182.530. PROVIDE VISUAL INDICATORS FOR EACH HIGHLEVEL ALARM AT THE OPERATING STATION.
Condition: Unknown
Due 14 June 2001
Resolved 3 June 2002
Lifesaving
Issued 14 May 2001 Resolved
PROVIDE TWO ADDITIONAL ADULT PFD'S. UNTIL THIS REQUIREMENT IS COMPLETED, THE VESSEL IS LIMITED TO 40 TOTAL PERSONS._x001C_ Q
Condition: Unknown
Due 14 June 2001
Resolved 3 June 2002
Fire Fighting
Issued 14 May 2001 Resolved
PROVIDE PROOF OF ANNUAL SERVICE FOR FIXED FIREFIGHTING.
Condition: Unknown
Due 14 June 2001
Resolved 3 June 2002
Navigation
Issued 14 May 2001 Resolved
PROVIDE A NAVIGATIONAL CHART OF LAKE TAHOE.
Condition: Unknown
Due 14 June 2001
Resolved 3 June 2002
Documentation
Issued 3 May 2000 Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Navigation
Issued 3 May 2000 Resolved
PROVIDE EMERGENCY BROADCAST PLACARD I.A.W. 46 CFR 184.506.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Construction/Loadline
Issued 21 May 1998 Resolved
MAKE ENGINE ROOM ACCESS COVERS WATERTIGHT (BOTH PORT & STBD).
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Fire Fighting
Issued 17 July 1996 Resolved
Provide servicing report for portable fire extinguishers.
Condition: Unknown
Due 17 July 1996
Resolved 17 July 1996
Lifesaving
Issued 17 July 1996 Resolved
Repair rips in lifefloat.
Condition: Unknown
Due 17 July 1996
Resolved 17 July 1996
Lifesaving
Issued 17 July 1996 Resolved
Provide lifejacket donning placard.
Condition: Unknown
Due 17 July 1996
Resolved 17 July 1996
Lifesaving
Issued 27 May 1993 Resolved
PROVIDE 6 RED FLARES BY 30SEP93. ITEM IS A NO SAIL PAST THIS DATE.
Condition: Unknown
Due 27 May 1993
Resolved 27 May 1993
Lifesaving
Issued 27 May 1993 Resolved
PROVIDE 6 ORANGE FLARES BY 31AUG93. ITEM IS A NO SAIL AFTER THIS DATE.
Condition: Unknown
Due 27 May 1993
Resolved 27 May 1993
Construction/Loadline
Issued 27 May 1993 Resolved
COMPLETE REPAIRS TO FOREPEAK HATCHES. VSL IS RESTRICTED TO A TOTAL OF 29 PERSONS ONBOARD AND NO PASSENGER FORWARD OF THE HOUSE UNTIL REPAIRS COMPLETED.
Condition: Unknown
Due 11 June 1993
Resolved 17 June 1993
Engineering
Issued 14 May 1991 Resolved
REPLACE CRACKED RAW WATER HOSE TO PORT ENGINE EXHAUST_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 May 1991
Resolved 14 May 1991
Construction/Loadline
Issued 14 May 1991 Resolved
CROP OUT AND RENEW ROTTED DECK AREA ABOVE FOREWARD COMPARTMENT. UNTIL REPAIR IS COMPLETED PASSENGERS SHALL BE RESTRICTED FROM THE BOW AREA AND THE VSL IS TO BE LIMITED TO CARRYING 30 PASSENGERS._x001C_ _x001C_
Condition: Unknown
Due 14 May 1991
Resolved 14 May 1991
Lifesaving
Issued 25 May 1990 Resolved
PROVIDE SIX RED HAND FLARES.
Condition: Unknown
Due 25 May 1990
Resolved 25 May 1990
Lifesaving
Issued 25 May 1990 Resolved
PROVIDE AN EMERGENCY CHECK OFF LIST AND POST IN FRAME ALREADY ON BOARD. (NOTE: CHECKOFF LIST HAD BEEN POSTED, BUT WAS MISPLACED DURING RECENT MAINTENANCE.)
Condition: Unknown
Due 25 May 1990
Resolved 25 May 1990
Construction/Loadline
Issued 6 May 1987 Resolved
INSTALL KEEPER CHAINS ON ALL HATCHES.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Documentation
Issued 6 May 1987 Resolved
PROVIDE AND POST AN EMERGENCY CHECK-OFF LIST.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Lifesaving
Issued 6 May 1987 Resolved
INSTALL THE APPROPRIATE C.G. APPROVED WEAK LINK FOR THE LIFEFLOAT.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Documentation
Issued 6 May 1987 Resolved
PROVIDE AND POST A CURRENT RADIO STATION LICENSE.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.