MOMENTUM

MOMENTUM is a 1964 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 1985, most recently in March 2025, along with 24 deficiencies.

Records from 1985 to 2025. Most recent: inspection, 7 March 2025.

Built
1964
Last inspected
7 March 2025
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA5740
251137
Flag
UNITED STATES
366823330 (licence lapsed)
Maury page id
psix-251137

Inspections, by type

…with no type recorded3
Years with a record 21 calendar years (1985–2025)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)30.6 ft × 9.5 ft × 7.1 ft
Registered tonnagegross 10 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLASH BROS BOATYARD INC · FRIENDSHIP, ME, UNITED STATES · built 1964
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portERIE, PA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDA5740MMSI 366823330 · expired · compulsorily equipped · granted 18 August 2001, cancelled 22 October 2011
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 34

7 March 2025 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8090215
15 December 2011 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4209366
19 May 2008 Deficiency Check · Re-Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3211562
15 May 2007 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3084449
12 October 2005 Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2513476
2 May 2005 Administrative Inspection · Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2417591
18 November 2004 Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2292405
18 August 2004 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2171453
25 August 2003 Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1880970
23 May 2003 Administrative Inspection
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1799789
29 August 2002 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1668367
1 August 2001 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1462251
13 June 2000 COI Inspection · Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1389111
5 September 1997 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1121767
15 July 1996 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1170017
8 July 1996 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1092970
20 June 1996 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1077924
30 May 1995 Re-Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 874277
24 February 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1160774
19 December 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1152390
15 July 1994 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1137911
20 June 1994 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1138070
1 July 1991 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 933621
25 June 1991 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1222814
16 July 1990 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1218477
3 July 1989 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1338178
25 May 1989 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 891451
18 April 1989 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1346553
27 May 1988 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1197968
1 July 1987 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1318473
8 May 1987 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1020772
1 December 1986 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1329522
21 July 1986 Initial Certification
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1007952
9 October 1985 Credit Drydock
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1008409

