Records from 1985 to 2026. Most recent: inspection, 9 February 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 60
9 February 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8299544
13 February 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8075806
15 February 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7868109
8 February 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7862803
21 February 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7640467
22 February 2022
COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7398567
5 February 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7136075
4 June 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6962029
13 June 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6713308
21 February 2019
Administrative Inspection · Examination of Repairs · Drydock Exam · Damage Survey · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6629979
29 September 2018
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6552813
27 March 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6379499
12 September 2017
Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6267259
16 March 2017
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6096988
24 February 2017
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6094409
24 May 2016
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5885320
12 March 2014
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4838400
8 December 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4204358
23 March 2010
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3701589
30 March 2009
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3441602
2 February 2009
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3403923
17 March 2008
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3166250
19 December 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3118163
18 December 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3117792
2 April 2007
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2899916
14 June 2006
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2680050
30 August 2005
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2479554
20 September 2004
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2201345
9 February 2004
Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2006142
9 September 2003
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1903626
27 June 2002
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1637664
25 January 2002
Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1481479
5 September 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1379551
10 July 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1437757
24 August 1999
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 781050
17 July 1999
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1452539
12 May 1999
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1130467
31 August 1998
Deficiency Check
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1132115
17 August 1998
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1433370
13 August 1997
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1364298
17 July 1996
COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1409532
28 July 1995
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 878378
21 July 1994
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 869911
20 July 1993
Deficiency Check
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 842297
1 July 1993
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1145328
22 June 1993
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1145327
26 May 1992
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 954737
4 October 1991
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1253608
5 August 1991
Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1249149
20 July 1989
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 894946
20 June 1989
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1203344
9 September 1988
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1042102
8 July 1988
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1208159
23 June 1988
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 894248
14 April 1988
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1040914
21 July 1987
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1028941
3 March 1987
Re-Inspection · Drydock Extension
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1323717
24 January 1986
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 996215
8 August 1985
Deficiency Check
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1292342
9 July 1985
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1291092
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 February 2026
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years...If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate.
Vessel missing a valid FCC Safety Radiotelephony Certificate.
47 CFR 80.903
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2026
Resolved 13 February 2026
Resolution: Owner/operator provided current copy of Radio Telephony Certificate. See certificates.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 February 2025
Resolved
The power fire pump shall be selfpriming and of such size as to discharge an effective stream from a hose connected to the highest outlet. Vessel's fire pump lines were frozen and preventing discharge.
46 CFR 181.10-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2025
Resolved 3 March 2025
Resolution: O/o was unable to repair fire pump and resorted to meeting applicable new T requirements- fire buckets. Discussed the need to update emergency instructions to reflect the inoperational status of fire pump and use of fire buckets instead.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 February 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel has 43 out of 45 serviceable life jackets on board.
46 CFR 184.420(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2025
Resolved 3 March 2025
Resolution: O/o brought into service two PFDs, meeting the total required per the COI.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 February 2025
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire... The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Records of drills do not provide information that allow for tracking of members involved and therefore ensuring that each crew member is receiving adequate training. Records also do not provide details of scenario and training topics.
46 CFR 185.524
Action required: 10 - Deficiency Rectified
Due 13 February 2025
Resolved 13 February 2025
Resolution: Master is to start conducting drills at an interval not to exceed 3 months to ensure adequacy of training for all crew members. Master was also instructed to include details of the drills and crew memebers involved.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 February 2025
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard... The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Records of drills do not provide information that allow for tracking of members involved and therefore ensuring that each crew member is receiving adequate training. Records also do not provide details of scenario and training topics.
46 CFR 185.520
Action required: 10 - Deficiency Rectified
Due 13 February 2025
Resolved 13 February 2025
Resolution: Master is to start conducting drills at an interval not to exceed 3 months to ensure adequacy of training for all crew members. Master was also instructed to include details of the drills and crew memebers involved.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 15 February 2024
Resolved
The vessel did not program vessel's assigned MMSI number indicated on its FCC Station License into vessel's radio telephones that have DSC capabilities.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 29 February 2024
Resolution: Received verification that MMSI number was programed into the vessel's radio.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 5 February 2021
Resolved
Mark is missing for fuel shutoff valve. Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high. 46CFR185.608
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2021
Resolved 5 March 2021
Resolution: Valve is now marked
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 February 2021
Resolved
There is an extension chord on the second deck attached to running lighting. 46CFR183.200(b)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2021
Resolved 5 March 2021
Resolution: replaced with 12 gauge outdoor wire, hardwired into junction box with waterproof clamp
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 March 2017
Resolved
PROPERLY TERMINATE DEAD END WIRING IN FWD TANK SPACE.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 24 April 2017
Resolution: Wiring properly terminated.
Construction/Loadline › Penetrations › Gasket
Issued 16 March 2017
Resolved
Install new gaskets to make hatches both fore and aft weather tight, to prevent corrosion on spaces below.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 24 April 2017
Resolution: Verified replacement of gasket, owner used a softer material, space below was dry.
