ORBIT DIVER II

ORBIT DIVER II is a 1985 passenger vessel (uninspected). The Coast Guard has recorded 47 inspections since 1985, most recently in February 2024, along with 71 deficiencies.

Records from 1985 to 2024. Most recent: inspection, 29 February 2024.

Built
1985
Last inspected
29 February 2024
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY5531
251783
Flag
UNITED STATES
367365870 (licence lapsed)
Maury page id
psix-251783

Inspections, by type

…with no type recorded4
Years with a record 28 calendar years (1985–2024)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)24.3 ft × 10.1 ft × 4.7 ft
Registered tonnagegross 6 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderC W B ENTERPRISES INC. · MEDLEY, FL, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portBRIDGEPORT, CT
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Gross Ton
5 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY5531MMSI 367365870 · expired · voluntarily equipped · granted 1 July 2008, cancelled 15 September 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 47

29 February 2024 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7872140
19 August 2020 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7037228
6 June 2017 Internal Structural Exam · Hull Examination · Simplified Stability Test · Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6167654
6 July 2016 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5931346
27 August 2015 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5227985
9 June 2014 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4884710
11 June 2012 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4338557
28 April 2009 Hull Examination · Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3457544
17 March 2009 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3434732
5 July 2007 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2985431
13 June 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2960692
21 June 2006 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2687012
1 June 2006 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2667310
8 September 2005 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2487444
5 May 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2350216
29 October 2004 Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2230720
28 August 2003 Plan Review "T" Boat · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1889722
25 August 2003 Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1886908
29 May 2003 Internal Structural Exam · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1804972
29 May 2003 Internal Structural Exam · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1811413
7 June 2001 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1422076
17 May 2001 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1431038
19 June 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1412122
28 June 1999 MARPOL Annex V Examination · Re-Inspection · Plan Review "T" Boat
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1453631
28 May 1999 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1393162
23 April 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1127747
17 August 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1130770
12 June 1998 COI Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1045769
2 September 1997 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1120334
17 June 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 778960
22 May 1997 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1104316
23 August 1996 Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1100855
9 June 1995 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 786457
9 June 1995 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1190241
10 February 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1163327
4 June 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 948556
29 April 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 948557
26 April 1990 Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 899418
5 October 1989 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1019525
15 May 1989 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1342438
21 April 1989 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1044681
22 February 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1330655
16 July 1987 Re-Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1318248
31 October 1986 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1006441
1 July 1986 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 997688
19 July 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 972578
19 July 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1290955

