MAURY USCG vessel records Sign in
← All vessels

ISLAND VENTURE

ISLAND VENTURE is a 1985 passenger vessel (inspected). The Coast Guard has recorded 45 inspections since 1985, most recently in January 2010, along with 172 deficiencies and 2 operational controls.

Records from 1985 to 2010. Most recent: inspection, 6 January 2010.

Built
1985
Last inspected
6 January 2010
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCP7024
251539
Flag
UNITED STATES
367010090 (licence lapsed)
Maury page id
psix-251539

Inspections, by type

…with no type recorded1
Years with a record 22 calendar years (1985–2010)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)36.6 ft × 14.3 ft × 6.7 ft
Registered tonnagegross 20 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBETHLEHEM FAB INC · BOWLING GREEN, FL, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPONCE, PR
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Regulatory (Subpart C or D), Net Ton
20 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCP7024MMSI 367010090 · expired · compulsorily equipped · granted 11 January 2005, cancelled 21 March 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 45

6 January 2010 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3659428
19 January 2006 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2571357
7 July 2005 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2417994
14 April 2005 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2334394
23 January 2004 COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2001566
21 October 2003 Deficiency Check · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1934225
13 May 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1793237
3 October 2002 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1688478
1 October 2002 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1688453
17 November 2001 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1370435
15 November 2001 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1370434
6 October 2000 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1429434
3 November 1999 Plan Review "T" Boat
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 813400
18 August 1999 Re-Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1461196
20 December 1997 Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1368923
15 December 1997 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1443943
26 September 1997 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1406181
19 August 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1090905
25 March 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 874220
21 March 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 872606
20 December 1995 Hull Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1358994
18 April 1995 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 850499
20 September 1994 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1466354
18 January 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1162108
6 December 1993 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1157977
7 November 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1156893
26 July 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 961026
7 July 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 847556
15 June 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 836098
8 June 1992 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 954057
26 June 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1267148
13 May 1991 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1310890
25 May 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 956130
25 May 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1252843
7 December 1989 Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 913276
13 July 1989 Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 913275
18 August 1988 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1039857
20 July 1988 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1036538
19 May 1988 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1348793
4 May 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1036079
23 June 1987 Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1328575
2 December 1986 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1325089
8 July 1986 Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1013711
26 July 1985 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 989450
25 June 1985 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1291328

Deficiency record · 172

Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 14 April 2005 Resolved
Repair the fixed firefighting system to include engine sutdown, alarm at the pilot station, and connection to heat sensor.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2005
Resolution: System repaired and tested satisfactory.
Engineering › Bilge Water Management System › Not Installed
Issued 14 April 2005 Resolved
Label high level alarm light and siren at the pilot station.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2005
Engineering › Steering Gear System › Hydraulic Hose
Issued 14 April 2005 Resolved
Replace main steering hydraulic lines (2ea) under the pilot station from the helm to pressure regulator. Ensure that are secured to station.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2005
Resolution: Hoses replaced.
Fire Fighting › Ventilation Systems › Ducts
Issued 14 April 2005 Resolved
Replace fuel tank vent 30x30 mesh screen port and starboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 April 2005 Resolved
Replace expired medications from the first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2005
Resolution: Provided.
Engineering › Bilge Water Management System › Pump
Issued 14 April 2005 Resolved
Secure electric bilge pump and float to hull.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2005
Resolution: Secured.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 April 2005 Resolved
Secure high level alarm float to hull.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2005
Resolution: Secured.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 April 2005 Resolved
Provide a double house clamp to hose for engine cooling.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2005
Resolution: Provided.
Engineering › Bilge Water Management System › Hose
Issued 14 April 2005 Resolved
Provide a double hose clamp to hose port and starboard through hull fitting under the main deck amidship, used for main deck drainage.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2005
Resolution: Provided.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 14 April 2005 Resolved
Clean bilges of excessive debris and oily water.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2005
Resolution: Cleaned.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 14 April 2005 Resolved
Remove from vessel flammables not required for the operation of the vessel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2005
Resolution: Removed.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 14 April 2005 Resolved
Provide a double hose clamp to hose for sewage tank discharge line.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2005
Resolution: Provided.
Engineering › Bilge Water Management System › Piping
Issued 14 April 2005 Resolved
Repair through hull fitting starboard side amidships under the main deck used for main deck drainage.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2005
Resolution: Repaired.
Construction/Loadline › Structures
Issued 19 February 2004 Resolved
Provide a third (bottom) safety rail for the diving platform access, maximum 12" from the deck to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Safety Rails
Due 19 March 2004
Resolved 25 March 2004
Resolution: Provided.
