OSPREY is a 1985 passenger vessel (inspected). The Coast Guard has recorded 86 inspections since 1985, most recently in March 2026, along with 164 deficiencies and 3 casualty investigations between 2003 and 2019.

Records from 1985 to 2026. Most recent: inspection, 10 March 2026.

Built
1985
Last inspected
10 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WSM6996
250582
Flag
UNITED STATES
367665870
Maury page id
psix-250582

Inspections, by type

…with no type recorded17
Years with a record 40 calendar years (1985–2026)
The 86 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)72.2 ft × 20.8 ft × 6.2 ft
Registered tonnagegross 94 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS INC · STUART, FL, UNITED STATES · built 1985
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT JEFFERSON, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 31 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN6909MMSI 367665870 · active · compulsorily equipped · granted 22 March 2023, expires 22 March 2033
WDH9223MMSI 367665870 · cancelled · compulsorily equipped · granted 8 April 2015, cancelled 20 March 2023
WSM6996MMSI 367001450 · expired · compulsorily equipped · granted 16 December 2004, cancelled 25 April 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 86

10 March 2026 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8325199
27 February 2026 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8317719
1 May 2025 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8126488
2 May 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7904814
8 February 2024 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7860658
15 November 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7824229
13 November 2023 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7824199
18 May 2023 Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7691196
7 March 2023 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7619078
3 November 2022 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7585469
13 October 2022 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7570720
30 April 2021 Administrative Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7188007
6 August 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7026449
2 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6826099
17 August 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6792250
17 August 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6804320
18 July 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6753208
15 March 2019 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6643001
30 August 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6527281
5 June 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6434990
1 May 2017 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6134377
27 October 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6029242
2 May 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5867868
12 September 2015 Type not recorded
No type recorded · USCGC CAMPBELL (WMEC 909) · Activity 5726323
6 May 2014 Annual Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4851830
1 May 2012 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4299660
12 January 2012 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4223522
15 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4208737
27 April 2009 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3462053
16 April 2009 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3453697
27 August 2008 Type not recorded
No type recorded · USCGC SEA HORSE (WPB 87361) · USCG Heartland District (CGD-H) · Activity 3310793
14 April 2008 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3183595
19 April 2007 Hull Examination · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2910863
6 April 2006 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2618003
12 April 2005 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2331824
22 March 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2316254
16 April 2004 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2045253
28 June 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1890710
28 June 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1890712
21 May 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1798116
19 March 2003 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1762287
5 November 2002 Hull Examination · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1701105
17 April 2002 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1606224
21 March 2002 COI Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1492159
3 July 2001 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1067175
20 June 2001 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1379486
26 February 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1447046
13 February 2001 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 825260
15 July 2000 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 105393
7 July 2000 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1447010
30 May 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 41093
26 March 1999 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1437521
23 March 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1457638
7 May 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1125184
20 January 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1113256
20 November 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 775911
11 August 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 783170
28 May 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1107542
6 May 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1098572
22 April 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1099543
2 April 1996 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1077903
4 March 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 28644
3 March 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 100856
25 November 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 21759
7 November 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1192400
2 October 1995 Drydock Extension
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 871653
24 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 879874
27 June 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 877354
4 April 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 839159
6 April 1994 Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 853712
9 March 1994 Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 660370
23 March 1993 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 840380
14 January 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1137465
27 March 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1266532
29 October 1991 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 940188
26 March 1991 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1260351
16 October 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1242305
25 March 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 942662
17 October 1989 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1044776
29 March 1989 Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 896093
28 July 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1342180
4 April 1988 COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 996354
21 April 1987 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1327370
12 November 1986 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1315371
23 April 1986 Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1310874
29 April 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1291271

Deficiency record · 164

03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 1 May 2025 Resolved
Affix retention cables on forepeak and lazarette deck hatches
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2025
Resolved 21 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 May 2025 Resolved
Affix waterlight with 3'-6' line around the body of lifering
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2025
Resolved 21 May 2025
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 1 May 2025 Resolved
Permanently affix wires using metal supports no more than 24" apart as discussed
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2025
Resolved 21 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 1 May 2025 Resolved
Remove Oiled pads from bilges & replace with clean. Remove all standing oil from the bilges
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2025
Resolved 21 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2025 Resolved
Double hose clamp raw water suction on generator
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2025
Resolved 21 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2025 Resolved
Remove wing nuts on battery terminals
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2025
Resolved 21 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 May 2025 Resolved