Deficiency record · 71

Communications › Radio Communications › VHF Radiotelephone
Issued 28 June 2017 Resolved
Provide valid FCC Safety Certificate.
Condition: Improper/Lack of Maintenance
Due 29 July 2017
Resolved 27 July 2017
Resolution: Received copy of cert.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 28 June 2017 Resolved
Provide tamper seal for manual discharge at operator station.
Condition: Improper/Lack of Maintenance
Due 29 July 2017
Resolved 12 July 2017
Resolution: Sighted new tamper seal.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 28 June 2017 Resolved
Provide battery for the L/F float light.
Condition: Improper/Lack of Maintenance
Due 29 July 2017
Resolved 19 August 2020
Resolution: Vessel surrendered it's COI
Stability › Incline Test › General
Issued 28 June 2017 Resolved
Conduct successful incline test to determine number of passengers allowed.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2017
Resolved 19 August 2020
Resolution: Vessel surrendered it's COI
Stability › Incline Test › General
Issued 6 July 2016 Resolved
Vessel is required to complete a SST
Due 31 October 2016
Resolved 19 August 2020
Resolution: Vessel surrendered it's COI
Lifesaving › Lifebuoys › Serviceable
Issued 27 August 2015 Resolved
Vessels life ring did not have adequate retro reflective tape. Add proper retro reflective tape to life ring.
Action required: 705 - Other - as specified
Due 27 September 2015
Resolved 25 September 2015
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 August 2015 Resolved
Did not conduct MOD/FF drills. No crew member was available to assist the [name withheld] will be conducted when def check clearance is scheduled.
Action required: 705 - Other - as specified
Due 27 September 2015
Resolved 5 October 2015
Resolution: Due to vessel ending season and difficulty finding deck hands. Drills to be conudcted at next inspection for certification (2016).
Engineering › Steering Gear System › Rudder
Issued 27 August 2015 Resolved
Rudder post had a small leak. Investigate and repair cause of the leak.
Action required: 705 - Other - as specified
Due 27 September 2015
Resolved 5 October 2015
Resolution: Yard mechanic made repair to rudder post leak.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 June 2014 Resolved
Repair audible alarm for the pre -engineered Fire Boy System.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 16 June 2014
Resolution: Vessel operater replaced audible alarm and the issue has been corrected
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 11 June 2012 Resolved
Provide blanket/lagging over exhaust riser.
Action required: 705 - Other - as specified
Due 11 July 2012
Resolved 8 August 2012
Resolution: Attended vessel. Rider is now wrapped.
Engineering › Freshwater System (jacketwater cooling) › Suction Strainer
Issued 11 June 2012 Resolved
Secure raw water strainer in E.R. compartment.
Action required: 705 - Other - as specified
Due 11 July 2012
Resolved 8 August 2012
Resolution: Attended vessel, strainer is now supported.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 April 2009 Resolved
Remove stray wire in lazarette.
Action required: 705 - Other - as specified
Due 28 May 2009
Resolved 11 June 2009
Resolution: Wire has been removed
Engineering › Bilge Water Management System › Not Operational
Issued 28 April 2009 Resolved
Repair bilge alarm in lazarette.
Action required: 705 - Other - as specified
Due 28 May 2009
Resolved 11 June 2009
Resolution: Alarm has bee repaired
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 April 2009 Resolved
Replace hose on strainer in engine room.
Action required: 705 - Other - as specified
Due 28 May 2009
Resolved 11 June 2009
Resolution: Hose has been replaced
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 April 2009 Resolved
Make repairs to cable at battery terminal
Due 11 July 2009
Resolved 28 April 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 28 April 2009 Resolved
Provide Marine Operators Permit
Due 11 August 2009
Resolved 22 June 2009
Resolution: Same 835 item entered twice.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 March 2009 Resolved
Vessel overdue for annual exam - last annual was 7/05/07; vessel exam overdue on 9/6/08.
Due 11 June 2009
Resolved 11 June 2009
Resolution: Completed Annual Examination
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 June 2006 Resolved
Upper deck operating station: Secure/ remove stray wiring.
Condition: Unknown
Due 16 June 2006
Resolved 21 June 2006
Resolution: Complete.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 1 June 2006 Resolved
Provide current log for drills and bridge log.
Due 16 June 2006
Resolved 5 July 2007
Engineering › Steering Gear System › Hydraulic Hose
Issued 1 June 2006 Resolved
Prove proper operation of hydraulic sterring system- secure with permanent repairs all leaks in hydraulic arm.
Condition: Unknown
Due 16 June 2006
Resolved 21 June 2006
Resolution: Test sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2005 Resolved
