EVEREADY

EVEREADY is a 1985 passenger vessel (inspected). The Coast Guard has recorded 63 inspections since 1985, most recently in March 2026, along with 49 deficiencies and 3 casualty investigations between 2004 and 2012.

Records from 1985 to 2026. Most recent: inspection, 20 March 2026.

Built
1985
Last inspected
20 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG7850
251610
Flag
UNITED STATES
367571450
Maury page id
psix-251610

Inspections, by type

…with no type recorded11
Years with a record 39 calendar years (1985–2026)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)119.8 ft × 25.0 ft × 7.5 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT, INC. · LOREAUVILLE LA, UNITED STATES · built 1985
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGRAND ISLE, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 15 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG7850MMSI 367571450 · active · compulsorily equipped · granted 10 February 2023, expires 23 April 2033
WDD6174MMSI 367169210 · expired · compulsorily equipped · granted 1 March 2007, cancelled 6 May 2017
WSL8544MMSI 367021340 · cancelled · compulsorily equipped · granted 2 March 2005, cancelled 21 April 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DREDGE 32 Industrial Vessel · MISLE 55019 · 2 March 2005 · activity 2302794

Inspection history · 63

20 March 2026 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8312063
1 April 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8103097
10 March 2025 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8090924
5 March 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7874256
27 February 2023 Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7642400
16 February 2022 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7397385
19 February 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7142802
17 February 2021 Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7141615
8 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108327
6 February 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6904454
11 February 2019 Drydock Exam · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6623514
14 February 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6355142
13 February 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6087748
9 February 2017 Administrative Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6085427
10 February 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5812566
6 February 2012 Examination of Repairs · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4243776
8 February 2011 Annual Inspection · Ballast Water Examination · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3941731
10 March 2010 Re-Inspection · Administrative Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3693249
10 February 2009 Hull Examination · Ballast Water Examination · Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3415571
15 February 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3148157
14 February 2008 Re-Inspection · Ballast Water Examination · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3147719
18 June 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2969349
14 March 2007 Hull Examination · COI Inspection · Examination of Repairs · Ballast Water Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2879101
30 March 2006 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2612286
4 March 2005 Examination of Repairs · Hull Examination · Damage Survey · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2305256
2 March 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2302794
6 July 2004 Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2123571
5 July 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2133619
14 June 2004 Re-Inspection · Administrative Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2102444
21 May 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1798114
15 May 2003 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1793956
16 July 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1647079
2 July 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1640071
20 May 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1618464
10 April 2002 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1601647
15 May 2001 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389383
12 January 2001 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 9942
11 May 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379081
27 April 1999 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463452
27 April 1998 Deficiency Check · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1392923
10 December 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1112928
5 May 1997 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419785
14 May 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385711
25 April 1996 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1430185
21 April 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1085805
21 April 1995 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456277
24 February 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 850745
21 April 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1398052
29 April 1993 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1397896
9 October 1992 Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1257295
6 October 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 938309
30 April 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 961803
24 June 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1215545
13 June 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1032850
2 May 1991 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1211414
3 May 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 918206
6 June 1989 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1044493
4 May 1989 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1200339
18 November 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 893665
5 May 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1344746
7 May 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1335692
8 May 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298931
16 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291170

