Documentation record
Registered dimensions (L × B × D)50.0 ft × 15.0 ft × 5.0 ft
Registered tonnagegross 26 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderT D VINETTE COMPANY · ESCANABA, MI, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSEATTLE, WA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 24 April 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Simplified, Gross Ton
21 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 16 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 16
9 February 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8299544
13 February 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8075806
15 February 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7868109
8 February 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7862803
21 February 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7640467
22 February 2022
COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7398567
5 February 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7136075
4 June 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6962029
13 June 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6713308
21 February 2019
Administrative Inspection · Examination of Repairs · Drydock Exam · Damage Survey · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6629979
29 September 2018
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6552813
27 March 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6379499
12 September 2017
Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6267259
16 March 2017
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6096988
24 February 2017
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6094409
24 May 2016
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5885320
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 February 2026
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years...If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate.
Vessel missing a valid FCC Safety Radiotelephony Certificate.
47 CFR 80.903
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2026
Resolved 13 February 2026
Resolution: Owner/operator provided current copy of Radio Telephony Certificate. See certificates.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 February 2025
Resolved
The power fire pump shall be selfpriming and of such size as to discharge an effective stream from a hose connected to the highest outlet. Vessel's fire pump lines were frozen and preventing discharge.
46 CFR 181.10-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2025
Resolved 3 March 2025
Resolution: O/o was unable to repair fire pump and resorted to meeting applicable new T requirements- fire buckets. Discussed the need to update emergency instructions to reflect the inoperational status of fire pump and use of fire buckets instead.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 February 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel has 43 out of 45 serviceable life jackets on board.
46 CFR 184.420(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2025
Resolved 3 March 2025
Resolution: O/o brought into service two PFDs, meeting the total required per the COI.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 February 2025
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire... The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Records of drills do not provide information that allow for tracking of members involved and therefore ensuring that each crew member is receiving adequate training. Records also do not provide details of scenario and training topics.
46 CFR 185.524
Action required: 10 - Deficiency Rectified
Due 13 February 2025
Resolved 13 February 2025
Resolution: Master is to start conducting drills at an interval not to exceed 3 months to ensure adequacy of training for all crew members. Master was also instructed to include details of the drills and crew memebers involved.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 February 2025
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard... The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Records of drills do not provide information that allow for tracking of members involved and therefore ensuring that each crew member is receiving adequate training. Records also do not provide details of scenario and training topics.
46 CFR 185.520
Action required: 10 - Deficiency Rectified
Due 13 February 2025
Resolved 13 February 2025
Resolution: Master is to start conducting drills at an interval not to exceed 3 months to ensure adequacy of training for all crew members. Master was also instructed to include details of the drills and crew memebers involved.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 15 February 2024
Resolved
The vessel did not program vessel's assigned MMSI number indicated on its FCC Station License into vessel's radio telephones that have DSC capabilities.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 29 February 2024
Resolution: Received verification that MMSI number was programed into the vessel's radio.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 5 February 2021
Resolved
Mark is missing for fuel shutoff valve. Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high. 46CFR185.608
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2021
Resolved 5 March 2021
Resolution: Valve is now marked
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 February 2021
Resolved
There is an extension chord on the second deck attached to running lighting. 46CFR183.200(b)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2021
Resolved 5 March 2021
Resolution: replaced with 12 gauge outdoor wire, hardwired into junction box with waterproof clamp
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 March 2017
Resolved
PROPERLY TERMINATE DEAD END WIRING IN FWD TANK SPACE.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 24 April 2017
Resolution: Wiring properly terminated.
Construction/Loadline › Penetrations › Gasket
Issued 16 March 2017
Resolved
Install new gaskets to make hatches both fore and aft weather tight, to prevent corrosion on spaces below.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 24 April 2017
Resolution: Verified replacement of gasket, owner used a softer material, space below was dry.
Lifesaving › Lifejacket/PFD (Type IV) › Storage
Issued 24 May 2016
Resolved
Life ring was secured to vessel, making it incapable of being rapidly cast loose in an emergency. 46 CFR 180.70(B)(3) requires each life ring to be stowed in a way that it can be rapidly cast loose. Remove lashing and place in appropriate mount. PRIOR TO PAX
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2016
Resolved 26 May 2016
Resolution: Removed lashing from life ring and placed in appropriate mount.
Lifesaving › Lifejacket/PFD (Type IV) › Condition
Issued 24 May 2016
Resolved
Lifeline for life ring was not attached to life ring. 46 CFR 180.70(C) requires a lifeline to be attached to at least one life ring.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Relocated and attached life ring to lifeline behind pilot house.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 May 2016
Resolved
Aux generator does not have adequate guard covering belts and machinery, creating a safety hazard. Instructed to remove and replace homemade mesh type guard with original guard/cover provided from generator manufacturer IAW 46 CFR 177.35-15 (OLD "T").
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 7 July 2016
Resolution: Attended vessel to ensure sturdiness of cover. All satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 24 May 2016
Resolved
Coffee maker and warmer were not secured in galley. Properly secure galley equipment. 46 CFR 176.25-1 (OLD "T").
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 June 2016
Resolution: Rescinded requirement due to route and service.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 24 May 2016
Resolved
Power strip mounted on galley bulkhead is not marine grade. Replace with marine grade junction box. 46 CFR 183.10-20 (OLD "T").
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 7 July 2016
Resolution: Attended vessel, inspected new permanent type outlet installment. All satisfactory.