← All vessels
ISLAND VENTURE
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named ISLAND VENTURE
ISLAND VENTURE is a 1985 passenger vessel (inspected). The Coast Guard has recorded 45 inspections since 1985, most recently in January 2010, along with 172 deficiencies and 2 operational controls.
Records from 1985 to 2010. Most recent: inspection, 6 January 2010.
- Built
- 1985
- Last inspected
- 6 January 2010
- Documentation
- No Operation - PM · documentation file of 10 September 2026
- Deficiencies
- 172 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
680340
WCP7024
251539
Flag
UNITED STATES
367010090 (licence lapsed)
Maury page id
psix-251539
Inspections, by type
…with no type recorded1
Years with a record
22 calendar years (1985–2010)
The 45 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)36.6 ft × 14.3 ft × 6.7 ft
Registered tonnagegross 20 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBETHLEHEM FAB INC · BOWLING GREEN, FL, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPONCE, PR
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Regulatory (Subpart C or D), Net Ton
20 - Regulatory (Subpart C or D), Gross Ton
20 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WCP7024MMSI 367010090 · expired · compulsorily equipped · granted 11 January 2005, cancelled 21 March 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 45
6 January 2010
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3659428
19 January 2006
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2571357
7 July 2005
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2417994
14 April 2005
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2334394
23 January 2004
COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2001566
21 October 2003
Deficiency Check · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1934225
13 May 2003
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1793237
3 October 2002
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1688478
1 October 2002
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1688453
17 November 2001
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1370435
15 November 2001
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1370434
6 October 2000
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1429434
3 November 1999
Plan Review "T" Boat
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 813400
18 August 1999
Re-Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1461196
20 December 1997
Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1368923
15 December 1997
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1443943
26 September 1997
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1406181
19 August 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1090905
25 March 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 874220
21 March 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 872606
20 December 1995
Hull Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1358994
18 April 1995
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 850499
20 September 1994
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1466354
18 January 1994
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1162108
6 December 1993
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1157977
7 November 1993
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1156893
26 July 1993
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 961026
7 July 1993
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 847556
15 June 1993
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 836098
8 June 1992
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 954057
26 June 1991
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1267148
13 May 1991
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1310890
25 May 1990
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 956130
25 May 1990
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1252843
7 December 1989
Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 913276
13 July 1989
Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 913275
18 August 1988
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1039857
20 July 1988
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1036538
19 May 1988
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1348793
4 May 1988
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1036079
23 June 1987
Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1328575
2 December 1986
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1325089
8 July 1986
Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1013711
26 July 1985
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 989450
25 June 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1291328
Deficiency record · 172
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 14 April 2005
Resolved
Repair the fixed firefighting system to include engine sutdown, alarm at the pilot station, and connection to heat sensor.
Engineering › Bilge Water Management System › Not Installed
Issued 14 April 2005
Resolved
Label high level alarm light and siren at the pilot station.
Engineering › Steering Gear System › Hydraulic Hose
Issued 14 April 2005
Resolved
Replace main steering hydraulic lines (2ea) under the pilot station from the helm to pressure regulator. Ensure that are secured to station.
Fire Fighting › Ventilation Systems › Ducts
Issued 14 April 2005
Resolved
Replace fuel tank vent 30x30 mesh screen port and starboard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 April 2005
Resolved
Replace expired medications from the first aid kit.
Engineering › Bilge Water Management System › Pump
Issued 14 April 2005
Resolved
Secure electric bilge pump and float to hull.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 April 2005
Resolved
Secure high level alarm float to hull.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 April 2005
Resolved
Provide a double house clamp to hose for engine cooling.
Engineering › Bilge Water Management System › Hose
Issued 14 April 2005
Resolved
Provide a double hose clamp to hose port and starboard through hull fitting under the main deck amidship, used for main deck drainage.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 14 April 2005
Resolved
Clean bilges of excessive debris and oily water.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 14 April 2005
Resolved
Remove from vessel flammables not required for the operation of the vessel.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 14 April 2005
Resolved
Provide a double hose clamp to hose for sewage tank discharge line.