Construction/Loadline › Structures
Issued 19 February 2004 Resolved
Replace safety rails (currently small diameter line) with, chain, wire rope or strong line that will withstand a point load of 200lbs in any direction, to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Safety Rail Material
Due 19 March 2004
Resolved 25 March 2004
Resolution: Replaced.
Lifesaving › Buoyant Apparatus
Issued 19 February 2004 Resolved
Mark buoyant apparatus with vessel's name to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Marking
Due 19 March 2004
Resolved 25 March 2004
Resolution: Marked.
Lifesaving › Lifebuoys
Issued 19 February 2004 Resolved
Provide Type II retro tape to the life buoy to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Retro-reflective Tape (Type II)
Due 16 April 2004
Resolved 20 April 2004
Engineering › Bilge Water Management System
Issued 19 February 2004 Resolved
Prove proper operation of the visual alarm for bilge high level at the operating station to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: High Level Alarm for Bilge
Due 19 March 2004
Resolved 25 March 2004
Resolution: Provided.
Stability › Weathertight Integrity
Issued 19 February 2004 Resolved
Make the forward hatch weather tight to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Forward Hatch
Due 19 March 2004
Resolved 25 March 2004
Resolution: Done.
Construction/Loadline › Penetrations
Issued 23 January 2004 Resolved
Make forward sea valve available for inspection. LEGACY COMPONENT DESC: Forward Sea Valve
Action required: 705 - Other - as specified
Resolved 3 February 2004
Construction/Loadline › Hull
Issued 23 January 2004 Resolved
Crop and renew wasted hull plating, fwd port side, as marked. LEGACY COMPONENT DESC: Bottom Plating
Action required: 705 - Other - as specified
Resolved 3 February 2004
Construction/Loadline › Hull
Issued 23 January 2004 Resolved
Properly clad weld pinhole in hull plating, fwd port side where marked. LEGACY COMPONENT DESC: Hull Plating
Action required: 705 - Other - as specified
Resolved 3 February 2004
Construction/Loadline › Structures
Issued 23 January 2004 Resolved
Inside compartment just forward of of bilge pumps - crop and renewbottom transverse frame as marked. Also, crop and renew all steel as marked due to wastage.
Action required: 705 - Other - as specified
Resolved 19 February 2004
Construction/Loadline › Structures
Issued 23 January 2004 Resolved
Crop and renew above component in shaft alley. LEGACY COMPONENT DESC: Bottom Transverse Floor Stiffner
Action required: 705 - Other - as specified
Resolved 19 February 2004
Construction/Loadline › Hull
Issued 23 January 2004 Resolved
Grind and re-weld washed out weld, stbd side bottom. LEGACY COMPONENT DESC: Weld
Action required: 705 - Other - as specified
Resolved 3 February 2004
Construction/Loadline › Structures
Issued 23 January 2004 Resolved
Crop and renew 12" section of CVK, as marked, in chain locker. LEGACY COMPONENT DESC: CVK
Action required: 705 - Other - as specified
Resolved 3 February 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 23 January 2004 Resolved
Provide label with direction of operation (Push Pull) to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Emergency Fuel Shut Off Valve
Due 19 March 2004
Resolved 25 March 2004
Resolution: Provided.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 21 October 2003 Resolved
Renew or replace all wooden passenger seating. Provide repair proposal to this office prior to installing new seating. Unsafe wooden seating removed or renewed on 28Oct03. LEGACY COMPONENT DESC: Passenger seating
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2003
Resolved 19 February 2004
Resolution: Seating renewed with new metal frame.
Construction/Loadline › Hull
Issued 21 October 2003 Resolved
Make proper repairs to hole in the starboard side above the waterline by next drydock due on Nov03. Hole is a safety hazard. LEGACY COMPONENT DESC: Side Shell
Condition: Unknown
Due 30 November 2003
Resolved 19 February 2004
Resolution: Hole re-patched.
Stability › Watertight Integrity
Issued 21 October 2003 Resolved
Make proper repairs to forward hatch and make it watertight by next dry dock due on Nov03. LEGACY COMPONENT DESC: Forward Hatch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 19 February 2004
Resolution: Requirement re-issued under acty 2001566 due on 19Mar04.
Construction/Loadline › Hull
Issued 21 October 2003 Resolved
Make proper repairs to fiberglass hole in the flying bridge, starboard side by next drydock due on Nov03. LEGACY COMPONENT DESC: Side Shell
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 19 February 2004
Resolution: Hole repaired.
Lifesaving › Buoyant Apparatus
Issued 21 October 2003 Resolved
Repair lifeline (grab rope) for the lifefloat. LEGACY COMPONENT DESC: Grab Rope
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2003
Resolved 28 October 2003
Lifesaving › Buoyant Apparatus
Issued 21 October 2003 Resolved
Provide life-float weaklink identification tag. LEGACY COMPONENT DESC: Weaklink
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 19 February 2004
Resolution: Tag provided.