Rewire electrical power to Bilge pumps with marine grade cable.
Due 1 October 2005
Resolved 26 September 2005
Resolution: Complete.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 8 September 2005 Resolved
Provide a copy of the Navigation Rules
Due 1 October 2005
Resolved 26 September 2005
Resolution: Complete.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 8 September 2005 Resolved
Provide a copy of the Tide and Current tables.
Due 1 October 2005
Resolved 6 June 2006
Navigation › Piloting/Steering › US Coast Pilot
Issued 8 September 2005 Resolved
Provide a copy of the US Coastal Pilot.
Due 1 October 2005
Resolved 6 June 2006
Resolution: Equivalent pubs.
Engineering › Bilge Water Management System › Not Operational
Issued 8 September 2005 Resolved
Prove proper operation of mid-compartment bilge pump.
Due 1 October 2005
Resolved 26 September 2005
Resolution: Test sat.
Engineering › Bilge Water Management System › Not Operational
Issued 8 September 2005 Resolved
Prove proper operation of all bilge alarms.
Due 1 October 2005
Resolved 26 September 2005
Resolution: Test sat.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 8 September 2005 Resolved
Clean excessive oil and water from bilges in engine compartment.
Condition: Improper/Lack of Maintenance
Due 9 September 2005
Resolved 26 September 2005
Resolution: Complete.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 8 September 2005 Resolved
Clean excessive oil and water from bilges in engine compartment.
Condition: Improper/Lack of Maintenance
Due 9 September 2005
Resolved 23 September 2005
Resolution: Repeat CG-835; issued in error.
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 5 May 2005 Resolved
Repair rudder shoepiece and repack rudder post.
Condition: Improper/Lack of Maintenance
Due 28 May 2005
Resolved 30 June 2005
Resolution: Completed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 May 2005 Resolved
Plug two holes in WT bulkhead between #1 & #2 voids.
Condition: Unknown
Due 28 May 2005
Resolved 27 June 2005
Resolution: Complete.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 29 October 2004 Resolved
Provide current master's FCC Radio Operator Permit.
Condition: Unknown
Due 23 November 2004
Resolved 4 November 2004
Resolution: Rcvd fax copy from O/O.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 29 October 2004 Resolved
Provide current safety radio telephony certificate.
Condition: Unknown
Due 23 November 2004
Resolved 6 June 2006
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 29 October 2004 Resolved
Conduct underway drills in presence of USCG marine inspector (no sail).
Condition: Improper/Lack of Maintenance
Due 23 November 2004
Resolved 2 November 2004
Resolution: Drill sat.
Operations/Management › Passenger Operations › Safety Orientation
Issued 29 October 2004 Resolved
Mark upper deck with max persons allowed as per stability letter.
Condition: Unknown
Due 23 November 2004
Resolved 2 November 2004
Resolution: Complete.
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 29 October 2004 Resolved
Provide current deviation card for magnetic compass.
Condition: Unknown
Due 29 April 2005
Resolved 5 July 2007
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 29 October 2004 Resolved
Provide 3 labeled fire buckets with lanyard.
Condition: Unknown
Due 23 November 2004
Resolved 2 November 2004
Resolution: Complete.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 29 October 2004 Resolved
Provide up to date current tables.
Condition: Unknown
Due 23 November 2004
Resolved 2 November 2004
Resolution: Completed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 12 October 2004 Resolved
FFE system accidentally discharged during servicing, as stated by operator in telephone conversation on this date. Installion of replacement in kind failed due to inappropriate sized fitting. Provide appropriate size fitting and proof of proper installation and servicing prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2004
Resolved 29 October 2004
Resolution: Installed verified.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 August 2003 Resolved
Operator failed to have vessel inspected within required time limit. Vessel COI suspended for failure to have annual inspection on or before 30SEP2004. Vessel is not allowed to operate with passengers until a satisfactory annual exam is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2004
Resolved 2 November 2004
Resolution: Annual exam completed this date.
Engineering › Bilge Water Management System › Not Operational
Issued 25 August 2003 Resolved
Provide one line electrical diagram and list of materials for bilge alarms to be installed in emg. compt and lazz. LEGACY COMPONENT DESC: Alarms
Due 25 September 2003
Resolved 29 October 2004
Resolution: Complete.
Navigation › Piloting/Steering
Issued 25 August 2003 Resolved
Provide updated charts and light list. LEGACY COMPONENT DESC: Coast Guard Light List
Due 2 September 2003
