Records from 1985 to 2026. Most recent: inspection, 8 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 82
8 April 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8344766
6 April 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8333936
16 April 2025
COI Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8105122
9 October 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8016709
15 May 2024
COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7912728
29 November 2023
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7831266
23 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7812952
8 June 2023
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7703572
21 October 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7337213
15 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7226049
14 June 2020
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6980988
8 November 2019
In-Service Inspection · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6851987
29 April 2019
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6672678
8 April 2019
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6656367
17 December 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6598746
28 July 2018
Type not recorded
No type recorded · Station Chatham · USCG Northeast District (CGD-NE) · Activity 6493856
16 May 2018
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6416710
9 May 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6400520
13 October 2017
Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6287041
18 May 2017
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6152703
18 May 2017
In-Service Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6177739
12 December 2016
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6056629
22 December 2015
Deficiency Check · Internal Structural Exam · In-Service Inspection · Hull Examination · Drydock Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5785939
9 November 2015
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5763117
15 September 2011
Administrative Inspection · Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4146176
31 May 2007
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2990390
9 May 2006
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2644437
3 February 2005
Hull Examination · COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2285475
12 May 2004
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2065091
4 February 2003
Plan Review "T" Boat · Re-Inspection · Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1739623
3 July 2002
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1638126
17 July 2001
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1373549
19 January 2001
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1412226
17 April 2000
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1395444
26 August 1999
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1115749
3 August 1999
Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1408351
7 May 1999
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1411913
15 January 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1416836
24 June 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 727513
15 May 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 82434
29 April 1998
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1430574
8 December 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 668730
19 May 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1383739
19 May 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1461818
2 January 1997
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1427307
4 December 1996
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1447658
23 April 1996
Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1445083
20 June 1995
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 877530
28 March 1995
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 854422
1 December 1994
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 839785
13 June 1994
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1330956
4 April 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 668728
14 March 1994
Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 668729
31 January 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 98035
6 May 1993
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 834331
24 February 1993
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1143595
13 July 1992
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1268335
9 April 1992
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1262373
16 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1252252
18 July 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1308448
16 May 1991
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1244611
28 February 1991
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 900813
28 February 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 945388
27 June 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1228513
23 May 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1224866
2 May 1990
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 915477
22 November 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1236932
30 August 1989
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 892575
14 August 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1038532
15 June 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1203750
19 May 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 886678
2 May 1989
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1350178
7 February 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1040218
17 November 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1204297
17 November 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1208729
19 October 1988
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1199961
11 April 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1341533
9 February 1988
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1025301
9 December 1986
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1023860
10 November 1986
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1322921
21 April 1986
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1306290
7 November 1985
Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 990029
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 April 2025
Resolved
Employees must be enrolled in chemical testing program. Provide proof of enrollment prior to pax.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2025
Resolution: Vessel sent an email with a photo of the enrollment ald all was in full compliance.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2025
Resolved
Battery Charger must be equipped with Amp Meter within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2025
Resolved 18 August 2025
Resolution: Vessel sent an email showing the amp meter and the battery charger.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 April 2025
Resolved
Main Engines must have machinery guards around the belts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2025
Resolved 18 August 2025
