Records from 1985 to 2004. Most recent: inspection, 2 October 2004.
Inspection history · 41
2 October 2004
ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2210909
16 April 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1774705
2 April 2003
Ballast Water Examination · Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1767072
29 December 2002
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1723920
9 December 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1716157
7 March 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 287883
8 October 1998
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 806681
3 September 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 796840
20 January 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 9348
11 January 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 411740
25 August 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 407112
25 August 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1120341
20 December 1996
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 398658
24 November 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 398664
24 November 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1106118
13 December 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 470044
26 October 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 384096
4 June 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 379135
4 June 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1184812
1 March 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 498082
1 March 1994
Tank Vessel Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1414259
11 August 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 360119
19 June 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464470
24 April 1993
MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1150668
23 July 1992
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 455170
15 February 1992
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1257650
11 October 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 339750
12 August 1989
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 331976
12 August 1989
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1038614
11 July 1988
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 896922
15 June 1988
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 323869
15 June 1988
Certificate of Compliance
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1202736
1 April 1988
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 992044
11 July 1987
MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1324159
11 July 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1327618
22 February 1987
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 528753
8 May 1986
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 308688
15 November 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1294530
14 November 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 464995
4 November 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 305165
25 October 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 304964
Pollution Prevention/Response › Prevention Equipment
Issued 2 April 2003
Resolved
Vessel's Oily-Water Separator piping has been altered from its original design, discharging oily-water directly to the bilge when the Oily-Water Separator alarm exceeds 15ppm. Vessel is prohibited using the Oily-Water Separator in U.S. water until class has approved the system piping. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 April 2003
Resolved 4 April 2003
Resolution: Received class report attesting to the correct piping arrangement (new piping was added to direct oily-water of greater than 15ppm to the bilge holding tank).
Pollution Prevention/Response › Prevention Equipment
Issued 2 April 2003
Resolved
Oily-Water Separator unit, first and second stage vessels, have temporary welds and inserts installed. Vessel is prohibited from using the Oily-Water Separator in U.S. waters until class has approved system alteration. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2003
Resolved 4 April 2003
Resolution: Received class report attesting to permanent repairs to the Oily-Water Separator first and second stage vessels.
Lifesaving › Lifeboat Equipment
Issued 29 December 2002
Resolved
(10) FOOD RATIONS NEEDED TO MEET CAPACITY OF LIFE BOAT REQUIRMENTS.
SOLAS 74/78 CH III/ REG 41.8.12. TO BE CORRECTED PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Food Ration
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2002
Resolution: RECEIVED FAXED RECIEPT FOR PURCHASE OF (10) FOOD RATIONS FROM DELAWARE SHIP SUPPLY CO.
Fire Fighting › Fixed Deck Foam System
Issued 29 December 2002
Resolved
LEAKING COUPLING OBSERVED ON FIXED FOAM FIRE FIGHTING PIPLINE. A REQUIREMENT OF SOLAS 74/78 CH.II-2/ REG 61. TO BE CORRECTED PRIOR TO NEXT U.S. PORT, AFTER SAILING FOREIGN. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 April 2003
Resolution: Deficiency rectified during 4/2/03 boarding.
Deck/Cargo › Holds/Tanks
Issued 29 December 2002
Resolved
PORT & STBD CARGO WING TANKS NOT FITTED W/ OVER-FLOW ALARMS. AS REQUIRED BY 46 CFR 153.408.
NO CARGO IS AUTHORIZED IN WING TANKS UNTIL OVER FLOW PROTECTION IS INSTALLED, WHILE IN U.S WATERS. TO BE CORRECTED PRIOR TO NEXT TRANSFER & TO THE SATISFACTION OF THE ATTENDING CG INSPECTOR. LEGACY COMPONENT DESC: Tank Level Monitoring Device
Action required: 705 - Other - as specified
Resolved 2 April 2003
Resolution: Deficiency rectified during boarding.
Construction/Loadline › Markings
Issued 29 December 2002
Resolved
DECK LINE AND LOAD LINE MARK(S) ON EITHER SIDE OF VESSEL NOT PAINTED IN A CONTRASTING COLOR TO THE HULL. AS REQUIRED BY ICLL 1966, REG 8. TO BE CORRECTED PRIOR TO NEXT U.S. PORT, AFTER SAILING FOREIGN. LEGACY COMPONENT DESC: Load Line Mark
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 April 2003
Resolution: Deficiency rectified during boarding.
