MAURY USCG vessel records Sign in
← All vessels

CORMORANT

CORMORANT is a 2001 passenger vessel (inspected). The Coast Guard has recorded 9 inspections since 2022, most recently in May 2026, along with 1 deficiency.

Records from 2022 to 2026. Most recent: inspection, 20 May 2026.

Built
2001
Last inspected
20 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN2300
Flag
UNITED STATES
368260780
Maury page id
psix-25176

Inspections, by type

Years with a record 5 calendar years (2022–2026)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)44.3 ft × 13.4 ft × 6.3 ft
Registered tonnagegross 25 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHE TALARIA COMPANY LLC · SOUTHWEST HARBOR, ME, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portWATCH HILL, RI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 20 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Gross Ton
20 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN2300MMSI 368260780 · active · compulsorily equipped · granted 7 June 2022, expires 7 June 2032
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 9

20 May 2026 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8377084
11 March 2026 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8324600
20 May 2025 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8140016
23 May 2024 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7922393
15 May 2024 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7909999
13 November 2023 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7824193
8 June 2023 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7684385
22 November 2022 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7616716
20 May 2022 Initial Certification · Hull Examination · Simplified Stability Test · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7453012

Deficiency record · 1

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 November 2023 Resolved
Boundary that separate machinery spaces from accommodation spaces must be lined with insulation. Seal Bulkhead penetrations in Engine Room. 46 CFR 177.410 (c)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 February 2024
Resolution: Vessel sent documentation attesting to the bulkhead being sealed properly. All sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.