MAURY USCG vessel records Sign in
← All vessels

OCEAN ENCOUNTERS 2

OCEAN ENCOUNTERS 2 is a 1985 passenger vessel (inspected). The Coast Guard has recorded 84 inspections since 1985, most recently in September 2025, along with 112 deficiencies and 1 casualty investigation in 2011.

Records from 1985 to 2025. Most recent: inspection, 2 September 2025.

Built
1985
Last inspected
2 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ9561
250496
Flag
UNITED STATES
368027250
Maury page id
psix-250496

Inspections, by type

…with no type recorded16
Years with a record 38 calendar years (1985–2025)
The 84 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)31.6 ft × 12.0 ft × 5.6 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderD.R. RADON BOATBLDG INC · SANTA BARBARA, CA, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKONA, HI
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 16 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ9561MMSI 368027250 · active · compulsorily equipped · granted 14 March 2018, expires 14 March 2028 · licensed under a name not among this hull’s recorded names (not shown)
WDE9584MMSI 367418930 · expired · compulsorily equipped · granted 17 July 2009, cancelled 21 September 2019 · licensed under a name not among this hull’s recorded names (not shown)
WCZ2695MMSI not assigned · expired · compulsorily equipped · granted 17 May 1999, cancelled 18 July 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 84

2 September 2025 Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8226578
26 September 2024 Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8012221
14 May 2024 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7912540
20 June 2023 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7716796
8 November 2022 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7591373
2 June 2022 Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7466416
22 June 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7222731
20 January 2021 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7129650
3 June 2020 Annual Inspection · Internal Structural Exam · Drydock Exam · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6966604
29 May 2020 Drydock Extension · Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6963872
3 October 2019 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6827577
15 March 2018 COI Inspection · DAPI Audit · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6485532
6 September 2016 Annual Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6012906
6 September 2015 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5794184
28 October 2014 Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5021348
29 August 2014 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5008995
18 July 2011 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4080520
22 January 2011 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3932911
25 October 2010 Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3872299
9 September 2010 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3838934
16 July 2009 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3536564
29 October 2008 Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3353846
2 June 2008 Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3225466
2 July 2007 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2981004
18 September 2006 Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2869957
13 June 2005 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2546322
28 March 2005 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2321390
26 October 2004 Deficiency Check · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2228981
14 October 2004 Type not recorded
No type recorded · USCG Oceania District (dre) · USCG Oceania District (CGD-O) · Activity 2221106
23 July 2004 Deficiency Check · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2143114
14 July 2004 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2133376
27 April 2004 Type not recorded
No type recorded · USCGC KISKA (WPB 1336) · USCG Oceania District (CGD-O) · Activity 2109462
27 April 2004 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2237776
18 February 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2008760
11 February 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2005039
15 December 2003 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1964666
10 December 2003 Annual Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1950855
1 October 2003 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2004667
29 November 2002 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1717088
27 June 2002 Deficiency Check · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1490451
18 May 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1370224
20 April 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1063039
24 May 2000 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1420364
14 May 1999 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378729
9 March 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1384060
14 October 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 210722
14 October 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 767762
5 June 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 774641
26 March 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1091550
3 July 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355885
6 June 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374645
17 May 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1380517
15 May 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 31292
6 March 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1077586
3 January 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371257
7 December 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367596
4 November 1995 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353817
24 August 1995 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1189429
11 August 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 879859
13 July 1995 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 871795
5 May 1995 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1419436
26 May 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1456173
3 May 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367045
4 November 1993 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1396008
8 June 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 831732
5 May 1993 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 840902
10 February 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1139452
8 May 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 943317
7 January 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1259835
8 November 1991 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 940257
26 May 1991 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353200
9 May 1991 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1248311
14 May 1990 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 933396
12 May 1989 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1275206
24 May 1988 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1201334
24 May 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1205560