Lifesaving › Lifejacket/PFD (Type IV) › Storage
Issued 24 May 2016
Resolved
Life ring was secured to vessel, making it incapable of being rapidly cast loose in an emergency. 46 CFR 180.70(B)(3) requires each life ring to be stowed in a way that it can be rapidly cast loose. Remove lashing and place in appropriate mount. PRIOR TO PAX
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2016
Resolved 26 May 2016
Resolution: Removed lashing from life ring and placed in appropriate mount.
Lifesaving › Lifejacket/PFD (Type IV) › Condition
Issued 24 May 2016
Resolved
Lifeline for life ring was not attached to life ring. 46 CFR 180.70(C) requires a lifeline to be attached to at least one life ring.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Relocated and attached life ring to lifeline behind pilot house.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 May 2016
Resolved
Aux generator does not have adequate guard covering belts and machinery, creating a safety hazard. Instructed to remove and replace homemade mesh type guard with original guard/cover provided from generator manufacturer IAW 46 CFR 177.35-15 (OLD "T").
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 7 July 2016
Resolution: Attended vessel to ensure sturdiness of cover. All satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 24 May 2016
Resolved
Coffee maker and warmer were not secured in galley. Properly secure galley equipment. 46 CFR 176.25-1 (OLD "T").
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 June 2016
Resolution: Rescinded requirement due to route and service.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 24 May 2016
Resolved
Power strip mounted on galley bulkhead is not marine grade. Replace with marine grade junction box. 46 CFR 183.10-20 (OLD "T").
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 7 July 2016
Resolution: Attended vessel, inspected new permanent type outlet installment. All satisfactory.
Engineering › Generator (propulsion-electric) › Battery
Issued 12 March 2014
Resolved
Provide proper wiring installation for generator start battery. 46 CFR 182.15-20(b)
Due 11 April 2014
Resolved 10 April 2014
Resolution: Proper wiring installation.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 12 March 2014
Resolved
Provide proper exhaust hose on generator. 46 CFR 183.10-20(d)
Due 11 April 2014
Resolved 10 April 2014
Resolution: Proper exhaust hose provided.
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 12 March 2014
Resolved
Vessel shall have suitable magnetic compass in pilot house with current deviation table. 46 CFR 182.20(a)
Due 11 April 2014
Resolved 10 April 2014
Resolution: Suitable compass and current deviation table provided.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 12 March 2014
Resolved
Vessel shall have Emergency Procedures posted in Pilot House. 46 CFR 185.510
Due 11 April 2014
Resolved 10 April 2014
Resolution: Emergency Procedures posted.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 March 2014
Resolved
Vessel shall provide ammonia inhalants for the first aid kit. 46 CFR 160.041(b)
Due 11 April 2014
Resolved 10 April 2014
Resolution: Ammonia inhalants provided.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 March 2009
Resolved
Bilge alarm audible indicator inoperable. Repair or renew as needed and prove proper operation.
Action required: 705 - Other - as specified
Resolved 30 March 2009
Resolution: Owner purchased and installed new audible indicator while inspection was in progress. Tested sat. Requirement satisfied.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 February 2009
Resolved
Aft hatch does not fully seal. Restore aft hatch seal to original condition IAW 46CFR176.800 to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 4 March 2009
Resolved 17 February 2009
Resolution: Aft hatch fully operational.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 18 December 2007
Resolved
Seattle Ferry Service, the owner/operator of the vsl FREMONT AVENUE did not have a Chemical Testing program in place as required by 46 CFR 16.201.
Due 18 December 2007
Resolved 18 December 2007
Resolution: Seattle Ferry Service contracted with Swedish Medical Center/Business Health Link to serve as their Chemical Testing Program Consortium/Third Party Administrator.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 2 April 2007
Resolved
Repair active fuel leak from Generatror.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2007
Resolved 3 April 2007
Resolution: Repaired active fuel leak from generator.
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 June 2006
Resolved
Operator has not been conducting drills or documenting for the FY2005-2006.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2006
Resolved 14 June 2006
Resolution: Operator has been informed on proper proceedures for conducting and logging drills.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 June 2006
Resolved
Replace burnt out bulbs in stern and stbd navigational lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2006
Resolved 14 June 2006
Resolution: Navigational light are operational.
Fire Fighting › Fire Main › Valves
Issued 14 June 2006
Resolved
Isolation valve handle on sea suction side of fire main piping is missing. Provide and demonstate proper operation of valve.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 June 2006
Resolved 14 June 2006
Resolution: Located and installed valve handle.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 June 2006
Resolved
Navigational publication are 10 years out dated. Provide up to date Light List and Coastal Pilot for operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2006
Resolved 14 June 2006
Resolution: Publication provided for areas of operation.
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 20 September 2004
Resolved
PROVIDE GUARDS OVER EXPOSED BELTS & PULLEYS ON MAIN DIESEL ENGINE & SHIP'S GENERATOR IN ACCORDANCE WITH 46 CFR 177.35-15 (10-1-95 EDITION).