Service forward bilge valve and provide reach rod for ease of use during an emergency.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2025
Resolved 21 May 2025
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 November 2023 Resolved
SPVs sailing >20 NM & <100 NM must carry a MF radio. HOwever, USCG discontinued 2182 kHz watchkeeping & does not provide Sea Area A2 service. However Sea Area A1 VHF service does extend as much as 100 nm in many locations. Therefore, SPVs sailing up to 100 NM, in addition to the EPIRB, VHF, Navigational Receiver and MF installations mentioned above, carry either: (a) a single sideband radiotelephone installation capable of operating on all of the medium frequency (MF) and high frequency (HF) channels used for distress and safety communications listed in Section 80.905(a)(3)(iii)(A) and capable of DSC operation, or (b) a satellite ship earth station through which continuous distress alerting by satellite is available. Vessel is restricted to operations w/in 20 NM until properly outfitted. CITE: 47CFR§80.905(a)(2)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 November 2024
Resolved 2 May 2025
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 March 2023 Resolved
Fabricate engine room ventilation covers
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 8 June 2023
Resolution: Vent covers installed.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 28 March 2023 Resolved
Repair public address system
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 8 June 2023
Resolution: New PA system installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 March 2023 Resolved
Obtain a 12" Bell that conforms with NAVRULES
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 19 April 2023
Resolution: Vessel purchased bell.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 March 2023 Resolved
Obtain flashlights (1) at operating station (1) at E/R
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2023
Resolved 17 April 2023
Resolution: Purchased flashlights
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 March 2023 Resolved
Repair Anchor Light
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 17 April 2023
Resolution: Anchor light repaired.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 28 March 2023 Resolved
Repair rear window in wheelhouse
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 17 April 2023
Resolution: Rear window in wheelhouse repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 28 March 2023 Resolved
Provide IBA servicing report
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 17 April 2023
Resolution: IBAs re-packed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 March 2023 Resolved
Repair bilge valve IWO collision bulkhead
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 17 April 2023
Resolution: Bilge valve repaired.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 March 2023 Resolved
Repair Fire Pump and prove proper operations
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 17 April 2023
Resolution: Fire pump repaired.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 March 2023 Resolved
Install Satellite Phone prior to ops oceans
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2023
Resolved 8 June 2023
Resolution: See special note
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 March 2023 Resolved
Obtain life jacket lights prior to ops oceans/coastwise
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2023
Resolved 8 June 2023
Resolution: See special note.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 March 2023 Resolved
Obtain aspirin for First Aid Kit
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2023
Resolved 17 April 2023
Resolution: New aspirin purchased.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 March 2023 Resolved
Repair handrail on stbd side IWO MOB door
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 8 June 2023
Resolution: New handrail installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 March 2023 Resolved
Remove/replace extension chord wires in E/R
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 8 June 2023
Resolution: Extension chord removed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 March 2023 Resolved
Obtain updated charts and navigation publications as discussed
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 17 April 2023
Resolution: New charts and pubs purchased.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 August 2020 Resolved
Every vessel subject to the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician once every 5 years. The current inspection report is expired. Vessel is restricted to no more than 1000 ft from shore until inspection is conducted. 47CFR803903
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2020
Resolution: Operator was able to provide the technicians report.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 August 2020 Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. The current endorsement is expired. Vessel is restricted to no more than 1000 ft from shore until proper endorsement is verified. 47CFR80.1005
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2020
Resolution: Operator was able to provide the certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 6 August 2020 Resolved
Marine employees shall establish programs for chemical testing for dangerous drugs on a random basis of crew members on inspected vessels who are required by the vessel's COI. Proof of all crew members being enrolled in the company's drug consortium was not made available during the inspection.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 6 August 2020
Resolved 6 August 2020
Resolution: Onwer was able to provide proof of enrollment in a consortium.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 6 August 2020 Resolved
Alcohol testing must be conducted on each individual engaged or employed on board a vessel who is directly involved in a serious marine incident. The alcohol testing strips on board were expired.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2020
Resolved 6 August 2020
Resolution: Owner explained that his route permits him to use the local law enforcment within the 2 hour requirement but also ordered new testing strips.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 August 2020 Resolved
The master shall ensure that each EPIRB is tested monthly and logged or otherwise documented. No documentation of EPIRB testing was found.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 20 August 2020
Resolution: Observed logging of EPIRB testing.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 6 August 2020 Resolved
Flares must be stowed in a portable watertight container marked as required by 185.614 or in a pyrotechnic locker secured above the freeboard deck in the vicinity of the operating station. The flares were not properly stowed.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 20 August 2020
Resolution: Observed new watertight container with proper markings.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 August 2020 Resolved
Fire pump outlet shall be fitted with a pressure gauge. The gauge on the fire pump was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 20 August 2020
Resolution: Observed new gauge is operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 August 2020 Resolved
Each ring lifebuoy on a vessel must be approved in accordance with 46 CFR 160.050. The grab lines on the port ring lifebuoy are not serviceable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 20 August 2020
Resolution: Observed newly purchased lifebuoy.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 6 August 2020 Resolved
Lifefloats and buoyant apparatus must not be stowed in tiers more than 4 feet high. When stowed in tiers, separate units must be kept apart by spacers. The starboard tier of lifefloats did not have proper spacers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 20 August 2020
Resolution: Observed proper spacers inbetween lifefloats.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 6 August 2020 Resolved
Placards containing instructions for donning life jackets must be posted in conspicuous places regularly accessible and visible to crew and passengers. A donning placard should be placed on the upper deck near the life jacket storage area.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 20 August 2020
Resolution: Observed donning placard.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 6 August 2020 Resolved
When flexible section is a nonconductor of electricity is used on filling pipes, the metallic sections of the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. One of the diesel fill pipes lacks a grounding wire.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 20 August 2020
Resolution: Observed newly installed grounding wire.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 6 August 2020 Resolved