10 May 1988 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1201333
15 May 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1023788
23 December 1986 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1339121
5 November 1986 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1325937
25 June 1986 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1304991
20 May 1986 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 999438
10 June 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 979498
20 May 1985 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 982636

Deficiency record · 112

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: protect crew, other persons and the vessel from electrical hazards. Need to cap or remove dead end wires located next to Racor Filter in engine space to satisfaction of USCG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 4 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 September 2025 Resolved
Vessel EPIRBS must be tested monthly and logged. EPIRB only test once every three (03) months according to vessel log book. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 2 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 September 2025 Resolved
Vessels on limited coastwise routes are required to carry six (06) red and six (06) orange flares or twelve (12) red flares. Vessel had six (06) flares at the time of the inspection. Must add six (06) more flares for vessel's route. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 2 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 September 2024 Resolved
At each subsequent inspection for certification, the operator shall be prepared to have ready for inspection of the lifesaving equipment. Life float outer shell needs repair to prevent water intrusion and permanent damage, life float line to weak link needs to be stowed properly to ensure quick deployment and retro reflective tape needs to be changed out to satisfaction of USCG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 21 October 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2024 Resolved
Electrical equipment must be installed and maintained to prevent electrical ignition of flammable vapors and minimize accidental personnel contact with energized parts. Must cap all dead end wiring in engine space and electrical panel in forward salon space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 2 October 2024
Resolution: Operator sent pics to CG via email.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 26 September 2024 Resolved
At each subsequent inspection for certification, the operator shall be prepared to have ready for inspection of all machinery. Discovered minor diesel leak on main engine. Must troubleshoot and make repairs to satisfaction of USCG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 22 October 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 September 2024 Resolved
Operators must show evidence of proper maintenance of all fire extinguishing equipment. One (01) portable extinguisher at secondary helm has lapsed on annual servicing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 7 October 2024
Resolution: Verified o/s
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 20 June 2023 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. 10ft by 10ft heavy duty seat was not mounted to the deck and was loosely placed. Vessel rep must install correctly and secure the seat to the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2023
Resolved 27 June 2023
Resolution: Secured to the deck.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 June 2023 Resolved
Each paddle required for life floats must be at least four feet in length, lashed to the life float to which it belongs and buoyant. Life float paddles are not lashed to the life floats. Properly arrange the paddles to life float onboard vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 27 June 2023
Resolution: Paddles properly lashed to life float.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 June 2023 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. The steering wheel was falling off of the operating station, must ensure strength and reinforce the installation properly.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2023
Resolved 27 June 2023
Resolution: New installation of steering wheel and reinforced structure satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 20 June 2023 Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use, compass must be illuminated or restricted to daytime operation. Provide light for the compass.
Action required: 705 - Other - as specified
Due 20 June 2023
Resolved 27 June 2023
Resolution: Verified compass illumination.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 June 2023 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Life ring is unserviceable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2023
Resolved 27 June 2023
Resolution: New life ring onboard.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 June 2023 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. The high water alarm was not audible from the main operating station, requires hardwire installation to the upper deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2023
Resolved 27 June 2023
Resolution: New wiring installed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 June 2023 Resolved
The owner or managing operator or a qualified servicing facility shall conduct inspections and tests as applicable for fixed gas fire extinguishing systems and must provide evidence of the required servicing to the marine inspector The fire boy was not serviced. Vessel rep must arrange to have the fire boy inspected by servicing facility.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2023
Resolved 27 June 2023
Resolution: Verfied proper servicing of the fire boy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 October 2019 Resolved
Vessel shall have a lifejacket for every passenger. Replace 18 adult lifejackets. Passenger count reduced to 4.
Action required: 705 - Other - as specified
Due 3 December 2019
Resolved 4 October 2019
Resolution: Replaced 18 adult lifejackets.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 October 2019 Resolved
Replace expired items in first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 11 October 2019
Resolution: Replaced expired items in first aid kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2019 Resolved
Replace battery connections with a permanent type connectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 4 October 2019
Resolution: Replaced battery connections with a permanent type connectors
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 6 September 2016 Resolved
Vessel is to have its portable and semi portable gas fire extinguishing systems properly serviced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2018
Resolution: Marine Inspector verified portable and semi portable gas fire extinguishers were serviced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 6 September 2016 Resolved
Vessel needs to conduct satisfactory operational test of the vessel's pre-engineered fire system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2018
Resolution: Marine Inspector verified satisfactory operational test of the vessel's pre-engineered fire system.