Engineering › Bilge Water Management System › Piping
Issued 14 April 2005
Resolved
Repair through hull fitting starboard side amidships under the main deck used for main deck drainage.
Construction/Loadline › Structures
Issued 19 February 2004
Resolved
Provide a third (bottom) safety rail for the diving platform access, maximum 12" from the deck to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Safety Rails
Construction/Loadline › Structures
Issued 19 February 2004
Resolved
Replace safety rails (currently small diameter line) with, chain, wire rope or strong line that will withstand a point load of 200lbs in any direction, to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Safety Rail Material
Lifesaving › Buoyant Apparatus
Issued 19 February 2004
Resolved
Mark buoyant apparatus with vessel's name to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Marking
Lifesaving › Lifebuoys
Issued 19 February 2004
Resolved
Provide Type II retro tape to the life buoy to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Retro-reflective Tape (Type II)
Engineering › Bilge Water Management System
Issued 19 February 2004
Resolved
Prove proper operation of the visual alarm for bilge high level at the operating station to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: High Level Alarm for Bilge
Stability › Weathertight Integrity
Issued 19 February 2004
Resolved
Make the forward hatch weather tight to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Forward Hatch
Construction/Loadline › Penetrations
Issued 23 January 2004
Resolved
Make forward sea valve available for inspection. LEGACY COMPONENT DESC: Forward Sea Valve
Construction/Loadline › Hull
Issued 23 January 2004
Resolved
Crop and renew wasted hull plating, fwd port side, as marked. LEGACY COMPONENT DESC: Bottom Plating
Construction/Loadline › Hull
Issued 23 January 2004
Resolved
Properly clad weld pinhole in hull plating, fwd port side where marked. LEGACY COMPONENT DESC: Hull Plating
Construction/Loadline › Structures
Issued 23 January 2004
Resolved
Inside compartment just forward of of bilge pumps - crop and renewbottom transverse frame as marked. Also, crop and renew all steel as marked due to wastage.
Construction/Loadline › Structures
Issued 23 January 2004
Resolved
Crop and renew above component in shaft alley. LEGACY COMPONENT DESC: Bottom Transverse Floor Stiffner
Construction/Loadline › Hull
Issued 23 January 2004
Resolved
Grind and re-weld washed out weld, stbd side bottom. LEGACY COMPONENT DESC: Weld
Construction/Loadline › Structures
Issued 23 January 2004
Resolved
Crop and renew 12" section of CVK, as marked, in chain locker. LEGACY COMPONENT DESC: CVK
Engineering › Diesel Engine (propulsion-direct drive)
Issued 23 January 2004
Resolved
Provide label with direction of operation (Push Pull) to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Emergency Fuel Shut Off Valve
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 21 October 2003
Resolved
Renew or replace all wooden passenger seating. Provide repair proposal to this office prior to installing new seating.
Unsafe wooden seating removed or renewed on 28Oct03. LEGACY COMPONENT DESC: Passenger seating
Construction/Loadline › Hull
Issued 21 October 2003
Resolved
Make proper repairs to hole in the starboard side above the waterline by next drydock due on Nov03. Hole is a safety hazard. LEGACY COMPONENT DESC: Side Shell
Stability › Watertight Integrity
Issued 21 October 2003
Resolved
Make proper repairs to forward hatch and make it watertight by next dry dock due on Nov03. LEGACY COMPONENT DESC: Forward Hatch
Construction/Loadline › Hull
Issued 21 October 2003
Resolved
Make proper repairs to fiberglass hole in the flying bridge, starboard side by next drydock due on Nov03. LEGACY COMPONENT DESC: Side Shell
Lifesaving › Buoyant Apparatus
Issued 21 October 2003
Resolved
Repair lifeline (grab rope) for the lifefloat. LEGACY COMPONENT DESC: Grab Rope
Lifesaving › Buoyant Apparatus
Issued 21 October 2003
Resolved
Provide life-float weaklink identification tag. LEGACY COMPONENT DESC: Weaklink
Construction/Loadline › Hull
Issued 21 October 2003
Resolved
Replace plywood to main deck starboard side. Provide proposal prior to making the repairs. Repairs to be done by next drydock due on Nov03. LEGACY COMPONENT DESC: Main deck
Lifesaving › Lifejacket/PFD (Type I)
Issued 21 October 2003
Resolved
Stencil vessel's name on 25 adult lifejackets. LEGACY COMPONENT DESC: Marking
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 21 October 2003
Resolved
Priovide service report for the fixed fire fighting system cylinder. LEGACY COMPONENT DESC: Servicing Report
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 21 October 2003
Resolved
Provide service report for the portable fire extinguishers. LEGACY COMPONENT DESC: Condition
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 21 October 2003
Resolved
Rotate the fixed fire fighting systems cylinder so that the discharge nozzle faces the engine roomm, not the bulkhead. LEGACY COMPONENT DESC: Nozzle
Fire Fighting › Remote Fuel Shutoff
Issued 21 October 2003
Resolved
Install the emergency fuel shut-off valves.