Where a flexibility fill pipe section is necessary, suitable flexible tubing or hose having high resistance to salt water, petroleum oils, heat and vibration may be used. The flexible tubing on the middle fuel fill has a crack and is no longer serviceable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 20 August 2020
Resolution: Observed new flexible tubing on fuel fill.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 August 2020 Resolved
Each stowage container for life jackets must not be capable of being locked. One location is marked that it contains lifejackets is capable of being locked. If this location is no longer used for stowing lifejackets, the markings shall be removed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 20 August 2020
Resolution: Observed the markings were removed.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 2 October 2019 Resolved
Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detection and alarm unit in compliance with §181.450. Smoke detectors currently installed do not meet the requirements of 181.450, which required detectors to be UL217 approved. Verify that installed smoke detectors are of the approved type in each overnight accommodations space. 705: No usage of overnight accommodations
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 October 2019
Resolved 4 October 2019
Resolution: Vessel rep provided documentation of installed detctors UL 217 approval.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 2 October 2019 Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months. Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information. (1) Date of the training; and (2) General description of the training topics.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 24 October 2019
Resolution: Vessel training and indoc program updated the meet all requirments.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Uncovered junction box with exposed wires in aft engine room overhead near the emergency escape hatch. Cover electrical box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 24 October 2019
Resolution: Box covered.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Numerous residential grade plug strips in use throughout the pilot house and upper deck accommodations space. Remove residential grade plug strips.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 24 October 2019
Resolution: All residential plug strips removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Open electrical junction box in the overhead of forward accommodations space above the center top rack. Cover open junction box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 24 October 2019
Resolution: Junction box covered.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical box found hanging from the over head in aft overnight accommodations space in the center area. Mount hanging electrical box.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 24 October 2019
Resolution: Box properly mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 August 2019 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel lost propulsion with 61 POB 46CFR182.200 (17c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2019
Resolution: Verified proper operation of propulsion machinery.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 July 2019 Resolved
The Certificate of Inspection shall, in general be framed under glass or other transparent material and posted in a conspicuous place. The COI is not posted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 8 August 2019
Resolution: Verified COI posted
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 July 2019 Resolved
If a Stability letter is issued in accordance with the requirements of 170.120 of this chapter, it must be posted under glass or other suitable transparent material in the pilothouse. The Stability letter is not posted. 46 CFR 185.12-1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 8 August 2019
Resolution: Verified Stability letter posted near operating station.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 July 2019 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts and nautical publications. The vessel has a 2001 Inland Navigation Rules and 2004 light list onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 8 August 2019
Resolution: Verified upto date publications
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 July 2019 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts and nautical publications. The electronic charts' most recent update is dated 2011.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 8 August 2019
Resolution: Verified upto date charts
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2019 Resolved
The visual indicator must be provided at the operating station to indicate when the automatic bilge pump is operating. The bilge indicator for the aft bunk room is inoperable
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 8 August 2019
Resolution: Verified bilge indicator testing properly
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 July 2019 Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 24 inches in diameter. Two life buoys, located aft and on the starboard side grab lines are not serviceable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 8 August 2019
Resolution: Verified new life buoys onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 18 July 2019 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for lifejackets. Letters and numbers must be at least 2 inches high. Symbols must be at least 4 inches square. The location markings for the child life jackets is illegible.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 8 August 2019
Resolution: Verified proper markings.
01 - Certificates & Documentation › 013 - Documents › Ship specific plans for the recovery of persons from the water
Issued 18 July 2019 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions not mounted at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 22 August 2019
Resolution: Confirmed the mounting of the emergency instructions.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 18 July 2019 Resolved
Each EAP education program must include at least the following elements: display and distribution of the informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. The EAP education material is not displayed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 22 August 2019
Resolution: Confirmed the EAP information was displayed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 July 2019 Resolved
Each ladder used as a means of escape must be mounted at least 180 millimeters (7 inches) from the nearest permanent object in back of the ladder. Rungs must be: at least 405 millimeters (16 inches) in width; and not more than 305 millimeters (12 inches) apart, and uniformly spaced for the length of the ladder with at least 114 millimeters (4.5 inches) clearance above each rung. No ladder for the secondary means of escape through the deck for the overnight accommodations spaces forward and aft. 46 CFR 177.15-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 27 August 2019
Resolution: Owner emailed photos of 3 new fold down steps in fwd and aft berthing and 2 hand holds to assist in escape through deck hatch.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 July 2019 Resolved
Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detection and alarm unit in compliance with 46CFR181.450. Smoke detector is missing from forward berthing. 46 CFR 181.405
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 8 August 2019
Resolution: Verified smoked detector installed
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 30 August 2018 Resolved
Vsl is broadcasting no dimension information (AIS Antenna Position ABCD values equals 0) and no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 November 2018
Resolution: While running a query in VIVS, all information had been updated and AIS was broadcasting the proper information.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 5 June 2018 Resolved
Not to carry passengers until fixed CO2 is serviced. 46CFR181.410
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2018
Resolved 7 June 2018
Resolution: CO2 system serviced and documented.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 5 June 2018 Resolved
Not to carry passengers until stbd shaft is re-packed. 46CFR176.802
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2018
Resolved 7 June 2018
Resolution: Stbd shaft stuffing box repacked.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 June 2018 Resolved
Replace light on port life float. 46CFR180.175 Vessel is restricted to daylight operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2018
Resolved 7 June 2018
Resolution: Light on port life float replaced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 June 2018 Resolved
Connect light to stbd life float. 46 CFR180.175 Vessel is restricted to daylight operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2018
Resolved 7 June 2018
Resolution: Light connected to stbd life float.