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 September 2016 Resolved
Vessel needs to have all raw water supply and discharge hoses, and all other flexible hoses attached to vital systems properly secured with corrosion resistant metal hose clamps.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2018
Resolution: Marine Inspector verified all raw water supply and discharge hoses, and all other flexible hoses attached to vital systems were properly secured with corrosion resistant metal hose clamps.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 6 September 2016 Resolved
All bilges are to be free of standing oil.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2018
Resolution: Marine Inspector verified all bilges were free of standing oil.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 September 2016 Resolved
Vessel needs to conduct satisfactory sea trials and perform the required drills.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2018
Resolution: Marine Inspector viewed satisfactory sea trials and performed the required drills.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 6 September 2016 Resolved
Vessel needs to have the required amount of in-service distress flares onboard.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2018
Resolution: Marine Inspector verified the required amount of in-service distress flares onboard vessel.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 September 2016 Resolved
Vessel needs to be equipped with an opertional "Class D" or better vhf-dsc radio that is capable of integral gps capabilities or is connected to an electronic position device.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2016
Resolved 23 July 2018
Resolution: Marine Inspector verified required operational "Class D" or better vhf-dsc radio is connected to an electornic position device.
Communications › Radio Communications › EPIRB
Issued 6 September 2016 Resolved
Provide proof of valid EPIRB registration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2016
Resolved 23 July 2018
Resolution: Marine Inspector verified valid EPIRB registration.
Navigation › Piloting/Steering › Marine Charts
Issued 6 September 2016 Resolved
Vessel needs to have all required charts and publications onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 October 2016
Resolved 23 July 2018
Resolution: Marine Inspector verified all required charts and publications are onboard the vessel.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 September 2016 Resolved
Vessel operator needs to provide proof of holding a valid FCC marine radio operator permit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 October 2016
Resolved 23 July 2018
Resolution: Marine Inspector verified valid FCC marine radio operator permit.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 September 2016 Resolved
Vessel needs to have all required medicines on board and within expiration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 23 July 2018
Resolution: Marine Inspector verified all required medicines onboard and all within exiration dates.
Documentation › Markings/Placards › Lifejacket Placard
Issued 6 September 2016 Resolved
Vessel is to post all required placards for passengers to view.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 October 2016
Resolved 23 July 2018
Resolution: Marine Inspector verified all required placards are in plain view for passengers.
Communications › Radio Communications › EPIRB
Issued 18 July 2011 Resolved
Renew expired NOAA EPIRB registration.
Due 25 July 2011
Resolved 12 August 2011
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 July 2011 Resolved
Provide floating waterlight and attach to ring buoy. Vessel is restricted to daylight operations until cleared.
Due 25 July 2011
Resolved 12 August 2011
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 July 2011 Resolved
Renew 1 adult lifejacket. Vessel is restricted to the carriage of 25 persons until cleared.
Due 25 July 2011
Resolved 12 August 2011
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 July 2011 Resolved
Prove operation of forward bilge hi-water alarm.
Due 25 July 2011
Resolved 18 July 2011
Documentation › Markings/Placards › Lifejacket Placard
Issued 16 July 2009 Resolved
Post accurate PFD donning placard. Incorrect placard was posted for Type of Adult PFD's on board.
Due 30 July 2009
Resolved 13 August 2009
Navigation › Piloting/Steering › Marine Charts
Issued 16 July 2009 Resolved
Provide current copies of tide/current tables, coast pilot, light list paper marine charts and navigation rules.
Due 30 July 2009
Resolved 13 August 2009
Engineering › Bilge Water Management System › Interface Detector
Issued 16 July 2009 Resolved
Prove operation of high level bilge VISUAL alarm in forward space.