Fire Fighting › Remote Fuel Shutoff
Issued 21 October 2003
Resolved
Label the emergency fuel shut-off valves, with 1 inch high lettering, the purpose of the valves and direction of operation by next drydock due on Nov03..
Documentation › Certificates/Documents
Issued 21 October 2003
Resolved
provide origianl master license. LEGACY COMPONENT DESC: Master License
Engineering › Bilge Water Management System
Issued 21 October 2003
Resolved
Provide double clamp to the bilge discharge through hull fitting by next drydock due on Nov03. LEGACY COMPONENT DESC: Hose
Engineering › Bilge Water Management System
Issued 21 October 2003
Resolved
Provide evidence of the electric bilge pump capacity. Bilge pump to be 10gpm minimum capacity by next drydock due on Nov03. LEGACY COMPONENT DESC: Pump
Engineering › Bilge Water Management System
Issued 21 October 2003
Resolved
Permanently attach the electric bilge pump to hull. LEGACY COMPONENT DESC: Pump
Engineering › Bilge Water Management System
Issued 21 October 2003
Resolved
Properly wire the electric bilge pump to vessel electrical system. LEGACY COMPONENT DESC: Pump
Engineering › Bilge Water Management System
Issued 21 October 2003
Resolved
Make the electric bilge pump to operate automatically. LEGACY COMPONENT DESC: Pump
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 21 October 2003
Resolved
Provide safety lines for the aft diving platform access. LEGACY COMPONENT DESC: Open Deck Space
Pollution Prevention/Response › Prevention Equipment
Issued 21 October 2003
Resolved
Properly support the Marine Sanitation Device electrical discharge pump by next drydock due on Nov03. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Lifesaving › Buoyant Apparatus
Issued 21 October 2003
Resolved
Properly label vessel name on the life-float paddles. LEGACY COMPONENT DESC: Paddles
Engineering › Bilge Water Management System
Issued 21 October 2003
Resolved
Provide bilge high level alarms. LEGACY COMPONENT DESC: Bilge High Level Alarms
Pollution Prevention/Response › Prevention Equipment
Issued 21 October 2003
Resolved
Clean oily water from the bilges. LEGACY COMPONENT DESC: Oily Water
Lifesaving › Buoyant Apparatus
Issued 13 May 2003
Resolved
Re-install the painter with weaklink to lifefloat.
Fire Fighting › Remote Fuel Shutoff
Issued 13 May 2003
Resolved
Label fuel shut-off valves
Lifesaving › Hand Flares
Issued 1 October 2002
Resolved
Provide 3 orange smoke signals. LEGACY COMPONENT DESC: Quantity
Lifesaving › Buoyant Apparatus
Issued 1 October 2002
Resolved
Provide approved weaklink for type of bouyant apparatus.