Construction/Loadline › Hull
Issued 21 October 2003 Resolved
Replace plywood to main deck starboard side. Provide proposal prior to making the repairs. Repairs to be done by next drydock due on Nov03. LEGACY COMPONENT DESC: Main deck
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 19 February 2004
Resolution: Deck repaired.
Lifesaving › Lifejacket/PFD (Type I)
Issued 21 October 2003 Resolved
Stencil vessel's name on 25 adult lifejackets. LEGACY COMPONENT DESC: Marking
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2003
Resolved 28 October 2003
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 21 October 2003 Resolved
Priovide service report for the fixed fire fighting system cylinder. LEGACY COMPONENT DESC: Servicing Report
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2003
Resolved 28 October 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 21 October 2003 Resolved
Provide service report for the portable fire extinguishers. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2003
Resolved 28 October 2003
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 21 October 2003 Resolved
Rotate the fixed fire fighting systems cylinder so that the discharge nozzle faces the engine roomm, not the bulkhead. LEGACY COMPONENT DESC: Nozzle
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2003
Resolved 21 October 2003
Fire Fighting › Remote Fuel Shutoff
Issued 21 October 2003 Resolved
Install the emergency fuel shut-off valves.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2003
Resolved 21 October 2003
Fire Fighting › Remote Fuel Shutoff
Issued 21 October 2003 Resolved
Label the emergency fuel shut-off valves, with 1 inch high lettering, the purpose of the valves and direction of operation by next drydock due on Nov03..
Condition: Improper/Lack of Maintenance
Due 30 November 2003
Resolved 21 October 2003
Documentation › Certificates/Documents
Issued 21 October 2003 Resolved
provide origianl master license. LEGACY COMPONENT DESC: Master License
Condition: Unknown
Due 21 October 2003
Resolved 22 October 2003
Resolution: Owner presented original.
Engineering › Bilge Water Management System
Issued 21 October 2003 Resolved
Provide double clamp to the bilge discharge through hull fitting by next drydock due on Nov03. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 19 February 2004
Resolution: Clamps provided.
Engineering › Bilge Water Management System
Issued 21 October 2003 Resolved
Provide evidence of the electric bilge pump capacity. Bilge pump to be 10gpm minimum capacity by next drydock due on Nov03. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 19 February 2004
Resolution: Provided.
Engineering › Bilge Water Management System
Issued 21 October 2003 Resolved
Permanently attach the electric bilge pump to hull. LEGACY COMPONENT DESC: Pump
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2003
Resolved 28 October 2003
Engineering › Bilge Water Management System
Issued 21 October 2003 Resolved
Properly wire the electric bilge pump to vessel electrical system. LEGACY COMPONENT DESC: Pump
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2003
Resolved 28 October 2003
Engineering › Bilge Water Management System
Issued 21 October 2003 Resolved
Make the electric bilge pump to operate automatically. LEGACY COMPONENT DESC: Pump
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2003
Resolved 29 October 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 21 October 2003 Resolved
Provide safety lines for the aft diving platform access. LEGACY COMPONENT DESC: Open Deck Space
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2003
Resolved 19 February 2004
Resolution: Rails provided, but required a third bottom rail. Requirememt issued under acty 2001566 due on 19Mar04.
Pollution Prevention/Response › Prevention Equipment
Issued 21 October 2003 Resolved
Properly support the Marine Sanitation Device electrical discharge pump by next drydock due on Nov03. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 19 February 2004
Resolution: Supported.
Lifesaving › Buoyant Apparatus
Issued 21 October 2003 Resolved
Properly label vessel name on the life-float paddles. LEGACY COMPONENT DESC: Paddles
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 19 February 2004
Resolution: Labeled.
Engineering › Bilge Water Management System
Issued 21 October 2003 Resolved
Provide bilge high level alarms. LEGACY COMPONENT DESC: Bilge High Level Alarms
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2003
Resolved 28 October 2003
Pollution Prevention/Response › Prevention Equipment
Issued 21 October 2003 Resolved
Clean oily water from the bilges. LEGACY COMPONENT DESC: Oily Water
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2003
Resolved 28 October 2003
Lifesaving › Buoyant Apparatus
Issued 13 May 2003 Resolved
Re-install the painter with weaklink to lifefloat.
Condition: Improper Installation
Due 14 May 2003
Resolved 21 October 2003
Resolution: Re-installed.