Due 30 July 2009
Resolved 13 August 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 July 2009 Resolved
Stock first aid kit IAW 46 CFR 184.710. Kit was missing several items.
Due 30 July 2009
Resolved 13 August 2009
Documentation › Certificates/Documents › FCC SSL
Issued 16 July 2009 Resolved
Provide and post copy of valid FCC Station License.
Due 30 July 2009
Resolved 13 August 2009
Communications › Radio Communications › EPIRB
Issued 13 June 2005 Resolved
Prove logs kept for EPIRB testing.
Due 13 July 2005
Resolved 21 July 2005
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 13 June 2005 Resolved
Provide copy of submitted MIS report.
Due 13 July 2005
Resolved 21 July 2005
Documentation › Certificates/Documents › FCC SSL
Issued 13 June 2005 Resolved
Provide valid Safety Radiotelephony Certificate.
Due 13 July 2005
Resolved 21 July 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 June 2005 Resolved
Obtain new tourniquet, burn cream, ammonia inhalants, and eye patch for first aid kit.
Due 13 July 2005
Resolved 21 July 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 June 2005 Resolved
Install temporary railings to bow.
Due 13 July 2005
Resolved 21 July 2005
Documentation › Markings/Placards › Capacity Marking
Issued 13 June 2005 Resolved
Mark upper deck for no passengers.
Due 13 July 2005
Resolved 21 July 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 July 2004 Resolved
Provide a CG light list.
Due 30 July 2004
Resolved 27 July 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 23 July 2004 Resolved
Provide servicing report for operating station B-1.
Due 30 July 2004
Resolved 27 July 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 July 2004 Resolved
Provide unexpired Aspirin and eye wash for the first aid kit.
Due 30 July 2004
Resolved 27 July 2004
Documentation › Logs/Records
Issued 18 November 2003 Resolved
Provide documentation that the company and all employees are participating in the drug and alcohol program. LEGACY COMPONENT DESC: Drug Test Records
Action required: 705 - Other - as specified
Due 18 December 2003
Resolved 10 December 2003
Stability › Water on Deck
Issued 18 November 2003 Resolved
Repair the aft freeing ports to prevent water from freely flowing onto the aft deck.
Action required: 705 - Other - as specified
Due 9 February 2004
Resolved 12 March 2004
Accommodation/Occupational Safety › Ventilation
Issued 18 November 2003 Resolved
Repair the aft engine compartment vent to allow it to properly close.
Action required: 705 - Other - as specified
Due 9 February 2004
Resolved 12 March 2004
Documentation › Certificates/Documents
Issued 18 November 2003 Resolved
Provide FCC radio operators permits for all the vessel's Captains.
Action required: 705 - Other - as specified
Due 9 February 2004
Resolved 12 March 2004
Navigation › Piloting/Steering
Issued 18 November 2003 Resolved
Rebuild or replace the vessel's steering ram.
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 9 January 2004
Engineering › Bilge Water Management System
Issued 18 November 2003 Resolved
Provide visual indicator for the bilge alarms at the operating station.
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 9 January 2004
Documentation › Logs/Records
Issued 18 November 2003 Resolved
Provide 2692's for the engine, starter, and turbo failures, and for steering failures.
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 9 January 2004
Documentation › Logs/Records
Issued 18 November 2003 Resolved
Provide immediate notification to the Coast Guard upon sustaining a marine casualty per 46 CFR Part 4.
Action required: 705 - Other - as specified
Due 10 December 2003
Resolved 10 December 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 18 November 2003 Resolved
Properly install the engine kill switch at the operating station.
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 9 January 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 18 November 2003 Resolved
Repair or remove the extra water temp gauges.
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 9 January 2004
Electrical › Electrical Distribution System (service)
Issued 18 November 2003 Resolved
Label all electrical switches. LEGACY COMPONENT DESC: Switch
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 10 December 2003
Operations/Management › Passenger Operations
Issued 18 November 2003 Resolved
The Owner, Operator, and Captain failed to maintain the vessel, its gear, and operations such as conducting the required amount of drill in accordance with 46 CFR Subchapter T.