Resolution: Vessel sent an email with pictures showing the newly installed guards.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 May 2024
Resolved
Update EPIRB registration with new call sign. 46CFR180.64
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2024
Resolution: Received photos
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2024
Resolved
Port engine has a pinhole leak in the cooling water discharge line. Replace section of wasted piping. 46CFR182.700
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2024
Resolution: eceived photo
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 May 2024
Resolved
Each Buoyant Apparatus must be fitted with a lifeline, pennants, a painter and a light. Replace wasted light painter on buoyant apparatus and add lights to buoyant apparatus's without lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2024
Resolution: Received Photo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 May 2024
Resolved
An adult life Jacket shal be provided for all passengers listed on the COI. Three Jim Bouy life jackets were destroyed during the COI inspection. Vessel passenger count is limited to 44 total person until the 3 life jackets are replaced. 46CFR180.71(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2024
Resolution: Received photo
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 May 2024
Resolved
The collision bulkhead is a watertight bulkhead. The collision bulkhead has two penetrations for hydraulic hoses that are not watertight. Make penetrations watertight. 46CFR178.310(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2024
Resolution: Received photo
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 May 2024
Resolved
Vessel is required to carry day shapes in accordance with NAVRULES Part C. Provide day shapes for lighting arrangements available on the vessel's mast.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2024
Resolution: Received photo
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 October 2023
Resolved
Vessel is required to complete a Hull/ISE prior to 31OCT23 as noted on the vessel's COI. Vessel owner can not secure a shipyard to haul and block the vessel until after the 31Oct23 deadline. Vessel is not allowed to carry passengers until the vessel is hauled and inspected by a Coast Guard marine inspector for credit dry dock. 46CFR176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2023
Resolution: Completed Hull/ISE
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2019
Resolved
Shaft and cutlass bearings need to be repaired and or replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2019
Resolved 25 November 2019
Resolution: Shaft has been re-aligned and cutlass bearings replaced.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 April 2019
Resolved
FWD hatch IWO deck, wood rot was found. Remove or replace in-kind. Vessel Rep shall repair or replace by credit dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2019
Resolved 27 September 2019
Resolution: This has been repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2019
Resolved
Aft steering, port side rudder post is leaking water.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2019
Resolved 29 April 2019
Resolution: Rudder post tighted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 April 2019
Resolved
STBD fuel line is wasted IWO fuel tank supply line. Replace Fuel hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2019
Resolved 29 April 2019
Resolution: Fuel pipe replaced.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 April 2019
Resolved
FWD htach is leaking. Replace gasket.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2019
Resolved 29 April 2019
Resolution: New gasket material installed.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 17 December 2018
Resolved
Replace all survival crafts.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2019
Resolved 8 April 2019
Resolution: Vessel properly installed 04 new lifefloats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 December 2018
Resolved
Replace life ring IWO of pilot house.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2019
Resolved 8 April 2019
Resolution: Vessel installed new life ring with waterlight near the pilot house.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 December 2018
Resolved
Conduct drill PTCP.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2019
Resolved 29 April 2019
Resolution: Vessel conducted drills.
Lifesaving › Lifefloat › Float Free
Issued 9 May 2018
Resolved
Life floats on vessel are not properly rigged for float free arrangement. Rerigg the lines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2018
Resolved 16 May 2018
Resolution: Vessel properly rigged the lifefloats to allow for float free operation.
Lifesaving › Lifefloat › Lifeline
Issued 9 May 2018
Resolved
Vessel's lifefloats lifelines were found broken. Repair or replace with a repair kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2018
Resolved 16 May 2018
Resolution: Vessel replaced its 10 person lifefloat with a better condition 12 person lifefloat.
Lifesaving › Lifefloat › Paddle
Issued 9 May 2018
Resolved
Restencil life float paddles with vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2018
Resolved 16 May 2018
Resolution: Vessel restenciled vessel's name on all paddles for the lifefloats.
Lifesaving › Lifefloat › Float Free
Issued 12 December 2016
Resolved
Lifefloats are not properly separated with wood, etc. Space the lifefloats so they will not stick together.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 18 May 2017
Resolution: All life floats are correctly separated and secured.
Lifesaving › Lifefloat › Serviceable
Issued 12 December 2016
Resolved
Lifefloats are slightly wasted and the foam insulation is showing. Repair with an approved repair kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 18 May 2017
Resolution: Vessel rep repaired life floats with approved repair kit.
Lifesaving › Lifefloat › Retroreflective Material
Issued 12 December 2016
Resolved
Lifefloats are missing reflective tape. Provide new reflective material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 18 May 2017
Resolution: Reflective tape has been installed.
Communications › Radio Communications › EPIRB
Issued 12 December 2016
Resolved
The EPIRB hydrostatic release date is not scratched out. Scratch out dates to show date of expiration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 18 May 2017
Resolution: Epirb has been checked for proper labeling.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 12 December 2016
Resolved
Vessel was unable to complete a man overboard drill and fire drill. Vessel will need to complete drills prior to taking passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2016
Resolved 18 May 2017
Resolution: Wintessed satisfactory drills
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 December 2016
Resolved
Vessel's bilge alarms are missing labels on the vessel's operating station. Provide missing labels to distiguish which alarm is where.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 18 May 2017
Resolution: Vessel bilge lables have been installed.