Navigation › Piloting/Steering › Magnetic Compass
Issued 5 June 2018 Resolved
Prove operation of magnetic compass light. 46CFR184.402 Vessel is restricted to daylight operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2018
Resolved 7 June 2018
Resolution: Magnetic compass light replaced
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 June 2018 Resolved
Terminate or remove dead end wires throughout as discussed. 46CFR183.05-50(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 7 June 2018
Resolution: Dead end wires removed.
Electrical › Electrical Distribution System (service) › Cable
Issued 5 June 2018 Resolved
Hard wire with ABYC marine grade wire vent and light in forepeak. 46CFR183.10-20
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 7 June 2018
Resolution: Vent and light in forepeak rewired with marine grade wire.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 5 June 2018 Resolved
Mark engine room emergency egress. 46CFR185.606
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 7 June 2018
Resolution: Engine room emergency egress marked.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 June 2018 Resolved
Mark aft ring life buoy. 46CFR185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 7 June 2018
Resolution: Aft ring life buoy marked.
Lifesaving › Lifefloat › Paddle
Issued 5 June 2018 Resolved
Mark paddles for stbd life float. 46CFR185.604(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 7 June 2018
Resolution: Paddles for stbd life float marked.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 5 June 2018 Resolved
Provide ventilation closure for engine room. 46CFR181.20-35
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 7 June 2018
Resolution: Ventilation closure for engine room provided.
Communications › Radio Communications › EPIRB
Issued 5 June 2018 Resolved
Provide valid EPIRB registration. 46CFR184.502 Due prior to operating more than 3nm from shore.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 June 2018
Resolved 7 June 2018
Resolution: EPIRB registration provided.
Fire Fighting › Fire Pumps › Pressure
Issued 5 June 2018 Resolved
Prove proper operation of fire pump pressure guage. 46CFR181.10-1(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 7 June 2018
Resolution: Fire pump guage replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 June 2018 Resolved
Hard wire permanently mounted equipment on aft bulhead of engine room. 46CFR183.10-20
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 7 June 2018
Resolution: Permanently mounted equipment on engine room aft bulkhead hard wired.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 5 June 2018 Resolved
Prior to carrying passengers, properly configure crankcase vapor collection. 46CFR176.25-1
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2018
Resolved 7 June 2018
Resolution: Crankcase vapor collection for deisel engines properly configured.
Engineering › Sea-water System (primary cooling) › Piping
Issued 5 June 2018 Resolved
Remove hose in engine room stbd side overboard as discussed. 46CFR176.802
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 7 June 2018
Resolution: Stbd side overboard hose in engine room removed and capped.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 June 2018 Resolved
Replace 10% vessel's life jackets in 2018 and provide proposal for full replacement (i.e. 10% per year). 46CFR180.71
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2018
Resolved 7 June 2018
Resolution: 10%/13 life jackets replaced. Accepted verbal proposal to replace 13 each year until old life jackets are phased out; written proposal to follow.
Engineering › Fuel Oil Service System › Valve
Issued 1 May 2017 Resolved
The fuel shutoff valve for port fuel tank inoperable; make operable.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 May 2017
Resolution: Crew was able to make shutoff valve operable.
Engineering › Fuel Oil Service System › Valve
Issued 1 May 2017 Resolved
Label fuel shutoff valve location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 9 May 2017
Resolution: Fuel shutoff valve was labeled.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 1 May 2017 Resolved
Install operable fuel gage IAW existing T cite, 46CFR181.10-10(c).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 9 May 2017
Resolution: Gage installed on fire pump and pressure was 60 psi when hoses pressed up.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2017 Resolved
Dead end wires in Lazarette shall be covered with electrical tape and placed in electrical box mounted.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 9 May 2017
Resolution: Wires were used for installing hot water heater.
Documentation › Logs/Records › Drug Test Records
Issued 1 May 2017 Resolved
Provide drug test record for all crewmembers.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 9 May 2017
Resolution: Reviewed drug testing enrollment paperwork.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 1 May 2017 Resolved
Provide cover in open space on distribution panel IAW existing T cite 46CFR183.10-30(a).
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 9 May 2017
Resolution: Blank was installed in distribution panel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2017 Resolved
Hard wire microwave and halogen light.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 9 May 2017
Resolution: Electrical strip was removed. Crew found that microwave was already hard wired and not plugged into strip.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 1 May 2017 Resolved
10 gallon tank in lazarette shall be removed.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 9 May 2017
Resolution: 10 gal hot water heater was installed.