Deficiency record · 49

03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 1 April 2025 Resolved
Number of penetrations in watertight bulkheads must be made watertight. Through hull fitting detached from bulkhead in engine room space.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2025
Resolved 1 April 2025
Resolution: Replaced/rerouted through bulkhead penetrations.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 April 2025 Resolved
Ends of fuel tank vent pipes must be fitted with removable flame screens. Starboard fuel tank vent is missing flame screen.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2025
Resolved 1 April 2025
Resolution: Installed new flame screen.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 March 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other person, and the vessel from electrical hazards. Multiple appliances were plugged into surge protector on bridge. Dead end wiring on starboard generator.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2024
Resolved 5 March 2024
Resolution: Surge protector and dead-end wiring removed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 March 2024 Resolved
Vessels must have interconnected fire detection system installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel was not equipped with interconnected fire detection system. Vessels must have interconnected fire detection system installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel was not equipped with interconnected fire detection system. 46 CFR 181.405(c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2024
Resolved 21 March 2024
Resolution: Vsl installed interconnected system.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 February 2020 Resolved
MI identified cracked welds in the rudder room - 10 welds cracked on the STBD bit post; 1 cracked weld on the top longitudinal of STBD center bulkhead; weld incomplete on the STBD void bulkhead under vent box; and 01 cracked weld on the PORT bit post.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 February 2020
Resolution: Vsl representative provided photographs of repair welds.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 13 February 2019 Resolved
Batteries in Water Lights are expired and are not the proper type, replace with approved/non expired battery
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 February 2019
Resolved 14 February 2019
Resolution: VSL Rep sent photos of new battery for water lights.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 February 2019 Resolved
Reflective tape being used on Liferings is not approved, replaced with approved type.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2019
Resolved 20 February 2019
Resolution: VSL rep sent pictures of corrected life rings
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 February 2019 Resolved
Non-conductive matting in front of switchboard is damaged and insufficent size, replace with larger mat.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2019
Resolved 14 February 2019
Resolution: VSL Rep sent photo and receipt fot new conductive mat in front of switchboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 February 2019 Resolved
Watertight door leading to engine room fittings are not watertight, need to tighten hinges to make the door watertight
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 February 2019
Resolution: VSL rep sent photos of tightened doors
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 8 February 2011 Resolved
Found 15 New PFD's onboard manufactured by Revere, Moble 108, Lot # L-6750 with defectively manufactured chect D ring clips. The stainless spring steel retainer was made too long, once the D rine is clipped in place, it cannot be unfastned.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 February 2011
Resolved 15 February 2011
Resolution: 15 replacement PFD''''s placed onboard.
Construction/Loadline › Hull › Hull Plating
Issued 14 February 2008 Resolved
Crop out & renew Port side hull plate (near generator) (18" X18") in the Engine Room (old repair) as marked .
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 February 2008
Resolved 19 February 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 February 2008 Resolved
Crop out and reweld fractured transverse angles as marked in Rudder Room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 February 2008
Resolved 19 February 2008
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 14 February 2008 Resolved
Crop out and renew marked (tripped) longitudinal angles located on the transom (Starboard side) in the Rudder Room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 February 2008
Resolved 19 February 2008
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 14 February 2008 Resolved
Failure to obtain approval of the Coast Guard for repairs/alterations to the hull.
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 15 February 2008
Lifesaving › Buoyant Apparatus
Issued 21 May 2003 Resolved
Renew 1 22 man lifefloat. LEGACY COMPONENT DESC: Lifefloats
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 21 May 2003
Lifesaving › Buoyant Apparatus
Issued 21 May 2003 Resolved
Renew all retro tape on lifefloats. LEGACY COMPONENT DESC: Lifefloats
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 21 May 2003
Lifesaving › Buoyant Apparatus
Issued 21 May 2003 Resolved
Repair waterlight on 22 man lifefloat. LEGACY COMPONENT DESC: Lifefloats
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 21 May 2003
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 May 2003 Resolved
Provide current lightlist.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 21 May 2003
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 May 2003 Resolved
Provide current tides/currents tables.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 21 May 2003
Navigation › Piloting/Steering › US Coast Pilot
Issued 21 May 2003 Resolved
Provide current lightlist.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 21 May 2003
Navigation › Piloting/Steering › River Current Tables
Issued 21 May 2003 Resolved
Provide River current tables.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 21 May 2003
Lifesaving › Lifebuoys
Issued 10 April 2002 Resolved