Lifesaving › Lifejacket/PFD (General)
Issued 1 October 2002
Resolved
Provide 4 adult lifejackets. LEGACY COMPONENT DESC: Condition
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 1 October 2002
Resolved
Provide 1 B-1 portable fire extinguisher. LEGACY COMPONENT DESC: Condition
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 1 October 2002
Resolved
Provide 1 B-II portable fire extinguisher. LEGACY COMPONENT DESC: Condition
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 1 October 2002
Resolved
Provide annual service report for fixed fire extinguishing system.
Lifesaving
Issued 1 October 2002
Resolved
Provide EPIRB float free mechanism.
Documentation › Logs/Records
Issued 1 October 2002
Resolved
Provide training log. LEGACY COMPONENT DESC: Logbook (official)
Documentation › Logs/Records
Issued 1 October 2002
Resolved
Provide kifesaving equipment maintenance record.
Documentation › Logs/Records
Issued 1 October 2002
Resolved
Provide bridge log with steering, monthly fire and abandon ship drills. LEGACY COMPONENT DESC: Logbook (official)
Lifesaving › Buoyant Apparatus
Issued 1 October 2002
Resolved
Mark bouyant apparatus with vessel name.
Lifesaving
Issued 1 October 2002
Resolved
Provide Coast Guard approved first aid kit.
Lifesaving › Lifejacket/PFD (General)
Issued 1 October 2002
Resolved
Replace reflective tape 0n 8 adult lifejackets. LEGACY COMPONENT DESC: Retroreflective Material
Lifesaving › Lifejacket/PFD (General)
Issued 1 October 2002
Resolved
Separate adult lifejackets from child lifejackets. LEGACY COMPONENT DESC: Storage
Lifesaving › Lifejacket/PFD (General)
Issued 1 October 2002
Resolved
Mark stowage for lifejackets. LEGACY COMPONENT DESC: Storage
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 1 October 2002
Resolved
Provide missing bracket for cylinder for fixed fire extinguishing system.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 1 October 2002
Resolved
Provide instruction at controls and in space for fixed extinguishing system.
Electrical › Electric Supply System (service)
Issued 1 October 2002
Resolved
Remove obsolete electrical wire from pilot station. LEGACY COMPONENT DESC: Cable
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 1 October 2002
Resolved
Provide adequate means to access cylinder for fixed fire extinguishing system for easy removal for recharging and inspection of cilynder.
Documentation
Issued 6 October 2000
Resolved
Vessel master to provide a valid Fcc Safety Certificate or apllication for same.
Lifesaving
Issued 6 October 2000
Resolved
Vessel to have on board six(6) orange day smoke flares to replace the existing expired orange day smoke flares.
Fire Fighting
Issued 18 August 1999
Resolved
INSTALL FIXED FIRE SYSTEM IWO ENGINE ROOM
Accommodation/Occupational Safety
Issued 18 August 1999
Resolved
REPAIR / REPLACE CRACKED WINDOW IWO FORWARD CABIN PORT SIDE
Construction/Loadline
Issued 18 August 1999
Resolved
FOREPEAK PUMP TO BE PROPERLY WIRED AND OPERATIONALLY TESTED
Documentation
Issued 18 August 1999
Resolved
PROVIDE SATISFACTORY DRUG TESTING PROGRAM
Accommodation/Occupational Safety
Issued 20 December 1997
Resolved
REMOVE OBSOLETE VENT HOLE FOR SEWAGE TANK AND CAP OFF HULL PENETRATION PORTSIDE AMIDSHIP.
Electrical
Issued 20 December 1997
Resolved
REMOVE ALL DEAD ELECTRICAL WIRES AND SECURE ALL ELECTRICAL WIRES UNDER PASSENGER CABIN AND ENGINE ROOM SPACE.
Engineering
Issued 20 December 1997
Resolved
PROVIDE MAINTENANCE TO SALT WATER INTAKE FOR ENGINE COOLING.
Construction/Loadline
Issued 20 December 1997
Resolved
ELIMINATE PORT HOLES OR PROVIDE OPERABLE DOGS AND DEAD COVER FOR PORT HOLES.
