MAURY USCG vessel records Sign in
← All vessels

SOUND BOUND EXCEL

SOUND BOUND EXCEL is a 1985 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 1985, most recently in April 2026, along with 103 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 8 April 2026.

Built
1985
Last inspected
8 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP8189
251055
Flag
UNITED STATES
367554270, 368388270
Maury page id
psix-251055

Inspections, by type

…with no type recorded12
Years with a record 34 calendar years (1985–2026)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 19.0 ft × 7.0 ft
Registered tonnagegross 46 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBONNER YACHTS · WETUMPKA, AL, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Simplified, Gross Ton
37 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP8189MMSI 368388270 · active · compulsorily equipped · granted 24 September 2024, expires 24 September 2034
WDN8326MMSI 367554270 · active · compulsorily equipped · granted 27 May 2023, expires 27 May 2033 · licensed under a name not among this hull’s recorded names (not shown)
WDG6174MMSI 367554270 · expired · compulsorily equipped · granted 21 November 2012, cancelled 21 January 2023 · licensed under a name not among this hull’s recorded names (not shown)
WDD2639MMSI 367117880 · expired · compulsorily equipped · granted 31 May 2006, cancelled 6 August 2016 · licensed under a name not among this hull’s recorded names (not shown)
WAD5646MMSI not assigned · expired · compulsorily equipped · granted 10 May 1994, cancelled 26 September 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 82

8 April 2026 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8344766
6 April 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8333936
16 April 2025 COI Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8105122
9 October 2024 Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8016709
15 May 2024 COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7912728
29 November 2023 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7831266
23 October 2023 Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7812952
8 June 2023 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7703572
21 October 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7337213
15 June 2021 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7226049
14 June 2020 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6980988
8 November 2019 In-Service Inspection · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6851987
29 April 2019 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6672678
8 April 2019 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6656367
17 December 2018 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6598746
28 July 2018 Type not recorded
No type recorded · Station Chatham · USCG Northeast District (CGD-NE) · Activity 6493856
16 May 2018 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6416710
9 May 2018 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6400520
13 October 2017 Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6287041
18 May 2017 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6152703
18 May 2017 In-Service Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6177739
12 December 2016 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6056629
22 December 2015 Deficiency Check · Internal Structural Exam · In-Service Inspection · Hull Examination · Drydock Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5785939
9 November 2015 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5763117
15 September 2011 Administrative Inspection · Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4146176
31 May 2007 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2990390
9 May 2006 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2644437
3 February 2005 Hull Examination · COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2285475
12 May 2004 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2065091
4 February 2003 Plan Review "T" Boat · Re-Inspection · Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1739623
3 July 2002 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1638126
17 July 2001 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1373549
19 January 2001 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1412226
17 April 2000 COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1395444
26 August 1999 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1115749
3 August 1999 Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1408351
7 May 1999 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1411913
15 January 1999 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1416836
24 June 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 727513
15 May 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 82434
29 April 1998 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1430574
8 December 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 668730
19 May 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1383739
19 May 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1461818
2 January 1997 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1427307
4 December 1996 Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1447658
23 April 1996 Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1445083
20 June 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 877530
28 March 1995 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 854422
1 December 1994 Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 839785
13 June 1994 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1330956
4 April 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 668728
14 March 1994 Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 668729
31 January 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 98035
6 May 1993 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 834331
24 February 1993 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1143595
13 July 1992 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1268335
9 April 1992 Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1262373
16 September 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1252252
18 July 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1308448
16 May 1991 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1244611
28 February 1991 Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 900813
28 February 1991 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 945388
27 June 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1228513
23 May 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1224866
2 May 1990 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 915477
22 November 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1236932
30 August 1989 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 892575
14 August 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1038532
15 June 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1203750
19 May 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 886678
2 May 1989 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1350178
7 February 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1040218
17 November 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1204297
17 November 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1208729
19 October 1988 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1199961
11 April 1988 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1341533
9 February 1988 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1025301
9 December 1986 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1023860
10 November 1986 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1322921
21 April 1986 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1306290
7 November 1985 Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 990029