Renew reflective tape on all ring lifebuoys. LEGACY COMPONENT DESC: Reflective tape
Condition: Unknown
Due 11 April 2002
Resolved 11 April 2002
Construction/Loadline › Hull › Weld
Issued 10 April 2002 Resolved
Repair cracked weld found in the upper corner of the NR.2 STBD cabin void longitudinal frame.
Condition: Unknown
Due 11 April 2002
Resolved 11 April 2002
Engineering › Steering Gear System › Pin
Issued 10 April 2002 Resolved
Renew steel bushing and pin for Hydraulic Ram mounting bracket.
Condition: Unknown
Due 11 April 2002
Resolved 11 April 2002
Construction/Loadline › Hull › Transverse Frame
Issued 10 April 2002 Resolved
Repair cracked welds on the outboard side of the stbd main engine.
Condition: Unknown
Due 11 April 2002
Resolved 11 April 2002
Engineering › Bilge Water Management System
Issued 10 April 2002 Resolved
Repair rudder room bilge alarm. LEGACY COMPONENT DESC: Alarm
Condition: Unknown
Due 11 April 2002
Resolved 11 April 2002
Engineering › Lubricating Oil Storage/Transfer System › Gauge
Issued 10 April 2002 Resolved
Install sight glass guard on aft lube oil tank.
Condition: Unknown
Due 11 April 2002
Resolved 11 April 2002
Engineering › Bilge Water Management System › Pump
Issued 10 April 2002 Resolved
Mount bilge pump to foundation using nuts and bolts.
Condition: Unknown
Due 11 April 2002
Resolved 11 April 2002
Fire Fighting › Fire Pumps › Arrangement
Issued 10 April 2002 Resolved
Mount fire pump to foundation using nuts and bolts.
Condition: Unknown
Due 11 April 2002
Resolved 11 April 2002
Engineering › Sea-water System (primary cooling) › Pump
Issued 10 April 2002 Resolved
Mount the air conditioning salt water cooling pump to bracket.
Condition: Unknown
Due 11 April 2002
Resolved 11 April 2002
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 10 April 2002 Resolved
Remove water from battery box.
Due 10 April 2002
Resolved 10 April 2002
Engineering › Compressed Air System (start air)
Issued 10 April 2002 Resolved
Direct the STBD air receiver relief valve discharge to the deck plates. LEGACY COMPONENT DESC: Relief valve
Condition: Improper Installation
Due 10 April 2002
Resolved 10 April 2002
Engineering › Compressed Air System (start air)
Issued 10 April 2002 Resolved
Renew INOP pressure gauge located on the port side air receiver. LEGACY COMPONENT DESC: Gauge
Condition: Unknown
Due 10 April 2002
Resolved 10 April 2002
Construction/Loadline › Hull › Weld
Issued 10 April 2002 Resolved
Repair all cracked welds in rudder Room as marked, to the satisfaction of the attending CG Inspector.
Due 11 April 2002
Resolved 11 April 2002
Engineering › Fuel Oil Service System
Issued 10 April 2002 Resolved
Provide Blue Prints, Bill of Material or Documentation to insure the tubing used in the fuel system meets the requirements of 46 CFR 182.20-40 (Old-T) Minimum wall thickness .035 Inch. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2002
Resolved 20 May 2002
Resolution: Issued one CG-835 to renew all diesel fuel piping at the next scheduled dry-dock in May 2003. All material shall be IAW 46 CFR 182.20-40 (Old- T).
Engineering › Fuel Oil Service System › Piping
Issued 10 April 2002 Resolved
Renew all diesel fuel copper tubing at the next scheduled dry-dock in May 2003, all tubing shall meet the requirements of 46 CFR 182.20-40 (Old-T). LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 14 June 2004
Resolution: Done
Documentation
Issued 27 April 1998 Resolved
PROPERLY LOG ALL REQUIRED DRILLS IN SHIP'S LOGBOOK.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Navigation
Issued 27 April 1998 Resolved
PROVIDE VESSEL WITH CHART OF NAVIGATION AREA OF APPROPRIATE SCALE.
Condition: Unknown
Due 27 May 1998
Resolved 6 May 1998
Lifesaving
Issued 25 April 1996 Resolved
Provide and mount emergency instructions.
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Construction/Loadline
Issued 25 April 1996 Resolved
Provide strainer for bilge suction in MSD space
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Accommodation/Occupational Safety
Issued 25 April 1996 Resolved
Replace diaphram plunger for sewage pump
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Construction/Loadline
Issued 25 April 1996 Resolved
Crop and renew corner gusset braket for #4 STBD side and #5 PORT side in aft transom lazarette
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Engineering
Issued 25 April 1996 Resolved
Replace petcock fitting with a plug for fuel oil filter support housing on STBD generator
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Construction/Loadline
Issued 25 April 1996 Resolved
Provide plug for crew compartment vent on STBD side at aft house and aft compartment vent on PORT side
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Navigation
Issued 25 April 1996 Resolved
Provide the following navigation publications: Tide and Current Tables for 1996, Light List, Notice to Mariners and Chart 11361
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Lifesaving
Issued 25 April 1996 Resolved
Provide portable battery light for access to propulsion machinery space
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Electrical
Issued 2 May 1991 Resolved
REMOVE ALL PLASTIC ELECTRICAL TIES FROM ELECTRICAL CABLING IN ALL PASSENGER/CREW ACCESSES AND PROPERLY SUPPORT CABLE IN APPROVED CABLE SUPPORTS AT SPECIFIED DISTANCES.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Construction/Loadline
Issued 2 May 1991 Resolved
SUBMIT FOR APPROVAL TO MSO NEW ORLEANS NEW CONSTRUCTION, PROPOSAL FOR PERMANENT REPAIRS TO FRACTURES IN SIX TRANSVERSE FRAMES FOREWARD, UNDER ANDAFT OF MAIN ENGINES.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Electrical
Issued 4 May 1989 Resolved
REPAIR/ REPLACE FUSE HOLDERS IN PILOTHOUSE (FOR NAV LIGHTS) SO THAT FUSES CAN BE INSPECTED AND/ OR REPLACED, WHEN NECESSARY.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989

Casualty record · 3

5 July 2004Routine · role: Involved in a Marine Casualty · activity 2133619
2 March 2005Routine · role: Involved in a Marine Casualty · activity 2302794
25 April 2012Routine · role: Involved in a Marine Casualty · activity 4296882
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

SEABULK LAFAYETTE (2004–2005), LAFAYETTE (2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.