Deficiency record · 24

Stability › Incline Test › General
Issued 22 December 2011 Resolved
No Certificate of compliance from O/O with regard to New AAWPP compliance. Provide proof of stability and compliance. Passenger capacity reduced to 10 paersons until proof is provided.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 July 2012
Resolved 7 March 2025
Resolution: Vsl is inactive; if vsl enters back into service will be required to complete new stability test with updated AAWPP.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 19 May 2008 Resolved
During the test of the fixed firefighting system by the contracted (The Fireline Group) organization, there was a problem with soleniod shutdown operating properly. Informed o/o of the vessel that we would require a copy of proof of proper operation from the fire company prior to taking passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2008
Resolution: Sector Buffalo office received faxed memo from The Fireline Group attesting that the solenoid shutdown issue was resolved, retested, and found to be in good working order.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 May 2005 Resolved
Provide on board original certificate of documentation.
Action required: 705 - Other - as specified
Due 13 July 2005
Resolved 4 August 2005
Resolution: Receipt of fax submission of CG-1258 from operator, requesting copy of original upon recipt.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 May 2005 Resolved
Provide servicing report to this office prior to commercial operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2005
Resolved 5 August 2005
Resolution: Received service report. Conducted by The Fireline Group. Sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2005 Resolved
Remove wire nuts and properly connect electrical wires IWO port engine bulkhead.
Action required: 705 - Other - as specified
Due 31 August 2005
Resolved 12 October 2005
Resolution: Attended vessel, witnessing satisfactory correction of issued requirement.
Fire Fighting › Ventilation Systems › Ducts
Issued 2 May 2005 Resolved
Replace vent pipe for engine space.
Action required: 705 - Other - as specified
Due 31 August 2005
Resolved 12 October 2005
Resolution: Attended vessel, witnessing satisfactory correction of issued requirement.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 May 2005 Resolved
Replace water light. Vessel is limited to daytime operation however installed and cracked body.
Due 3 August 2005
Resolved 12 October 2005
Resolution: Attended vessel, witnessing satisfactory correction of issued requirement.
Engineering › Steering Gear System › Rudder
Issued 18 November 2004 Resolved
Replace rudder, prior to vessels return to water CGMI must be given opportunity to visually inspect arrangement.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 2 May 2005
Resolution: Attended vessel finding rudder satisfactorily rebuilt and fastened.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 18 August 2004 Resolved
Provide documentation attesting that all Supervisors have completed required EAP training.
Action required: 705 - Other - as specified
Due 17 September 2004
Resolved 3 August 2005
Resolution: Tape available with training entry made attesting that all required pers have received required training.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 18 August 2004 Resolved
Replace reflective material on 5 life jackets identified during inspection.
Action required: 705 - Other - as specified
Due 25 August 2004
Resolved 18 November 2004
Resolution: Jackets identified for RIN inspected and found with new retro attached.
Engineering › Bilge Water Management System › Not Operational
Issued 18 August 2004 Resolved
Prove proper operation of bilge high water audible and visual alarm indication.
Action required: 705 - Other - as specified
Due 25 August 2004
Resolved 18 November 2004
Resolution: New sw installed with satisfactory op test witnessed.
Engineering › Freshwater System (cylinder head cooling) › Valve
Issued 18 August 2004 Resolved
Prove proper operation of through hull valves (x3).
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 August 2004
Resolved 19 August 2004
Resolution: Post maintenance valves operation satisfactory.
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 August 2004 Resolved
Provide battery box cover for port installation.
Action required: 705 - Other - as specified
Due 25 August 2004
Resolved 18 November 2004
Resolution: New box installed with strap.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 18 August 2004 Resolved
Install 30x30 mesh screen for fuel oil tank vent.
Action required: 705 - Other - as specified
Due 25 August 2004
Resolved 18 November 2004
Resolution: New screen installed and view this date.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 August 2004 Resolved
Provide original on board vessel.
Due 25 August 2004
Resolved 25 August 2004
Electrical
Issued 1 August 2001 Resolved
PROVIDE OVERCURRENT PROTECTION DEVICE FOR ELECTRICAL POWER.
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Documentation
Issued 13 June 2000 Resolved
Provide drawings for the vessels structural arrangement/fixed fire suppression system/ and high water bilge alarm system.
Condition: Unknown
Due 19 June 2000
Resolved 19 June 2000
Engineering
Issued 13 June 2000 Resolved
Provide oil pressure guage and high jacket water temperature guage in accordance with 46 CFR 182.410(b).
Condition: Unknown
Due 19 June 2000
Resolved 19 June 2000
Documentation
Issued 30 May 1995 Resolved
Obtain and post a copy of the vessel's stability letter.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Lifesaving
Issued 30 May 1995 Resolved
Provide six red visual distress signals.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Construction/Loadline
Issued 25 May 1989 Resolved
IN ACCORDANCE WITH 46 CFR 171.124 PROVIDE SECURING DEVICE AND HINGE ON RETAINING DEVICE FOR LAZARETTE HATCH COVER.
Condition: Unknown
Due 25 May 1989
Resolved 25 May 1989
Construction/Loadline
Issued 25 May 1989 Resolved
IN ACCORDANCE WITH RULE 25 OF THE INTERNATIONAL NAVIGATION RULES REPAIR PORT RUNNING LIGHT PRIOR TO OPERATION.
Condition: Unknown
Due 25 May 1989
Resolved 25 May 1989
Navigation
Issued 25 May 1989 Resolved
IN ACCORDANCE WITH RULE 30 OF THE NAVIGATION RULES PROVIDE AN ANCHOR LIGHT.
Condition: Unknown
Due 25 May 1989
Resolved 25 May 1989
Fire Fighting
Issued 25 May 1989 Resolved
IN ACCORDANCE WITH 46 CFR 181.30-5 PROVIDE TWO (02) COAST GUARD APPROVED ULLISTED FOR MARINE USE. B-II EXTINGUISHERS AND B-I EXTINGUISHER PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 25 May 1989
Resolved 25 May 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.