Lifesaving
Issued 26 September 1997
Resolved
PROVIDE 01 CHILD LIFE JACKET.
Construction/Loadline
Issued 26 September 1997
Resolved
RENEW LONGIDUTINAL STIFFNERS PORT AND STARBOARD SIDE OF FOREPEAK BY NEXT DRYDOCK.
Deck/Cargo
Issued 26 September 1997
Resolved
RENEW ANCHOR MOUNTING WOODEN BLOCK BY NEXT DRYDOCK.
Accommodation/Occupational Safety
Issued 26 September 1997
Resolved
REPAIR PORT/STARBOARD LIFE RAIL. STARBOARD HAS BROKEN STANCHION, PORT HAS FRACTURES AT TOP RAIL. NO PASSENGERS FORWARD OF PILOT HOUSE.
Lifesaving
Issued 26 September 1997
Resolved
LABEL VESSEL NAME ON 01 ADULT AND 04 CHILD LIFE JACKETS.
Documentation
Issued 26 September 1997
Resolved
PROVIDE PROOF OF APPLICACTION FOR FCC SAFETY RADIO CERTIFICATE.
Documentation
Issued 26 September 1997
Resolved
PROVIDE LOG BOOK AND RECORD CREW TRAINING.
Electrical
Issued 26 September 1997
Resolved
PROVIDE COVER OR REPLACE FLOURESCENT LIGHT IN CABIN.
Electrical
Issued 26 September 1997
Resolved
CAP OFF ELECTRICAL WIRES IN CABIN STARBOARD AFT.
Electrical
Issued 26 September 1997
Resolved
SECURE LOOSE WIRES FOR IN ENGINE ROOM.
Construction/Loadline
Issued 26 September 1997
Resolved
CLEAN OIL FROM BILGES.
Fire Fighting
Issued 26 September 1997
Resolved
RENEW 01 B-II FIRE EXTINGUISHER.
Lifesaving
Issued 26 September 1997
Resolved
PROVIDE SIXTY (60) FEET OF DARK BUOYANT LINE FOR RING BUOY.
Lifesaving
Issued 26 September 1997
Resolved
PROVIDE WATERLIGHT WITH LANYARD AND CORROSION RESISTANT CLIP FOR RING BUOY.
Accommodation/Occupational Safety
Issued 26 September 1997
Resolved
PROVIDE DOUBLE CLAMPS FOR SEWAGE OVERBOARD HOSE.
Lifesaving
Issued 26 September 1997
Resolved
PROVIDE COAST GUARD APPROVED FIRST AID KIT.
Engineering
Issued 26 September 1997
Resolved
RENEW CLAMP ON ENGINE SEA SUCTION HOSE.
Navigation
Issued 26 September 1997
Resolved
REPAIR EMERGENCY TILLER AND PROVIDE ON BOARD.
Fire Fighting
Issued 26 September 1997
Resolved
SECURE UPRIGHT OR REMOVE HALON 1301 IN ENGINE ROOM.
Engineering
Issued 26 September 1997
Resolved
SECURE FUEL FILTER TO ENGINE ROOM BULKHEAD.
Electrical
Issued 26 September 1997
Resolved
REMOVE DEAD END WIRES IN ENGINE ROOM (FORWARD BULKHEAD)
Construction/Loadline
Issued 26 September 1997
Resolved
PROVIDE OPERABLE DOGS ON ALL PORT LIGHTS IN CABIN BY NEXT DRYDOCK.
Construction/Loadline
Issued 26 September 1997
Resolved
REMOVE HOSE AND CAP OFF ENGINE ROOM BILGE OVERBOARD OUTLET FOR BILGE SYSTEMTHAT IS NO LONGER IN SERVICE PORT SIDE BY NEXT DRYDOCK.
Lifesaving
Issued 26 September 1997
Resolved
CONDUCT UNDERWAY DRILLS IN THE PRESENCE OF COAST GUARD INSPECTOR.