Deck/Cargo › Towing › Chocks
Issued 22 December 2015
Resolved
FWD Bit has large crack down center of bit. Repair or replace bit in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2015
Resolved 9 June 2016
Resolution: Captain contacted MSD to inform unit that the fwd bit had been repaired.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 22 December 2015
Resolved
Halon system needs to be serviced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2016
Resolved 10 May 2016
Resolution: Halon system has been serviced by local fire company.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 December 2015
Resolved
repair life float lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2016
Resolved 10 May 2016
Resolution: Life float light has been repaired.
Communications › Radio Communications › EPIRB
Issued 9 November 2015
Resolved
AVH01: Replace hydro release for EPIRB.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2015
Resolved 22 December 2015
Resolution: Replaced hydro release.
Communications › Radio Communications › EPIRB
Issued 9 November 2015
Resolved
AVH02: Update EPIRB Registration.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2015
Resolved 22 December 2015
Resolution: Updated epirb registration.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 9 November 2015
Resolved
AVH03: Service Halon system for engineroom.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2015
Resolved 9 June 2016
Resolution: Halon was serviced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 November 2015
Resolved
AVH04: Replace life float lights (2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2015
Resolved 9 June 2016
Resolution: Light has been fixed.
Deck/Cargo › Holds/Tanks › Hatch
Issued 9 November 2015
Resolved
AVH05: Port & Stbd hatch cover securring chains need to be replaced
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2015
Resolution: Replaced the securing chains for the hatch covers.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 9 November 2015
Resolved
AVH06: Service all bilge pumps.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2015
Resolution: Serviced one and replaced the other bilge pump, all sat.
Engineering › Fuel Oil Service System › Valve
Issued 9 November 2015
Resolved
AVH07: Lable all F/O cutoff for MDE's.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2015
Resolution: Labeled the F/O cutoff.
Engineering › Fuel Oil Service System › Valve
Issued 9 November 2015
Resolved
AVH08: Repair F/o handle in aft compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2015
Resolution: Replaced F/O cutoff handle.
Fire Fighting › Fire Main › Material
Issued 9 November 2015
Resolved
AVH09: Fire pump has a non-approved hose, replace hose with approved hose.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2015
Resolution: Replaced hose with approved type.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Block
Issued 9 November 2015
Resolved
AVH10: SSDG engine mounts need to be secured properly.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2015
Resolution: Properly secured SSDG mounts.
Stability › Watertight Integrity › General
Issued 15 September 2011
Resolved
Hatch on focsle is not watertight. Properly repair hatch to make watertight.
Action required: 705 - Other - as specified
Due 30 April 2012
Resolved 23 March 2012
Resolution: Received photo and email from owner regarding the repair of the hatch on the focsle. Deficiency cleared.
Engineering › Bilge Water Management System › Valve
Issued 15 September 2011
Resolved
Install positive action valve on stbd ovbd discharge for electric sump pump.
Action required: 705 - Other - as specified
Due 30 April 2012
Resolved 12 March 2012
Resolution: Positive action valve installed. Deficiency cleared.
Construction/Loadline › Hull
Issued 26 June 2002
Resolved
All three aft deck scuttles ( 2ea f/o compt, 1 ea lazerette) are frozen & inoperable. Removed COI fm vsl until repairs are made.
Condition: Improper/Lack of Maintenance
Due 3 July 2002
Resolved 4 July 2002
Lifesaving
Issued 17 April 2000
Resolved
PROVIDE UPDATED PASSENGER SAFETY ORIENTATION PER 46 CFR 185.506.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Accommodation/Occupational Safety
Issued 17 April 2000
Resolved
PROVIDE UL STANDARD 217 SMOKE ALARM IN WAY OF THE PASSENGER ACCOMODATION SPACE.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Lifesaving
Issued 17 April 2000
Resolved
PROVIDE TWO (2) ADDITIONAL ADULT PFD'S. TOTAL PERSONS FOR COASTWISE ROUTE REDUCED TO 27 UNTIL COMPLETE.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Electrical
Issued 17 April 2000
Resolved
PROVIDE AC AND DC ELECTRICAL PLAN DRAWING PER 46CFR183.