Action required: 705 - Other - as specified
Due 21 October 2004
Resolved 7 October 2004
Resolution: Resolved October 7, 2004. Machinery guards installed.
Lifesaving
Issued 17 August 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 August 1998
Resolved 17 August 1998
Engineering
Issued 17 July 1996
Resolved
REPLACE EXHAUST LAGGING ON MAIN DIESEL ENGINE.
Condition: Unknown
Due 24 July 1996
Resolved 1 August 1996
Lifesaving
Issued 17 July 1996
Resolved
LIFE JACKET BOX ON UPPER DECK BEHIND PILOTHOUSE NEEDS TO BE REPAIRED. BROKEN WOOD AND RUSTY/EXPOSED SCREWS- UNSAFE FOR PASSENGERS.
Condition: Unknown
Due 24 July 1996
Resolved 1 August 1996
Electrical
Issued 17 July 1996
Resolved
ELECTRIC CABLES IN PILOTHOUSE NEED TO BE SECURED WITH METALLIC WIRE TIES.
Condition: Unknown
Due 24 July 1996
Resolved 1 August 1996
Electrical
Issued 17 July 1996
Resolved
PLACE WIRES FOR 110V LIGHT IN STEERING COMPARTMENT IN JUNCTION BOX.
Condition: Unknown
Due 24 July 1996
Resolved 1 August 1996
Accommodation/Occupational Safety
Issued 17 July 1996
Resolved
SECURE THE DRIPPING SEWAGE PIPE AT 45 DEGREE COUPLING.
Condition: Unknown
Due 24 July 1996
Resolved 1 August 1996
Electrical
Issued 17 July 1996
Resolved
ALL WIRE TIES IN ENGINE ROOM NEED TO BE METALLIC.
Condition: Unknown
Due 24 July 1996
Resolved 1 August 1996
Construction/Loadline
Issued 28 July 1995
Resolved
REMOVE WASTED AREA AROUND #2 VOID HATCH AND REPLACE IN-KIND. HATCH IS NOT DESIGNED AS A WATERTIGHT HATCH.
Condition: Unknown
Due 28 July 1995
Resolved 28 July 1995
Engineering
Issued 1 July 1993
Resolved
PROVIDE A SUITABLE MACHINERY GUARD FOR THE EXPOSED AFTER ENGINE BELT/PULLEYS IAW 46 CFR 177.35-15.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Unknown
Issued 1 July 1993
Resolved
REPAIR POTABLE WATER OVERFLOW THROUGH HULL FITTINGS AND PROVIDE SUITABLE HOSES/CLAMPS.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Accommodation/Occupational Safety
Issued 1 July 1993
Resolved
REPLACE STBD PILOT HOUSE WINDOW (SHATTERED).
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Navigation
Issued 1 July 1993
Resolved
REPAIR BROKEN STEERING LINKAGE TO RUDDER ANGLE INDICATOR SENSOR OR REMOVE SYSTEM FROM VESSEL.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Documentation
Issued 1 July 1993
Resolved
PROVIDE CURRENT/UPDATED LIGHT LISTS, COAST PILOTS, NAV RULES AND CHART #14847.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Engineering
Issued 1 July 1993
Resolved
REPAIR AND PROVE PROPER OPERATION OF MDE TACHOMETER OR REMOVE SYSTEM FROM VESSEL.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Electrical
Issued 20 June 1989
Resolved
LINE BATTERY BOXS IN FORE PEAK AND E/R WITH AN APPROVED MATERIAL
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Electrical
Issued 20 June 1989
Resolved
REPLACE BATTERY CLAMPS ON CABLES FOR BOW THRUSTER BATTERY AND MAIN ENGINE START BATTERY.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Engineering
Issued 20 June 1989
Resolved
CLEAN E/R BILGE OF EXCESS OIL.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Navigation
Issued 20 June 1989
Resolved
PROVIDE WRENCH FOR ACCESS PLATE FOR AUX STEERING.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Construction/Loadline
Issued 20 June 1989
Resolved
PROVIDE WRENCH FOR FORE PEAK VALVE REACH ROD.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Construction/Loadline
Issued 9 September 1988
Resolved
REMOVE ALL EXCESS OIL FROM ENGINE ROOM BILGE. DO NOT CARRY PASSENGERS PRIOR TO REMOVAL.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Electrical
Issued 9 September 1988
Resolved
REMOVE OF REPAIR LOOSE WIRING ON PORT SIDE OF MAIN ENGINE.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Engineering
Issued 23 June 1988
Resolved
INSTALL BELT GUARD ON AIR COMPRESSOR DRIVE PULLEY.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Electrical
Issued 23 June 1988
Resolved
INSTALL BELT GUARD ON AUX. GENERATOR.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Engineering
Issued 23 June 1988
Resolved
INSTALL BELT GUARD ON FRONT OF PROPULSUION ENGINE.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Documentation
Issued 21 July 1987
Resolved
PROVIDE EVIDENCE OF SATISFACTORY AND CURRENT DOCUMENTATION FOR THIS VESSEL TO BE COMPLETED PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 21 July 1987
Resolved 21 July 1987