Fire Fighting › Remote Fuel Shutoff
Issued 13 May 2003 Resolved
Label fuel shut-off valves
Condition: Improper/Lack of Maintenance
Due 14 May 2003
Resolved 21 October 2003
Resolution: Re-issued under acty 1934225 due to RIN, item 13. Master stated that valves pull cables needed to be relocated to avoid operation by passengers.
Lifesaving › Hand Flares
Issued 1 October 2002 Resolved
Provide 3 orange smoke signals. LEGACY COMPONENT DESC: Quantity
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2002
Resolution: Verified by DC1
Lifesaving › Buoyant Apparatus
Issued 1 October 2002 Resolved
Provide approved weaklink for type of bouyant apparatus.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2002
Resolution: Verified.
Lifesaving › Lifejacket/PFD (General)
Issued 1 October 2002 Resolved
Provide 4 adult lifejackets. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2002
Resolution: Verified by DC1
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 1 October 2002 Resolved
Provide 1 B-1 portable fire extinguisher. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2002
Resolution: Verified by DC1
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 1 October 2002 Resolved
Provide 1 B-II portable fire extinguisher. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2002
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 1 October 2002 Resolved
Provide annual service report for fixed fire extinguishing system.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2002
Resolution: System serviced and verified by DC1
Lifesaving
Issued 1 October 2002 Resolved
Provide EPIRB float free mechanism.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2002
Resolution: Verified by DC1
Documentation › Logs/Records
Issued 1 October 2002 Resolved
Provide training log. LEGACY COMPONENT DESC: Logbook (official)
Condition: Unknown
Due 1 November 2002
Resolved 13 May 2003
Resolution: Log Provided
Documentation › Logs/Records
Issued 1 October 2002 Resolved
Provide kifesaving equipment maintenance record.
Due 1 November 2002
Resolved 13 May 2003
Resolution: Log provided
Documentation › Logs/Records
Issued 1 October 2002 Resolved
Provide bridge log with steering, monthly fire and abandon ship drills. LEGACY COMPONENT DESC: Logbook (official)
Condition: Unknown
Due 1 November 2002
Resolved 13 May 2003
Resolution: Log Provided.
Lifesaving › Buoyant Apparatus
Issued 1 October 2002 Resolved
Mark bouyant apparatus with vessel name.
Condition: Improper/Lack of Maintenance
Due 1 November 2002
Resolved 13 May 2003
Resolution: Life float marked.
Lifesaving
Issued 1 October 2002 Resolved
Provide Coast Guard approved first aid kit.
Condition: Improper/Lack of Maintenance
Due 1 November 2002
Resolved 13 May 2003
Resolution: Provided.
Lifesaving › Lifejacket/PFD (General)
Issued 1 October 2002 Resolved
Replace reflective tape 0n 8 adult lifejackets. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Design Flaw
Due 1 November 2002
Resolved 13 May 2003
Resolution: New jackets provided.
Lifesaving › Lifejacket/PFD (General)
Issued 1 October 2002 Resolved
Separate adult lifejackets from child lifejackets. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Due 1 November 2002
Resolved 13 May 2003
Resolution: Done
Lifesaving › Lifejacket/PFD (General)
Issued 1 October 2002 Resolved
Mark stowage for lifejackets. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Due 1 November 2002
Resolved 21 October 2003
Resolution: Spaces Marked.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 1 October 2002 Resolved
Provide missing bracket for cylinder for fixed fire extinguishing system.
Condition: Improper/Lack of Maintenance
Due 1 November 2002
Resolved 13 May 2003
Resolution: Provided.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 1 October 2002 Resolved
Provide instruction at controls and in space for fixed extinguishing system.
Condition: Unknown
Due 1 November 2002
Resolved 13 May 2003
Resolution: Provided.
Electrical › Electric Supply System (service)
Issued 1 October 2002 Resolved
Remove obsolete electrical wire from pilot station. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 1 November 2002
Resolved 13 May 2003
Resolution: Removed.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 1 October 2002 Resolved
Provide adequate means to access cylinder for fixed fire extinguishing system for easy removal for recharging and inspection of cilynder.
Condition: Improper Installation
Due 1 November 2002
Resolved 21 October 2003
Resolution: Cylinder relocated.