Lifesaving › Lifebuoys › Approval
Issued 1 May 2017 Resolved
Replace 02 life buoys due to missing plug.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 9 May 2017
Resolution: New RLB were installed.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 2 May 2016 Resolved
50 passenger IBA on port side is overdue for annual maintenance. Provide proof of purchase or send IBA out for maintenance. Vessel may carry 116 passengers until IBA compliance is 100%.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 11 May 2016
Resolution: IBA has been removed from the vessel and 02 LFs (22 passengers each) have been installed back on the vessel. Vessel has 04 LFs on board.
Fire Fighting › Fire Pumps › Pressure
Issued 2 May 2016 Resolved
Firepump pressure gauge is inoperable. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 11 May 2016
Resolution: Gauge was replaced.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 2 May 2016 Resolved
Engineroom, bunk room aft, and bunk room fwd are not labeled. Label all hatches per ref.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 11 May 2016
Resolution: All emergency exits have been properly labled.
Engineering › Generator (propulsion-electric) › Measurement Circuitry
Issued 2 May 2016 Resolved
Generator is missing amp metter. Install amp meter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 11 May 2016
Resolution: Amp meter installed.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 2 May 2016 Resolved
Emergency lighting auto function not installed. Install auto activation function for emergency lighting.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 11 May 2016
Resolution: Auto activated lighting installed.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 2 May 2016 Resolved
Vessel is missing draft marks. Install draft marks during next dry dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2019
Resolved 22 August 2019
Resolution: Observed draft marks.
Documentation › Certificates/Documents › FCC SSL
Issued 2 May 2016 Resolved
Station License is missing. Provide station license.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 6 May 2016
Resolution: Copy of FCC Station License certificate was provided.
Lifesaving › Lifefloat › Serviceable
Issued 6 May 2014 Resolved
Life float on port side on wheelhouse has a hole in the core.
Action required: 705 - Other - as specified
Due 20 May 2014
Resolved 23 May 2014
Resolution: Satisfactory repair was made to LF.
Operations/Management › Passenger Operations › Safety Orientation
Issued 6 May 2014 Resolved
Upper deck passenger limit is not marked.
Action required: 705 - Other - as specified
Due 20 May 2014
Resolved 23 May 2014
Resolution: Upper deck passenger limit marking placard was installed.
Engineering › Fuel Oil Service System › Ventilation
Issued 6 May 2014 Resolved
Fuel vent screens are wasted.
Action required: 705 - Other - as specified
Due 20 May 2014
Resolved 23 May 2014
Resolution: Fuel vent screens were renewed.
Engineering › Electric Propulsion System › Battery
Issued 6 May 2014 Resolved
Battery Box bottoms are rotten.
Action required: 705 - Other - as specified
Due 20 May 2014
Resolved 23 May 2014
Resolution: New battery box bottoms were installed on both port and starbaord sides.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 6 May 2014 Resolved
Starboard shaft packing has excessive leaking.
Action required: 705 - Other - as specified
Due 20 May 2014
Resolved 23 May 2014
Resolution: Starboard shaft packing was tightened.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 6 May 2014 Resolved
Sewage line in lazarette was improperly intstalled and is leaking.
Action required: 705 - Other - as specified
Due 20 May 2014
Resolved 23 May 2014
Resolution: Sewage line in lazerette was properly installed.
Engineering › Steering Gear System › Hydraulic Hose
Issued 6 May 2014 Resolved
Hydraulic hose on port side sterering ram needs replacement.
Action required: 705 - Other - as specified
Due 20 May 2014
Resolved 23 May 2014
Resolution: Hydraulic hose on port side steering ram was renewed with approved hose.
Lifesaving › Lifefloat › Serviceable
Issued 1 May 2012 Resolved
Life floats weak link and line is tangled up, too many L/F to one weak link, paddles are all wasted, float free arrangement is being blocked by wood cover and two water lights for the L/F are inoperable. Make repair/replace all above items.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2012
Resolved 2 May 2012
Resolution: Properly stowed all lines and installed weak links needed for amount of L/F, provided 2 paddles per L/F with name, ensured float free arrangement, provided working waterlights for all L/F.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 1 May 2012 Resolved
life jacket lights are all expired. Provide approved lights prior to carrying passengers outside 20 miles from harbor of safe refuge.
Action required: 705 - Other - as specified
Resolved 2 May 2012
Resolution: Provided approved lights
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 1 May 2012 Resolved
Smoke detector in FWD sleeping accommodation inoperable. provide working smoke detector for FWD sleeping accommodation.
Action required: 705 - Other - as specified
Due 1 May 2012
Resolved 2 May 2012
Resolution: provided working smoke detector for FWD sleeping accommodation.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 1 May 2012 Resolved
Demonstrate ability to recover a helpless person from the water in the event of a man overboard.
Action required: 705 - Other - as specified
Due 16 May 2012
Resolved 15 May 2012
Resolution: Provided platform for ladder that will allow crew to recover helpless person from the water in the event of a man overboard.