Deficiency record · 103

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 April 2025 Resolved
Employees must be enrolled in chemical testing program. Provide proof of enrollment prior to pax.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2025
Resolution: Vessel sent an email with a photo of the enrollment ald all was in full compliance.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2025 Resolved
Battery Charger must be equipped with Amp Meter within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2025
Resolved 18 August 2025
Resolution: Vessel sent an email showing the amp meter and the battery charger.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 April 2025 Resolved
Main Engines must have machinery guards around the belts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2025
Resolved 18 August 2025
Resolution: Vessel sent an email with pictures showing the newly installed guards.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 May 2024 Resolved
Update EPIRB registration with new call sign. 46CFR180.64
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2024
Resolution: Received photos
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2024 Resolved
Port engine has a pinhole leak in the cooling water discharge line. Replace section of wasted piping. 46CFR182.700
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2024
Resolution: eceived photo
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 May 2024 Resolved
Each Buoyant Apparatus must be fitted with a lifeline, pennants, a painter and a light. Replace wasted light painter on buoyant apparatus and add lights to buoyant apparatus's without lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2024
Resolution: Received Photo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 May 2024 Resolved
An adult life Jacket shal be provided for all passengers listed on the COI. Three Jim Bouy life jackets were destroyed during the COI inspection. Vessel passenger count is limited to 44 total person until the 3 life jackets are replaced. 46CFR180.71(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2024
Resolution: Received photo
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 May 2024 Resolved
The collision bulkhead is a watertight bulkhead. The collision bulkhead has two penetrations for hydraulic hoses that are not watertight. Make penetrations watertight. 46CFR178.310(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2024
Resolution: Received photo
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 May 2024 Resolved
Vessel is required to carry day shapes in accordance with NAVRULES Part C. Provide day shapes for lighting arrangements available on the vessel's mast.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2024
Resolution: Received photo
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 October 2023 Resolved
Vessel is required to complete a Hull/ISE prior to 31OCT23 as noted on the vessel's COI. Vessel owner can not secure a shipyard to haul and block the vessel until after the 31Oct23 deadline. Vessel is not allowed to carry passengers until the vessel is hauled and inspected by a Coast Guard marine inspector for credit dry dock. 46CFR176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2023
Resolution: Completed Hull/ISE
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2019 Resolved
Shaft and cutlass bearings need to be repaired and or replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2019
Resolved 25 November 2019
Resolution: Shaft has been re-aligned and cutlass bearings replaced.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 April 2019 Resolved
FWD hatch IWO deck, wood rot was found. Remove or replace in-kind. Vessel Rep shall repair or replace by credit dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2019
Resolved 27 September 2019
Resolution: This has been repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2019 Resolved
Aft steering, port side rudder post is leaking water.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2019
Resolved 29 April 2019
Resolution: Rudder post tighted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 April 2019 Resolved
STBD fuel line is wasted IWO fuel tank supply line. Replace Fuel hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2019
Resolved 29 April 2019
Resolution: Fuel pipe replaced.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 April 2019 Resolved
FWD htach is leaking. Replace gasket.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2019
Resolved 29 April 2019
Resolution: New gasket material installed.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 17 December 2018 Resolved
Replace all survival crafts.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2019
Resolved 8 April 2019
Resolution: Vessel properly installed 04 new lifefloats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 December 2018 Resolved
Replace life ring IWO of pilot house.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2019
Resolved 8 April 2019
Resolution: Vessel installed new life ring with waterlight near the pilot house.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 December 2018 Resolved
Conduct drill PTCP.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2019
Resolved 29 April 2019
Resolution: Vessel conducted drills.
Lifesaving › Lifefloat › Float Free