Documentation
Issued 6 October 2000 Resolved
Vessel master to provide a valid Fcc Safety Certificate or apllication for same.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Lifesaving
Issued 6 October 2000 Resolved
Vessel to have on board six(6) orange day smoke flares to replace the existing expired orange day smoke flares.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Fire Fighting
Issued 18 August 1999 Resolved
INSTALL FIXED FIRE SYSTEM IWO ENGINE ROOM
Condition: Unknown
Due 28 November 1999
Resolved 1 December 1999
Accommodation/Occupational Safety
Issued 18 August 1999 Resolved
REPAIR / REPLACE CRACKED WINDOW IWO FORWARD CABIN PORT SIDE
Condition: Unknown
Due 18 August 1999
Resolved 18 August 1999
Construction/Loadline
Issued 18 August 1999 Resolved
FOREPEAK PUMP TO BE PROPERLY WIRED AND OPERATIONALLY TESTED
Condition: Unknown
Due 28 November 1999
Resolved 1 December 1999
Documentation
Issued 18 August 1999 Resolved
PROVIDE SATISFACTORY DRUG TESTING PROGRAM
Condition: Unknown
Due 12 December 1999
Resolved 7 December 1999
Accommodation/Occupational Safety
Issued 20 December 1997 Resolved
REMOVE OBSOLETE VENT HOLE FOR SEWAGE TANK AND CAP OFF HULL PENETRATION PORTSIDE AMIDSHIP.
Condition: Unknown
Due 20 December 1997
Resolved 20 December 1997
Electrical
Issued 20 December 1997 Resolved
REMOVE ALL DEAD ELECTRICAL WIRES AND SECURE ALL ELECTRICAL WIRES UNDER PASSENGER CABIN AND ENGINE ROOM SPACE.
Condition: Unknown
Due 20 December 1997
Resolved 20 December 1997
Engineering
Issued 20 December 1997 Resolved
PROVIDE MAINTENANCE TO SALT WATER INTAKE FOR ENGINE COOLING.
Condition: Unknown
Due 20 December 1997
Resolved 20 December 1997
Construction/Loadline
Issued 20 December 1997 Resolved
ELIMINATE PORT HOLES OR PROVIDE OPERABLE DOGS AND DEAD COVER FOR PORT HOLES.
Condition: Unknown
Due 20 December 1997
Resolved 20 December 1997
Lifesaving
Issued 26 September 1997 Resolved
PROVIDE 01 CHILD LIFE JACKET.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Construction/Loadline
Issued 26 September 1997 Resolved
RENEW LONGIDUTINAL STIFFNERS PORT AND STARBOARD SIDE OF FOREPEAK BY NEXT DRYDOCK.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Deck/Cargo
Issued 26 September 1997 Resolved
RENEW ANCHOR MOUNTING WOODEN BLOCK BY NEXT DRYDOCK.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Accommodation/Occupational Safety
Issued 26 September 1997 Resolved
REPAIR PORT/STARBOARD LIFE RAIL. STARBOARD HAS BROKEN STANCHION, PORT HAS FRACTURES AT TOP RAIL. NO PASSENGERS FORWARD OF PILOT HOUSE.
Condition: Unknown
Due 31 December 1997
Resolved 10 October 1997
Lifesaving
Issued 26 September 1997 Resolved
LABEL VESSEL NAME ON 01 ADULT AND 04 CHILD LIFE JACKETS.
Condition: Unknown
Due 26 September 1997
Resolved 2 October 1997
Documentation
Issued 26 September 1997 Resolved
PROVIDE PROOF OF APPLICACTION FOR FCC SAFETY RADIO CERTIFICATE.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Documentation
Issued 26 September 1997 Resolved
PROVIDE LOG BOOK AND RECORD CREW TRAINING.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Electrical
Issued 26 September 1997 Resolved
PROVIDE COVER OR REPLACE FLOURESCENT LIGHT IN CABIN.
Condition: Unknown
Due 26 October 1997
Resolved 10 October 1997
Electrical
Issued 26 September 1997 Resolved
CAP OFF ELECTRICAL WIRES IN CABIN STARBOARD AFT.
Condition: Unknown
Due 26 October 1997
Resolved 10 October 1997
Electrical
Issued 26 September 1997 Resolved
SECURE LOOSE WIRES FOR IN ENGINE ROOM.
Condition: Unknown
Due 26 October 1997
Resolved 10 October 1997
Construction/Loadline
Issued 26 September 1997 Resolved
CLEAN OIL FROM BILGES.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Fire Fighting
Issued 26 September 1997 Resolved
RENEW 01 B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Lifesaving
Issued 26 September 1997 Resolved
PROVIDE SIXTY (60) FEET OF DARK BUOYANT LINE FOR RING BUOY.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Lifesaving
Issued 26 September 1997 Resolved
PROVIDE WATERLIGHT WITH LANYARD AND CORROSION RESISTANT CLIP FOR RING BUOY.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Accommodation/Occupational Safety
Issued 26 September 1997 Resolved
PROVIDE DOUBLE CLAMPS FOR SEWAGE OVERBOARD HOSE.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Lifesaving
Issued 26 September 1997 Resolved
PROVIDE COAST GUARD APPROVED FIRST AID KIT.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Engineering
Issued 26 September 1997 Resolved
RENEW CLAMP ON ENGINE SEA SUCTION HOSE.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Navigation
Issued 26 September 1997 Resolved
REPAIR EMERGENCY TILLER AND PROVIDE ON BOARD.