Action required: 705 - Other - as specified
Due 18 November 2003
Resolved 10 December 2003
Documentation › Certificates/Documents
Issued 14 November 2003 Resolved
Upon boarding the vessel prior to carrying passengers on 14 Nov 03, the Captain was asked to produce the COI; however, the COI was not onboard the vessel. LEGACY COMPONENT DESC: Certificate of Inspection
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2003
Resolved 18 November 2003
Documentation › Certificates/Documents
Issued 14 November 2003 Resolved
The vessel failed to complete their annual inspection within the required 3 months before or after the COI's anniversary date. per 176.500(1). LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2003
Resolved 10 December 2003
Communications › Radio Communications
Issued 27 June 2002 Resolved
Provide EPIRB prior to carrying passengers. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 27 July 2002
Resolved 23 July 2002
Engineering › Bilge Water Management System
Issued 27 June 2002 Resolved
Prove proper operation of bilge system. LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 27 July 2002
Resolved 23 July 2002
Documentation › Certificates/Documents
Issued 27 June 2002 Resolved
Provide and post stablility letter. LEGACY COMPONENT DESC: Stability Letter
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 July 2002
Resolved 28 June 2002
Fire Fighting
Issued 14 May 1999 Resolved
Vessel did not have a manual means to secure engine room ventillation for the fixed fire fighting system.
Condition: Unknown
Due 26 July 1999
Resolved 26 August 1999
Documentation
Issued 14 May 1999 Resolved
Vessel had no Certificate of Documentation due to a transfer of ownership.
Condition: Unknown
Due 25 July 1999
Resolved 26 August 1999
Fire Fighting
Issued 14 May 1999 Resolved
Found one B-II portable fire extinguisher to be out of service.
Condition: Unknown
Due 25 July 1999
Resolved 1 July 1999
Documentation
Issued 14 May 1999 Resolved
Vessel did not have a FCC station license to operate their VHF-FM radio.
Condition: Unknown
Due 30 August 1999
Resolved 1 July 1999
Documentation
Issued 14 May 1999 Resolved
Vessel did not have a FCC Safety Installation Certificate.
Condition: Unknown
Due 25 July 1999
Resolved 1 July 1999
Lifesaving
Issued 14 May 1999 Resolved
Found vessel to not have emergency drills log nor crew training in emergency drills. Required vessel to perform emerg drills to marine inspector satisfaction & log them.
Condition: Unknown
Due 26 July 1999
Resolved 26 August 1999
Engineering
Issued 9 March 1999 Resolved
Replace corroded hose clamps in the engine room and ensure double clamps are installed where necessary.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Construction/Loadline
Issued 9 March 1999 Resolved
Remove bimini top prior to operating with passengers or conduct new stability test with top installed (see ref case MI99006232).
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Engineering
Issued 9 March 1999 Resolved
Provide means to secure ventilation (intake/exhaust) for engine room space.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Engineering
Issued 9 March 1999 Resolved
Install flame screen on Racor filter.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Construction/Loadline
Issued 9 March 1999 Resolved
Reattach captive device on forward watertight hatch.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Engineering
Issued 9 March 1999 Resolved
Label emergency fuel shut off valves.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Navigation
Issued 9 March 1999 Resolved
Repair/replace leaking hydraulic hoses/fitting to steering gear ram in lazzerette.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Fire Fighting
Issued 9 March 1999 Resolved
Install visual and audible alarm for Fireboy fixed-fire extinguisher system.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Documentation
Issued 26 March 1997 Resolved
Vessel is prohibited from carrying passengers for hire until Inspection forCertification is completed. 46 CFR 176.500(a) and 176.107(b)
Condition: Unknown
Due 26 March 1997
Resolved 26 March 1997
Navigation
Issued 6 June 1996 Resolved
CORRECT EXISTING EMERGENCY BROADCAST PLACARD TO INCLUDE VESSEL NAME, ENSURING THAT PLACARD COMPLIES WITH VERBAGE IN IFR 46 CFR 184.506.