Issued 9 May 2018 Resolved
Life floats on vessel are not properly rigged for float free arrangement. Rerigg the lines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2018
Resolved 16 May 2018
Resolution: Vessel properly rigged the lifefloats to allow for float free operation.
Lifesaving › Lifefloat › Lifeline
Issued 9 May 2018 Resolved
Vessel's lifefloats lifelines were found broken. Repair or replace with a repair kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2018
Resolved 16 May 2018
Resolution: Vessel replaced its 10 person lifefloat with a better condition 12 person lifefloat.
Lifesaving › Lifefloat › Paddle
Issued 9 May 2018 Resolved
Restencil life float paddles with vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2018
Resolved 16 May 2018
Resolution: Vessel restenciled vessel's name on all paddles for the lifefloats.
Lifesaving › Lifefloat › Float Free
Issued 12 December 2016 Resolved
Lifefloats are not properly separated with wood, etc. Space the lifefloats so they will not stick together.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 18 May 2017
Resolution: All life floats are correctly separated and secured.
Lifesaving › Lifefloat › Serviceable
Issued 12 December 2016 Resolved
Lifefloats are slightly wasted and the foam insulation is showing. Repair with an approved repair kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 18 May 2017
Resolution: Vessel rep repaired life floats with approved repair kit.
Lifesaving › Lifefloat › Retroreflective Material
Issued 12 December 2016 Resolved
Lifefloats are missing reflective tape. Provide new reflective material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 18 May 2017
Resolution: Reflective tape has been installed.
Communications › Radio Communications › EPIRB
Issued 12 December 2016 Resolved
The EPIRB hydrostatic release date is not scratched out. Scratch out dates to show date of expiration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 18 May 2017
Resolution: Epirb has been checked for proper labeling.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 12 December 2016 Resolved
Vessel was unable to complete a man overboard drill and fire drill. Vessel will need to complete drills prior to taking passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2016
Resolved 18 May 2017
Resolution: Wintessed satisfactory drills
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 December 2016 Resolved
Vessel's bilge alarms are missing labels on the vessel's operating station. Provide missing labels to distiguish which alarm is where.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 18 May 2017
Resolution: Vessel bilge lables have been installed.
Deck/Cargo › Towing › Chocks
Issued 22 December 2015 Resolved
FWD Bit has large crack down center of bit. Repair or replace bit in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2015
Resolved 9 June 2016
Resolution: Captain contacted MSD to inform unit that the fwd bit had been repaired.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 22 December 2015 Resolved
Halon system needs to be serviced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2016
Resolved 10 May 2016
Resolution: Halon system has been serviced by local fire company.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 December 2015 Resolved
repair life float lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2016
Resolved 10 May 2016
Resolution: Life float light has been repaired.
Communications › Radio Communications › EPIRB
Issued 9 November 2015 Resolved
AVH01: Replace hydro release for EPIRB.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2015
Resolved 22 December 2015
Resolution: Replaced hydro release.
Communications › Radio Communications › EPIRB
Issued 9 November 2015 Resolved
AVH02: Update EPIRB Registration.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2015
Resolved 22 December 2015
Resolution: Updated epirb registration.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 9 November 2015 Resolved
AVH03: Service Halon system for engineroom.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2015
Resolved 9 June 2016
Resolution: Halon was serviced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 November 2015 Resolved
AVH04: Replace life float lights (2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2015
Resolved 9 June 2016
Resolution: Light has been fixed.
Deck/Cargo › Holds/Tanks › Hatch
Issued 9 November 2015 Resolved
AVH05: Port & Stbd hatch cover securring chains need to be replaced
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2015
Resolution: Replaced the securing chains for the hatch covers.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 9 November 2015 Resolved
AVH06: Service all bilge pumps.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2015
Resolution: Serviced one and replaced the other bilge pump, all sat.
Engineering › Fuel Oil Service System › Valve
Issued 9 November 2015 Resolved
AVH07: Lable all F/O cutoff for MDE's.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2015
Resolution: Labeled the F/O cutoff.
Engineering › Fuel Oil Service System › Valve
Issued 9 November 2015 Resolved
AVH08: Repair F/o handle in aft compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2015
Resolution: Replaced F/O cutoff handle.
Fire Fighting › Fire Main › Material