Construction/Loadline
Issued 26 September 1997
Resolved
GAUGE BOTTOM HULL IN VICINITY OF COMPARTMENT AFT OF COLLISION BULKHEAD UNDER PASSENGER'S CABIN BY NEXT DRYDOCK.
Navigation
Issued 26 September 1997
Resolved
PROVIDE ILLUMIATION FOR COMPASS. VESSEL RESTRICTED TO DAYLIGHT OPERATIONS ONLY UNTIL DISCREPANCY IS CORRECTED.
Lifesaving
Issued 26 September 1997
Resolved
PROVIDE EVIDENCE OF EPIRB'S REGISTRATION.
Construction/Loadline
Issued 26 September 1997
Resolved
REPAIR LONGITUDINAL STIFFNERS PORT AND STARBOARD AFT OF COLLISION BULKHEAD UNDER PASSENGER'S CABIN BY NEXT DRYDOCK.
Construction/Loadline
Issued 26 September 1997
Resolved
WELD VERTICAL JOINT ON COLLISION BULKHEAD BY NEXT DRYDOCK.
Construction/Loadline
Issued 26 September 1997
Resolved
PROVIDE SUITABLE PUMPING ARRANGEMENT FOR FORE PEAK BY NEXT DRYDOCK.
Electrical
Issued 26 September 1997
Resolved
SECURE LOOSE ELECTRICAL WIRING IN CABIN.
Lifesaving
Issued 26 September 1997
Resolved
PROVIDE 06 ORANGE SMOKE DISTRESS SIGNALS.
Engineering
Issued 26 September 1997
Resolved
REPAIR EMERGENCY FUEL SHUT-OFFS.
Lifesaving
Issued 26 September 1997
Resolved
PROVIDE PAINTER, FLOATLIGHT, PADDLES, AND FLOAT-FREE ARRANGEMENT FOR LIFE FLOAT.
Lifesaving
Issued 26 September 1997
Resolved
CLEAN OR REPAINT LIFE FLOAT.
Construction/Loadline
Issued 26 September 1997
Resolved
PROVIDE ACCESS TO FOREPEAK.
Accommodation/Occupational Safety
Issued 26 September 1997
Resolved
PROVIDE LIFE LINES FOR OPENING IN STARBOARD LIFE RAIL.
Lifesaving
Issued 26 September 1997
Resolved
PROVIDE CAT I, 406 MHZ EPIRB.
Electrical
Issued 26 September 1997
Resolved
SECURE AND CAP OFF LOOSE WIRING UNDER OPERATOR'S STATION.
Construction/Loadline
Issued 26 September 1997
Resolved
INSTALL MISSING DEAD COVER FOR PORT LIGHT IN HEAD BY NEXT DRYDOCK.
Lifesaving
Issued 26 September 1997
Resolved
PROVIDE LIFE JACKET PLACARD.
Construction/Loadline
Issued 26 September 1997
Resolved
SUBMIT REPAIR PROPOSAL FOR MAKING DECK WATERTIGHT.
Lifesaving
Issued 26 September 1997
Resolved
PROVIDE BRACKET FOR LIFEBUOY WATERLIGHT.
Fire Fighting
Issued 20 December 1995
Resolved
INSTALL PORTABLE FIRE EXTINGUISHERS
Documentation
Issued 20 December 1995
Resolved
OBTAIN FCC SAFETY CERTIFICATE.
Fire Fighting
Issued 20 December 1995
Resolved
PERFORM DRILLS IN THE PRESENCE OF MARINE INSPECTOR.
Lifesaving
Issued 20 December 1995
Resolved
RENEW WEAK LINK AND PROPERLY FAIRLEAD PAINTER.
Construction/Loadline
Issued 20 December 1995
Resolved
RENEW UPPER DECK AFT OF PILOT STATION WHERE DRY ROTTED AND RENEW ELECTRIC WIRE SYSTEM UNDER UPPER DECK.
Electrical
Issued 20 December 1995
Resolved
REMOVE AND RENEW ALL SOLID WIRES WITH APPROVED STRANDED WIRE TYPES.