Condition: Unknown
Due 5 July 2000
Resolved 5 July 2000
Documentation
Issued 17 April 2000
Resolved
COMPLETE PROVISIONS FOR A DRUG AUDIT: EMPLOYEE ASSISTANCE PROGRAM.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Documentation
Issued 19 May 1997
Resolved
USER FEE OF $670 NOT PAID FOR THE PERIOD 01MAY95 TO 30APR96.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Lifesaving
Issued 28 March 1995
Resolved
Renew ring buoys label with vessel's name.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Lifesaving
Issued 28 March 1995
Resolved
Repaint both life floats, label with capacity and vessel's name.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Construction/Loadline
Issued 28 March 1995
Resolved
Reattach captive line to vessel on aft deck hatch.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Engineering
Issued 28 March 1995
Resolved
Permanently attach sea strainer for generator.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Accommodation/Occupational Safety
Issued 1 December 1994
Resolved
Label forward escape hatch "Emergency Escape - Keep Clear".
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Engineering
Issued 1 December 1994
Resolved
Insulate 3 turbo chargers on the main engines.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Accommodation/Occupational Safety
Issued 1 December 1994
Resolved
Renew 2 cracked windows starboard side and aft.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Engineering
Issued 1 December 1994
Resolved
Renew 2 clamps on starboard log - aft.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Engineering
Issued 9 April 1992
Resolved
Repair port emergency fuel shutoff.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Construction/Loadline
Issued 16 May 1991
Resolved
INSTALL GASKET ON HATCH TO LAZARETTE PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 23 MAY 91.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Lifesaving
Issued 16 May 1991
Resolved
RENEW WEAK LINK FOR PORT LIFEFLOAT PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 23 MAY 91.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Lifesaving
Issued 16 May 1991
Resolved
RENEW LINES ATTACING WATERLIGHTS TO LIFEFLOATS (18 FEET EACH) PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 23 MAY 91.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Fire Fighting
Issued 2 May 1990
Resolved
PROVIDE B-II FIRE EXTINGUISHER FOR ACCOMMODATION SPACE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990
Resolved
PROVIDE 4' OARS FOR LIFEFLOATS. STENCIL WITH VESSEL'S NAME AND TIE TO FLOATS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Engineering
Issued 2 May 1990
Resolved
REPAIR REMOTE FUEL SHUTOFF (HANDLES).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Navigation
Issued 2 May 1990
Resolved
PROVIDE A SUITABLE HORN. PROVIDE PORTABLE AIR HORN UNTIL FIXED HORN IS REPAIRED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Electrical
Issued 2 May 1990
Resolved
PROVIDE A VOLTMETER AND AMMETER FOR THE GENERATOR IAW 46 CFR 183.10-5(G).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990
Resolved
PROVIDE 18' LINES FOR LIFEFLOAT WATERLIGHTS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990
Resolved
PROVIDE/REPAIR WATERLIGHTS FOR LIFEFLOATS (2) PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990
Resolved
RETIE LIFEFLOAT PENDANTS WITH NMT 2 TURNS OF LIGHT TWINE IAW 46 CFR 160.010-3(I).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Documentation
Issued 30 August 1989
Resolved
CREDIT DRYDOCK DUE 28FEB91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Engineering
Issued 30 August 1989
Resolved
INSTALL AND LABEL REMOTE FUEL TANK VALVE SHUTOFFS FOR BOTH PORT AND STAR- BOARD FUEL LINES PRIOR TO 30SEP89.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Fire Fighting
Issued 2 May 1989
Resolved
INSTALL FIRE EXTINGUISHER BRACKET IN FORWARD QUARTERS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989
Resolved
PROVIDE FLAME SCREEN ON STBD FUEL TANK VENT.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989
Resolved
SECURE 2 PADDLES IN EACH LIFE FLOAT. DO NOT USE TIE-WRAPS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989
Resolved
PROVIDE WATER LIGHT HOLDERS FOR FLOAT FREE FLOATS. DO NOT USE TIE-WRAPS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989
Resolved
INSTALL APPROVED HEAT SHIELDS ON 3 FUEL FILTERS WITH PLASTIC BOWLS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989
Resolved
INSTALL EMERGENCY SHUT-OFF VALVE, PORT FUEL TANK.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989
Resolved
STENCIL ACCESS TO EMERGENCY FUEL SHUT-OFF.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Deck/Cargo
Issued 2 May 1989
Resolved
SECURELY BRACKET PIPING FOR DECK WASH AND BAIT WELL PUMPS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989
Resolved
SECURE PAINTERS AND WEAKLINKS ON BOTH LIFE FLOATS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Documentation
Issued 2 May 1989
Resolved
PROVIDE FCC RADIO STATION AND RADIOTELEPHONE CERTIFICATES.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Accommodation/Occupational Safety
Issued 2 May 1989
Resolved
GLASS-IN GOOSENECK VENT IN FOREPEAK.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989
Resolved
PROVIDE LIGHTS FOR 5 ADULT PFD'S.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Electrical
Issued 2 May 1989
Resolved
PROVIDE BATTERY BOX AND COVER IN E/R STBD SIDE.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Electrical
Issued 2 May 1989
Resolved
PERMANENTLY WIRE 2 E/R FLOURESCENT LIGHTS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989
Resolved
DOUBLE CLAMP PORT FUEL TANK VENT HOSE.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Accommodation/Occupational Safety
Issued 2 May 1989
Resolved
REPAIR LOOSE HANDRAILS PORT BOW.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Documentation
Issued 19 October 1988
Resolved
MAINTAIN ORIGINAL CERTIFIATE OF DOCUMENTATION ON BOARD.