Issued 9 November 2015 Resolved
AVH09: Fire pump has a non-approved hose, replace hose with approved hose.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2015
Resolution: Replaced hose with approved type.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Block
Issued 9 November 2015 Resolved
AVH10: SSDG engine mounts need to be secured properly.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2015
Resolution: Properly secured SSDG mounts.
Stability › Watertight Integrity › General
Issued 15 September 2011 Resolved
Hatch on focsle is not watertight. Properly repair hatch to make watertight.
Action required: 705 - Other - as specified
Due 30 April 2012
Resolved 23 March 2012
Resolution: Received photo and email from owner regarding the repair of the hatch on the focsle. Deficiency cleared.
Engineering › Bilge Water Management System › Valve
Issued 15 September 2011 Resolved
Install positive action valve on stbd ovbd discharge for electric sump pump.
Action required: 705 - Other - as specified
Due 30 April 2012
Resolved 12 March 2012
Resolution: Positive action valve installed. Deficiency cleared.
Construction/Loadline › Hull
Issued 26 June 2002 Resolved
All three aft deck scuttles ( 2ea f/o compt, 1 ea lazerette) are frozen & inoperable. Removed COI fm vsl until repairs are made.
Condition: Improper/Lack of Maintenance
Due 3 July 2002
Resolved 4 July 2002
Lifesaving
Issued 17 April 2000 Resolved
PROVIDE UPDATED PASSENGER SAFETY ORIENTATION PER 46 CFR 185.506.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Accommodation/Occupational Safety
Issued 17 April 2000 Resolved
PROVIDE UL STANDARD 217 SMOKE ALARM IN WAY OF THE PASSENGER ACCOMODATION SPACE.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Lifesaving
Issued 17 April 2000 Resolved
PROVIDE TWO (2) ADDITIONAL ADULT PFD'S. TOTAL PERSONS FOR COASTWISE ROUTE REDUCED TO 27 UNTIL COMPLETE.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Electrical
Issued 17 April 2000 Resolved
PROVIDE AC AND DC ELECTRICAL PLAN DRAWING PER 46CFR183.
Condition: Unknown
Due 5 July 2000
Resolved 5 July 2000
Documentation
Issued 17 April 2000 Resolved
COMPLETE PROVISIONS FOR A DRUG AUDIT: EMPLOYEE ASSISTANCE PROGRAM.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Documentation
Issued 19 May 1997 Resolved
USER FEE OF $670 NOT PAID FOR THE PERIOD 01MAY95 TO 30APR96.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Lifesaving
Issued 28 March 1995 Resolved
Renew ring buoys label with vessel's name.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Lifesaving
Issued 28 March 1995 Resolved
Repaint both life floats, label with capacity and vessel's name.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Construction/Loadline
Issued 28 March 1995 Resolved
Reattach captive line to vessel on aft deck hatch.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Engineering
Issued 28 March 1995 Resolved
Permanently attach sea strainer for generator.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Accommodation/Occupational Safety
Issued 1 December 1994 Resolved
Label forward escape hatch "Emergency Escape - Keep Clear".
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Engineering
Issued 1 December 1994 Resolved
Insulate 3 turbo chargers on the main engines.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Accommodation/Occupational Safety
Issued 1 December 1994 Resolved
Renew 2 cracked windows starboard side and aft.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Engineering
Issued 1 December 1994 Resolved
Renew 2 clamps on starboard log - aft.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Engineering
Issued 9 April 1992 Resolved
Repair port emergency fuel shutoff.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Construction/Loadline
Issued 16 May 1991 Resolved
INSTALL GASKET ON HATCH TO LAZARETTE PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 23 MAY 91.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Lifesaving
Issued 16 May 1991 Resolved
RENEW WEAK LINK FOR PORT LIFEFLOAT PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 23 MAY 91.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Lifesaving
Issued 16 May 1991 Resolved
RENEW LINES ATTACING WATERLIGHTS TO LIFEFLOATS (18 FEET EACH) PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 23 MAY 91.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Fire Fighting
Issued 2 May 1990 Resolved
PROVIDE B-II FIRE EXTINGUISHER FOR ACCOMMODATION SPACE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990 Resolved
PROVIDE 4' OARS FOR LIFEFLOATS. STENCIL WITH VESSEL'S NAME AND TIE TO FLOATS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Engineering
Issued 2 May 1990 Resolved
REPAIR REMOTE FUEL SHUTOFF (HANDLES).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Navigation
Issued 2 May 1990 Resolved
PROVIDE A SUITABLE HORN. PROVIDE PORTABLE AIR HORN UNTIL FIXED HORN IS REPAIRED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Electrical
Issued 2 May 1990 Resolved
PROVIDE A VOLTMETER AND AMMETER FOR THE GENERATOR IAW 46 CFR 183.10-5(G).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990 Resolved
PROVIDE 18' LINES FOR LIFEFLOAT WATERLIGHTS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990 Resolved
PROVIDE/REPAIR WATERLIGHTS FOR LIFEFLOATS (2) PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990 Resolved