Condition: Unknown
Due 26 September 1997
Resolved 2 October 1997
Fire Fighting
Issued 26 September 1997 Resolved
SECURE UPRIGHT OR REMOVE HALON 1301 IN ENGINE ROOM.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Engineering
Issued 26 September 1997 Resolved
SECURE FUEL FILTER TO ENGINE ROOM BULKHEAD.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Electrical
Issued 26 September 1997 Resolved
REMOVE DEAD END WIRES IN ENGINE ROOM (FORWARD BULKHEAD)
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Construction/Loadline
Issued 26 September 1997 Resolved
PROVIDE OPERABLE DOGS ON ALL PORT LIGHTS IN CABIN BY NEXT DRYDOCK.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Construction/Loadline
Issued 26 September 1997 Resolved
REMOVE HOSE AND CAP OFF ENGINE ROOM BILGE OVERBOARD OUTLET FOR BILGE SYSTEMTHAT IS NO LONGER IN SERVICE PORT SIDE BY NEXT DRYDOCK.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Lifesaving
Issued 26 September 1997 Resolved
CONDUCT UNDERWAY DRILLS IN THE PRESENCE OF COAST GUARD INSPECTOR.
Condition: Unknown
Due 26 October 1997
Resolved 10 October 1997
Construction/Loadline
Issued 26 September 1997 Resolved
GAUGE BOTTOM HULL IN VICINITY OF COMPARTMENT AFT OF COLLISION BULKHEAD UNDER PASSENGER'S CABIN BY NEXT DRYDOCK.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Navigation
Issued 26 September 1997 Resolved
PROVIDE ILLUMIATION FOR COMPASS. VESSEL RESTRICTED TO DAYLIGHT OPERATIONS ONLY UNTIL DISCREPANCY IS CORRECTED.
Condition: Unknown
Due 26 October 1997
Resolved 10 October 1997
Lifesaving
Issued 26 September 1997 Resolved
PROVIDE EVIDENCE OF EPIRB'S REGISTRATION.
Condition: Unknown
Due 26 October 1997
Resolved 10 October 1997
Construction/Loadline
Issued 26 September 1997 Resolved
REPAIR LONGITUDINAL STIFFNERS PORT AND STARBOARD AFT OF COLLISION BULKHEAD UNDER PASSENGER'S CABIN BY NEXT DRYDOCK.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Construction/Loadline
Issued 26 September 1997 Resolved
WELD VERTICAL JOINT ON COLLISION BULKHEAD BY NEXT DRYDOCK.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Construction/Loadline
Issued 26 September 1997 Resolved
PROVIDE SUITABLE PUMPING ARRANGEMENT FOR FORE PEAK BY NEXT DRYDOCK.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Electrical
Issued 26 September 1997 Resolved
SECURE LOOSE ELECTRICAL WIRING IN CABIN.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Lifesaving
Issued 26 September 1997 Resolved
PROVIDE 06 ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 26 September 1997
Resolved 2 October 1997
Engineering
Issued 26 September 1997 Resolved
REPAIR EMERGENCY FUEL SHUT-OFFS.
Condition: Unknown
Due 26 September 1997
Resolved 2 October 1997
Lifesaving
Issued 26 September 1997 Resolved
PROVIDE PAINTER, FLOATLIGHT, PADDLES, AND FLOAT-FREE ARRANGEMENT FOR LIFE FLOAT.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Lifesaving
Issued 26 September 1997 Resolved
CLEAN OR REPAINT LIFE FLOAT.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Construction/Loadline
Issued 26 September 1997 Resolved
PROVIDE ACCESS TO FOREPEAK.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Accommodation/Occupational Safety
Issued 26 September 1997 Resolved
PROVIDE LIFE LINES FOR OPENING IN STARBOARD LIFE RAIL.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Lifesaving
Issued 26 September 1997 Resolved
PROVIDE CAT I, 406 MHZ EPIRB.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Electrical
Issued 26 September 1997 Resolved
SECURE AND CAP OFF LOOSE WIRING UNDER OPERATOR'S STATION.
Condition: Unknown
Due 26 October 1997
Resolved 10 October 1997
Construction/Loadline
Issued 26 September 1997 Resolved
INSTALL MISSING DEAD COVER FOR PORT LIGHT IN HEAD BY NEXT DRYDOCK.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Lifesaving
Issued 26 September 1997 Resolved
PROVIDE LIFE JACKET PLACARD.