Documentation › Certificates/Documents › Stability Letter
Issued 15 December 2011 Resolved
THE VESSEL'S OWNER/OPERATOR HAS NOT REQUESTED AN INITIAL OR UPDATED STABILITY LETTER OR HAS NOT CERTIFIED COMPLIANCE WITH THE REVISED STABILITY CRITERIA FOR ASSUMED AVERAGE WEIGHT PER PERSON (AAWPP) OF 185 POUNDS. BASED UPON A WEIGHT RATIO CALCULATION, THE VESSEL'S CAPACITY IS THEREFORE LIMITED TO: 136 PERSONS(PASSENGERS AND CREW) OF WHICH 64 MAYBE ON THE UPPER DECK
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 12 January 2012
Resolution: Owner/operator selected the weight ratio reduction option on the Stability Change Request Letter.
Lifesaving › Lifefloat › Serviceable
Issued 6 April 2006 Resolved
Renew one unservicable 22-person lifefloat and one unservicable 8-person lifefloat. Until completed, vessel reduced to a maximum of 119 passengers and 122 total persons.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 8 May 2006
Resolution: Examined new 22-person and 8-person Jim-Buoy life floats. All sat.
Lifesaving › Lifefloat › Serviceable
Issued 6 April 2006 Resolved
Repair damaged foam on one 22-person lifefloat using approved materials.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 8 May 2006
Resolution: Examined repairs to life float. All sat.
Lifesaving › Lifefloat › Float-free Link
Issued 6 April 2006 Resolved
Restow all lifefloats so weak links, pendants and spacer slats are properly installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 8 May 2006
Resolution: Examined installation of life floats. All sat.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 6 April 2006 Resolved
Renew or repair jacket water temperature and RPM gauges for center MDE.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 8 May 2006
Resolution: Engine-mounted gauges not used on electronic model of vessel''s MDE''s. Cleared requirement.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 6 April 2006 Resolved
Provide current navigation pubs.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 8 May 2006
Resolution: New pubs ordered. All sat.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 12 April 2005 Resolved
Provide a recently calculated magnetic compass deviation table.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 30 June 2005
Resolution: Examined satisfactory dev table.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 12 April 2005 Resolved
Provide a log or other acceptable documentation for monthly examination of portable fire extinguishers, or provide documehtation of professional servicing.
Action required: 705 - Other - as specified
Due 15 May 2005
Resolved 30 June 2005
Resolution: Examined satisfactory extinguisher maintenance tags.
Engineering › Bilge Water Management System › Interface Detector
Issued 16 April 2004 Resolved
Prove proper operation of the forward bunk room high bilge level alarm.
Due 3 May 2004
Resolved 3 May 2004
Resolution: Proved proper operation
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 16 April 2004 Resolved
Tighten main stbd main engine stuffing box.
Due 3 May 2004
Resolved 3 May 2004
Resolution: Tightened stbd main engine stuffing box.
Engineering › Steering Gear System › Rudder Stock
Issued 16 April 2004 Resolved
Tighten the stbd rudder post packing
Due 3 May 2004
Resolved 3 May 2004
Resolution: Tightened stbd rudder post packing
Electrical › Lighting (emergency)
Issued 19 March 2003 Resolved
Install emergency lighting fixture at exit ways to both below deck overnight accomodations areas LEGACY COMPONENT DESC: Lighting Fixture
Due 4 April 2003
Resolved 30 April 2003
Resolution: Emergency lighting installed.
Electrical › Electrical Distribution System (service)
Issued 19 March 2003 Resolved
Replace circuit breaker to distribution panel. LEGACY COMPONENT DESC: Circuit Breaker
Due 4 April 2003
Resolved 30 March 2003
Resolution: Circuit breaker replaced.
Documentation › Logs/Records
Issued 19 March 2003 Resolved
Maintain training Logbook. LEGACY COMPONENT DESC: Logbook (official)
Due 4 April 2003
Resolved 30 April 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 19 March 2003 Resolved
Replace fuel vent screens to fuel fill lines. LEGACY COMPONENT DESC: Vent Pipe
Due 4 April 2003
Resolved 30 April 2003
Resolution: Fuel vents replaced.
Operations/Management › Drills/Instruction
Issued 19 March 2003 Resolved
Conduct man overboard recovery drill with attending USCG Marine Inspector. LEGACY COMPONENT DESC: Man Overboard Recovery
Due 4 April 2003
Resolved 30 April 2003
Resolution: Conducted sat man overboard drill test.
Fire Fighting › Grease Extraction Hood
Issued 21 March 2002 Resolved
Install a grease extraction hood above galley grill that meets UL 710 with a fixed fire system meeting NFPA 17 or 17A or remove galley grill from vessel. The grill shall not be used until corrected and cleared by an attending Marine Inspector.
Condition: Unknown
Due 21 October 2002
Resolved 17 April 2002
Resolution: Cleared Discrepancy IAW G-MSE-4 Policy Ltr 1-99 dtd 26Feb99. Vsl has (2) B-II portable extinguishers that are mounted & readily accessible. Operational measures in place to visually inspect & clean duct & hood weekly & conduct training for galley fires.
Fire Fighting › Fire Hoses
Issued 21 March 2002 Resolved
Replace (1) 1.5 inch fire hose prior to operating. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Due 21 April 2002
Resolved 9 April 2002
Resolution: Corrected.