Engineering
Issued 20 December 1995
Resolved
REBUILD PROPELLER TO ELIMINATE BENT TIPS.
Accommodation/Occupational Safety
Issued 20 December 1995
Resolved
RENEW SEWAGE VENT HOSE.
Construction/Loadline
Issued 20 December 1995
Resolved
REINSTALL SIDELONGS AT INSERT AFT OF FUEL TANKS ON BOTH THE PORT AND STBD SIDES.
Lifesaving
Issued 20 December 1995
Resolved
PROCURE 2 ADULT AND 1 CHILDS LIFE JACKET TO BRING TOTAL ONBOARD TO 40 ADULTAND 4 CHILDS.
Documentation
Issued 20 September 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation
Issued 20 September 1994
Resolved
RENEW FCC RADIO STATION LICENSE TO SHOW NEW VESSEL NAME.
Fire Fighting
Issued 20 September 1994
Resolved
REMOVE HALON FLOODING SYSTEM CYLINDER FROM ENGINE ROOM. PROVIDE ADDITIONAL B-II EXTINGUISHER FOR A TOTAL OF 3 B-II ENTINGUISHERS.
Construction/Loadline
Issued 20 September 1994
Resolved
REMOVE SLUICE VALVE IN COLLISION BULKHEAD AND PLUG HOLE.
Documentation
Issued 20 September 1994
Resolved
PROPERLY MARK VESSEL'S NAME ON BOTH BOWS AND TRANSOM, AND HOMEPORT ON TRANSOM IN MINIMUM 4-INCH LETTERS.
Fire Fighting
Issued 20 September 1994
Resolved
PROVIDE ADDITIONAL HOSE FOR PORTABLE FIRE/BILGE PUMP OF A LENGTH CAPABLE OFREACHING OVER THE SIDE.
Navigation
Issued 20 September 1994
Resolved
PROVE PROPER OPERATION OF STEERING SYSTEM.
Deck/Cargo
Issued 20 September 1994
Resolved
PROVIDE PROPOSAL TO REPAIR LOOSE ANCHOR PULPIT.
Navigation
Issued 20 September 1994
Resolved
REPAIR ELECTRIC HORN.
Navigation
Issued 20 September 1994
Resolved
REPAIR AND RELOCATE MASTHEAD LIGHT IN ACCORDANCE WITH NAVIGATION RULES.
Accommodation/Occupational Safety
Issued 20 September 1994
Resolved
INSTALL SAFETY LINES OR CHAINS IN AN APPROPRIATE METHOD ACROSS TRANSOM OPENING.
Lifesaving
Issued 20 September 1994
Resolved
PROVIDE PROPER, SEPARATE AND MARKED STOWAGE FOR ADULT AND CHILD LIFE PRESERVERS.
Engineering
Issued 20 September 1994
Resolved
PROPERLY MARK EMERGENCY FUEL SHUT-OFF VALVES.
Documentation
Issued 20 September 1994
Resolved
PROPERLY POST COI, FCC RDAIO SAFETY CERTIFICATE, FCC RADIO STATION LICENSE,STABILITY LETTER AND EMERGENCY CHECK-OFF LIST IN A CONSPICUOUS LOCATION.
Documentation
Issued 20 September 1994
Resolved
OBTAIN FCC RADIO SAFETY CERTIFICATE.
Construction/Loadline
Issued 20 September 1994
Resolved
PROVIDE PROPOSAL TO MAKE BULKHEAD BETWEEN ENGINE ROOM AND CABIN FUME TIGHT.
Construction/Loadline
Issued 20 September 1994
Resolved
PROVIDE PROPOSAL FOR REPAIR OF WASTAGE ON FORWARD MAIN DECK AND FOREPEAK ACCESS COVER.
Documentation
Issued 20 September 1994
Resolved
DEVELOPE A COMPANY DRUG TESTING POLICY IN ACCORDANCE WITH TITLE 46 C.F.R. PART 16 FOR PRE-EMPLOYMENT, RANDOM AND AFTER ACCIDENT TESTING. PROVIDE A COPY TO THE COAST GUARD.
