SUN
Freight Ship · Bulk Carrier class · Built 1980s · USCG Northwest District (CGD-NW) · Other hulls named SUN
SUN is a 1983 freight ship. The Coast Guard has recorded 28 inspections since 1986, most recently in September 2010, along with 16 deficiencies and 3 operational controls.
Records from 1986 to 2010. Most recent: inspection, 13 September 2010.
- Built
- 1983
- Last inspected
- 13 September 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 16 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8220163 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HRI6
251148
Flag
LIBERIA
—
Maury page id
psix-251148
Inspections, by type
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it77481 - Displacement, Ton
66894 - Dead Weight, Ton
21783 - Convention (Subpart B), Net Ton
36526 - Convention (Subpart B), Gross Ton
66894 - Dead Weight, Ton
21783 - Convention (Subpart B), Net Ton
36526 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 28
13 September 2010
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3834120
11 February 2008
Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3143090
27 May 2006
Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2653666
11 February 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2291135
27 January 2005
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2281696
22 June 2004
PII Safety Exam · ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2107108
4 March 2004
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2018319
9 July 2002
Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1643508
1 March 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1606189
27 February 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1490031
20 February 2002
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1488147
12 February 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1487488
23 August 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 292818
27 June 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 291210
3 August 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 280526
30 September 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 433153
5 February 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 425120
28 April 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 402927
14 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 394308
9 April 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 390240
26 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 380071
20 April 1994
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 366261
7 December 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 532831
7 November 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 512671
18 February 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 348891
25 April 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 343326
20 January 1988
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 320800
8 February 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 306939
Deficiency record · 16
Lifesaving › Lifeboat › Propulsion Engine
Issued 27 May 2006
Resolved
Currently Starboard Lifeboat motor is being replaced. Prove proper operation of motor and provide service report to
CG Office. Repair/replacement to be approved to the satisfaction of Class. SOLAS 74/III.9
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 4 March 2004
Resolved
Sewage treatment plant pipe had soft patch and pin holes leaks. One of the air compressor is missing and the other air compressor is making a chattering noise. Make permanent repairs to the satisfaction of the U.S. Coast Guard.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 4 March 2004
Resolved
Main engine number 4 cylinder cooling water discharge pipe coupling has a soft patch. LEGACY COMPONENT DESC: Cylinder
Engineering › Freshwater System (injector cooling)
Issued 4 March 2004
Resolved
Main engine number 2 cylinder has a minor cooling water leak. LEGACY COMPONENT DESC: Minor Leak
Engineering › Freshwater System (jacketwater cooling)
Issued 4 March 2004
Resolved
Reduction gear cooler end bell has a temporary repair. LEGACY COMPONENT DESC: heat exchanger
Pollution Prevention/Response › Prevention Equipment
Issued 4 March 2004
Resolved
The OWS has been altered from original design. Current arrangement could allow the 15 ppm monitor to be bypassed. Return OWS to the original design and have Class verify proper operation. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Lifesaving
Issued 23 August 2001
Resolved
Port and stbd. lifeboat: Lifeboat capacity plate states 28 persons, safetyequipment states 36 (Lifeboats have 36 painted on sides) VSL has 28 crew (1) additional person total 2. Class to address lifeboat capacity plate/safety equipment certificate. Provide USCG with class report.
Deck/Cargo
Issued 27 June 2001
Resolved
Make repairs to hole in air compressor OVBD cooling line in ENG room to satisfactory of class._x001C_ _x001C_ SOLAS 74 (a) I/II
Accommodation/Occupational Safety
Issued 27 June 2001
Resolved
Replace holed cross over cooling pipe from firemain to aux machinery room._x001C__x001C_ SOLAS 74 (a)I/II
Engineering
Issued 27 June 2001
Resolved
Make repairs to leaking main engine cooling line._x001C_ _x001C_ SOLAS 74 (a)I/II
Engineering
Issued 5 February 1999
Resolved
PROVIDE PROPER HEAT REDUCING INSULATION AROUND #1 DIESEL GENERATOR EXHAUST LINE. SOLAS 74(unamended) I/11.
Navigation
Issued 5 February 1999
Resolved
REPAIR SPORADIC LEAK OF HYDRAULIC OIL FOR #1 STEERING PUMP. SOLAS 74(AMENDED) II-1/29.2.1
Engineering
Issued 5 February 1999
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR 15 PPM ALARM AND AUTOMATIC STOPPING DEVICE. OVERBOARD DISCHARGE VALVE TO REMAIN CLOSED AND ANY MACHINERY BILGES TO BE IMMEDIATELY TRANSFERRED TO BILGE HOLDING TANKS. ALSOPROVIDE PROOF OF USCG APPROVAL FOR OILY WATER SEPARATOR. MARPOL 73/78 I/16
Fire Fighting
Issued 5 February 1999
Resolved
PROVIDE CLASS SOCIETY APPROVAL SHOWING THAT FOAM AGENT STORAGE TANK PROVIDES SUFICIENT EXTINGUISHING AGENT TO PRODUCE A VOLUME OF FOAM EQUAL TOFIVE TIMES THE VOLUME OF THE LARGEST SPACE TO BE PROTECTED. SOLAS 74(AMENDED) II-2/9(a).
Navigation
Issued 5 February 1999
Resolved
REARRANGE LINKING BOLTS FOR STEERING GEAR RODS TO PREVENT POSSIBILITY OF BOLTS FALLING OUT UNDER VIBRATION FROM STEERING GEAR MACHINERY. SOLAS 74(AMENDED) V/19.2(b)(ii).
Navigation
Issued 20 January 1988
Resolved
A VIO OF 33CFR164.30 IN THAT THE VSL DID NOT HAVE O/B USCG LIGHT LIST,1988,VOL.1 OR ITS FOREIGN EQUIV,WHICH WAS REQ FOR THE VSL'S ROUTE FROM CAPE HENLOPEN TO FAIRLESS HILLS,PA.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.