Engineering › Sea-water System (primary cooling)
Issued 21 March 2002 Resolved
Provide double hose clamps on all raw-water hoses prior to carrying passengers LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 21 April 2002
Resolved 9 April 2002
Resolution: Corrected
Engineering › Shafting/Propeller Arrangements
Issued 21 March 2002 Resolved
Renew broken packing gland nut on starboard main diesel engine prior to carrying passengers. LEGACY COMPONENT DESC: Stern Gland
Condition: Unknown
Due 21 April 2002
Resolved 9 April 2002
Resolution: Corrected
Electrical › Electrical Distribution System (service)
Issued 21 March 2002 Resolved
Remove deadend wires in way of starboard engine. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 21 April 2002
Resolved 9 April 2002
Resolution: Corrected.
Engineering › Lubricating Oil Storage/Transfer System
Issued 21 March 2002 Resolved
Replace oil transfer hoses and plastic garden hose fittings with fittings ans hose oof an approved type. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 21 April 2002
Resolved 9 April 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 21 March 2002 Resolved
Provide a junction box for wires leading to 110v constavolt trickle charger. LEGACY COMPONENT DESC: Junction Box
Condition: Improper Installation
Due 21 April 2002
Resolved 9 April 2002
Resolution: Corrected.
Construction/Loadline › Structures
Issued 21 March 2002 Resolved
Remove decking or re-fit decking in way of center main diesel engine to allow access to shaft packing gland for closer inspection and access by the crew in case of emergency. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Design Flaw
Due 21 April 2002
Resolved 9 April 2002
Resolution: Corrected.
Engineering › Sea-water System (primary cooling)
Issued 21 March 2002 Resolved
Renew port engine raw water intake hose and provide double hose clamps prior to carrying passengers. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 21 April 2002
Resolved 9 April 2002
Resolution: Corrected.
Engineering › Sea-water System (primary cooling)
Issued 21 March 2002 Resolved
Remove temporary hose and piping supports in way of all main diesel engines where 1/2 rope is lashed around hoses and piping. LEGACY COMPONENT DESC: Piping
Condition: Design Flaw
Due 21 April 2002
Resolved 9 April 2002
Resolution: Corrected.
Lifesaving › Lifebuoys
Issued 21 March 2002 Resolved
Re-mount floating water lights with flush mount screws. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper Installation
Due 21 April 2002
Resolved 9 April 2002
Resolution: Corrected
Lifesaving › Lifejacket/PFD (Type I)
Issued 21 March 2002 Resolved
Renew retro-reflective material on PFDs where needed. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Unknown
Due 21 April 2002
Resolved 9 April 2002
Resolution: Corrected
Lifesaving › Lifebuoys
Issued 21 March 2002 Resolved
Make permanent repairs to damaged life floats using the manufacturer's patch kit to the satisfaction of an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 21 April 2002
Resolved 9 April 2002
Resolution: Corrected
Documentation › Manuals/Policy Documentation
Issued 21 March 2002 Resolved
Begin a training and life saving equipment maintenance log. LEGACY COMPONENT DESC: Instructions for On-board Maintenance (lifesaving)
Condition: Improper/Lack of Maintenance
Due 21 April 2002
Resolved 9 April 2002
Resolution: Log Started
Electrical › Lighting (service)
Issued 21 March 2002 Resolved
Provide covers for light fixture in salon. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 21 April 2002
Resolved 9 April 2002
Resolution: Corrected
Lifesaving › Lifejacket/PFD (General)
Issued 21 March 2002 Resolved
Renew retro-reflective tape on life floats. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 21 April 2002
Resolved 9 April 2002
Resolution: Corrected
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 21 March 2002 Resolved
Renew canvass on berths as necessary. LEGACY COMPONENT DESC: Berth
Condition: Improper/Lack of Maintenance
Due 21 April 2002
Resolved 9 April 2002
Resolution: Corrected
Documentation › Logs/Records
Issued 21 March 2002 Resolved
Provide proof of drug testing program. LEGACY COMPONENT DESC: Drug Test Records
Condition: Unknown
Due 21 April 2002
Resolved 9 April 2002
Resolution: Corrected.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 March 2002 Resolved
Provide approved plans for installed CO2 fixed fire fighting system protecting the engine room.
Condition: Placed in Improper Service
Due 21 April 2002
Resolved 21 May 2002
Resolution: Corrected.
Engineering › Sea-water System (primary cooling)
Issued 21 March 2002 Resolved
Remove plastic raw water cooling piping for all three Main Diesel Engines and renew piping in accordance with the manufacturer's specifications using approved materials. LEGACY COMPONENT DESC: Piping
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 March 2003
Resolved 30 April 2003
Resolution: Item corrected.
Documentation › Logs/Records › MIS Form
Issued 21 March 2002 Resolved
Provide proof that the annual MIS report has been submitted to Coast Guard Headquarters for calendar year 2001.
Condition: Unknown
Due 21 April 2002
Resolved 11 April 2002
Resolution: Corrected.
Construction/Loadline
Issued 20 June 2001 Resolved
Prove proper operation of bilge alarms in lazerette and accomodation space.