Electrical
Issued 20 September 1994
Resolved
PROVIDE PROPER, APPROVED STOWAGE FOR BOTH 12 VOLT BATTERIES.
Construction/Loadline
Issued 20 September 1994
Resolved
PROVIDE PROPOSAL TO REPAIR WASTAGE IN AREA OF MAIN DECK STEERING ACCESS.
Lifesaving
Issued 20 September 1994
Resolved
MARK LIFEFLOAT WITH VESSEL NAME.
Construction/Loadline
Issued 20 September 1994
Resolved
RENEW DISCHARGE HOSE FOR ELECTRIC BILGE PUMP IN CABIN BILGE. INSTALL DOUBLECLAMPS.
Construction/Loadline
Issued 20 September 1994
Resolved
INSTALL DOUBLE HOSE CLAMPS ON HAND BILGE PUMP DISCHARGE HOSE.
Fire Fighting
Issued 20 September 1994
Resolved
RELOCATE B-I PORTABLE FIRE EXTINGUISHER TO BRIDGE AND PROVIDE PROPER BRACKET. PROVIDE PROPER BRACKET FOR B-II FIRE EXTINGUISHERS IN PASSENGER AREA.
Engineering
Issued 20 September 1994
Resolved
INSTALL DOUBLE CLAMPS ON ALL MAIN ENGINE RAW WATER COOLING HOSES.
Engineering
Issued 20 September 1994
Resolved
RENEW PORT AND STBD FUEL VENT HOSES AND CLAMPS.
Engineering
Issued 20 September 1994
Resolved
RENEW PORT AND STARBOARD FUEL FILL HOSES AND CLAMPS._x001C_
Engineering
Issued 20 September 1994
Resolved
PROVIDE PROPOSAL TO DISABLE OR PROVE OTHER USE FOR PORT AND STARBOARD AFT FUEL TANKS.
Documentation
Issued 20 September 1994
Resolved
OBTAIN ENDORSEMENT ON CERTIFICATE OF DOCUMENTATION FOR COASTWISE TRADE._x001C_
Electrical
Issued 20 September 1994
Resolved
REMOVE INCORRECT BUTT SPLICES AND MULTIPLE SPLICES FROM ELECTRICAL WIRE RUNS AND MAKE PROPER CONNECTIONS. REMOVE PLASTIC WIRE TIES, RENEW WITH STEEL HANGERS PROPERLY ATTACHED TO HOLD WIRE RUNS AS HIGH AS POSSIBLE OUT OF THE BILGES.
Engineering
Issued 20 September 1994
Resolved
PROVIDE PROPOSAL TO RELOCATE SOUNDING OPENINGS FOR PORT AND STBD FUEL TANKSSO THAT THEY ARE NOT LOCATED IN THE TANK COMPARTMENT, ALLOWING FUMES OR OVERFLOW TO ENTER.
Lifesaving
Issued 26 July 1993
Resolved
REPAIR OR REPLACE LIFEFLOAT. PROVIDE PADDLES AND OPERABLE WATER LIGHT.
Lifesaving
Issued 26 July 1993
Resolved
PROVIDE ONE RING BUOY OF 24" OR GREATER WITH OPERABLE WATER LIGHT.
Engineering
Issued 26 July 1993
Resolved
PROVE PROPER OPERATION OF PROPULSION MACHINERY.
Electrical
Issued 26 July 1993
Resolved
PROVIDE SUITABLE NUMBER OF EMERGENCY LIGHTS (MIN.2).
Unknown
Issued 19 May 1988
Resolved
1 PROVIDE BILGE PUMPING CAPABILITY IN ACCORDANCE WITH 46 CFR 182.25-5.
Construction/Loadline
Issued 4 May 1988
Resolved
CROP AND RE-NEW 2 FEET OF 5/8-INCH KEEL PLATE MIDSHIPS IN WAY OF ORIGINAL SEAM. CROP ALONG EXISTING CONNECTION TO HULL USING PROPER STRESS RELIEF.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.