Deck/Cargo
Issued 25 August 1997
Resolved
REMOVE OR REPAIR GAUGES FOR CARGO PUMPS IN CARGO CONTROL ROOM.
Condition: Unknown
Due 12 January 1998
Resolved 12 January 1998
Electrical
Issued 25 August 1997
Resolved
REPLACE LIGHT COVERS WHERE NECESSARY IN ENGINEROOM.
Condition: Unknown
Due 12 January 1998
Resolved 12 January 1998
Documentation
Issued 24 November 1996
Resolved
MAKE CORRECTIONS TO IOPP CERTIFICATE AND SURVEY FORM B, PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Construction/Loadline
Issued 24 November 1996
Resolved
MAKE PERMANENT REPAIRS TO #5 STARBOARD CARGO VENT PIPE, PRIOR NEXT U.S. PORT.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Navigation
Issued 24 November 1996
Resolved
PROVIDE CLASSIFICATION SURVEY REPORT ON CONDITION OF STEERING GEAR (UPPER RUDDER BEARING), PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Deck/Cargo
Issued 4 June 1995
Resolved
PROVIDE CLASS SOCIETY OF FLAG ADMINISTRATION REPORT TO MARINE SAFETY OFFICEHOUSTON CONCERNING COMPLIANCE WITH CHAPTER II - F CARGO TEMPERATURE CONTROL; SPECIFICALLY WHY NO CARGO TEMPERATURE OR PRESSURE ALARMS REQUIRED FOR CURRENT CARGO AUTHORITY.
Condition: Unknown
Due 4 July 1995
Resolved 20 June 1995
Fire Fighting
Issued 4 June 1995
Resolved
PROVIDE PROPER NON-PROTEIN FOAM EFFECTIVE FOR THE MAXIMUM POSSIBLE NUMBER OF CARGOES INTENDED TO BE CARRIED._x001C_ _x001C_ CHAPTER III-3.14 OF THE CODE
Condition: Unknown
Due 5 July 1995
Resolved 20 June 1995
Documentation
Issued 4 June 1995
Resolved
PROVIDE UP TO DATE TABLE 1 LIST OF NLS CARGOES FOR P & A MANUAL.
Condition: Unknown
Due 4 July 1995
Resolved 20 June 1995
Deck/Cargo
Issued 4 June 1995
Resolved
PROVIDE SUITABLE MARKING/STENCILING OF TANK OVERFLOW ALARM SYSTEM._x001C_ _x001C_ _x001C_ 46 CFR 153.408
Condition: Unknown
Due 4 July 1995
Resolved 20 June 1995
Deck/Cargo
Issued 4 June 1995
Resolved
REPAIR/REPLACE VISUAL ALARM INDICATOR FOR OVERFLOW VISUAL ALARM ON DECK.
Condition: Unknown
Due 4 July 1995
Resolved 20 June 1995
Lifesaving
Issued 4 June 1995
Resolved
PROVIDE AN ADDITIONAL TOXIC VAPOR DETECTOR FOR A COMPLEMENT OF TWO._x001C_ _x001C_ _x001C_ 46 CFR 153.526
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Lifesaving
Issued 4 June 1995
Resolved
PROVIDE AN ADDITIONAL OXYGEN METER FOR A TOTAL COMPLEMENT OF TWO.
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Deck/Cargo
Issued 4 June 1995
Resolved
DEMONSTRATE AUDIBLE & VISUAL ALARMS FOR CARGO MONITOR AND CONTROL SYSTEM (ODME) EXCESS FLOW RATE, HIGH PPM, POWER FAILURE, LOSS OF SAMPLE, AND RECORDING SYSTEM FAILURE._x001C_ 33 CFR 157.12
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Deck/Cargo
Issued 4 June 1995
Resolved
DEMONSTRATE SATISFACTORY OPERATION OF EMERGENCY SHUTDOWNS._x001C_ _x001C_ _x001C_ 46 CFR 153.296
Condition: Unknown
Due 6 June 1995
Resolved 6 June 1995
Deck/Cargo
Issued 4 June 1995
Resolved
PRIOR TO DISCHARGING ANY ANNEX II OF MARPOL CARGO (NLS) IN U.S. WATERS, INSTALL ADDITIONAL CARGO SYSTEM EMERGENCY SHUTDOWN._x001C_ _x001C_ 46 CFR 153.296(c)
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Documentation
Issued 4 June 1995
Resolved
PROVIDE UP TO DATE COPIES OF 46 CFR CODE OF FEDERAL REGULATIONS PARTS 1-40,150-153, AND 33 CODE OF FEDERAL REGULATIONS PARTS 125-199.