Condition: Unknown
Due 20 June 2001
Resolved 25 June 2001
Lifesaving
Issued 20 June 2001 Resolved
Replace worn lines and painter on lifefloats on upper deck.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Lifesaving
Issued 20 June 2001 Resolved
Provide current hydrostatic release for EPIRB.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Lifesaving
Issued 26 March 1999 Resolved
Replace/renew light & line on aft, 2nd deck ring buoy.
Condition: Unknown
Due 31 March 1999
Resolved 16 April 1999
Lifesaving
Issued 26 March 1999 Resolved
Provide drug program for review IAW Drug Program Audit Sheet.
Condition: Unknown
Due 31 March 1999
Resolved 16 April 1999
Accommodation/Occupational Safety
Issued 26 March 1999 Resolved
Re-stencil Emergency Escapes.
Condition: Unknown
Due 31 March 1999
Resolved 16 April 1999
Lifesaving
Issued 26 March 1999 Resolved
Re-stencil PFC Stowage locations.
Condition: Unknown
Due 31 March 1999
Resolved 16 April 1999
Lifesaving
Issued 26 March 1999 Resolved
Provide proper FCC approved Class 1 EPIRB, 406 Mhz, NOAA registered, prior to operating.
Condition: Unknown
Due 31 March 1999
Resolved 16 April 1999
Lifesaving
Issued 26 March 1999 Resolved
Shift L/F lights (4) to a location that allows float-free capability._x001C_
Condition: Unknown
Due 31 March 1999
Resolved 16 April 1999
Lifesaving
Issued 22 April 1997 Resolved
Repair one 22 person life float using Jim-Buoy approved patch kit. Also_x001C_ renew retro-reflective tape._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1997
Resolved 29 May 1997
Lifesaving
Issued 22 April 1997 Resolved
Renew battery in waterlight for 6 person life float._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 April 1997
Resolved 7 May 1997
Lifesaving
Issued 22 April 1997 Resolved
Renew all three ring buoys._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 April 1997
Resolved 7 May 1997
Fire Fighting
Issued 22 April 1997 Resolved
Recharge B-II fire ext located near galley.
Condition: Unknown
Due 29 April 1997
Resolved 7 May 1997
Engineering
Issued 4 April 1995 Resolved
Open control air receiver for internal examination.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Lifesaving
Issued 4 April 1995 Resolved
Replace hydrostatic release on EPIRB.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Lifesaving
Issued 4 April 1995 Resolved
Replace handline on ring lifebuoys located in way of aft and port side of wheelhouse.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Lifesaving
Issued 4 April 1995 Resolved
Remake seapainter to lifefloats as per 46 CFR 180.20-1(a)(5)(ii). The floats are presently made up in series.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Fire Fighting
Issued 4 April 1995 Resolved
Service one B-II fire extinguisher in wheelhouse. Also service Halon system in Engineroom. _x001C_ (New extinguishers, but no tags showing they had been serviced)
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Documentation
Issued 4 April 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Lifesaving
Issued 4 April 1995 Resolved
Capacity of vessel reduced to 72 persons on Oceans Route and 144 persons onCoastwise route until one additional 6 man lifefloat is added.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Lifesaving
Issued 4 April 1995 Resolved
Capacity of vessel reduced to 153 total persons until 1 additional approvedadult lifejacket is placed on board the vessel.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Electrical
Issued 23 March 1993 Resolved
Missing battery box cover replaced following day.
Condition: Unknown
Due 14 May 1993
Resolved 14 May 1993
Navigation
Issued 4 April 1988 Resolved
DEMONSTRATE PROPER OPERATION FO RAYTHEON VHF-FM RADIO.
Condition: Unknown
Due 4 April 1988
Resolved 4 April 1988
Lifesaving
Issued 4 April 1988 Resolved
PROVIDE 6 ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 4 April 1988
Resolved 4 April 1988
Engineering
Issued 4 April 1988 Resolved
INSTALL GOOSENECK PIPE ON LUBE OIL TANK VENT.
Condition: Unknown
Due 4 April 1988
Resolved 4 April 1988
Lifesaving
Issued 4 April 1988 Resolved
PROVIDE 100 ADDITIONAL ADULT PFD'S WITH APPROVED LIGHTS.
Condition: Unknown
Due 4 April 1988
Resolved 4 April 1988
Engineering
Issued 4 April 1988 Resolved
DEMONSTRATE PROPER OPERATION OF FIRE MAIN, BILGE, MAIN PROPULSION, PRIMARY POWER, AND DECK MACHINERY SYSTEMS.
Condition: Unknown
Due 4 April 1988
Resolved 4 April 1988
Lifesaving
Issued 23 April 1986 Resolved
THE TWO LIFE RAFTS HAVE NOT BEEN SERVICED WITHIN THE LAST YEAR. HAVE BOTH SERVICED BY AN AUTHORISED COMPANY AND REPORT THE SERVICE DATE TO THE OCMI.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986

Casualty record · 3

28 June 2003Routine · role: Involved in a Marine Casualty · 1 injured · activity 1890710
14 April 2010Routine · role: Transiting Vicinity of Primary Subject · activity 3717862
17 August 2019Routine · role: Involved in a Marine Casualty · activity 6804320
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

YANKEE FREEDOM (2003–2019). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.