Condition: Unknown
Due 26 October 1997
Resolved 10 October 1997
Construction/Loadline
Issued 26 September 1997 Resolved
SUBMIT REPAIR PROPOSAL FOR MAKING DECK WATERTIGHT.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Lifesaving
Issued 26 September 1997 Resolved
PROVIDE BRACKET FOR LIFEBUOY WATERLIGHT.
Condition: Unknown
Due 26 September 1997
Resolved 2 October 1997
Fire Fighting
Issued 20 December 1995 Resolved
INSTALL PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 29 December 1995
Resolved 11 January 1996
Documentation
Issued 20 December 1995 Resolved
OBTAIN FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Fire Fighting
Issued 20 December 1995 Resolved
PERFORM DRILLS IN THE PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Lifesaving
Issued 20 December 1995 Resolved
RENEW WEAK LINK AND PROPERLY FAIRLEAD PAINTER.
Condition: Unknown
Due 29 December 1995
Resolved 11 January 1996
Construction/Loadline
Issued 20 December 1995 Resolved
RENEW UPPER DECK AFT OF PILOT STATION WHERE DRY ROTTED AND RENEW ELECTRIC WIRE SYSTEM UNDER UPPER DECK.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Electrical
Issued 20 December 1995 Resolved
REMOVE AND RENEW ALL SOLID WIRES WITH APPROVED STRANDED WIRE TYPES.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Engineering
Issued 20 December 1995 Resolved
REBUILD PROPELLER TO ELIMINATE BENT TIPS.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Accommodation/Occupational Safety
Issued 20 December 1995 Resolved
RENEW SEWAGE VENT HOSE.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Construction/Loadline
Issued 20 December 1995 Resolved
REINSTALL SIDELONGS AT INSERT AFT OF FUEL TANKS ON BOTH THE PORT AND STBD SIDES.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Lifesaving
Issued 20 December 1995 Resolved
PROCURE 2 ADULT AND 1 CHILDS LIFE JACKET TO BRING TOTAL ONBOARD TO 40 ADULTAND 4 CHILDS.
Condition: Unknown
Due 29 December 1995
Resolved 11 January 1996
Documentation
Issued 20 September 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Documentation
Issued 20 September 1994 Resolved
RENEW FCC RADIO STATION LICENSE TO SHOW NEW VESSEL NAME.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Fire Fighting
Issued 20 September 1994 Resolved
REMOVE HALON FLOODING SYSTEM CYLINDER FROM ENGINE ROOM. PROVIDE ADDITIONAL B-II EXTINGUISHER FOR A TOTAL OF 3 B-II ENTINGUISHERS.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Construction/Loadline
Issued 20 September 1994 Resolved
REMOVE SLUICE VALVE IN COLLISION BULKHEAD AND PLUG HOLE.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Documentation
Issued 20 September 1994 Resolved
PROPERLY MARK VESSEL'S NAME ON BOTH BOWS AND TRANSOM, AND HOMEPORT ON TRANSOM IN MINIMUM 4-INCH LETTERS.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Fire Fighting
Issued 20 September 1994 Resolved
PROVIDE ADDITIONAL HOSE FOR PORTABLE FIRE/BILGE PUMP OF A LENGTH CAPABLE OFREACHING OVER THE SIDE.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Navigation
Issued 20 September 1994 Resolved
PROVE PROPER OPERATION OF STEERING SYSTEM.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Deck/Cargo
Issued 20 September 1994 Resolved
PROVIDE PROPOSAL TO REPAIR LOOSE ANCHOR PULPIT.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Navigation
Issued 20 September 1994 Resolved
REPAIR ELECTRIC HORN.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Navigation
Issued 20 September 1994 Resolved
REPAIR AND RELOCATE MASTHEAD LIGHT IN ACCORDANCE WITH NAVIGATION RULES.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Accommodation/Occupational Safety
Issued 20 September 1994 Resolved
INSTALL SAFETY LINES OR CHAINS IN AN APPROPRIATE METHOD ACROSS TRANSOM OPENING.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Lifesaving
Issued 20 September 1994 Resolved
PROVIDE PROPER, SEPARATE AND MARKED STOWAGE FOR ADULT AND CHILD LIFE PRESERVERS.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Engineering
Issued 20 September 1994 Resolved
PROPERLY MARK EMERGENCY FUEL SHUT-OFF VALVES.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Documentation
Issued 20 September 1994 Resolved
PROPERLY POST COI, FCC RDAIO SAFETY CERTIFICATE, FCC RADIO STATION LICENSE,STABILITY LETTER AND EMERGENCY CHECK-OFF LIST IN A CONSPICUOUS LOCATION.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Documentation