Condition: Unknown
Due 5 July 1995
Resolved 20 June 1995
Documentation
Issued 4 June 1995
Resolved
PROVIDE VALID IOPP CERTIFICATE "FORM B" WHICH REFLECTS THE VESSEL'S COMPLIANCE TO THE 1992 AMENDMENTS TO MARPOL.
Condition: Unknown
Due 5 July 1995
Resolved 20 June 1995
Lifesaving
Issued 4 June 1995
Resolved
PROVIDE 2 WORKING EXPLOSIVE METERS (LEL METERS)._x001C_ _x001C_ _x001C_ 46 CFR 153.465
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Lifesaving
Issued 4 June 1995
Resolved
PROVIDE SUITABLE PROTECTIVE EQUIPMENT OF CHEMICAL RESISTANT MATERIAL._x001C_ _x001C_ _x001C_ CHAPTER III-F 3.16.1 OF THE CODE
Condition: Unknown
Due 6 June 1995
Resolved 6 June 1995
Engineering
Issued 24 April 1993
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR ALARM SYSTEM PRIOR TO ENTERING NEXT U.S. PORT.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Deck/Cargo
Issued 24 April 1993
Resolved
REPAIR BROKEN CARGO TANK VENTS PRIOR TO ENTERING NEXT U.S. PORT.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Fire Fighting
Issued 24 April 1993
Resolved
REPAIR LEAKING FIRE MAIN PIPING EXPANSION JOINT PRIOR TO ENTERING NEXT U.S.PORT.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Navigation
Issued 11 October 1990
Resolved
DISCREPANCY: VESSEL'S LIGHT LIST FOR THE AREA TO BE TRANSITED WAS NOT _x001C_ CURRENTLY CORRECTED AS REQUIRED BY (33CFR 164.33(A)(2)
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Documentation
Issued 11 October 1990
Resolved
DISCREPANCY: VESSEL'S MACHINERY OIL RECORD BOOK DID NOT CONTAIN THE PROPER_x001C_ENTRIES AS REQUIRED BY 33 CFR 151.25(a)
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Navigation
Issued 12 August 1989
Resolved
VSL DID NOT HAVE A CURRENT U.S. COAST PILOT (VOLUME 2) ONBOARD AS REQUIRED BY 33 CFR 164.33(A)(2)(I). COAST PILOT WAS 1987 EDITION WITH NO CORRECTIONSVESSEL IS 4509 GROSS TONS. VESSEL TRANSITED NARRAGANSETT BAY ON 12 AUG 89. NO FOREIGN EQUIVALENT ONBOARD.
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Navigation
Issued 12 August 1989
Resolved
VSL DID NOT HAVE TIDAL CURRENT TABLES (ATLANTIC COAST OF NORTH AMERICA) OR FOREIGN EQUIVALENT ONBOARD AS REQUIRED BY 33 CFR 164.33 (A)(3)(II). VESSEL IS 4509 GROSS TONS. VSL TRANSITTED NARRAGANSETT BAY ON 12 AUG 89.
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Unknown
Issued 15 June 1988
Resolved
VSL LOCAL CHART 13218 (NOAA CHART) AND BA CHART 2892 NOT CURRENTLY CORRECTED AS REQ BY 33 CFR 164.33 (A)(1)(II). E.G. 6/88 CHARACTERISTICS OF BOUY. VSL TRANSITTED NARRAGANSETT BAY PROVIDENCE RIVER ON 15 JUN 88. VSL IS4509 GT. VSL USES BOTH U.S. AND BA CHARTS AND NETHER CORRECTED TO DTD.
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Navigation
Issued 25 October 1985
Resolved
VESSEL DID NOT HAVE LOG ENTRIES OF TESTS(IAW 33CFR164.25) MADE 12 HOURS PRIOR TO ENTERING U.S. WATERS AS REQUIRED BY 33CFR164.11(Q).
Condition: Unknown
Due 25 October 1985
Resolved 25 October 1985