Records from 2016 to 2026. Most recent: inspection, 19 May 2026.
Inspection history · 14
19 May 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8352814
22 April 2025
Annual Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8119952
1 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7896260
2 May 2023
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7679626
23 May 2022
Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7446779
25 June 2021
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7235828
27 April 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7185053
18 August 2020
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7036361
15 April 2020
Drydock Extension
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6940270
3 May 2019
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6675828
2 May 2018
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6404925
2 August 2017
Spot Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6228612
9 May 2017
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6124340
26 April 2016
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5863990
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2026
Resolved
Fire extinguisher bracket not serviceable. Repair or replace the bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 5 June 2026
Resolution: New fire extinguisher bracket is installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 April 2025
Resolved
Expired aspirin found in 1st aid kit. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2025
Resolved 2 May 2025
Resolution: new 1st aid kit purchased
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 April 2025
Resolved
Vessel required 3 fire buckets. Had 2 on board. Provide 3 fire buckets with line on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2025
Resolved 2 May 2025
Resolution: vessel now has 3 fire buckets
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 May 2024
Resolved
Ensure proper operation of vessel running lights (sidelights).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2024
Resolution: Photo evidence received
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 May 2024
Resolved
Ensure proper operation of high water alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2024
Resolution: Verbal confirmation of correction received
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 May 2024
Resolved
Vessel required (3) fire buckets (2.5 gallon, marked, with line to reach water).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2024
Resolution: Photo evidence received
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 1 May 2024
Resolved
Replace raw water hose off of strainer before main propulsion engine - hose is holed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2024
Resolution: Photo evidence of correction
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 1 May 2024
Resolved
Vessel operator - provide evidence of proper (credential) endorsement.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2024
Resolution: photo evidence of correction received
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 May 2024
Resolved
Provide and mount in a location easily visible to passengers, a lifejacket donning placard for each type of lifejacket carried on board vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2024
Resolution: photo evidence of correction received
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 1 May 2024
Resolved
Provide written procedures for recovering a man overboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2024
Resolution: photo evidence of correction received
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 May 2022
Resolved
Provide service report for/or new 10 B:C portable extinguisher at operating station. Yearly servicing was overdue at time of inspection. 46 CFR 176.801 (b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2022
Resolved 14 September 2022
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 May 2022
Resolved
Provide new approved battery for the floating electric waterlight attached to the Ring Life Buoy. 46 CFR 180.70(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2022
Resolved 14 September 2022
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 May 2022
Resolved
Provide Type II Retro-reflective material for the Ring Life Buoy. There was no retro on the buoy at time of inspection.
46CFR185.604(i)
9/14/2022: Code changed from 50c to 701c.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2022
Resolved 15 September 2022
Resolution: completed
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 May 2022
Resolved
Provide new aspirin and eye wash in medical 1st aid kit. The aspirin and eye wash were expired upon inspection.
46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2022
Resolved 14 September 2022
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 May 2022
Resolved
Each vessel not required to have a power driven fire pump must have at least 3 - 2.5 gallon fire buckets on board (marked "fire bucket" and with a lanyard). Vessel had 2 fire buckets on board at time of inspection. Provide 3 total.
46 CFR 181.610
9/14/22: code changed from 16c to 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2022
Resolved 15 September 2022
Resolution: completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2022
Resolved
Provide handle for diaphragm type pump for bilge system. No handle was on board.
9/14/2022: code changed from 50c to 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2022
Resolved 15 September 2022
Resolution: completed
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 May 2022
Resolved
Provide operable portable battery light at operating station. No "flash"light was on board.
46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2022
Resolved 14 September 2022
Resolution: completed