Issued 20 September 1994 Resolved
OBTAIN FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Construction/Loadline
Issued 20 September 1994 Resolved
PROVIDE PROPOSAL TO MAKE BULKHEAD BETWEEN ENGINE ROOM AND CABIN FUME TIGHT.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Construction/Loadline
Issued 20 September 1994 Resolved
PROVIDE PROPOSAL FOR REPAIR OF WASTAGE ON FORWARD MAIN DECK AND FOREPEAK ACCESS COVER.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Documentation
Issued 20 September 1994 Resolved
DEVELOPE A COMPANY DRUG TESTING POLICY IN ACCORDANCE WITH TITLE 46 C.F.R. PART 16 FOR PRE-EMPLOYMENT, RANDOM AND AFTER ACCIDENT TESTING. PROVIDE A COPY TO THE COAST GUARD.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Electrical
Issued 20 September 1994 Resolved
PROVIDE PROPER, APPROVED STOWAGE FOR BOTH 12 VOLT BATTERIES.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Construction/Loadline
Issued 20 September 1994 Resolved
PROVIDE PROPOSAL TO REPAIR WASTAGE IN AREA OF MAIN DECK STEERING ACCESS.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Lifesaving
Issued 20 September 1994 Resolved
MARK LIFEFLOAT WITH VESSEL NAME.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Construction/Loadline
Issued 20 September 1994 Resolved
RENEW DISCHARGE HOSE FOR ELECTRIC BILGE PUMP IN CABIN BILGE. INSTALL DOUBLECLAMPS.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Construction/Loadline
Issued 20 September 1994 Resolved
INSTALL DOUBLE HOSE CLAMPS ON HAND BILGE PUMP DISCHARGE HOSE.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Fire Fighting
Issued 20 September 1994 Resolved
RELOCATE B-I PORTABLE FIRE EXTINGUISHER TO BRIDGE AND PROVIDE PROPER BRACKET. PROVIDE PROPER BRACKET FOR B-II FIRE EXTINGUISHERS IN PASSENGER AREA.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Engineering
Issued 20 September 1994 Resolved
INSTALL DOUBLE CLAMPS ON ALL MAIN ENGINE RAW WATER COOLING HOSES.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Engineering
Issued 20 September 1994 Resolved
RENEW PORT AND STBD FUEL VENT HOSES AND CLAMPS.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Engineering
Issued 20 September 1994 Resolved
RENEW PORT AND STARBOARD FUEL FILL HOSES AND CLAMPS._x001C_
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Engineering
Issued 20 September 1994 Resolved
PROVIDE PROPOSAL TO DISABLE OR PROVE OTHER USE FOR PORT AND STARBOARD AFT FUEL TANKS.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Documentation
Issued 20 September 1994 Resolved
OBTAIN ENDORSEMENT ON CERTIFICATE OF DOCUMENTATION FOR COASTWISE TRADE._x001C_
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Electrical
Issued 20 September 1994 Resolved
REMOVE INCORRECT BUTT SPLICES AND MULTIPLE SPLICES FROM ELECTRICAL WIRE RUNS AND MAKE PROPER CONNECTIONS. REMOVE PLASTIC WIRE TIES, RENEW WITH STEEL HANGERS PROPERLY ATTACHED TO HOLD WIRE RUNS AS HIGH AS POSSIBLE OUT OF THE BILGES.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Engineering
Issued 20 September 1994 Resolved
PROVIDE PROPOSAL TO RELOCATE SOUNDING OPENINGS FOR PORT AND STBD FUEL TANKSSO THAT THEY ARE NOT LOCATED IN THE TANK COMPARTMENT, ALLOWING FUMES OR OVERFLOW TO ENTER.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Lifesaving
Issued 26 July 1993 Resolved
REPAIR OR REPLACE LIFEFLOAT. PROVIDE PADDLES AND OPERABLE WATER LIGHT.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Lifesaving
Issued 26 July 1993 Resolved
PROVIDE ONE RING BUOY OF 24" OR GREATER WITH OPERABLE WATER LIGHT.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Engineering
Issued 26 July 1993 Resolved
PROVE PROPER OPERATION OF PROPULSION MACHINERY.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Electrical
Issued 26 July 1993 Resolved
PROVIDE SUITABLE NUMBER OF EMERGENCY LIGHTS (MIN.2).
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Unknown
Issued 19 May 1988 Resolved
1 PROVIDE BILGE PUMPING CAPABILITY IN ACCORDANCE WITH 46 CFR 182.25-5.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Construction/Loadline
Issued 4 May 1988 Resolved
CROP AND RE-NEW 2 FEET OF 5/8-INCH KEEL PLATE MIDSHIPS IN WAY OF ORIGINAL SEAM. CROP ALONG EXISTING CONNECTION TO HULL USING PROPER STRESS RELIEF.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.