Condition: Unknown
Due 19 October 1988
Resolved 19 October 1988
Lifesaving
Issued 19 October 1988
Resolved
PROVIDE 1 ADULT PFD STENCILED WITH THE VESSEL'S NAME PRIOR TO CARRYING MORE THAN 47 PERSONS.
Condition: Unknown
Due 19 October 1988
Resolved 19 October 1988
Engineering
Issued 19 October 1988
Resolved
INSTALL FLAME SCREENS OF 30X30 MESH OF CORROSION RESISTANT METAL FOR FUEL OIL VENTS.
Condition: Unknown
Due 19 October 1988
Resolved 19 October 1988
Navigation
Issued 19 October 1988
Resolved
INSTALL AN 8" SHIP'S BELL.
Condition: Unknown
Due 19 October 1988
Resolved 19 October 1988
Lifesaving
Issued 9 February 1988
Resolved
PROVIDE 6 HAND ORANGE SMOKE DISTRESS SIGNALS PRIOR TO CARRYING PASSENGERS FOR HIRE BUT NOT LATER THAT 22MAR88.
Condition: Unknown
Due 9 February 1988
Resolved 9 February 1988
Engineering
Issued 10 November 1986
Resolved
INSTALL ONE ADDITIONAL BILGE PUMP IN THE FUELTANK COMPARTMENT FOR A TOTAL OF TWO
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Construction/Loadline
Issued 10 November 1986
Resolved
PROVIDE ADDITIONAL COMPARTMENT VENTILIATION FOR FUEL TANK COMPARTMENT
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Lifesaving
Issued 10 November 1986
Resolved
RENEW ALL DETERIORATED LINES ON BOTH LIFERAFTS USING DARK COLORED OR SUN RESISTANT TREATED LINE
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Engineering
Issued 10 November 1986
Resolved
REMOVE PLASTIC DISCHARGE TUBING FROM EACH BILGE PUMP AND INSTALL ALL RIGID PIPING FROM THE PUMPS TO OVERBOARD DISCHARGE.
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Engineering
Issued 10 November 1986
Resolved
INSTALL A CHECK VALVE IN EACH BILGE PUMP DISCHARGE LINE.
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Engineering
Issued 10 November 1986
Resolved
RENEW FUEL VENT FLAME SCREENS
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Construction/Loadline
Issued 7 November 1985
Resolved
PROVIDE 288 SQUARE INCHES OF ADDITIONAL FREEING PORT. -VIEI
Condition: Unknown
Due 7 November 1985
Resolved 7 November 1985
Documentation
Issued 7 November 1985
Resolved
PROVIDE AN FCC RADIO TELEPHONE CERTIFICATE.
Condition: Unknown
Due 7 November 1985
Resolved 7 November 1985
Documentation
Issued 7 November 1985
Resolved
CHANGE NAME ON FCC STATION LICENSE TO BE LISA VICE LISA II.
Condition: Unknown
Due 7 November 1985
Resolved 7 November 1985
Electrical
Issued 7 November 1985
Resolved
SUBMIT A WIRING DIAGRAM OF ALL WIRING TO MSO MOBILE FOR APPROVAL, FOR THE VESSEL AS BUILT.
Condition: Unknown
Due 7 November 1985
Resolved 7 November 1985
Construction/Loadline
Issued 7 November 1985
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 7 November 1985
Resolved 7 November 1985