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Documentation
Issued 6 June 1996 Resolved
PROVIDE ANNUAL INSPECTION LOG FOR LIFESAVING EQUIPMENT _x001C_ IAW IFR 46 CFR185.726.
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Navigation
Issued 6 June 1996 Resolved
ILLUMINATE COMPASS IAW IFR 46 CFR 184.402.
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Accommodation/Occupational Safety
Issued 6 June 1996 Resolved
ENSURE EMERGENCY EXITS/HATCHES ARE LABELED IAW IFR 46 CFR185.606.
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Navigation
Issued 17 May 1996 Resolved
Provide CG-2692 for steering casualty.
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Navigation
Issued 17 May 1996 Resolved
Prove proper operation of steering system prior to carrying passengers for hire.
Condition: Unknown
Due 29 May 1996
Resolved 29 May 1996
Documentation
Issued 17 May 1996 Resolved
Provide evidence of compliance with IFR 46 CFR 183.430, 184.402, 184.506, 185.420, 185.504, 185.506, 185.520, 185.524, 185.604, 185.606, 185.614, 185.720, 185.722, 185.724, 185.726.
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Fire Fighting
Issued 7 December 1995 Resolved
Install and demonstrate proper operation of the FE-241 system indicator light and audible alarm at the operating station; install an automatic engine shutdown actuated by the FE-241 cylinder pressure, and install vent closures for the engine room supply and exhaust ducts.
Condition: Unknown
Due 7 December 1995
Resolved 7 December 1995
Engineering
Issued 4 November 1995 Resolved
PROPERLY LABEL EMERGENCY REMOTE FUEL SHUTOFF VALVES IAW 46CFR185.30-20 TO THE SATISFACTION OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 4 November 1995
Resolved 4 November 1995
Engineering
Issued 4 November 1995 Resolved
INSTALL ENGINE COMPARTMENT VENTILATION DOWN PIPE IAW 46CFR182.20-45 TO THE SATISFACTION OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 4 November 1995
Resolved 4 November 1995
Fire Fighting
Issued 4 November 1995 Resolved
OWNER HAS NOT PROVEN VSL BUILT W/FIRE RETARDANT RESIN; PROPERLY INSTALL CG APPROVED FIXED FIRE SUPPRESSION SYSTEM IAW NVIC 8-87 TO THE SATISFACTION OFA USCG MARINE INSPECTOR; 02 ADDITIONAL B-II PORT FIRE EXTINGUSHERS TO BE ONBOARD WHILE CARRING PASSENGERS UNTIL FIXED FIRE SYSTEM IS INSTALLED.
Condition: Unknown
Due 4 November 1995
Resolved 4 November 1995
Lifesaving
Issued 11 August 1995 Resolved
REPLACE EXISTING RING LIFE BUOY WITH A 24" OR 30" COAST GUARD APPROVED RINGLIFE BUOY.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Construction/Loadline
Issued 5 May 1995 Resolved
RELOCATE BILGE SYSTEM MANIFOLD AND PROVE PROPER OPERATION OF BILGE SYSTEM. MANIFOLD IS NOT READILY ACCESSIBLE, PLANS MUST BE SUBMITTED FOR APPROVAL.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Lifesaving
Issued 5 May 1995 Resolved
RENEW VESSEL NAME MARKINGS AND BUOYANT APPARATUS AND LIFE FLOAT.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Lifesaving
Issued 5 May 1995 Resolved
PROPERLY REPAIR PUNCTURES/HOLES IN BUOYANT APPARATUS AND LIFE FLOAT.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Lifesaving
Issued 5 May 1995 Resolved
CONDUCT UNDERWAY DRILLS IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Lifesaving
Issued 5 May 1995 Resolved
RENEW RETROFLECTIVE TAPE AND VESSEL NAME MARKINGS ON 3 CHILD PFDS AND 1 ADULT PFD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Engineering
Issued 5 May 1995 Resolved
PROPERLY RELOCATE EMERGENCY FUEL SHUT-OFFS IAW 46 CFR 182.20-40(3) AND PROVE PROPER OPERATION.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Lifesaving
Issued 3 May 1994 Resolved
PROPERLY LABEL ADULT PFD STOWAGE WITH TYPE AND QUANTITY.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Engineering
Issued 3 May 1994 Resolved
PROPERLY LABEL FUEL SHUT-OFFS WITH 1-INCH LETTERS TO INCLUDE THE DIRECTION OF OPERATION.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Navigation
Issued 8 November 1991 Resolved
CROP OUT UNUSED HYDRAULIC PIPE LOCATED IN THE HELM CONSOLE.