Resolved 28 August 2003
Resolution: O/O faxed receipt.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 August 2003 Resolved
Relabel ring buoy and life float, attach lifefloat paddles with approved lanyards.
Due 2 September 2003
Resolved 29 October 2004
Resolution: Complete.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 August 2003 Resolved
Repair wiring and prove proper operation of all deck and cabin lighting.
Due 2 September 2003
Resolved 29 October 2004
Resolution: Test sat.
Lifesaving › Hand Flares
Issued 25 August 2003 Resolved
Provide 3 additonal orange smokes LEGACY COMPONENT DESC: Quantity
Due 2 September 2003
Resolved 28 August 2003
Resolution: O/O faxed receipt.
Fire Fighting
Issued 7 June 2001 Resolved
Prove proper operation of FFE system discharge indicator light & alarm
Condition: Unknown
Due 29 June 2001
Resolved 26 June 2001
Lifesaving
Issued 7 June 2001 Resolved
Equip lifering with a 60' bouyant lifeline, 5/16" dia., dark color or resistant to u/v
Condition: Unknown
Due 29 June 2001
Resolved 26 June 2001
Lifesaving
Issued 7 June 2001 Resolved
Equip waterlight with a 3' lanyard fitted with a snap hook.
Condition: Unknown
Due 29 June 2001
Resolved 26 June 2001
Lifesaving
Issued 28 June 1999 Resolved
Make repairs to covering material on buoyant apparatus.
Condition: Unknown
Due 12 July 1999
Resolved 13 July 1999
Fire Fighting
Issued 28 June 1999 Resolved
Properly install fixed fire extinguishing system cylinder and manual operation control.
Condition: Unknown
Due 12 July 1999
Resolved 13 July 1999
Fire Fighting
Issued 23 April 1999 Resolved
SUBMIT PLANS FOR A FIXED FIRE EXTINGUISHING SYSTEM. THE VESSEL MAY NOT CARRY PASSENGERS UNTIL THE PLANS HAVE BEEN SUBMITTED AND APPROVED.
Condition: Unknown
Due 23 April 1999
Resolved 23 April 1999
Lifesaving
Issued 12 June 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 July 1998
Resolved 13 February 1999
Fire Fighting
Issued 12 June 1998 Resolved
HYDROTEST THE B-I EXTINGUISHER ON THE FLYING BRIDGE (NO BUILD OR HYDRO DATEAVAILABLE).
Condition: Unknown
Due 12 June 1998
Resolved 12 June 1998
Navigation
Issued 12 June 1998 Resolved
PROVIDE CURRENT COAST PILOT, LIGHT LIST, TIDE & CURRENT TABLE.
Condition: Unknown
Due 12 June 1998
Resolved 12 June 1998
Lifesaving
Issued 12 June 1998 Resolved
WRITE "II" ON EACH ADULT PFD FOR COMPLETE NAME OF VESSEL.
Condition: Unknown
Due 12 July 1998
Resolved 13 February 1999
Lifesaving
Issued 12 June 1998 Resolved
REPLACE REFLECTIVE TAPE ON 2 CHILD PFDS.
Condition: Unknown
Due 12 July 1998
Resolved 13 February 1999
Construction/Loadline
Issued 12 June 1998 Resolved
INSTALL HATCH KEEPER ON LAZARETTE HATCH.
Condition: Unknown
Due 12 July 1998
Resolved 13 February 1999
Documentation
Issued 12 June 1998 Resolved
PROVIDE RADIO TELEPHONY CERTIFICATE AND RADIO STATION LICENSE.
Condition: Unknown
Due 12 June 1998
Resolved 12 June 1998
Navigation
Issued 17 June 1997 Resolved
PROVIDE COPY OF NAVIGATION RULES OF THE ROAD.
Condition: Unknown
Due 17 July 1997
Resolved 22 July 1997
Lifesaving
Issued 17 June 1997 Resolved
ATTACH REFLECTIVE TAPE TO RINGBUOY AS DESCRIBED AND REPLACE BECKET LINE.
Condition: Unknown
Due 17 July 1997
Resolved 22 July 1997
Lifesaving
Issued 17 June 1997 Resolved
PROVIDE LIFEJACKET DONNING PLACARD.
Condition: Unknown
Due 17 July 1997
Resolved 2 September 1997
Fire Fighting
Issued 17 June 1997 Resolved
HYDROTEST ONE DRY CHEMICAL FIRE EXTINGUISHER (LOCATED ON THE PORT SIDE OF THE FLYING BRIDGE).
Condition: Unknown
Due 17 July 1997
Resolved 22 July 1997
Lifesaving
Issued 17 June 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 July 1997
Resolved 22 July 1997
Navigation
Issued 17 June 1997 Resolved
PROVIDE A SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 17 July 1997
Resolved 24 July 1997
Navigation
Issued 17 June 1997 Resolved
PROVIDE A DEVIATION CARD.
Condition: Unknown
Due 17 July 1997
Resolved 2 September 1997
Lifesaving
Issued 23 August 1996 Resolved
REPAIR/REPLACE LIFEFLOAT. VESSEL IS RESTRICTED TO OPERATING ONLY ON LAKES,BAYS & SOUNDS ROUTES UNTIL CORRECTED.
Condition: Unknown
Due 23 August 1996
Resolved 23 August 1996
Construction/Loadline
Issued 21 April 1989 Resolved
ANCHOR HAWSE PIPE COVER MISSING
Condition: Unknown
Due 21 April 1989
Resolved 21 April 1989
Fire Fighting
Issued 21 April 1989 Resolved
APPROVED MARINE TYPE BRACKETS FOR THREE B-II PORTABLE FIRE EXTINGUISHERS MISSING.
Condition: Unknown
Due 21 April 1989
Resolved 21 April 1989
Lifesaving
Issued 21 April 1989 Resolved
REPAIR/REPLACE LIFERING.
Condition: Unknown
Due 21 April 1989
Resolved 21 April 1989
Documentation
Issued 21 April 1989 Resolved
EMERGENCY CHECK LIST NOT POSTED.
Condition: Unknown
Due 21 April 1989
Resolved 21 April 1989
Lifesaving
Issued 21 April 1989 Resolved
PROVIDE THREE ADDITIONAL HAND RED FLARES
Condition: Unknown
Due 21 April 1989
Resolved 21 April 1989
Lifesaving
Issued 21 April 1989 Resolved
PROVIDE FOUR ADDITIONAL HAND ORANGE SMOKE DISTRESS SIGNAL.
Condition: Unknown
Due 21 April 1989
Resolved 21 April 1989