RETIE LIFEFLOAT PENDANTS WITH NMT 2 TURNS OF LIGHT TWINE IAW 46 CFR 160.010-3(I).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Documentation
Issued 30 August 1989 Resolved
CREDIT DRYDOCK DUE 28FEB91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Engineering
Issued 30 August 1989 Resolved
INSTALL AND LABEL REMOTE FUEL TANK VALVE SHUTOFFS FOR BOTH PORT AND STAR- BOARD FUEL LINES PRIOR TO 30SEP89.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Fire Fighting
Issued 2 May 1989 Resolved
INSTALL FIRE EXTINGUISHER BRACKET IN FORWARD QUARTERS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989 Resolved
PROVIDE FLAME SCREEN ON STBD FUEL TANK VENT.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989 Resolved
SECURE 2 PADDLES IN EACH LIFE FLOAT. DO NOT USE TIE-WRAPS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989 Resolved
PROVIDE WATER LIGHT HOLDERS FOR FLOAT FREE FLOATS. DO NOT USE TIE-WRAPS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989 Resolved
INSTALL APPROVED HEAT SHIELDS ON 3 FUEL FILTERS WITH PLASTIC BOWLS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989 Resolved
INSTALL EMERGENCY SHUT-OFF VALVE, PORT FUEL TANK.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989 Resolved
STENCIL ACCESS TO EMERGENCY FUEL SHUT-OFF.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Deck/Cargo
Issued 2 May 1989 Resolved
SECURELY BRACKET PIPING FOR DECK WASH AND BAIT WELL PUMPS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989 Resolved
SECURE PAINTERS AND WEAKLINKS ON BOTH LIFE FLOATS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Documentation
Issued 2 May 1989 Resolved
PROVIDE FCC RADIO STATION AND RADIOTELEPHONE CERTIFICATES.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Accommodation/Occupational Safety
Issued 2 May 1989 Resolved
GLASS-IN GOOSENECK VENT IN FOREPEAK.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989 Resolved
PROVIDE LIGHTS FOR 5 ADULT PFD'S.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Electrical
Issued 2 May 1989 Resolved
PROVIDE BATTERY BOX AND COVER IN E/R STBD SIDE.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Electrical
Issued 2 May 1989 Resolved
PERMANENTLY WIRE 2 E/R FLOURESCENT LIGHTS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989 Resolved
DOUBLE CLAMP PORT FUEL TANK VENT HOSE.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Accommodation/Occupational Safety
Issued 2 May 1989 Resolved
REPAIR LOOSE HANDRAILS PORT BOW.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Documentation
Issued 19 October 1988 Resolved
MAINTAIN ORIGINAL CERTIFIATE OF DOCUMENTATION ON BOARD.
Condition: Unknown
Due 19 October 1988
Resolved 19 October 1988
Lifesaving
Issued 19 October 1988 Resolved
PROVIDE 1 ADULT PFD STENCILED WITH THE VESSEL'S NAME PRIOR TO CARRYING MORE THAN 47 PERSONS.
Condition: Unknown
Due 19 October 1988
Resolved 19 October 1988
Engineering
Issued 19 October 1988 Resolved
INSTALL FLAME SCREENS OF 30X30 MESH OF CORROSION RESISTANT METAL FOR FUEL OIL VENTS.
Condition: Unknown
Due 19 October 1988
Resolved 19 October 1988
Navigation
Issued 19 October 1988 Resolved
INSTALL AN 8" SHIP'S BELL.
Condition: Unknown
Due 19 October 1988
Resolved 19 October 1988
Lifesaving
Issued 9 February 1988 Resolved
PROVIDE 6 HAND ORANGE SMOKE DISTRESS SIGNALS PRIOR TO CARRYING PASSENGERS FOR HIRE BUT NOT LATER THAT 22MAR88.
Condition: Unknown
Due 9 February 1988
Resolved 9 February 1988
Engineering
Issued 10 November 1986 Resolved
INSTALL ONE ADDITIONAL BILGE PUMP IN THE FUELTANK COMPARTMENT FOR A TOTAL OF TWO
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Construction/Loadline
Issued 10 November 1986 Resolved
PROVIDE ADDITIONAL COMPARTMENT VENTILIATION FOR FUEL TANK COMPARTMENT
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Lifesaving
Issued 10 November 1986 Resolved
RENEW ALL DETERIORATED LINES ON BOTH LIFERAFTS USING DARK COLORED OR SUN RESISTANT TREATED LINE
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Engineering
Issued 10 November 1986 Resolved
REMOVE PLASTIC DISCHARGE TUBING FROM EACH BILGE PUMP AND INSTALL ALL RIGID PIPING FROM THE PUMPS TO OVERBOARD DISCHARGE.
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Engineering
Issued 10 November 1986 Resolved
INSTALL A CHECK VALVE IN EACH BILGE PUMP DISCHARGE LINE.
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Engineering
Issued 10 November 1986 Resolved
RENEW FUEL VENT FLAME SCREENS
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Construction/Loadline
Issued 7 November 1985 Resolved
PROVIDE 288 SQUARE INCHES OF ADDITIONAL FREEING PORT. -VIEI
Condition: Unknown
Due 7 November 1985
Resolved 7 November 1985
Documentation
Issued 7 November 1985 Resolved
PROVIDE AN FCC RADIO TELEPHONE CERTIFICATE.
Condition: Unknown
Due 7 November 1985
Resolved 7 November 1985
Documentation
Issued 7 November 1985 Resolved
CHANGE NAME ON FCC STATION LICENSE TO BE LISA VICE LISA II.
Condition: Unknown
Due 7 November 1985
Resolved 7 November 1985
Electrical
Issued 7 November 1985 Resolved
SUBMIT A WIRING DIAGRAM OF ALL WIRING TO MSO MOBILE FOR APPROVAL, FOR THE VESSEL AS BUILT.
Condition: Unknown
Due 7 November 1985
Resolved 7 November 1985
Construction/Loadline
Issued 7 November 1985 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 7 November 1985
Resolved 7 November 1985

Ownership record