Condition: Unknown
Due 8 November 1991
Resolved 8 November 1991
Electrical
Issued 8 November 1991 Resolved
RENEW WIRING WITH CRACKED INSULATE LOCATED IN THE HELM CONSOLE WITH AS ORIGINAL LIKE AND KIND (APPROVED SIZE AND TYPE).
Condition: Unknown
Due 8 November 1991
Resolved 8 November 1991
Construction/Loadline
Issued 8 November 1991 Resolved
RENEW STRIP OF FIBERGLASS MATTING THAT HAS DELAMINATED FROM THE FORWARD SIDE OF THE BULKHEAD BETWEEN STORAGE COMPARTMENT & ENGINE ROOM.
Condition: Unknown
Due 8 November 1991
Resolved 8 November 1991
Engineering
Issued 26 May 1991 Resolved
REPLACE RACOR FUEL FILTER PLASTIC DRAIN PLUG WITH METALLIC TYPE.
Condition: Unknown
Due 26 May 1991
Resolved 26 May 1991
Navigation
Issued 26 May 1991 Resolved
PROVIDE REQUIRED NAUTICAL PUBLICATIONS IN ACCORDANCE WITH 46CFR185.20-35.
Condition: Unknown
Due 26 May 1991
Resolved 26 May 1991
Unknown
Issued 26 May 1991 Resolved
REPLACE FUEL VENT FLAME SCREENS WITH 30 X 30 MESH TYPE.
Condition: Unknown
Due 26 May 1991
Resolved 26 May 1991
Fire Fighting
Issued 26 May 1991 Resolved
PROVIDE SERVICING AND PROPERLY MOUNT ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 26 May 1991
Resolved 26 May 1991
Unknown
Issued 20 May 1986 Resolved
CONDUCT ANNUAL SERVICING OF 2 B-II FIRE EXTINGUISHERS.
Condition: Unknown
Due 20 May 1986
Resolved 20 May 1986
Unknown
Issued 20 May 1986 Resolved
OBTAIN ALL FCC LICENSES AND PERMITS AND PLACE ON BOARD, AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 20 May 1986
Resolved 20 May 1986
Unknown
Issued 20 May 1986 Resolved
REPLACE ONE MISSING CHILD'S PERSONAL FLOTATION DEVICE.
Condition: Unknown
Due 20 May 1986
Resolved 20 May 1986
Unknown
Issued 20 May 1986 Resolved
REPLACE MISSING PORTABLE HAND PUMPS, FIRE, AND BILGE PUMP.
Condition: Unknown
Due 20 May 1986
Resolved 20 May 1986
Unknown
Issued 20 May 1986 Resolved
REPAIR OR REPLACE INOPERATIVE STROBE LIGHT FOR BUOYANT APPARATUS.
Condition: Unknown
Due 20 May 1986
Resolved 20 May 1986
Unknown
Issued 10 June 1985 Resolved
PLACE ONBOARD THE VESSEL BUOYANT APPARATUS WITH A TOTAL CAPACITY OF 15 PERSONS. TOTAL PERSONS SHALL BE LIMITED TO 24 UNTIL THIS ITEM IS SATISIFIED.
Condition: Unknown
Due 10 June 1985
Resolved 10 June 1985

Casualty record · 1

22 January 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3932911
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

ADVENTURE I (2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record